Loading...
HomeMy WebLinkAboutA3.20A SECOND FLOOR RCP -AREA AOPEN TO BELOW EX STAIR S201 OR 1 201 OR 2 202 OR 3 203 FLUOROSCOPY OR 206 CORRIDOR X220 O V V N O V V N O V V N A.C.T. 2x4 9' -0" A.C.T. 2x4 9' -0" A.C.T. 2x4 9' -0" A.C.T. 2x4 9' -0" A.C.T. 2x4 9' -0" A.C.T. 2x4 9' -0" A.C.T. 2x4 9' -0" OR 4 204 CORRIDOR X210 O V V N 7' -2" 304 7' -2" 304 7' -2" A.C.T. 2x4 9' -0" 302 A3.20B A3.20B 3047' -2" 305310 305305 A. SEE SHEET A0.02 FOR WALL TYPES. ALL INTERIOR PARTITION WALLS ARE FULL HEIGHT, TYPE S3J, U.N.O. B. SEE ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING CEILING MOUNTED DEVICES. COORDINATE WITH ARCHITECTURAL CEILING PLAN FOR LAYOUT OF ANY DEVICES NOT SHOWN HERE. VERIFY WITH ARCHITECT IF DISCREPANCIES EXIST. C. CENTER NEW CEILING GRID IN ROOMS, UNLESS CALLED OUT OTHERWISE, TYP. D. SEE SHEET SERIES A8 FOR SOFFIT COLOR DESIGNATIONS AND FINISH INFORMATION. E. ROOM NUMBERS USED HERE ARE FOR THE PURPOSES OF THIS PROJECT. VERIFY ANY FINAL ROOM NUMBERING SYSTEM WITH THE OWNER PRIOR TO MAKING FINAL MARKS OR SCHEDULES RELATED TO ROOM NUMBERS. F. PATCH AND REPAIR ANY SURFACE OR OTHER ITEM DAMAGED BY OR INVOLVED IN CONSTRUCTION ACTIVITIES TO "AS NEW". REFER TO ENGINEERING DRAWINGS FOR P / M / E WORK THAT MAY REQUIRE PATCHING BY GENERAL TRADES CONTRACTOR. G. AREAS SHADED ARE EXISTING TO REMAIN. H. ALL NEW BLOCKING TO BE DOCUMENTED PER GENERAL NOTES AND PROJECT MANUAL. I. TYPICAL HEIGHT OF ELEMENTS ARE: a. ACOUSTICAL CEILINGS ON LEVEL 1 TO BE AT 8'-0" U.N.O. b. ACOUSTICAL CEILINGS ON LEVEL 2 TO BE AT 9'-0" U.N.O. c. SOFFITS ABOVE CABINETS TO BE AT 7'-2" ABOVE FINISHED FLOOR U.N.O. REFER TO THE ELECTRICAL LIGHTING PLANS FOR COMPLETE INFORMATION ON THE TYPE AND LOCATION OF ALL LIGHT FIXTURES, EXIT, DISCHARGE, AND EMERGENCY EGRESS FIXTURES. ACOUSTIC CEILING TILE & GRID GYPSUM BOARD CEILING 2x2 LAY-IN LIGHT FIXTURE 2x4 LAY-IN LIGHT FIXTURE CEILING MOUNTED EXIT SIGN RETURN AIR GRILLE SUPPLY AIR DIFFUSER RECESSED CAN LIGHT FIXTURE DIRECT/INDIRECT LIGHT FIXTURE LINEAR BOX LIGHT FIXTURE REFLECTED CEILING PLAN LEGEND PENDANT LIGHT FIXTURE WALL SCONCE C SECURITY CAMERA O O V OXYGEN OXYGEN / VACUUM EXISTING SPACE TO REMAIN. FUTURE SPACE AREA OF WORK PLAN KEY © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 SECOND FLOOR RCP - AREA A 04 MARCH 2022 A3.20AMEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION1/4" = 1'-0"A3.20A 1 2nd floor rcp -area A A B CD E REFLECTED CEILING GENERAL NOTES CODED NOTES - REFLECTED CEILING PLAN 302 ALIGN ELEMENTS. 303 GYPSUM BOARD SOFFIT. 304 GYPSUM BOARD BULKHEAD @ 7'-2"A.F.F.U.N.O. 305 EXISTING GRID TO REMAIN AND BE PAINTED. REPLACE TILE 306 I.V. TRACKS. SEE A8 SERIES FOR DETAILS. 307 DIMMABLE CAN LIGHT. 309 NO CEILING. OPEN TO STRUCTURE ABOVE. 310 LIGHTING LAYOUT TO REMAIN. FIXTURES TO BE REPLACED 311 1 HOUR RATED GWB CEILING (UL DESIGN: I504). SEE DETAIL 8/A8.02. 312 1 HOUR RATED COILING DOOR 313 2" WALL TO ACT EXPANSION JOINT COVER. KEY PLAN 1 2022-03-17 Addendum 01 1 07/13/22