HomeMy WebLinkAboutDrainage Report 07-13-223850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
STORMWATER TECHNICAL INFORMATION REPORT
PREPARED FOR:
Dreyer & Reinbold Racing
Building Addition
4501 W. 99th Street
Carmel, IN 46032
July 13, 2022
3850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
1 | P a g e
PROJECT NARRATIVE
INTRODUCTION
This report summarizes the stormwater management calculations for the proposed Dreyer & Reinbold Racing building
addition located at 4501 W. 99th Street, Carmel, Hamilton County, Indiana. The total site area is 6.18 acres, with the
proposed improvement area consisting of only ±12,100 square feet. The stormwater analysis was performed based on the
requirements of the City of Carmel Technical Standards Manual.
SOILS
Per the USDA NRCS Web Soil Survey, the primary soil types inside the project limits are Urban-land Crosby Silt Loam (UcfA)
and Urban land Treaty complex (UmyA). A soils map is included in Appendix A.
FLOODPLAIN
Per the Flood Insurance Rate Map (FIRM) 18057C0225G, the site is not located in a floodplain (Zone X). A floodplain map
is in Tab A.
EXISTING CONDITIONS
The existing site parcel is 6.18 acres and is currently developed as the Dreyer & Reyer Reinbold Racing facility. The existing
building is ±52,000 square feet and is surrounded by concrete pavement on all sides that form parking areas, truck courts,
and drives. The existing drive connection is to W. 99th Street. The west side of the building, which is where the proposed
addition will be built, currently drains to an existing storm sewer system consisting of inlets and reinforced concrete pipe.
Runoff is collected in the storm system and discharged to the south to an existing swale on the south property line. The
entirety of the existing drainage areas is comprised of hard surface (roof, concrete pavement). The existing drainage areas
and runoff calculations were analyzed for the areas of the proposed addition.
The analyzed portion of the site drains to two different inlets, which combine to the same storm system. Individual runoff
rates and the combined total are summarized in Table 1. Calculations can be seen in Appendix B.
Table 1: Existing Drainage Summary
Return Period
Basin 2-year 10-year 100-year
EX-1 1.96 cfs 2.59 cfs 3.86 cfs
EX-2 2.72 cfs 3.59 cfs 5.35 cfs
Total 4.68 cfs 6.18 cfs 9.21 cfs
PROPOSED CONDITIONS
The proposed development consists of the construction of a ±10,440 square-foot building addition to the west side of the
building. The addition will be constructed over the existing concrete pavement. The existing pavement will be sawcut and
removed only where necessary for the installation of the building foundations, which corresponds to less than 5,000
square feet of land truly being disturbed. The only drainage improvement to be made is the addition of ADS Duraslot pipe
to provide a small trench drain in front of all overhead garage doors on the addition. The new piping will be connected to
the existing system at a proposed manhole over the existing RCP. No stormwater detention is proposed since the site
improvements do not add any new impervious areas. The theoretical proposed runoff is only negligible higher due to the
“C” value for roof areas being 0.90 and pavement being 0.85. This is a negligible increase since both areas are impervious.
Proposed individual runoff rates and the combined total are summarized in Table 2. Calculations can be seen in Appendix
C.
3850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
2 | P a g e
Table 2: Proposed Drainage Summary
Return Period
Basin 2-year 10-year 100-year
PROP-1 1.97 cfs 2.61 cfs 3.89 cfs
PROP-2 2.76 cfs 3.64 cfs 5.43 cfs
Total 4.73 cfs 6.25 cfs 9.32 cfs
If you have any questions, feel free to contact me.
Dillon Reynolds, PE
dreynolds@spacecoinc.com
317-779-2194
3850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
3 | P a g e
APPENDICES
Appendix A – Site Maps
Site Location Map
Soils Map
Wetlands Map
Flood Insurance Rate Map (FIRM)
Appendix B – Existing Conditions
Existing Drainage Basin Map
Existing Composite C Calculations
Existing Runoff Calculations (Rational Method)
Appendix C – Proposed Conditions
Proposed Drainage Basin Map
Proposed Composite C Value Calculations
Proposed Runoff Calculations (Rational Method)
3850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
Appendix A
Site Maps
500 ft
N➤➤NSITE LOCATION
PROJECT
LOCATION
Hydrologic Soil Group—Boone County, Indiana, and Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2022
Page 1 of 5442024044202704420300442033044203604420390442042044204504420480442024044202704420300442033044203604420390442042044204504420480564830564860564890564920564950564980565010
564830 564860 564890 564920 564950 564980 565010
39° 55' 55'' N 86° 14' 29'' W39° 55' 55'' N86° 14' 20'' W39° 55' 46'' N
86° 14' 29'' W39° 55' 46'' N
86° 14' 20'' WN
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 16N WGS84
0 50 100 200 300
Feet
0 15 30 60 90
Meters
Map Scale: 1:1,280 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
BUILDING ADDITION AREA
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Lines
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Points
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at scales
ranging from 1:12,000 to 1:15,800.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Boone County, Indiana
Survey Area Data: Version 24, Sep 3, 2021
Soil Survey Area: Hamilton County, Indiana
Survey Area Data: Version 22, Sep 9, 2021
Your area of interest (AOI) includes more than one soil survey
area. These survey areas may have been mapped at different
scales, with a different land use in mind, at different times, or at
different levels of detail. This may result in map unit symbols, soil
properties, and interpretations that do not completely agree
across soil survey area boundaries.
