Loading...
HomeMy WebLinkAboutA3.10C FIRST FLOOR RCP -ARE CSHELLED CT 152A GRIEF 137 CORRIDOR X110 GRIEF 138 EXAM 6 126 EXAM 2 122 CORRIDOR X110 RR 106T CORRIDOR X110 EXAM 15 136 EXAM 3 123 EXAM 1 121 MEP 135 EX MEP 120 EXAM 11 131 EXAM 12 132 EXAM 13 133 EXAM 10 130 EXAM 7 127 EXAM 4 124 EXAM 5 125 EXAM 8 128 EXAM 9 129 EXAM 14 134 CORRIDOR X140 CORRIDOR X150 DOCTORS OFFICE 142 ENDOSCOPY 143A INTERNAL MEDICINE 143 I.M. PRIVATE WORK 143B SURGERY RECEIVING 141 RR 140T STAIR S100 ELEVATOR 0000 RR 139T ECHO 118C CARDIOLOGY 118 RR 119T CORRIDOR X120CORRIDOR X130 O O VO VO V O O O VO V A.C.T. 2x4 8' -0" A.C.T. 2x4 8' -0" A.C.T. 2x4 8' -0" A.C.T. 2x4 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x4 8' -0" A.C.T. 2x4 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0"A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x4 8' -0" A.C.T. 2x2 8' -0" 7' -0" A.C.T. 2x2 8' -0" A.C.T. 2x4 8' -0" EXISTING A.C.T. 2x2 8' -0" 8' -0" 303 A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x2 8' -0" 302302 302302 O VA3.10AA3.10BA3.10B A3.10AA3.10DA3.10DSURG RECEIVING WK RM 141A 7' -10" 7' -10" 7' -10" 7' -10" 302302 A.C.T. 2x2 8' -0" SEE 2ND FLOOR RCP 309309 A.C.T. 2x2 8' -0" RAD. TECH WORK AREA 152 7' -2" 7' -10" 8' -0" A.C.T. 2x2 8' -0" A.C.T. 2x4 8' -0" O O 313 A. SEE SHEET A0.02 FOR WALL TYPES. ALL INTERIOR PARTITION WALLS ARE FULL HEIGHT, TYPE S3J, U.N.O. B. SEE ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING CEILING MOUNTED DEVICES. COORDINATE WITH ARCHITECTURAL CEILING PLAN FOR LAYOUT OF ANY DEVICES NOT SHOWN HERE. VERIFY WITH ARCHITECT IF DISCREPANCIES EXIST. C. CENTER NEW CEILING GRID IN ROOMS, UNLESS CALLED OUT OTHERWISE, TYP. D. SEE SHEET SERIES A8 FOR SOFFIT COLOR DESIGNATIONS AND FINISH INFORMATION. E. ROOM NUMBERS USED HERE ARE FOR THE PURPOSES OF THIS PROJECT. VERIFY ANY FINAL ROOM NUMBERING SYSTEM WITH THE OWNER PRIOR TO MAKING FINAL MARKS OR SCHEDULES RELATED TO ROOM NUMBERS. F. PATCH AND REPAIR ANY SURFACE OR OTHER ITEM DAMAGED BY OR INVOLVED IN CONSTRUCTION ACTIVITIES TO "AS NEW". REFER TO ENGINEERING DRAWINGS FOR P / M / E WORK THAT MAY REQUIRE PATCHING BY GENERAL TRADES CONTRACTOR. G. AREAS SHADED ARE EXISTING TO REMAIN. H. ALL NEW BLOCKING TO BE DOCUMENTED PER GENERAL NOTES AND PROJECT MANUAL. I. TYPICAL HEIGHT OF ELEMENTS ARE: a. ACOUSTICAL CEILINGS ON LEVEL 1 TO BE AT 8'-0" U.N.O. b. ACOUSTICAL CEILINGS ON LEVEL 2 TO BE AT 9'-0" U.N.O. c. SOFFITS ABOVE CABINETS TO BE AT 7'-2" ABOVE FINISHED FLOOR U.N.O. REFER TO THE ELECTRICAL LIGHTING PLANS FOR COMPLETE INFORMATION ON THE TYPE AND LOCATION OF ALL LIGHT FIXTURES, EXIT, DISCHARGE, AND EMERGENCY EGRESS FIXTURES. ACOUSTIC CEILING TILE & GRID GYPSUM BOARD CEILING 2x2 LAY-IN LIGHT FIXTURE 2x4 LAY-IN LIGHT FIXTURE CEILING MOUNTED EXIT SIGN RETURN AIR GRILLE SUPPLY AIR DIFFUSER RECESSED CAN LIGHT FIXTURE DIRECT/INDIRECT LIGHT FIXTURE LINEAR BOX LIGHT FIXTURE REFLECTED CEILING PLAN LEGEND PENDANT LIGHT FIXTURE WALL SCONCE C SECURITY CAMERA O O V OXYGEN OXYGEN / VACUUM EXISTING SPACE TO REMAIN. FUTURE SPACE AREA OF WORK PLAN KEY © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 FIRST FLOOR RCP -AREA C 04 MARCH 2022 A3.10CMEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION1/4" = 1'-0" A3.10C 1 1st floor rcp -area C REFLECTED CEILING GENERAL NOTES CODED NOTES - REFLECTED CEILING PLAN 302 ALIGN ELEMENTS. 303 GYPSUM BOARD SOFFIT. 304 GYPSUM BOARD BULKHEAD @ 7'-2"A.F.F.U.N.O. 305 EXISTING GRID TO REMAIN AND BE PAINTED. REPLACE TILE 306 I.V. TRACKS. SEE A8 SERIES FOR DETAILS. 307 DIMMABLE CAN LIGHT. 309 NO CEILING. OPEN TO STRUCTURE ABOVE. 310 LIGHTING LAYOUT TO REMAIN. FIXTURES TO BE REPLACED 311 1 HOUR RATED GWB CEILING (UL DESIGN: I504). SEE DETAIL 8/A8.02. 312 1 HOUR RATED COILING DOOR 313 2" WALL TO ACT EXPANSION JOINT COVER. KEY PLAN A BC D 1 2022-03-17 Addendum 01 1 1 1 1 07/13/22