Loading...
HomeMy WebLinkAboutA3.10 OVERALL FIRST FLOOR REFLECTED CEILING PLWAITING ROOM 101 VESTIBULE 100 EX STAIR S101 RR 105T EXAM 2 122 EXAM 6 126 GRIEF 138 GRIEF 137 SHELLED CT 152A RAD. TECH WORK AREA 152 EXAM 12 132 EXAM 11 131 EXAM 10 130 EXAM 13 133 EXAM 14 134 EXAM 9 129 EXAM 8 128 CORRIDOR X130 EXAM 7 127 EXAM 15 136 EXAM 3 123 EXAM 4 124 EXAM 5 125 CORRIDOR X120 MEP 135 EX MEP 120 EXAM 1 121 RR 114T XRAY 113JAN. 107D PROCEDURE ROOM 107C ER/TRIAGE 107 ICU 112 CLINCAL TEAM 107B CORRIDOR X140 CORRIDOR X150 RR 106T TRIAGE 107A TRAUMA 108 PHARMACY 109 CAT WARD 110 ANTE 111A ISOLATION 111B ISOLATION 111 JC 111C WARD 115 BARKING ROOM 115A LAUNDRY 116 ONCOLOGY SHELL SPACE 117 CARDIOLOGY 118 ECHO 118C STAIR S100 RR ELEVATOR SURGERY RECEIVING 141 RR 140T DOCTORS OFFICE 142 ENDOSCOPY 143A I.M. PRIVATE WORK 143B INTERNAL MEDICINE 143SHELL REHAB 146 NEURO SHELL SPACE 144 ULTRASOUND 145 EX MRI CASSETTE 151 RECEIVING / MORGUE 149 READING RM 148 ELECT. 150 RR 119T WORK RM 118A MECH 116APRIVATE WK RM 118B A. SEE SHEET A0.02 FOR WALL TYPES. ALL INTERIOR PARTITION WALLS ARE FULL HEIGHT, TYPE S3J, U.N.O. B. SEE ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING CEILING MOUNTED DEVICES. COORDINATE WITH ARCHITECTURAL CEILING PLAN FOR LAYOUT OF ANY DEVICES NOT SHOWN HERE. VERIFY WITH ARCHITECT IF DISCREPANCIES EXIST. C. CENTER NEW CEILING GRID IN ROOMS, UNLESS CALLED OUT OTHERWISE, TYP. D. SEE SHEET SERIES A8 FOR SOFFIT COLOR DESIGNATIONS AND FINISH INFORMATION. E. ROOM NUMBERS USED HERE ARE FOR THE PURPOSES OF THIS PROJECT. VERIFY ANY FINAL ROOM NUMBERING SYSTEM WITH THE OWNER PRIOR TO MAKING FINAL MARKS OR SCHEDULES RELATED TO ROOM NUMBERS. F. PATCH AND REPAIR ANY SURFACE OR OTHER ITEM DAMAGED BY OR INVOLVED IN CONSTRUCTION ACTIVITIES TO "AS NEW". REFER TO ENGINEERING DRAWINGS FOR P / M / E WORK THAT MAY REQUIRE PATCHING BY GENERAL TRADES CONTRACTOR. G. AREAS SHADED ARE EXISTING TO REMAIN. H. ALL NEW BLOCKING TO BE DOCUMENTED PER GENERAL NOTES AND PROJECT MANUAL. I. TYPICAL HEIGHT OF ELEMENTS ARE: a. ACOUSTICAL CEILINGS ON LEVEL 1 TO BE AT 8'-0" U.N.O. b. ACOUSTICAL CEILINGS ON LEVEL 2 TO BE AT 9'-0" U.N.O. c. SOFFITS ABOVE CABINETS TO BE AT 7'-2" ABOVE FINISHED FLOOR U.N.O. REFER TO THE ELECTRICAL LIGHTING PLANS FOR COMPLETE INFORMATION ON THE TYPE AND LOCATION OF ALL LIGHT FIXTURES, EXIT, DISCHARGE, AND EMERGENCY EGRESS FIXTURES. ACOUSTIC CEILING TILE & GRID GYPSUM BOARD CEILING 2x2 LAY-IN LIGHT FIXTURE 2x4 LAY-IN LIGHT FIXTURE CEILING MOUNTED EXIT SIGN RETURN AIR GRILLE SUPPLY AIR DIFFUSER RECESSED CAN LIGHT FIXTURE DIRECT/INDIRECT LIGHT FIXTURE LINEAR BOX LIGHT FIXTURE REFLECTED CEILING PLAN LEGEND PENDANT LIGHT FIXTURE WALL SCONCE C SECURITY CAMERA O O V OXYGEN OXYGEN / VACUUM EXISTING SPACE TO REMAIN. FUTURE SPACE AREA OF WORK PLAN KEY © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 OVERALL FIRST FLOOR REFLECTED CEILING PLAN 04 MARCH 2022 A3.10MEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION3/32" = 1'-0"A3.10 1 1st floor rcp -overall REFLECTED CEILING GENERAL NOTES CODED NOTES - REFLECTED CEILING PLAN 302 ALIGN ELEMENTS. 303 GYPSUM BOARD SOFFIT. 304 GYPSUM BOARD BULKHEAD @ 7'-2"A.F.F.U.N.O. 305 EXISTING GRID TO REMAIN AND BE PAINTED. REPLACE TILE 306 I.V. TRACKS. SEE A8 SERIES FOR DETAILS. 307 DIMMABLE CAN LIGHT. 309 NO CEILING. OPEN TO STRUCTURE ABOVE. 310 LIGHTING LAYOUT TO REMAIN. FIXTURES TO BE REPLACED 311 1 HOUR RATED GWB CEILING (UL DESIGN: I504). SEE DETAIL 8/A8.02. 312 1 HOUR RATED COILING DOOR 313 2" WALL TO ACT EXPANSION JOINT COVER. KEY PLAN A BC D 07/13/22