HomeMy WebLinkAboutA5.01 ENLARGED TOILET PLA AND ELEVATIONSRR 105T A5.01 2A5.015 A5.01 4 A5.013 507 506508 510 502 501 1' - 0"3' - 6"T-3 T-5 T-8 T-7 3' - 4"6" 3' - 0" 1' - 5" T-6 T-2 T-4 1' - 3"T-9 T-12 T-10 TOILET ACCESSORY MOUNTING SCHEDULE T-1 MOP HOLDER (WALL MOUNTED): 60" A.F.F. TO CENTERLINE T-2 PAPER TOWEL DISPENSER T-3 SANITARY NAPKIN DISPOSAL: 30" A.F.F. TO TOP. 36" MAXIMUM FROM REAR WALL TO FURTHEST EDGE T-4 SOAP PAPER DISPENSER T-5 TOILET PAPER DISPENSER (DOUBLE ROOL): 18" A.F.F. TO ROLL CENTERLINE. 7"-9" FROM FRONT EDGE OF WATER CLOSET TO CENTERLINE OF ROLL -E09B T-6 REAR WALL GRAB BAR (1 1/2" O.D. X 36" MIN LONG): 32.5" MIN TO 35" MAX A.F.F. TO CENTERLINE AND 6" FROM SIDE WALL T-7 SIDE WALL GRAB BAR (1 1/2" O.D. X 42" MIN LONG): 32.5" MIN TO 35" MAX A.F.F. TO CENTERLINE AND 12" FROM REAR WALL T-8 SIDE WALL VERTICAL GRAB BAR (1 1/2" O.D. X 18" MIN LONG): 39" MIN TO 41" MAX TO THE BOTTOM END AND 40" TO THE CENTERLINE FROM THE REAR WALL. T-9 MIRROR WITHOUT SHELF: 40" A.F.F. TO BOTTOM OF REFLECTIVE SURFACE T-10 CHILD CHANGING STATION 2'-7" MIN A.F.F. TO UNDERSIDE OF TABLE TOP AND 46" MAX TO HANDLE IN CLOSED POSITION. T-11 PROTECTIVE PIPE COVERS: "LAV-GUARD" BY TRUEBRO T-12 CONVENIENCE HOOK: 46" A.F.F. TO UNIT CENTERLINE T-13 SHOWER CURTAIN ROD, CURTAIN AND HOOKS: 72" A.F.F. TO CENTERLINE T-14 MIRROR WITH SHELF: 40" A.F.F. TO BOTTOM OF REFLECTIVE SURFACE T-16 LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS FOR REFERENCE. T-18 20" WIDE WALL-MOUNTED FOLD-UP SHOWER SEAT: TOP OF SEAT 18" A.F.F. A. SEE SHEET A0.02 FOR WALL TYPES. ALL INTERIOR PARTITION WALLS ARE FULL HEIGHT, TYPE S3J, U.N.O. B. SEE SHEET A0.04 FOR TYPICAL ADA INFORMATION. C. SEE SHEETS A0.50 & A0.51 FOR LIFE SAFETY PLANS INDICATING RATED PARTITION WALL CONSTRUCTION. D. SEE SHEET SERIES A3 FOR CEILING HEIGHTS. E. SEE SHEET SERIES A4 FOR EQUIPMENT LAYOUTS. SEE SPECIFICATION APPENDIX FOR MORE DETAILED EQUIPMENT INFORMATION. F. SEE SHEETS A10.0, A10.01 & A10.02 FOR DOOR & WINDOW SCHEDULES & TYPES. G. SEE SHEET SERIES A8 FOR FLOOR PATTERN PLAN AND FINISH INFORMATION. SEE FINISH PLANS FOR LOCATION OF CORNER GUARDS. H. SEE ALL CONSULTANT AND VENDOR DRAWINGS FOR ADDITIONAL INFORMATION. I. ROOM NUMBERS USED HERE ARE FOR THE PURPOSES OF