Loading...
HomeMy WebLinkAboutC2.4 EROSION CONTROL PLANXXXXXXXXXX. TC: 884.41 Inv. 12" N 882.01 Inv. 15" S 882.01 TC: 884.98 Inv. 10" E 883.23 TC: 884.92 Inv. Unable to Open TC: 884.90 Inv. Unable to Open TC: 884.41 Inv. 15" W 882.66 TC: 885.76 Inv. Unable to Open TC: 884.12 CO CO CO M M T T T T T Ex. End Section Inv. 881.42 Ex. End Section Inv. 881.28 Ex. End Section Inv. 880.88 Ex. End Section Inv. 881.12 Ex. End Section Inv. 880.90 Ex. End Section Inv. 882.38 Ex. End Section Inv. 881.65 Ex. End Section Inv. 882.43 Ex. End Section Inv. 882.40886884886886 886 886 88 6 8848 84 886 886886886886886887 884884886 886 886886884884884884 884 884 884884884 883883883 883883883883 882882 882882882882 883 88 6 886 887 8 8 7 8 88 8 8 8 8868878888858838 8 7 887 88 5 885885885885885 885885885885885885885 885885 8"W8"W8"WPL PL PL PLPLPLPLPLPL PLPL 2"W2"W 2"W 10"STM 12"STM15"STM15"STMSTMEEEESAN SAN SANWetland HC HC HC HC HC 12"STM12"STM12" STM 12" STM 12"STM DS DS DS CO CO 8"RD 8"RD 8"RD8"RD8"RD1 2 4 5 6 3 EX1 EX2 EX3 EX4 EX5 EX6 886 886886886 886 886 886886886 884 883 884883884885885884885885885 G 6"F 6"F6"F 6"F 12"STM PIV G G885 88 5 CONC. WASHSFSFSFSF SFSFSFSF SF SF SF SF S F SFSFSFSFSFSFSFSFSFSF SFSFSFPROPOSED BUILDING ADDITION EXISTING BUILDING EROSION AND SEDIMENT CONTROL LEGEND EXISTING PROPOSED DS 0 GRAPHIC SCALE SCALE IN FEET 30 60 90 INDEX CONTOUR INTERMEDIATE CONTOUR BUILDING/WALL STORM SEWER CATCH BASIN MANHOLE DOWNSPOUT ADAPTER GRADING/SEEDING LIMITS SILT FENCE PER DETAIL D/C2.5 INLET FILTER PER DETAIL C/C2.5 CONC. WASH CONCRETE WASHOUT PER DETAIL B/C2.5 REFER TO SHEET TOPOGRAPHIC SURVEY STM SF 800 799 REVISION: PROJECT NUMBER: 20297 Sheet Name: © 2021 M+A Architects 04 MARCH 2022 DATE: SHEET NUMBER:RENOVATION AND ADDITIONMEDVET CARMEL - ANIMALHOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032STATUS: PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: 2021-0012 PLAN EROSION CONTROL C2.4AWM AWM JDB STABILIZED CONSTRUCTION ENTRANCE PER DETAIL B/12 (C2.12) GENERAL NOTES: 1. A COPY OF THE SWPPP PLAN SHALL BE KEPT ONSITE AT ALL TIMES. 2. ANY EXISTING STORM INLETS IMPACTED BY THE NEW CONSTRUCTION ACTIVITY WILL NEED THE APPROPRIATE INLET PROTECTION FOR SEDIMENT CONTROL. 3. PROVIDE INLET SEDIMENT FILTER PER DETAIL C/C2.5 AT ALL EXISTING AND PROPOSED STORM INLET STRUCTURES RECEIVING FLOW FROM DISTURBED AREAS. 4. EROSION AND SEDIMENTATION CONTROL PRACTICES ARE SUBJECT TO FIELD MODIFICATION AT THE DISCRETION OF THE CITY OF CARMEL AND/OR THE INDIANA EPA. EXISTING WETLAND TO BE PROTECTED. NO GRADING OR CONSTRUCTION ACTIVITY TO BE PERFORMED IN THIS AREA. 07/13/22