HomeMy WebLinkAboutA8.01 ROOM FINISH SCHEDUL© 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 ROOM FINISH SCHEDULE 04 MARCH 2022 A8.01MEDVET INDIANAPOLIS -ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITIONROOM FINISH SCHEDULE + ROOM NAME FLOOR BASE FIELD WALL FINISH ACCENT WALL FINISH MILLWORK FINISH COUNTER FINISH CEILING MATL/FINISH REMARKS (SEE NUMBERED SCHEDULE NOTES, BELOW) 222 J.C.SEALED RB-5 PT-1/FRP-1 ---EXP. NOTE: 7 223 CENTRAL SUPPLY SEALED RB-5 PT-1/FRP-1 ---ACT-1 NOTE: 7 224 LOCKER ROOM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 225 MOTHERS ROOM RSF-3 RB-5 PT-1 -PLAM-4 SSM-2 ACT-1 NOTE: 4 226 IT SEALED RB-5 PT-1 ---ACT-1 227 EXAM 6 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 227T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 228T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 229 WELLNESS CPT-1 RB-6 PT-1 ---ACT-1 230 BREAK ROOM RSF-3 RB-5 PT-1 ---ACT-1 NOTE: 9 231 KITCHENETTE RSF-3 RB-5 PT-1 -PLAM-4 SSM-2 ACT-1 NOTE: 4 232 CONFERENCE ROOM CPT-1 RB-5 PT-1 PT-9 PLAM-4 PLAM-6 ACT-1 NOTE: 1, 5 S100 STAIR ST-1/ST-2 RB-5 PT-1 ---EXP. NOTE: 13 S101 EX STAIR EXT.- PT-1 ---EXP. NOTE: 13 S200 STAIR ST-1/ST-2 RB-5 PT-1 ---GYP/PT-1 NOTE: 13 X110 CORRIDOR RSF-2 RB-1 PT-1 -PLAM-4 SSM-2 @ SINK ACT-1/GYP/PT-1 NOTE: 4 X120 CORRIDOR RSF-2 RB-1 PT-1 -PLAM-4 SSM-2 @ SINK ACT-1 NOTE: 4 X130 CORRIDOR RSF-2 RB-1 PT-1 ---ACT-1 X140 CORRIDOR RSF-2 RB-1 PT-1 -PLAM-4 SSM-2 @ SINK ACT-1 NOTE: 4 X150 CORRIDOR RSF-3 RB-5 PT-1/WP-1 PT-4/WP-2 --ACT-1 NOTE: 1, 3 X210 CORRIDOR RSF-5 RB-4 PT-1/WP-1 -PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-4 NOTE: 2, 4 X220 CORRIDOR RSF-3 RB-5 PT-1 ---ACT-1 X230 CORRIDOR RSF-3 / CPT-1 RB-5 PT-1 WP-1 --ACT-1 X240 CORRIDOR RSF-3 RB-5 PT-1/WP-1 ---GYP/PT-1 NOTE: 3 X250 CORRIDOR RSF-3 RB-5 PT-1 ---ACT-1 ROOM FINISH SCHEDULE + ROOM NAME FLOOR BASE FIELD WALL FINISH ACCENT WALL FINISH MILLWORK FINISH COUNTER FINISH CEILING MATL/FINISH REMARKS (SEE NUMBERED SCHEDULE NOTES, BELOW) 000 ELEVATOR RSF-3 100 VESTIBULE RSF-2 RB-1 PT-1 -- -GYP/PT-1 101 WAITING ROOM RSF-1/RSF-2 RB-1 PT-1 -PLAM-2 PLAM-3 ACT-2/GYP/PT-1/EXP. NOTE: 9 102 RECEPTION RSF-1 RB-1/ PLAM-7 @ RECEPT DESK PT-1 PT-9 PLAM-1/PLAM-2/REV-1 SSM-1 @ RECEPT DESK, PLAM-3 @ BACK COUNTER ACT-2/GYP/PT-9 NOTE: 1 103 CAT-FRIENDLY WAITING RSF-2 RB-1 PT-1 -- -GYP/PT-1/EXP. NOTE: 9 104 CHECK OUT AREA 105T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 106T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 107 ER/TRIAGE RSF-3 RB-5 PT-1/WP-1 /PT-5/WP-3/ FRP BEHIND CAGES PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 1, 2, 4, 10 107A TRIAGE RSF-3 RB-5 PT-1 PT-3 PLAM-4 PLAM-6 ACT-2 107B CLINCAL TEAM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 107C PROCEDURE ROOM RSF-3 RB-5 PT-1/WP-1 -PLAM-4 SSM-2 ACT-2 NOTE: 3, 4 107D JAN.SEALED RB-5 PT-1/FRP-1 ---EXP. NOTE: 7 108 TRAUMA RSF-3 RB-1 PT-1 PT-3 PLAM-8 SSM-4 ACT-2 109 PHARMACY RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 4 110 CAT WARD RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 2, 4, 10 111 ISOLATION RSF-4 RB-2 PT-6/FRP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 4, 6, 7, 9 111A ANTE RSF-4 RB-2 PT-6/FRP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 7 111B ISOLATION RSF-4 RB-2 PT-6/FRP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 6, 7, 10 