THIS PROJECT. VERIFY ANY FINAL ROOM NUMBERING SYSTEM WITH THE OWNER PRIOR TO MAKING FINAL MARKS OR SCHEDULES RELATED TO ROOM NUMBERS. J. PATCH AND REPAIR ANY SURFACE OR OTHER ITEM DAMAGED BY OR INVOLVED IN CONSTRUCTION ACTIVITIES TO "AS NEW". REFER TO ENGINEERING DRAWINGS FOR MEP WORK THAT MAY REQUIRE PATCHING BY GENERAL TRADES CONTRACTOR. K. AREAS SHADED ARE EXISTING TO REMAIN. L. ALL NEW BLOCKING TO BE DOCUMENTED PER GENERAL NOTES AND PROJECT MANUAL. M. INFILL EXISTING SECOND FLOOR SLAB AT ALL ABANDONED PENETRATIONS WITH "LIKE" STRUCTURE PER STRUCTURAL DRAWINGS. INCLUDE THE VACATED STAIRWAY, SHAFTS, AND PIPING PENETRATIONS. 505 1' - 3"2' - 10"3' - 4"1' - 3" 6"3' - 0" 503 1' - 7"502 503501 T-9 T-4 T-16 T-6 505 3' - 10"T-2 501 T-9 T-16 T-12 505 504 505 2' - 11"1' - 6"3' - 5 1/2"503503 1' - 0"3' - 6" 1' - 2"1' - 7"T-3 T-5 502 T-7 T-8 RR 106T 3' - 6" 1' - 0" 3' - 4"1' - 5"3' - 0"6"1' - 4"T-12 T-2 T-4 T-9 T-6 T-5 T-3 T-7 T-8 506 507 510 508 A5.012 SIMA5.01 3 SIM A5.014 SIMA5.01 5 SIM 502 501 T-10 RR 114T 1' - 4"1' - 5" 6" 3' - 0"1' - 0"3' - 6"3' - 4"502 501 T-2 T-4 T-9 T-6 T-7 T-8 T-5 T-3 508 506 510 A5.01 2 SIM A5.013 SIMA5.01 4 SIM A5.015 SIMT-12 RR 119T 3' - 6" 1' - 0" 3' - 4"6"3' - 0"1' - 5"1' - 4"T-2 T-4 T-9 T-6 T-5 T-3 T-7T-8 508 506 507 510 502 501A5.012 SIMA5.01 5 SIM T-12 RR 140T T-21' - 6"1' - 5"3' - 0"6"1' - 0" 3' - 6" 3' - 4" T-4 T-9 T-6 T-7T-8 T-5 T-3 502 501 510 506 507 508 A5.012 SIMA5.01 5 SIM A5.013 SIMA5.01 3 SIM T-12 RR 147T 1' - 4"1' - 5"3' - 0"6"3' - 6" 1' - 0" 3' - 4" 502 501 T-2 T-4 T-7 T-8 T-5 T-3 T-12 A5.012 SIMA5.01 5 SIM 506 507508 510 RR 220T 3' - 0"6"1' - 5"1' - 4"3' - 4" 1' - 0" 3' - 6" 502 501 T-4 T-2 T-3 T-8 T-5 T-7 T-6 T-12 RR 227T RR 228T 506 506 501 502 507 508 510 510 501 502 508 507 T-2 T-4 1' - 5"1' - 0"3' - 6"3' - 4"3' - 6"1' - 0"3' - 4"T-3 T-8 T-8 T-3 T-7 T-8 T-7 T-8 1' - 4" T-4 504 T-2 T-4 T-5 T-3 T-8 T-7 T-6 T-9 510 RR 139T 1' - 5"3' - 6"1' - 0"3' - 4"1' - 4" A5.01 2 SIM A5.015 SIMT-12 506 © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 ENLARGED TOILET PLANS AND ELEVATIONS 04 MARCH 2022 A5.01 MEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION1/2" = 1'-0"A5.01 1 enlarged plan -105T CODED NOTES - ENLARGED PLANS 501 SINK, REFER TO MEP DRAWINGS. 