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Aug 1, 2018—Sep
30, 2018
Hydrologic Soil Group—Boone County, Indiana, and Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2022
Page 2 of 5
MAP LEGEND MAP INFORMATION
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Hydrologic Soil Group—Boone County, Indiana, and Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2022
Page 3 of 5
Hydrologic Soil Group
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
CudA Crosby silt loam, fine-
loamy subsoil, 0 to 2
percent slopes
C/D 1.1 14.8%
ThrA Treaty silty clay loam, 0
to 1 percent slopes
B/D 0.6 8.4%
Subtotals for Soil Survey Area 1.7 23.2%
Totals for Area of Interest 7.5 100.0%
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
UcfA Urban land-Crosby silt
loam complex, fine-
loamy subsoil, 0 to 2
percent slopes
4.1 54.1%
UmyA Urban land-Treaty
complex, 0 to 1
percent slopes
1.7 22.7%
Subtotals for Soil Survey Area 5.8 76.8%
Totals for Area of Interest 7.5 100.0%
Hydrologic Soil Group—Boone County, Indiana, and Hamilton County, Indiana
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
7/15/2022
Page 4 of 5
Wetlands
U.S. Fish and Wildlife Service, National Standards and Support Team,wetlands_team@fws.gov
Wetlands
Estuarine an d Marin e D eepwa ter
Estuarine an d Marin e Wetlan d
Freshwater Emergent Wetland
Freshwater Forested/Shrub We tla nd
Freshwater Pond
Lake
Other
Riverine
July 15 , 2022
0 0.1 0.20.05 mi
0 0.2 0.40.1 km
1:7,577
This page was produced by the NWI mapperNational Wetlands Inventory (NWI)
This map is for general reference only. The US Fish and Wildlife Service is not responsible for the accuracy or currentness of the base data shown on this map. All wetlands related data should be used in accordance with the layer metadata found on the Wetlands Mapper web site.
PROJECT LOCATION
National Flood Hazard Layer FIRMette
0 500 1,000 1,500 2,000250
Feet
Ü
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
SPECIAL FLOOD
HAZARD AREAS
Without Base Flood Elevation (BFE)
Zone A, V, A99
With BFE or DepthZone AE, AO, AH, VE, AR
Regulatory Floodway
0.2% Annual Chance Flood Hazard, Areas
of 1% annual chance flood with average
depth less than one foot or with drainage
areas of less than one square mileZone X
Future Conditions 1% Annual
Chance Flood HazardZone X
Area with Reduced Flood Risk due to
Levee. See Notes.Zone X
Area with Flood Risk due to LeveeZone D
NO SCREEN Area of Minimal Flood Hazard Zone X
Area of Undetermined Flood HazardZone D
Channel, Culvert, or Storm Sewer
Levee, Dike, or Floodwall
Cross Sections with 1% Annual Chance
17.5 Water Surface Elevation
Coastal Transect
Coastal Transect Baseline
Profile Baseline
Hydrographic Feature
Base Flood Elevation Line (BFE)
Effective LOMRs
Limit of Study
Jurisdiction Boundary
Digital Data Available
No Digital Data Available
Unmapped
This map complies with FEMA's standards for the use of
digital flood maps if it is not void as described below.
The basemap shown complies with FEMA's basemap
accuracy standards
The flood hazard information is derived directly from the
authoritative NFHL web services provided by FEMA. This map
was exported on 7/15/2022 at 8:46 AM and does not
reflect changes or amendments subsequent to this date and
time. The NFHL and effective information may change or
become superseded by new data over time.
This map image is void if the one or more of the following map
elements do not appear: basemap imagery, flood zone labels,
legend, scale bar, map creation date, community identifiers,
FIRM panel number, and FIRM effective date. Map images for
unmapped and unmodernized areas cannot be used for
regulatory purposes.
Legend
OTHER AREAS OF
FLOOD HAZARD
OTHER AREAS
GENERAL
STRUCTURES
OTHER
FEATURES
MAP PANELS
8
B 20.2
The pin displayed on the map is an approximate
point selected by the user and does not represent
an authoritative property location.
