Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E0.02 - ELECTRICAL SITE PLAN - NEW WORK
T T PED T PED T POND Wetland W. 96TH STREET (PUBLIC R/W)MAYFLOWER PARK DRIVE (PRIVATE STREET)PER PLAT, INST. #2000-45586POND POND WM Site Address: 9650 Mayflower Park Drive Carmel, Indiana 46032 RETAINING WALL EXISTING SWALE STMCO EX. RIGHT-OF-WAY WOODS WOODS WOODS WOODS 15' B.S.L. 15' B.S.L.15' B.S.L.KRUSE PROPERTIES, LLC. EX. CONCRETE ASPH. PAVEMENT ASPH. PAVEMENT ASPH. PAVEMENT ASPH. PAVEMENT ASPH. PAVEMENT ASPHALT ASPHALT ASPHALT 6" CONC. CURB 6" CONC. CURB6"CONC.CURBASPHALT 12 5 11 10' AMERITECH EASEMENT IN.#'9709748111, B-2(#14) 30' DRAIN. ESMT. PER PLAT 80.00' I./E/ ESMT. U.&D.E. & S.E PER PLAT. 15' U.& D.E. & TCG ESMT. IN.#'9809839555 30' GAS LN. ESMT.INST. #9709741841B-2(#12) EXISTING SWALE EX. ROAD CENTERLINE EXISTING BUILDING 1 STY. CONCRETE BLOCK10,133 SQ. FEETBUILDING HT.: 34.7' 6" CONC. CURB EX. GUARDRAIL LOT 3 BLOCK 1 Area less Exception: 4.953 Ac.+/- LOT 2 BLOCK 1 -MAYFLOWER PARK MORIDEN AMERICA INC. INST. NO. 2014-45483 LOT 1 BLOCK 7 PERFORMANCE SERVICES REAL ESTATE LLC INST. #2015-25148 80' Strip per Quitclaim Inst. No. 2014-053577 75' U.&D.E. PK NAIL FOUND FLUSH PK NAIL FOUND FLUSH CAPPED REBAR FOUND FLUSH AT PROP. CORNER MSE CAPPED REBAR FOUND FLUSH 0.38' EAST & 0.12' SOUTH OF PROP. CORNER . PROPOSED BUILDING ADDITION STMSTMSTM STM STMRD RD RDRDRDDS DS DS CO CO 3 1 4 2 6 7 9 8 P2 P2 P1 P1 P1 P1 P1 P1 P1 L1-2 10 10 PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 ELECTRICAL SITE PLAN - NEW WORK 04 MARCH 2022 E0.02Stanley J. Kmonk Dustin J. Ruby Garrett W. Strauss MEDVET CARMEL -ANIMAL HOSPITAL650 MAYFLOWER PARK DRIVE|CARMEL, IN 46032RENOVATION AND ADDITIONN 60' 90'30' 0 SITE PLAN SCALE: 1" = 30'-0" 1 ELECTRICAL SITE PLAN NEW CODED NOTES 1. PROVIDE NEW CONCRETE PAD FOR NEW UTILITY COMPANY TRANSFORMER. 2. PROVIDE 2 -5" UNDERGROUND CONDUITS FOR UTILITY COMPANY PRIMARY CABLING. 3. PROVIDE 1600 AMP SERVICE INTO NEW ELECTRICAL ROOM. 4. PROVIDE 300 KW, 480/277 VOLT, DIESEL EMERGENCY GENERATOR. 5. PROVIDE EMERGENCY FEEDERS TO ELECTRICAL EQUIPMENT. 6. REFEED IN PHASE 2. 7. EXISTING MAIN ELECTRICAL ROOM. 8. 3 WAY MANUAL TRANSFER SWITCH FOR GENERATOR MAINTENANCE. 9. NEW MEP ROOM WITH LIFE SAFETY ATS. 10. REUSE EXISTING POLE AND BASE. ONLY PROVIDE P1 FIXTURE HEAD AT THIS LOCATION. POLE HEIGHT IS ESTIMATED AT 20-25 FEET. CONTRACTOR SHALL VERIFY POLE HEIGHT IN FIELD PRIOR TO ORDERING. 07/13/22