E0.00 - ELECTRICAL SYMBOLS AND LEGENDS
LIGHTING SYMBOLS ELECTRICAL ABBREVIATIONSPOWER GENERAL NOTES APPLIES TO EACH POWER DRAWING LIGHTING GENERAL NOTES APPLIES TO EACH LIGHTING DRAWING SYMBOL LIST GENERAL INFORMATION POWER SYMBOLS FIRE ALARM SYMBOLS DEMOLITION GENERAL NOTES APPLIES TO EACH DEMOLITION DRAWING 1. REFER TO DRAWINGS AND SPECIFICATIONS OF OTHER CONSTRUCTION TRADES FOR ADDITIONAL ELECTRICAL WORK INCLUDED IN THIS CONTRACT. 2. COORDINATE EXACT LOCATIONS OF EQUIPMENT WITH OTHER CONSTRUCTION TRADES. VERIFY EXACT WIRING AND CONNECTION REQUIREMENTS WITH SUBMITTAL DOCUMENTS BEFORE INSTALLATION. SPECIALTY OUTLET TYPES SHALL BE VERIFIED BEFORE ORDERING. ALL ELECTRICAL WORK SHOWN HERE MUST BE VERIFIED AND COORDINATED IN FIELD BEFORE INSTALLATION. 3. REFER TO ARCHITECTURAL ELEVATIONS FOR OUTLET MOUNTING HEIGHTS. 4. EXACT LOCATIONS OF FLOOR RECESSED OUTLETS, FLOORBOXES, AND POKE-THRUS, SHALL BE COORDINATED WITH FURNITURE AND EQUIPMENT PLANS. OBTAIN LATEST PLANS FROM OWNERS REPRESENTATIVE. 5. ALL CONDUITS IN AREAS WITHOUT SUSPENDED CEILINGS SHALL BE RUN INCONSPICUOUSLY AS POSSIBLE, HIDDEN BEHIND BEAMS, CLOSE TO DECK, ETC. OBTAIN APPROVAL OF CONDUIT RUNS BELOW BEAMS WITH OWNER'S REPRESENTATIVE. 6. ALL DEVICES SHOWN ON THE EXTERIOR OF THE BUILDING SHALL BE WEATHERPROOF TYPE. ALL WEATHERPROOF RECEPTACLES HAVE WHILE-IN-USE COVERS UNLESS NOTED OTHERWISE 7. REFER TO ARCHITECTURAL DOOR SCHEDULES, AND DOOR HARDWARE SPECIFICATION FOR ELECTRICAL DEVICES INSTALLED AT DOORS. 8. PROVIDE ALL FINAL POWER CONNECTIONS TO EQUIPMENT. PROVIDE ALL CONDUIT, DEVICE BOXES, AND CONTROL WIRING TO EQUIPMENT UNLESS NOTED OTHERWISE. 9. RACEWAY SHALL RUN AS INCONSPICUOUSLY AS POSSIBLE. VERTICAL RUNS SHALL OCCUR IN CORNERS OF ROOMS. HORIZONTAL RUNS SHALL OCCUR ALONG BASEBOARD OF WALL WITH VERTICAL RUNS UP TO DEVICE BOXES BRANCHING OUT OF CORNER BOXES, TEES, ELBOWS AND ECT. 10. REFER TO ARCHITECTURAL PLANS FOR WALL CONSTRUCTION. 11. CIRCUIT NUMBER INDICATED WITH "GF" IS A CIRCUIT PROTECTED BY GROUND FAULT INTERRUPTING CIRCUIT BREAKER. 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF LUMINAIRES. COORDINATE WITH OTHER TRADES CONTRACTORS, IN ADVANCE OF INSTALLATION, TO AVOID CONFLICTS OF SUFFICIENT SPACE ABOVE CEILINGS FOR RECESSED LIGHTING FIXTURES. 2. REFER TO ARCHITECTURAL ELEVATIONS, CASEWORK, AND DETAILS, ELECTRICAL DETAILS, AND LUMINAIRE SCHEDULE FOR LUMINAIRE MOUNTING HEIGHTS AND ADDITIONAL INSTALLATION INFORMATION. 