Loading...
HomeMy WebLinkAboutE0.01 - ELECTRICAL SITE PLAN - ENABLING_DEMODUMPSTER PAD EX. GRASS EX. GRASS EX. GRASS EX. GRASS EX. GRASS EX. GRASS EX. GRASS EX. GRASS EX. GRASS MAYFLOWER PARK SIGN EX. GRASS VET CLINIC SIGN 15" CMP P.O.B. PARCEL 1 EXCEPTION RIPRAP LIFT STATION RIPRAP14' GRAVELDRIVEW. 96TH STREET (PUBLIC R/W)MAYFLOWER PARK DRIVE (PRIVATE STREET)PER PLAT, INST. #2000-45586 SEC. 7-17-03 80' Stri p per Quitclaim Inst. No. 2014-053577 75' U.&D.E. P.O.B. PK NAIL FOUND FLUSH PK NAIL FOUND FLUSH CAPPED REBAR FOUND FLUSH AT PROP. CORNER . POND POND WM Site Address: 9650 Mayflower Park Drive Carmel, Indiana 46032 RETAINING WALL EXISTING SWALE STMCO WOODS WOODS WOODS WOODS 15' B.S.L. 15' B.S.L.15' B.S.L.IRVING MATERIALS, INC. INST. NO. 9913085 KRUSE PROPERTIES, LLC. INST. NO. 2007-19093 MAYFLOWER PARK ASSOC. EX. CONCRETE ASPH. PAVEMENT ASPH. PAVEMENT ASPH. PAVEMENT ASPHALT ASPHALT ASPHALT 6" CONC. CURB 6" CONC. CURB 6"CONC.CURBASPHALT 10' AMERITECH EASEMENT IN.#'9709748111, B-2(#14) 30' DRAIN. ESMT. PER PLAT 30' DRAIN. ESMT. PER PLAT 80.00' I./E/ ESMT. U.&D.E. & S.E PER PLAT. 30' GAS LN.ESMT .INST. #9709741841B-2(#12) EXISTING SWALE EX. ROAD CENTERLINE EXISTING BUILDING 1 STY. CONCRETE BLOCK10,133 SQ. FEETBUILDING HT.: 34.7' 6" CONC. CURB EX. GUARDRAIL S 90°00'00" E 475.01' N 76°47'08" W 499.98'N 00°12'00" E414.21'S 01°06'55" E528.61'15' B.S.L.602.58' 24.9'36.2' Glennco Realty LLC1175.6' 1161.2' 1775.3' 5.6 ' 1017.59'N 00°12'00" E50.00'S 90°00'00" E 70.00' S 90°00'00" E 10.00'N 00°12'00" E380.95'73.25' 426.73' LOT 3 BLOCK 1 Area less Exception: 4.953 Ac.+/- 2 3 1 4 4 5 5 5 PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 ELECTRICAL SITE PLAN - ENABLING/DEMO 04 MARCH 2022 E0.01Stanley J. Kmonk Dustin J. Ruby Garrett W. Strauss MEDVET CARMEL -ANIMAL HOSPITAL650 MAYFLOWER PARK DRIVE|CARMEL, IN 46032RENOVATION AND ADDITION60' 90'30' 0 SITE PLAN SCALE: 1" = 30'-0" 1 ELECTRICAL SITE PLAN EXISTING N CODED NOTES 1. REMOVE EXISTING UTILITY COMPANY TRANSFORMER AND RELOCATE EXISTING NATURAL GAS EMERGENCY GENERATOR. 2. PROVIDE NEW CONRETE PAD FOR TEMPORARY LOCATION OF RELOCATED EXISTING EMERGENCY GENERATOR. 3. 200 AMP, 208/120 VOLT, 3 PHASE EMERGENCY FEEDER. ROUTE THROUGH BUILDING TO AUTOMATIC TRANSFER SWITCH IN EXISTING MAIN ELECTRICAL ROOM. PROVIDE CONTROL WIRING FOR GENERATOR. 4. EXISTING SITE LIGHTING POLE AND BASE TO REMAIN. FIXTURE HEAD IS TO BE DEMOLISHED. CONTRACTOR TO VERIFY IN FIELD POLE HEIGHT. 5. EXISTING SITE LIGHTING POLE/BASE AND FIXTURE HEAD TO BE DEMOLISHED. 07/13/22