111C JC SEALED RB-5 PT-1/FRP-1 ---EXP. NOTE: 7 112 ICU RSF-3/RSF-4 @ RUNS RB-3 PT-1/WP-1 FRP BEHIND RUNS AND/OR CAGES PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 2, 4, 6, 9, 10 113 XRAY RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 114T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 115 WARD RSF-3/RSF-4 @ RUNS RB-5 PT-1/WP-1 FRP BEHIND RUNS AND/OR CAGES PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 2, 4, 6, 9, 10 115A BARKING ROOM RSF-3/RSF-4 @ RUNS RB-5 PT-1/WP-1 FRP BEHIND RUNS AND/OR CAGES PLAM-4 PLAM-6 ACT-1 NOTE: 3, 6, 10 116 LAUNDRY SEALED RB-5 PT-1/FRP-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 7 116A MECH SEALED RB-5 PT-1 ---EXP. 116B DRYER ROOM 117 ONCOLOGY SHELL SPACE RSF-3 - ----EXP. NOTE: 11 118 CARDIOLOGY RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 118A WORK RM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8, 9 118B PRIVATE WK RM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 118C ECHO RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 119T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 120 EX MEP EXT.EXT. EXT.---EXT. 121 EXAM 1 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 122 EXAM 2 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 123 EXAM 3 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 124 EXAM 4 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 125 EXAM 5 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 126 EXAM 6 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 127 EXAM 7 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 128 EXAM 8 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 129 EXAM 9 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 130 EXAM 10 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 131 EXAM 11 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 132 EXAM 12 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 133 EXAM 13 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 134 EXAM 14 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 135 MEP SEALED RB-5 PT-1/FRP-1 ---EXP. NOTE: 7 136 EXAM 15 RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 137 GRIEF RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 138 GRIEF RSF-1 RB-1 PT-1 PT-3 PLAM-8 PLAM-5 ACT-2 NOTE: 1 139T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 140T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 141 SURGERY RECEIVING RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 4 141A SURG RECEIVING WK RM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8, 9 142 DOCTORS OFFICE RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 143 INTERNAL MEDICINE RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 4, 9 143A ENDOSCOPY RSF-3 RB-5 PT-1 WP-1 PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 2, 4 143B I.M. PRIVATE WORK RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 144 NEURO SHELL SPACE RSF-3 - ----EXP. NOTE: 11 145 ULTRASOUND RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 146 SHELL REHAB RSF-3 - ----EXP. NOTE: 11 147T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 148 READING RM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 149 RECEIVING / MORGUE SEALED RB-5 PT-1 ---ACT-1 150 ELECT. SEALED RB-5 PT-1 ---EXP. 151 EX MRI CASSETTE RSF-3 - ----EXT. NOTE: 11 152 RAD. TECH WORK