3. LOCATIONS OF LUMINAIRES IN ROOMS WITH MECHANICAL EQUIPMENT SHALL BE COORDINATED IN FIELD WITH INSTALLED EQUIPMENT. FIXTURES TO BE LOCATED OVER ACCESS PATHWAYS AROUND EQUIPMENT AND NOT OVER TOP OF EQUIPMENT OR DUCTWORK. DO NOT SUSPEND FIXTURES FROM PIPING OR DUCTWORK. PROVIDE APPROPRIATE MOUNTING HARDWARE AS REQUIRED TO SUPPORT FIXTURES. 4. SOME SWITCHED LIGHTING CIRCUITING NOT SHOWN FOR CLARITY. ALL FIXTURES WITHIN A SPACE ARE TO BE CONTROLLED FROM SWITCHES/OCCUPANCY/VACANCY SENSORS SHOWN IN THAT SPACE UNLESS NOTED OTHERWISE. 5. OCCUPANCY/VACANCY SENSOR POWER PACKS ARE NOT SHOWN FOR CLARITY REFER TO OCCUPANCY/VACANCY SENSOR WIRING DIAGRAMS. POWER PACKS TO BE LOCATED WITHIN EACH ROOM ABOVE CEILING ADJACENT TO ENTRY DOOR. PROVIDE CONDUIT AND WIRING FROM POWER PACK TO SENSOR UNITS. 6. INSTALL DRIVER FOR LUMINAIRES PROVIDED WITH REMOTE DRIVERS, IN NEAREST MECHANICAL ROOM WITH SUFFICIENT WALL SPACE. PROVIDE DRIVER WIRING SIZED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION FOR DISTANCE. 7. PROVIDE STEEL BRIDGING BETWEEN PURLINS/JOISTS/BEAMS AS NECESSARY TO SUPPORT THE WEIGHT OF SUSPENDED LUMINAIRES. 1. TURN OVER ANY SALVAGEABLE EQUIPMENT. 2. COORDINATE EXACT EXTENT OF DEMOLITION WITH ARCHITECTURAL DEMOLITION DRAWINGS. 3. COORDINATE PHASING OF DEMOLITION AND CONSTRUCTION PER DRAWINGS. 4. REMOVE ALL LIGHTING FIXTURES, DEVICES, OUTLETS, CONDUIT, CABLING, PANELS, AND EQUIPMENT WITHIN AREAS OF DEMOLITION. REMOVE WIRING AND CONDUIT BACK TO SOURCE OR LAST POINT OF CONNECTION TO REMAIN. 5. EXISTING EQUIPMENT OUTSIDE OF SCOPE OF WORK BOUNDARIES SHALL BE MAINTAINED. RECONNECT ANY CIRCUITS CUT PASSING THROUGH DEMOLITION AREAS. 6. REMOVE ALL UNUSED WIRING AND CABLES BACK TO THEIR SOURCE. REMOVE ALL UNUSED CONDUIT THAT IS EXPOSED OR ABOVE ACCESSIBLE CEILINGS WHICH IS AFFECTED BY OR IS IN THE AREA OF THE DEMOLITION WORK. 7. THE INTENTION OF THE ELECTRICAL DEMOLITION DRAWINGS IS TO DISCONNECT AND REMOVE ALL ELECTRICAL WORK MADE VOID BY THE SCOPE OF THE CONSTRUCTION AND ALTERATION. FIELD VERIFY EXACT MATERIAL QUANTITIES REQUIRED TO BE REMOVED. 8. WHERE BURIED CONDUITS EXTENDING OUT OF A CONCRETE SLAB BECOME ABANDONED, CUT AND GRIND THE CONDUITS OFF FLUSH WITH TOP OF SLAB AND PLUG WITH NON-SHRINK WATERPROOF GROUT FILL. 9. COORDINATE ALL DEMOLITION WORK WITH ALL OTHER TRADES. 