Loading...
HomeMy WebLinkAboutC2.3 STORM SEWER PROFILESSTORM SEWER 3 - 5 Profile Scale: 1"=30' Horiz. 1"=5' Vert. 875 880 885 890 895 900 875 880 885 890 895 900 0+00 1+002+00 2+25 TC 885.255 +48, CATCH BASIN PERDETAIL A/C2.2INV. 12" E 882.25100' ~ 12" @ 0.45%TC 884.454 +48, CATCH BASIN PERDETAIL A/C2.2INV. 12" E 881.67INV. 12" W 881.80INV. 12" S 881.75TC 883.123 +00, HEADWALL PER DETAILE/C2.2INV. 12" W 881.4548' ~ 12 " @ 0.45% EXISTING GRADE PROPOSED GRADE 1 1 2 2 STORM SEWER 4 - 6 Profile Scale: 1"=30' Horiz. 1"=5' Vert. 875 880 885 890 895 900 875 880 885 890 895 900 0+00TC 884.454 +48, CATCH BASIN PERDETAIL A/C2.2INV. 12" E 881.67INV. 12" W 881.80INV. 12" S 881.7556' ~ 12" @ 0.45% TC 884.506 +56, CATCH BASIN PERDETAIL A/C2.2INV. 12" N 882.00EXISTING GRADE PROPOSED GRADE 1 2 STORM SEWER EX2 - 2 Profile Scale: 1"=30' Horiz. 1"=5' Vert. 875 880 885 890 895 900 875 880 885 890 895 900 0+00 1+00 2+00TC 884.90EX2 +00, EXISTING CATCH BASININV. 12" E 881.75INV. 15" N 881.50INV. 15" S 881.50TC 885.201 +64, CATCH BASIN PERDETAIL A/C2.2INV. 12" W 882.04INV. 12" N 882.10+73, CATCH BASIN PERDETAIL A/C2.2INV. 12" S 882.59TC 885.502 64' ~ 12 " @ 0.45%110' ~ 12" @ 0.45% EXISTING GRADE PROPOSED GRADE INV. 15" N (INV. UNKNOWN)INV. S (SIZE AND INV. UNKNOWN)1 2 1 2 DRIVE CULVERT Profile Scale: 1"=30' Horiz. 1"=5' Vert. 875 880 885 890 895 875 880 885 890 895 0+001+00 1+25 71' ~ 12" @ 1.02% 1 2 R/W R/W ESMT ESMT ESMT ESMT ESMT R/W R/W 85.30 84.80 85.50 85.00 ME 85.25 84.75 85.43 84.93 ME 84.80 84.65 84.75 84.60 0.80%0.68%1.50%85.06 84.98 ME 84.98 84.90 ME 3 3 85.00 85.00 ME 85.33 85.33 ME 85.00 85.00 ME 85.86 ME 85.36 ME 85.30 ME 84.80 ME 84.85 84.85 ME 85.90 85.40 ME 85.48 85.363.27%4.10%4 4 4 4 X 1. PROVIDE RCP SEWER PIPE MATERIAL PER SPECIFICATION SECTION 33 40 00. 2. BACKFILL PER DETAIL E/C2.2. 3. TRANSITION TO FULL-HEIGHT CURB IN 1'-0" 4. TRANSITION TO FULL-HEIGHT CURB IN 10'-0" CODED NOTES: REVISION: PROJECT NUMBER: 20297 Sheet Name: © 2021 M+A Architects 04 MARCH 2022 DATE: SHEET NUMBER:RENOVATION AND ADDITIONMEDVET CARMEL - ANIMALHOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032STATUS: PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: 2021-0012 PROFILES STORM SEWER C2.3AWM AWM JDB W. 96TH STREET DETAIL 1"=10' A DRIVE DETAIL DETAIL 1"=10'B MAYFLOWER PARK RAMP DETAIL MAYFLOWER PARK DRIVE07/13/22