AREA RSF-3 RB-5 PT-1 WP-1 PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 ` 152A SHELLED CT RSF-3 - ----EXP. NOTE: 11 201 OR 1 RSF-5 RB-4 PT-6/WP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 2, 14 202 OR 2 RSF-5 RB-4 PT-6/WP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 2, 12, 14 203 OR 3 RSF-5 RB-4 PT-6/WP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 2, 14 204 OR 4 RSF-5 RB-4 PT-6/WP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 2, 14 205 DIRTY PROCEDURE RSF-5 RB-4 PT-6/WP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 2, 14 206 FLUOROSCOPY OR RSF-5 RB-4 PT-6/WP-1 -PLAM-4 PLAM-6 ACT-4 NOTE: 2, 14 207A DIRTY STERILE PROCESSING RSF-5 RB-4 PT-6/WP-1 -PLAM-4 STAINLESS STEEL ACT-4 NOTE: 2, 4 207B CLEAN STERILE PROCESSING RSF-5 RB-4 PT-6/WP-1 -PLAM-4 STAINLESS STEEL ACT-4 NOTE: 2 208 XRAY RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 210 SURGERY SUITE RSF-3 RB-5 PT-1 FRP BEHIND RUNS AND/OR CAGES PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-1 NOTE: 2, 4, 10 210A TEAM WORK ROOM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 210B DOCTORS RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 211 COMMUNICATIONS CPT-1 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8, 9 212 OFFICE CPT-1 RB-6 PT-1 ---ACT-1 NOTE: 9 213 OFFICE CPT-1 RB-6 PT-1 ---ACT-1 214 WORK STATIONS CPT-1 RB-6 PT-1 ---ACT-1 NOTE: 9 215 OFFICE CPT-1 RB-6 PT-1 ---ACT-1 NOTE: 9 216 OFFICE CPT-1 RB-6 PT-1 ---ACT-1 NOTE: 9 217 CLINCAL MANAGERS CPT-1 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8, 9 218 MARKETING CLOSET CPT-1 RB-5 PT-1 ---ACT-1 219 CAT I-131 ANTE RM RSF-5 RB-3 PT-6 -PLAM-4 SSM-2 ACT-4 NOTE: 4 219A CAT I-131 RSF-5 RB-3 PT-6 FRP BEHIND RUNS AND/OR CAGES PLAM-4 PLAM-6/SSM-2 @ SINKS ACT-4 NOTE: 4, 10 220T RR RSF-1 RB-1 PT-1 WP-1 --ACT-2 NOTE: 3 221 DENTISTRY RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 4, 5 221A PRIVATE WORK RSF-3 RB-5 PT-1 ---ACT-1 NOTE: 8 221B DENTISTRY WK RM RSF-3 RB-5 PT-1 -PLAM-4 PLAM-6 ACT-1 NOTE: 8 222 JAN/FUR VAC SEALED RB-5 PT-1/FRP-1 ---EXP. NOTE: 7 FINISH SCHEDULE CODED NOTES 1. REFER TO FINISH PLANS FOR ACCENT WALL LOCATIONS AND FINISH EXTENTS. 2. INSTALL WALL PROTECTION (WP-1) ON ALL WALLS TO ALIGN WITH BACKSPLASH AT THIS LOCATION, SEE FINISH PLANS. 3. INSTALL WALL PROTECTION (WP-1) TO 48" AFF AT THIS LOCATION AS INDICATED ON FINISH PLANS UNLESS OTHERWISE NOTED. SEE FINISH PLANS FOR EXTENTS. 4. DROP IN STAINLESS STEEL SINK AT THIS LOCATION, REFER TO MEP DRAWINGS FOR FURTHER INFORMATION. 5. PROVIDE/INSTALL SHADE-1 AND SHADE-2 ON ALL EXTERIOR WINDOWS AT THIS LOCATION WITH BLACK OUT SIDE CHANNELS; PROVIDE/INSTALL FASCIA. 6. RSF-4 TO BE THE FLOORING AND CURBS OF RUNS. SEE DETAILS ON A5 SERIES. 7. INSTALL FRP PANELS ON ALL NOTED WALLS TO 48" A.F.F. 8. PROVIDE PRICING FOR ACT-6 AS AN ALTERNATE IN THIS LOCATION. 9. PROVIDE/INSTALL SHADE-1 ON ALL EXTERIOR WINDOWS AT THIS LOCATION; PROVIDE/INSTALL FASCIA. 10. INSTALL FRP PANELS ON ALL NOTED WALLS BEHIND CAGES AND RUNS TO 8' A.F.F. 11. FUTURE AREA -ORDER FLOORING FOR FUTURE OCCUPANCY AND STORE; DO NOT INSTALL. 12. FILM-3 AT EXTERIOR WINDOW AT THIS LOCATION, REFER TO A8 FLOOR FINISH PLAN FOR LOCATION AND EXTENTS. 13. PAINT STAIR RISERS, METAL BASE AND HANDRAILS PT-8 AT THIS LOCATION. 14. PLAM-6 AT PASS-THRU WINDOWS AT THIS LOCATION. 07/13/22