10. LEGALLY DISPOSE OF HAZARDOUS MATERIALS AND BALLAST OR OTHER EQUIPMENT CONTAINING PCBS AND LAMPS CONTAINING MERCURY. COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS. VIF VERIFY IN FIELD WP 1/E.1 IT VC W INFORMATION TECHNOLOGY MEANS DETAIL No. 1, DRAWING SHEET "E1" WEATHERPROOF TYPE DEVICE VOLUME CONTROL WATTS FAA FIRE ALARM ANNUNCIATOR Ø OR P OC OR O/C RAF VFD VAV V UG UNO UH TFMR TV TYP RTU TCP SW OH PE PNL PVC P NTS NL NIC J LV MTD MCC +N MECH MCC MSB KVA KW LC KV KEC HID HVAC HP GF GRC G FLR FLUOR FS FACP FC FIXT VARIABLE FREQUENCY DRIVE DEVICE FROM FINISH FLOOR UNLESS OTHERWISE TEMPERATURE CONTROL PANEL UNLESS NOTED OTHERWISE RETURN AIR FAN TRANSFORMER ROOFTOP UNIT TELEVISION UNDERGROUND UNIT HEATER VARIABLE AIR VOLUME VOLTS TYPICAL SWITCH OVERHEAD NIGHTLIGHT ON CENTER NOT TO SCALE POLE (PHASE) NOT IN CONTRACT POLYVINYL CHLORIDE PNEUMATIC/ELECTRIC PHASE PANEL NOTED. HEATING, VENTILATION, AIR CONDITIONING GALVANIZED RIGID CONDUIT HIGH INTENSITY DISCHARGE GROUND FAULT INTERRUPTING PROTECTION KITCHEN EQUIPMENT CONTRACTOR INDICATES MOUNTING HEIGHT (N) TO CENTER OF JUNCTION BOX LIGHTING CONTACTOR LOW VOLTAGE KILOVOLT KILOWATTS MECHANICAL MOUNTED KILOVOLT AMPERE MOTOR CONTROL CENTER MAIN SWITCHBOARD MOTOR CONTROL CENTER FIRE ALARM CONTROL PANEL FAN COIL UNIT LIGHT FIXTURE FLUORESCENT FUSIBLE SWITCH HORSEPOWER GROUND FLOOR BUT ARE NOT LISTED BELOW. ABBREVIATIONS USED ON DRAWINGS IN GENERAL ARE LISTED BELOW. REFER TO CSI DOCUMENT TD-2-4 FOR ANY ABBREVIATIONS LISTED ON THE DRAWINGS EM EX EXP F EWC EMT DISTR ELEC EF CPT Cu AHU CCTV CUH CKT CATV BRKR C AC AFG AFF A CLOSED CIRCUIT TELEVISION CABLE ANTENNA TELEVISION CONTROL POWER TRANSFORMER ELECTRICAL METALLIC TUBING EXPLOSION PROOF TYPE DEVICE ELECTRIC WATER COOLER ELECTRICAL EMERGENCY EXISTING DISTRIBUTION EXHAUST FAN FUSE COPPER BREAKER CONDUIT AIR CONDITIONER ABOVE FINISH FLOOR ABOVE FINISH GRADE AIR HANDLER UNIT CABINET UNIT HEATER CIRCUIT AMPS LTG LIGHTING DLH DAYLIGHT HARVESTING FAP FIRE ALARM PANEL FARA FIRE ALARM REMOTE ANNUNCIATOR TR TAMPER RESISTANT NO. OF POLES -AS NOTED) "3R" DENOTES NEMA "3R" POLES -AS NOTED) "3R" DENOTES NEMA "3R" SITE LUMINAIRE (TYPE AND MOUNTING AS NOTED; SINGLE SERVICE PRE-WIRED MULTIPLE OUTLET RACEWAY MAGNETIC MOTOR STARTER (STARTER SIZE NO. OF DUPLEX RECEPTACLE; QUADRUPLEX RECEPTACLE FLEXIBLE CONDUIT OR CABLE -AS NOTED) "3R" DENOTES