1:6,000
86°14'43"W 39°56'2"N
86°14'6"W 39°55'34"N
Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020
PROJECT LOCATION
3850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
Appendix B
Existing Conditions
8918908
9
0
891891EX-1
A = 0.49 ac
C = 0.86
Tc = 5 min
EX-2
A = 0.67 ac
C = 0.88
Tc = 5 min EXISTING DRAINAGE PLANEDP
N
R
SCALE 1" = 20'
200 40 3850 Priority Way South Drive, Suite 110Indianapolis, IN 46240Phone: (317) 779-2194NO.DATEREMARKSFILENAME:
DATE:
JOB NO.
SHEET
07/13/2022
12119 D&R RACING ADDITION4501 W. 99TH STREETCARMEL, IN 46032FILENAME:
EDP
PROJECT:D&R Racing Addition PROJECT #:12119
LOCATION:Carmel, IN DATE:7/13/2022
CALCULATION TITLE:
DESCRIPTION:EXISTING DRAINAGE AREAS
SITE CONDITION:EXISTING
Rational Method Runoff Coefficients
Roof 0.90
Asphalt 0.85
Concrete 0.85
Lawn 0.30
EX-1
Roof Asphalt/Concrete Lawn Total Total Composite
(ft2) (ft
2) (ft
2) (ft
2)(acres) C
5,525 15,819 0 21,344 0.490 0.86
EX-2
Roof Asphalt/Concrete Lawn Total Total Composite
(ft2) (ft
2) (ft
2) (ft
2)(acres) C
15,010 14,175 0 29,185 0.670 0.88
COMPOSITE C CALCULATIONS
PROJECT:D&R Racing Addition PROJECT #:12119
LOCATION:Carmel, IN DATE:7/13/2022
CALCULATION TITLE:
DESCRIPTION:RATIONAL METHOD RUNOFF
SITE CONDITION:EXISTING
2-YR
BASIN "C"i (in/hr)A (ac)Q (cfs)
EX-1 0.86 4.63 0.49 1.96
EX-2 0.88 4.63 0.67 2.72
10-YR
BASIN "C"i (in/hr)A (ac)Q (cfs)
EX-1 0.86 6.12 0.49 2.59
EX-2 0.88 6.12 0.67 3.59
100-YR
BASIN "C"i (in/hr)A (ac)Q (cfs)
EX-1 0.86 9.12 0.49 3.86
EX-2 0.88 9.12 0.67 5.35
RUNOFF
3850 Priority Way South Drive, Suite 110
Indianapolis, IN. 46240
Phone: 317-779-2194
Appendix C
Proposed Conditions
PROPOSED ADDITION
±10,440 SF891890 8
9
0
891891PROP-1
A = 0.49 ac
C = 0.87
Tc = 5 min
PROP-2
A = 0.67 ac
C = 0.89
Tc = 5 min PROPOSED DRAINAGE PLANPDP
N
R
SCALE 1" = 20'
200 40 3850 Priority Way South Drive, Suite 110Indianapolis, IN 46240Phone: (317) 779-2194NO.DATEREMARKSFILENAME:
DATE:
JOB NO.
SHEET
07/13/2022
12119 D&R RACING ADDITION4501 W. 99TH STREETCARMEL, IN 46032FILENAME:
PDP
PROJECT:D&R Racing Addition PROJECT #:12119
LOCATION:Carmel, IN DATE:7/13/2022
CALCULATION TITLE:
DESCRIPTION:PROPOSED DRAINAGE AREAS
SITE CONDITION:PROPOSED
Rational Method Runoff Coefficients
Roof 0.90
Asphalt 0.85
Concrete 0.85
Lawn 0.30
PROP-1
Roof Asphalt/Concrete Lawn Total Total Composite
(ft2) (ft
2) (ft
2) (ft
2)(acres) C
8,625 12,719 0 21,344 0.490 0.87
PROP-2
Roof Asphalt/Concrete Lawn Total Total Composite
(ft2) (ft
2) (ft
2) (ft
2)(acres) C
22,310 6,875 0 29,185 0.670 0.89
COMPOSITE C CALCULATIONS
PROJECT:D&R Racing Addition PROJECT #:12119
LOCATION:Carmel, IN DATE:7/13/2022
CALCULATION TITLE:
DESCRIPTION:RATIONAL METHOD RUNOFF
SITE CONDITION:PROPOSED
2-YR
BASIN "C"i (in/hr)A (ac)Q (cfs)
PROP-1 0.87 4.63 0.49 1.97
PROP-2 0.89 4.63 0.67 2.76
10-YR
BASIN "C"i (in/hr)A (ac)Q (cfs)
PROP-1 0.87 6.12 0.49 2.61
PROP-2 0.89 6.12 0.67 3.64
10-YR
BASIN "C"i (in/hr)A (ac)Q (cfs)
PROP-1 0.87 9.12 0.49 3.89
PROP-2 0.89 9.12 0.67 5.43
RUNOFF