502 TOILET, REFER TO MEP DRAWINGS. 503 WALL PROTECTION, REFER TO A8 FINISH SERIES. 504 DOOR AND FRAME, SEE A10 DOOR SCHEDULE AND DETAIL SERIES. 505 WALL BASE. REFER TO FINISH SCHEDULE. 506 ADA TURNAROUND CLEARANCE; SEE SHEET A0.04. 507 ADA DOOR CLEARANCE, SEE SHEET A0.04. 508 ADA TOILET CLEARANCE, SEE SHEET A0.04. 510 ADA SINK CLEARANCE; SEE SHEET A0.04. 513 FLOOR DRAIN, SLOPE FLOOR TO DRAIN. SEE PLUMBING DRAWINGS. 514 4" W. CONCRETE CURB, TOP OF CURB AT 2" AFF. ALL SIDES OF CURB TO BE EPOXY: SEE FINISH LEGEND. 515 KENNEL RUN ENCLOSURE SYSTEM BY SHOR-LINE OR APPROVED EQUAL ENCLOSURE TO HAVE SOLID STAINLESS STEEL SIDE PANEL AT BOTTOM AND STAINLESS STEEL WIRE MESH TOP. PANELS TO BE ATTACHED TO THE WALLS, CAGE DOORS TO BE 34" WIDE, FULL HEIGHT DOOR WITH BOTTOM GLASS PANEL AND STAINLESS STEEL WIRE TOP. SEE DETAILS ON THIS SHEET. REFER TO ITEM E32A IN THE EQUIPMENT SPEC INCLUDED IN APPENDIX A OF THE PROJECT MANUAL. 516 1 1/4" X 1 1/4" STAINLESS STEEL TUBING WITH MITERED CORNERS. 517 SLOPE CONCRETE FLOOR TO DRAIN. 518 SOLID STAINLESS STEEL PANEL. 519 STAINLESS STEEL WIRE MESH. 520 GLASS PANELS. 521 WALL PROTECTION FULL HEIGHT. SEE FINISH PLAN AND SCHEDULE. 522 PROVIDE WALL PROTECTION ON CASEWORK FINISH END FACING RUN. 523 KENNEL RUN ENCLOSURE SYSTEM FOR THE ISOLATION TUB / KENNAL BY SHOR-LINE OR APPROVED EQUAL ENCLOSURE TO HAVE GLASS SIDE PANEL AT BOTTOM AND STAINLESS STEEL WIRE MESH TOP. PANELS TO BE ATTACHED TO THE WALLS, CAGE DOORS TO BE 36" WIDE, FULL HEIGHT DOOR WITH BOTTOM GLASS PANEL AND STAINLESS STEEL WIRE TOP. SEE DETAILS ON THIS SHEET. REFER TO ITEM E32A IN THE EQUIPMENT SPEC INCLUDED IN APPENDIX A OF THE PROJECT MANUAL. 524 EXTEND FULL HEIGHT WALL PROTECTION 1'-0" PAST KENNEL END PANEL. FLOOR PLAN GENERAL NOTES 1/2" = 1'-0"A5.01 2 elevation -105T typ. 1/2" = 1'-0"A5.01 3 elevation -105T typ. 1/2" = 1'-0"A5.01 4 elevation -105T typ. 1/2" = 1'-0"A5.01 5 elevation -105T typ. 1/2" = 1'-0"A5.01 6 enlarged plan - 106T 1/2" = 1'-0"A5.01 7 enlarged plan -114T 1/2" = 1'-0"A5.01 8 enlarged plan -119T 1/2" = 1'-0"A5.01 10 enlarged plan -140T 1/2" = 1'-0"A5.01 11 enlarged plan -147T 1/2" = 1'-0"A5.01 12 enlarged plan -220T 1/2" = 1'-0"A5.01 13 enlarged plan -227T, 228T 1/2" = 1'-0"A5.01 9 enlarged plan -139T 07/13/22