NEMA "3R" ENCLOSURE, CONDUIT ROUTED UNDER FLOORSPACE OR UNDERGROUND COMBINATION MOTOR STARTER (STARTER SIZE, FUSE SIZE, PANELBOARD: SURFACE MOUNTED, FLUSH MOUNTED TRANSFORMER: (SIZE AS NOTED OR IN TRANSFORMER SAFETY SWITCH (SWITCH SIZE, FUSE SIZE, NO. OF POLES SPECIAL PURPOSE RECEPTACLE (TYPE AS NOTED) DUPLEX RECEPTACLE, FLUSH IN FLOOR JUNCTION BOX, CEILING OR WALL MOUNTED EMERGENCY EGRESS LUMINAIRE T1 SCHEDULE) 1/25/3 P1 60/45/3 3R, NF 1/3 6-30R P1 J 3R M 3R S M F R1 R1 DISTRIBUTION PANELBOARD PANEL DESIGNATION AS SHOWN VARIABLE FREQUENCY DRIVE CONDUIT, RISER UP CONDUIT, RISER DOWN VOICE/DATA TERMINAL BOARD PUSHBUTTON STATION "NF" DENOTES NONFUSED OR IN SPECIFICATIONS) MANUAL MOTOR STARTER MOTOR (BY DIVISION 1-25) SIMPLEX RECEPTACLE; DUPLEX RECEPTACLE; ENCLOSURE "NF" DENOTES NONFUSED CONTROL PANEL ENCLOSURE "NF" DENOTES NONFUSED SEE LUMINAIRE SCHEDULE) R1 SEE DRAWINGS ---- ---- SEE DRAWINGS SEE DRAWINGS SEE DRAWINGS SEE DRAWINGS SEE DRAWINGS ---- ---- ---- 72" 60" 46" 60" 60" 46" 60" ---- ---- ---- ---- J SYMBOL DESCRIPTION NOTED OTHERWISE HEIGHT UNLESS MOUNTING VFD CP XX ; F ---- JUNCTION BOX WITH POWER CONNECTION TO ELECTRONIC FAUCET/DISPENSER 18" 46" (TYPE AND MOUNTING AS NOTED; SEE LUMINAIRE EMERGENCY LIGHTING BATTERY PACK W/INTEGRAL HEADS DUAL SERVICE FIELD WIRED MULTIPLE OUTLET RACEWAY W1 ; SCHEDULE)C1 SEE DRAWINGS 94" P1 ;B1; RECEPTACLE FOR EQUIPMENT AS INDICATED PS POWER SUPPLY ---- FLOOR RECESSED OUTLET BOX ---- FLOOR RECESSED / FIRE RATED "POKE THRU" OUTLET ASSEMBLY ---- HOME RUN BRANCH CIRCUIT (OVERHEAD)---- HOME RUN BRANCH CIRCUIT (UNDERFLOOR)---- ---- DUPLEX RECEPTACLE, WITH TWO USB PORTSU 18" COORD HT PR - PRINTER B - BLANKET WARMER CF - COPY/FAX MACHINE CM - COFFEE MAKER GD - GARBAGE DISPOSAL IM - ICE MACHINE M - MONITOR MW - MICROWAVE P - MEDICAL DISPENSER UNIT RF - FREEZER/REFRIGERATOR TV - TELEVISION OUTLET MOUNTED IN AV BOX UC - UNDER COUNTER REFRIG./FREEZER V - PATIENT VITALS MONITOR VD - VENDING MACHINE 18" 46" 18" 46" COORD HT COORD HT COORD HT COORD HT 58" SEE TECH COORD HT COORD HT 58" DH - DOOR HARDWARE ---- KE-* - KITCHEN EQUIPMENT; * DENOTES EQUIPMENT NUMBER COORD HT CW - CLOTHES WASHER 40" D - DIALYSIS UNIT COORD HT DEVICE SUFFIXES F C M AC WP WG FLOOR MOUNTED OUTLET CEILING MOUNTED OUTLET MODULAR FURNITURE OUTLET ABOVE COUNTER OUTLET WEATHER PROOF WIRE GUARD L LINE VOLTAGE TYPE W WALL MOUNTED S TOGGLE DISCONNECT SWITCH 46" LINE VOLTAGE SWITCH 2 - 2-POLE 3 - 3-WAY S 46" 4 - 4-WAY K - KEY OPERATED P - SWITCH WITH PILOT LIGHT TM - SWITCH WITH TIMER X EWC - ELECTRIC WATER COOLER 18" 1. SOME SYMBOLS MAY NOT BE USED. 2. