Loading...
HomeMy WebLinkAboutA1.30 OVERALL ROOF DEMO PLANx1x5 x6 x6.5 x7 x7 x8 x9 x10 x12 x11 x11 x4 x3 x5.5 xA xB xC xD xE xF x2 x2 11911915' - 3 7/8"117 117 118 120120 11911913' - 6 1/8"117 117 118 119 120120 13' - 6 1/8"15' - 3 7/8"120 120 118 117 117 117 117 A. REGARDLESS OF SPECIFIC DEMOLITION NOTED HERE, THE CONTRACTORS SHALL PERFORM ALL DEMOLITION AS REQUIRED FOR NEW CONSTRUCTION. B. REGARDLESS OF SPECIFIC INFORMATION NOTED HERE AND ON NEW WORK PLANS, THE CONTRACTORS SHALL PATCH ANY DEMOLISHED AREAS AS REQUIRED FOR "AS NEW" FINAL APPEARANCE, IF NOT OTHERWISE SPECIFICALLY DIRECTED ON NEW WORK PLANS AND / OR IN THE SPECIFICATIONS. VERIFY FINISH INFORMATION FOR ANY SUCH WORK WITH THE ARCHITECT PRIOR TO STARTING. C. DO NOT DEMOLISH CONCEALED MECHANICAL OR ELECTRICAL SERVICES THAT ARE NOT SPECIFICALLY CALLED OUT FOR DEMOLITION ON THE ENGINEERING DRAWINGS WITHOUT FIRST VERIFYING WITH AND RECEIVING WRITTEN DIRECTION FROM THE ARCHITECT. D. EXISTING FLOORING VARIES -FIELD VERIFY EXISTING CONDITIONS DURING THE PRE-BID WALK THROUGH AGAINST REQUIREMENTS FOR NEW FLOORING SHOWN ON THE NEW WORK / FINISH PLANS. THE EXISTING CONCRETE FLOOR SHALL BE PATCHED / LEVELED / PREPARED AS REQUIRED PRIOR TO INSTALLATION OF NEW FLOORING. THE EXISTING PLYWOOD FLOORS ON LEVEL 2 SHALL BE PATCHED AND REPAIRED AS REQUIRED PRIOR TO INSTALLATION OF NEW FLOORING. COORDINATE WITH SPECIFICATIONS FOR PREP OF PLYWOOD FLOOR. E. WHERE INSTALLING NEW WALL FINISH / PROTECTION OR FLOORING, OR WHERE OTHER NEW WORK REQUIRES IT, REMOVE EXISTING-TO-REMAIN MECHANICAL AND ELECTRICAL FIXTURES AND ACCESSORIES, CLEAN AS NECESSARY, AND RE- INSTALL "AS NEW" OVER CONTINUOUS NEW WALL OR FLOOR FINISH. F. WHERE NEW SPRINKLERS ARE BEING INSTALLED, G.C. SHALL DEMOLISH AND PATCH EXISTING HARD CEILINGS AND WALLS AS REQUIRED TO ACCOMMODATE THAT WORK. CONSULT SPRINKLER DRAWINGS AND SPRINKLER CONTRACTOR FOR EXTENT OF REQUIRED WORK. G. REMOVE EXISTING SLAB AS NECESSARY FOR NEW PLUMBING. SEE PLUMBING DRAWINGS. PATCH FLOOR TO BE LEVEL IN PREPARATION FOR NEW FINISHES. H. SEE FIRE PROTECTION, PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION NOTES. I. PROTECT THE FINISH OF THE ELEVATOR'S FLOOR, CEILING AND WALL SURFACES AND ITS CONTROLS UNTILL BUILDING IS TURNED OVER TO OWNER. J. PROTECT EXISTING TO REMAIN ITEMS FROM ANY NEW CONSTRUCTION. REPAIR WITH LIKE MATERIALS IF DAMAGED DURING CONSTRUCTION. K. OWNER TO REMOVE ALL FURNITURE, ARTWORK AND MOVABLE EQUIPMENT PRIOR TO THE START OF CONSTRUCTION. L. CONTRACTOR IS RESPONSIBLE TO REMOVE ALL REMAINING WALL HUNG ITEMS, INCLUDING TOILET ACCESSORIES, MIRRORS, MARKERBOARDS, TACKBOARDS, CHALKBOARDS, PROJECTION SCREENS, FIRE EXTINGUISHER CABINETS, FIRE EXTINGUISHERS, WINDOW BLINDS, ROOM SIGNS, ETC. M. PATCH ALL RATED PARTITION WALLS TO REMAIN IN PROJECT AREA. FIRE STOP ANY OPENINGS IN PARTITIONS. SEE LIFE SAFETY DRAWINGS FOR RATED PARTITIONS. N. SEE PROJECT MANUAL FOR REQUIREMENTS REGARDING DUST CONTROL, INCLUDING TEMPORARY DUST PARTITIONS, AND THE PROTECTION OF SMOKE DETECTORS AND REVIEW ALL OWNER ICRA REQUIREMENTS. O. REMOVE EXISTING FLOORING AND BASE FROM SPACES UNLESS INDICATED OTHERWISE ON DRAWINGS OR FINISH SCHEDULE. P. REMOVE EXISTING CEILING, GRID AND CEILING FIXTURES AS REQUIRED FOR NEW CONSTRUCTION. COORDINATE WITH FINISH SCHEDULE, ELECTRICAL AND MECHANICAL DRAWINGS. Q. PATCH AND REPAIR ANY OPENINGS IN EXISTING LEVEL 2 SUB-FLOOR LEFT BY STAIR OR MECHANICAL CHASES THAT