Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A7.03 EXTERIOR WALL SECTIONS
FIRST FLOOR 100' -0" SECOND FLOOR 112' -0" ROOF T.O.S. L.P. 126' -0 1/2" PARAPET D 130' -4" A ROOF C 124' -0 1/2" 701 708 709 715 736 731 742 709 714 716 734 716 714 715 720 722 731 738 720 731 729 728 757 740 727 726 724 725 717 718 732 732 719 5' - 4"8"1' - 5 1/4"6" 6" 4"5' - 4"10' - 0"2' - 10 3/4"6' - 8 3/4"A7.08 7 A7.08 8 2' - 8"4' - 4"4' - 4"2' - 8"A7.07 6 A7.07 1 A7.07 5 1 761 8"1' - 4"1"1" 730 760760 761 FIRST FLOOR 100' -0" SECOND FLOOR 112' -0" ROOF T.O.S. L.P. 126' -0 1/2" PARAPET D 130' -4" A 701 707 708 709 710 739 705 706 703 711 702 8"10' - 0"1' - 5 1/4"14' - 11 1/2"746 739 731 721 714 715 712 713 737 716 722 716 714 715 746 717 718 719 720 717717 757 720 752 753 753 754 724 725 727 740 726 749 1 761 8"1' - 4"1"1" 730 760760 731 FIRST FLOOR 100' -0" SECOND FLOOR 112' -0" ROOF T.O.S. L.P. 126' -0 1/2" PARAPET D 130' -4" 701 745703 711 741 735 744 730 731 729 728 726 714 7' - 0"2"4' - 10"2"8' - 10"2"5' - 10"2"3' - 1"2"3' - 1 1/2"2"744 FIRST FLOOR 100' -0" SECOND FLOOR 112' -0" ROOF T.O.S. L.P. 126' -0 1/2" A 701 708 739 709 715 755 731 730 2' - 4" 7 5/8" 35' - 4"756 A7.08 4 A7.08 5 A7.08 6 728 740 727 729 749 726 724 717 762 © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 EXTERIOR WALL SECTIONS 04 MARCH 2022 A7.03MEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION1/2" = 1'-0"A7.03 1 wall section 1/2" = 1'-0"A7.03 2 wall section 1/2" = 1'-0"A7.03 3 wall section 1/2" = 1'-0"A7.03 4 wall section CODED NOTES - WALL SECTIONS 701 CONCRETE FOUNDATION - SEE STRUCTURAL DRAWINGS 702 CONCRETE SLAB ON GRADE OVER 15 MIL VAPOR BARRIER - SEE STRUCTURAL DRAWINGS 703 COMPACTED FILL - SEE STRUCTURAL DRAWINGS 705 2" RIGID PERIMETER FOUNDATION INSULATION 706 2" RIGID INSULATION - BELOW SLAB 707 GROUT CAVITY SOLID 708 METAL BASE FLASHING 709 THROUGH WALL MEMBRANE FLASHING 710 CONTINUOUS MORTAR NET 711 STONE DRAINAGE BASECOURSE - SEE STRUCTURAL DRAWINGS 712 2" POLYISOCYANURATE INSULATION BOARD 713 4" X 8" X 16" SPLIT FACE CONCRETE MASONRY UNIT VENEER 714 5/8" EXTERIOR GYPSUM SHEATHING 715 FLUID APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER 716 6" COLD FORMED METAL FRAMING - SEE STRUCTURAL DRAWINGS 717 STEEL STRUCTURAL FRAMING - SEE STRUCTURAL DRAWINGS 718 METAL FLOOR DECK WITH CONCRETE TOPPING - SEE STRUCTURAL DRAWINGS 719 CONTINUOUS STEEL BENT PLATE - SEE STRUCTURAL DRAWINGS 720 COLD FORMED METAL FRAMING CLIP BY CFMF MANUFACTURER 721 CONCRETE MASONRY UNIT SILL - SHAPE 1 722 EXTERIOR INSULATION FINISH SYSTEM 723 INTERIOR PARTITION - SEE FLOOR PLANS 724 METAL ROOF DECK - SEE STRUCTURAL DRAWINGS 725 VAPOR RETARDER 726 THERMOPLASTIC POLYOLEFIN MEMBRANE ROOFING 727 5" POLYISOCYANURATE ROOFING INSULATION 728 TERMINATION BAR 729 VERTICAL TPO MEMBRANE APPLICATION 730 PRE-FABRICATED PREFINISHED METAL WALL CAP FLASHING 731 FIRE RETARDANT TREATED WOOD BLOCKING 732 SOLID SURFACE WINDOW STOOL - SEE INTERIORS SCHEDULE 733 LAY-IN CEILING SYSTEM - SEE INTERIORS SCHEDULE 734 CONCRETE MASONRY UNIT SILL - SHAPE 2 735 4 1/2" DEEP ALUMINUM STOREFRONT WINDOW SYSTEM 736 BACKER ROD AND SEALANT 737 EXTERIOR BATT INSULATION 738 BOXED-BEAM C.F.MS. HEADER - SEE STRUCTURAL DRAWINGS 739 CAVITY VENT/ WEEP 740 1" HIGH DENSITY POLYISOCYANURATE ROOF INSULATION 741 ALUMINUM AND GLASS ENTRY SYSTEM 742 LOOSE STEEL LINTEL - SEE GENERAL STRUCTURAL NOTES 743 FROST SLAB - SEE STRUCTURAL DRAWINGS 744 COLD FORMED METAL FRAMING - NON STRUCTURAL 745 ALUMINUM DOOR THRESHOLD - SEE DOOR HARDWARE 746 5/8" GYPSUM BOARD - FINISH PER FINISH SCHEDULE 747 EXISTING CONSTRUCTION TO REMAIN 748 NEW ROOF DRAIN - SEE PLUMBING DRAWINGS 749 TAPERED INSULATION CRICKET BACK TO NEW DRAINS OR THROUGH WALL SCUPPERS 750 PATCH AND REPAIR ALL MEMBRANE ROOFING AT NEW ROOF DRAIN INSTALLATIONS 752 SHEET METAL CONDUCTOR HEAD AND INTEGRAL SCUPPER PER SMACNA SPECIFICATIONS 753 4" DIAMETER DOWNSPOUT 754 STORMWATER DISCHARGE - SEE CIVIL DRAWINGS FOR CONNECTIONS 755 3" POLYISOCYANURATE INSULATION BOARD 756 8" X 8" X 16" CONCRETE MASONRY UNIT 757 CONTINUOUS STEEL ANGLE - SEE STRUCTURAL DRAWINGS 758 NEW INFILL CONSTRUCTION - MATCH ADJACENT EXISTING MATERIALS, SEE ELEVATIONS FOR EXTENTS 759 NEW ROOFING AT NEW INFILL ROOF = MATCH ADJACENT EXISTING ROOFING MATERIAL AND CONSTRUCTION 760 PROVIDE 3/4" CHAMFER AT E.I.F.S. EDGE 761 1" DEEP "VEE" GROOVE IN INSULATION MATERIAL 762 CONCRETE MASONRY UNIT CAVITY INSULATION 763 3" & 4" EXTERIOR INSULATION FINISHING SYSTEM FRIEZE 764 2" EXPANSION JOINT WITH FOAM ROD TUBING AND BATT INSULATION 765 2 1/2" COLD FORMED METAL FRAMING - SEE STRUCTURAL DRAWINGS 766 PREFINISHED METAL PANELS - SEE SPECIFICATIONS 1 2022-03-17 Addendum 01 1 07/13/22