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE. 3. STRAIGHT LINES BETWEEN DEVICES INDICATE CONTROLLED CIRCUIT. 4. DASHED SYMBOLS INDICATE EXISTING DEVICES TO BE REMOVED. 5. SOLID SYMBOLS WITH SUBSCRIPT "R" INDICATE EXISTING DEVICES TO REMAIN. 6. DASHED SYMBOLS WITH SUBSCRIPT "REL" INDICATE EXISTING DEVICES TO BE RELOCATED. 7. SOLID SYMBOLS WITH SUBSCRIPT "RD" INDICATE RELOCATED DEVICES. SYMBOL DESCRIPTION NOTED OTHERWISE HEIGHT UNLESS MOUNTING 18" JUNCTION BOX FOR EQUIPMENT AS INDICATEDJ X DW - DISHWASHER EH - EXHAUST HOOD H - ELECTRIC HAND DRYER ---- COORD HT DH - DOOR HARDWARE ---- HVAC - HVAC CONTROLS ---- KE-* - KITCHEN EQUIPMENT; * DENOTES EQUIPMENT NUMBER SEE KIT DWGS SPECIAL PURPOSE RECEPTACLE FOR EQUIPMENT AS INDICATED 4"RA - NEMA 6-50R; RANGE CD - NEMA 14-30R; CLOTHES DRYER 34" LOW VOLTAGE OCCUPANCY SENSOR, CEILING MOUNTEDOS CEILING LOW VOLTAGE VACANCY SENSOR, CEILING MOUNTEDVS CEILING VS - VACANCY SENSOR SWITCH 0 - OCCUPANCY SENSOR SWITCH M - MOMENTARY CONTACT SWITCH D - DIMMER D3 - 3 WAY DIMMER LV 46"LOW VOLTAGE SWITCH, 1 ZONE, 2 BUTTON, ON AND OFF LV 46"LOW VOLTAGE SWITCH AS INDICATED 2 - 2 ZONE, 4 BUTTON, ON AND OFF SC - 4 BUTTON SCENE SELECTOR D 46"LOW VOLTAGE SWITCH AS INDICATED D 46"LOW VOLTAGE DIMMER, 1 ZONE, 4 BUTTON, ON, OFF, RAISE, LOWER 2 - 2 ZONE, 6 BUTTON, ON/OFF, RAISE, LOWER SC - 4 BUTTON SCENE SELECTOR G - GRAPHIC USER INTERFACE ---- LUMINAIRE SCHEDULE) SHADED AREA DENOTES SHOWN) (TYPE AND MOUNTING AS NOTED; SEE "R2", "W2"; SEE LUMINAIRE SCHEDULE CEILING OR WALL MOUNTED LUMINAIRE TYPE EXIT SIGN FIXTURE (WITH DIRECTIONAL ARROWS AS W2R2 ; W2 X1 ; ; X1 SEE DRAWINGS 94" FACE RECEPTACLE CABLE DROP, REFER TO DETAIL J CEILING ON SHEET E7.01 QUADRUPLEX (DOUBLE DUPLEX) RECEPTACLE ;; GROUND FAULT INTERRUPTER ; X X ; MS - MOTORIZED SCREEN ---- WS - MOTORIZED WINDOW SHADES ---- S SWITCH FURNISHED BY OTHERS FOR EQUIPMENT AS INDICATED 46" SD - SMOKE DAMPER ---- SP - ELEVATOR SUMP PUMP; MOUNT IN PIT 46" FN - SYSTEM FURNITURE 18" MS - MOTORIZED SCREEN LUMINAIRE: TYPE "R1"; SEE LUMINAIRE SCHEDULE W1 CR CORD REEL CEILING SYMBOL DESCRIPTION NOTED OTHERWISE HEIGHT UNLESS MOUNTING FIRE