HAVE BEEN REMOVED. REPAIR OR REPLACE ANY 3/4" PLYWOOD SUB-FLOORING THAT HAS BEEN DAMAGED BY TIME, DEMOLITION OR NEW CONSTRUCTION BEFORE ANY FINISHES GO DOWN. R. AREAS SHADED ARE EXISTING TO REMAIN, TYPICAL. © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 OVERALL ROOF DEMO PLAN 04 MARCH 2022 A1.30MEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION1/8" = 1'-0"1 overall roof demo plan DEMOLITION PLAN GENERAL NOTES CODED NOTES - DEMO PLAN 100 EXISTING EXTERIOR WALL TO REMAIN, PROTECT THROUGHOUT CONSTRUCTION. 101 EXISTING EXTERIOR WINDOW OR STOREFRONT SYSTEM TO REMAIN, PROTECT THROUGHOUT CONSTRUCTION. 102 REMOVE EXISTING WALL TO EXTENTS SHOWN. 103 REMOVE EXISTING DOOR, HARDWARE & FRAME. 104 REMOVE EXISTING MILLWORK. 105 REMOVE EXISTING PLUMBING FIXTURE AND ALL ASSOCIATED PLUMBING. COORDINATE WITH PLUMBING DEMOLITION DRAWINGS. 106 REMOVE EXISTING LOW WALLS TO EXTENTS SHOWN. 107 REMOVE EXISTING STAIR, RAILINGS AND STAIR SUPPORTS. PREPARE OPENING FOR INFILL WITH SIMILAR CONSTRUCTION AS ADJACENT FLOOR. 108 REMOVE EXISTING TOILET ROOM ACCESSORIES AND MIRRORS. 109 REMOVE DOG KENNEL CMU WALLS AND ANY ACCESSORIES. 110 EXISTING STRUCTURAL COLUMN TO REMAIN. 111 CUT OPENING IN EXISTING WALL FOR NEW DOOR. SEE NEW WORK DOCUMENTS FOR SIZE AND LOCATION. SALVAGE ANY SPLIT FACE BLOCK FOR POSSIBLE RE-USE. 112 REMOVE EXISTING EXTERIOR WINDOW, FRAME, JAMB AND SILL. PREPARE OPENING FOR NEW INFILL 113 EXISTING ADJACENT CASSETTE BUILDING TO REMAIN AS IS UNLESS NOTED OTHERWISE. PROTECT THROUGH CONSTRUCTION. 114 REMOVE EXISTING EXTERIOR WALL AS INDICATED. STAGE REMOVAL WITH NEW CONSTRUCTION SO THAT SUPPORT OF ROOF IS NOT COMPROMISED. 115 EXISTING MEP ROOM, FLOOR, CEILING, WALLS AND EQUIPMENT TO REMAIN AS IS UNLESS NOTED OTHERWISE. 116 EXISTING STAIR, FLOOR, CEILING AND WALLS TO REMAIN AS IS UNLESS NOTED OTHERWISE. 117 REMOVE EXISTING ROOFING AND DECKING TO EXTENT AS SHOWN - FRAMING MAY REMAIN IF NEW INFILL CAN PROVIDE FINISHED PROFILE. 118 REMOVE HVAC SCREEN WALL 119 EXISTING METAL COPING TO REMAIN 120 REMOVE EXISTING MEMBRANE ROOFING AS NECESSARY TO COMPLETE NEW CONSTRUCTION - PATCH AND REPAIR UPON COMPLETION 121 REMOVE EXISTING EXTERIOR CEMENTITIOUS LAP SIDING FROM EXISTING TO REMAIN SHEATHING AND STUDS. ALSO REMOVE GWB ON INSIDE OF WALL DOWN TO STUDS UNO. PREPARE AS REQUIRED TO RECEIVE GWB WITH NEW WORK. 122 REMOVE EXISTING WET TABLES. 123 REMOVE EXISTING FLOOR DRAINS AND CAP ABANDONED LINES AS REQUIRED. COORDINATE WITH PLUMBING DEMOLITION DRAWINGS. PREP AND LEVEL SLOPPED FLOOR WITH CONCRETE FOR NEW CONSTRUCTION. 124 CUT OPENING IN EXISTING WALL FOR NEW WINDOW. SEE NEW WORK DOCUMENTS FOR SIZE AND LOCATION OF WINDOW. 125 EXISTING INTERIOR PARTITIONS TO REMAIN. PROTECT THROUGH CONSTRUCTION. 126 REMOVE EXISTING SPLIT-FACE BLOCK. TAKE CARE AND SALVAGE FOR POSSIBLE RE-USE. 127 EXISTING ROOF / ROOFING TO REMAIN. PROTECT THROUGH CONSTRUCTION. 128 EXISTING LOCKERS TO BE REMOVED. 129 SEE ROOF DEMOLITION PLAN. 130 EXISTING INSIDE LAYER OF GWB TO BE REMOVED FROM EXTERIOR STUD WALLS. GWB AND ANY ASSOCIATED ITEMS DAMAGED IN REMOVAL (AIR BARRIER, INSULATION) TO BE REPLACED OR REPAIRED WITH NEW WORK. 131 FLOOR AREA REPRESENTED BY HATCH PATTERN TO BE REMOVED TO MAKE WAY FOR NEW DOG KENNEL RUN FLOOR AND CURBS. COORDINATE WITH NEW WORK FOR LOCATION. 132 REMOVE EXISTING BEARING WALL AT STAIR AS INDICATED. STAGE REMOVAL WITH NEW CONSTRUCTION SO THAT SUPPORT OF FLOOR ABOVE IS NOT COMPROMISED. 07/13/22