ALARM MANUAL PULL STATION; K, KEY OPERATED TYPE CEILING MOUNTED FIRE ALARM SMOKE DETECTOR; DUCT MOUNTED FIRE ALARM SMOKE DETECTOR FL T ; FIRE ALARM MAGNETIC DOOR HOLDER FIRE ALARM FLOW SWITCH (BY DIVISION 22) FIRE ALARM TAMPER SWITCH (BY DIVISION 22) HEAT DETECTOR ---- ---- 72" ---- 48" FIRE ALARM VISUAL DEVICE COMBINATION FIRE ALARM AUDIBLE AND VISUAL DEVICE ---- LENS LOCATED DH S HS S ELEVATOR RECALLER ---- ≥ 6" FROM CEILING FIRE ALARM AUDIBLE DEVICE ≥ 90" TO TOP OF DEVICE WITHIN 80" TO 96" LENS LOCATED WITHIN 80" TO 96" TO TOP OF DEVICE * * = # OF DATA REQUIRED, SYMBOL WILL BE ON DATA SHEET * WITH QUANTITY * = # OF DATA REQUIRED, SYMBOL WILL BE ON DATA SHEET WITH QUANTITY J D PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 ELECTRICAL SYMBOLS AND LEGENDS 04 MARCH 2022 E0.00Stanley J. Kmonk Dustin J. Ruby Garrett W. Strauss MEDVET CARMEL -ANIMAL HOSPITAL650 MAYFLOWER PARK DRIVE|CARMEL, IN 46032RENOVATION AND ADDITIONELECTRICAL SHEET INDEX SHEET NUMBER SHEET NAME E0.00 ELECTRICAL SYMBOLS AND LEGENDS E0.01 ELECTRICAL SITE PLAN - ENABLING/DEMO E0.02 ELECTRICAL SITE PLAN - NEW WORK E1.01 FIRST FLOOR - DEMOLITION PLAN E1.02 SECOND FLOOR - DEMOLITION PLAN E2.01A FIRST FLOOR - LIGHTING PLAN AREA A E2.01B FIRST FLOOR - LIGHTING PLAN AREA B E2.01C FIRST FLOOR - LIGHTING PLAN AREA C E2.01D FIRST FLOOR - LIGHTING PLAN AREA D E2.02A SECOND FLOOR - LIGHTING PLAN AREA A E2.02B SECOND FLOOR - LIGHTING PLAN AREA B E2.02C SECOND FLOOR - LIGHTING PLAN AREA C E2.02D SECOND FLOOR - LIGHTING PLAN AREA D E2.02E SECOND FLOOR - LIGHTING PLAN AREA E E3.01A FIRST FLOOR - POWER PLAN AREA A E3.01B FIRST FLOOR - POWER PLAN AREA B E3.01C FIRST FLOOR - POWER PLAN AREA C E3.01D FIRST FLOOR - POWER PLAN AREA D E3.01M FIRST FLOOR - MECHANICAL POWER PLAN E3.02A SECOND FLOOR - POWER PLAN AREA A E3.02B SECOND FLOOR - POWER PLAN AREA B E3.02C SECOND FLOOR - POWER PLAN AREA C E3.02D SECOND FLOOR - POWER PLAN AREA D E3.02E SECOND FLOOR - POWER PLAN AREA E E3.02M SECOND FLOOR - MECHANICAL POWER PLAN E3.03 ROOF - POWER PLAN E4.01 ELECTRICAL ENLARGED PLANS E5.01 ELECTRICAL SCHEDULES E5.02 ELECTRICAL SCHEDULES E5.03 ELECTRICAL SCHEDULES E5.04 ELECTRICAL SCHEDULES E6.01 ONE LINE DIAGRAM - EXISTING E6.02 ONE LINE DIAGRAM - NEW WORK E6.03 ONE LINE SCHEDULES E6.04 ONE LINE SCHEDULES E7.01 ELECTRICAL DETAILS E7.02 ELECTRICAL DETAILS E7.03 ELECTRICAL DETAILS 07/13/22