HomeMy WebLinkAboutE7.01 - ELECTRICAL DETAILSDEPTH OF DUCTBANK MAY VARY - COORDINATE IN FIELD EXACT SIZE AND QUANTITY OF CONDUITS MAY VARY. REFER TO SITE PLAN NOTES. DUCTBANK SECTION N.T.S. 120 VOLT DUPLEX OUTLETS LOCATED WHERE SHOWN ON THE PLANS JUNCTION BOX FLUSH IN WALL GROMMETED OPENING TO JUNCTION BOX 2" LONG DEVICE SECTION RACEWAY COVERS (TYPICAL) C SINGLE SERVICE MULTI-OUTLET SURFACE RACEWAY N.T.S. DETAIL 2 1/4" 2 1/4" MOUNTING HEIGHT TO BE ABOVE COUNTER BACK SPLASH OR DESK (HEIGHT VARIES)-COORDINATE IN THE FIELD 3/4" CONDUIT WITH BRANCH CIRCUITS (QUANTITY SHOWN ON DRAWINGS)POWER WIRING CEILING FLOOR FIXTURE TYPE X Y Z P2 P1 36" 2" 24"72" 24"72" 90% COMPACTED BACKFILL NATURAL SOIL OR 4" CRUSHED GRAVEL CONCRETE PER SECTION 3300 SPACERS (TYPICAL) TO CORNERS OF DUCT DUCT SPACERS 3"3" 3" GRADE CONCRETE ENCASEMENT CAUTION TAPE CONDUIT 30" B.F.G. #8 WIRE HOOPS 16" ON CENTER CONTINUOUS RUN OF 18" AS REQUIRED #4 REBAR ATTACHED WIDTH (NOT REQUIRED BENEATH BUILDING SUB ON GRADE) A SAFETY BOLLARD N.T.S. DETAIL B EXTERIOR ELECTRICAL EQUIPMENT CONCRETE BASE N.T.S. DETAIL D ABOVE CAGE RACEWAY N.T.S. DETAIL F DEVICE COORDINATION N.T.S. DETAIL H INTERIOR ELECTRICAL EQUIPMENT CONCRETE BASE N.T.S. DETAIL G DETAIL I GROUNDING BUSBAR AT SWITCHBOARD N.T.S. DETAIL J CABLE DROP N.T.S. DETAIL E LIGHTING FIXTURE/RECEPTACLE AT ROOFTOP EQUIPMENT N.T.S. DETAIL K POLE MOUNTED LUMINAIRE BASE N.T.S. DETAIL FILL PIPE WITH CONCRETE SMOOTH AND BEVEL ON TOP 6" ENVELOPE OF CONCRETE AROUND PIPE SMOOTH AND BEVEL CONCRETE 2" ABOVE EXISTING GRADE 40 STEEL PIPE 6" DIA. SCHEDULE 4' 4' 2"GRADE GRADE X X X EQUIPMENT EMERGENCY GENERATOR6" PLAN DIMENSION AS REQ'D FOR EQUIPMENT (COORDINATE W/APPROVED SHOP DRAWINGS) @ MID-DEPTH #4@8" E.W. UTILITY TRANSFORMER6" SHELF RACEWAY CAGE CAGE LIGHT SWITCHES SHALL BE LOCATED WITHIN 12" OF THE STRIKE DEVICES SHALL BE ALIGNED VERTICALLY. OFFSET CONDUITS SIDE OF DOOR FRAME, OR IF NOT POSSIBLE, THEN WITHIN 12" OF WITHIN WALL AS NECESSARY. THE OPEN DOOR SWING ON HINGE SIDE WALL. PHONE/DATA/VIDEO OUTLETS SHALL BE LOCATED IMMEDIATELY ADJACENT TO DUPLEX RECEPTACLES. 5. 3. 4. 1. ALL SIMILAR DEVICES SHALL BE GANGED TOGETHER WHERE POSSIBLE. NOTES ALL WIRING DEVICE PLATES SHALL BE OF THE SAME COLOR AND STYLE.2. FINISHED FLOOR 20" 54" 80" 94" EXIT EXIT SIGN DOOR FIRE ALARM THERMOSTAT AUDIBLE/VISUAL DEVICE OCCUPANCY RECEPTACLE PHONE/DATA OUTLET SWITCHES/DIMMER CL SENSORS ALIGN48" DIMENSIONS AS REQUIRED FOR 6 X 6-W1.4/W1.4 W.W.F. EQUIPMENT (COORDINATE WITH APPROVED SHOP DRAWINGS) 2" NOMINAL NOMINAL 4" SECTION 03300. FLOOR SLAB CONCRETE PER #4/0 #6, 3/4" C. TERMINAL BOARDS TO MTR & TR TELEPHONE ELECTRODE SYSTEM OUT TO GROUNDING COLD WATER CONNECTION TO METALLIC PIPE MAIN SWITCHBOARD MAIN GROUND BUS OF BUILDING TO METAL FRAME GROUND BUSBAR SINGLE POINT (TYPICAL) EXOTHERMIC WELD SURGE PROTECTOR TRANSIENT VOLTAGE UNIT CLAMP TO REBAR IN FOOTING "UFER" GROUND CONNECTION MINIMUM 20' OF REBAR OUTLET TYPE. REFER TO PLANS FOR RUBBER DEVICE BOX - TYPE "SO" CABLE CONDUIT STRAIN JUNCTION BOX RELIEF GRIP. STRUCTURAL DECK 6" WEATHERPROOF EQUIPMENT DISCONNECT SWITCH SUPPORTS AS REQUIRED ROOF CURB 3/4" RIGID C. WEATHERPROOF GROUND FAULT DUPLEX RECEPTACLE. LED VAPORTIGHT LUMINARE WITH GUARD THREE-WAY WEATHERPROOF LIGHT SWITCH - LOCATE OTHER SWITCH AT ROOF HATCH TYPICAL ROOF MOUNTED MECHANICAL EQUIPMENT Z 30" Y X 1" CHAMFER CYLINDRICAL CONCRETE BASE WITH SIX #6 VERTICAL REINFORCING BARS AND #3 HORIZONTAL TIES AT 12" ON CENTER WIRE TIED TOGETHER AT 3" IN FROM OUTSIDE CONCRETE SURFACE. 1" CONDUIT WITH BRANCH CIRCUIT AS SHOWN ON THE DRAWINGS EXOTHERMIC WELD CONNECTION 1/2" X 8' DRIVEN GROUND ROD #2 AWG COPPER GROUNDING CONDUCTOR FINISHED GRADE SMOOTH FINISH ON EXPOSED SURFACE ANCHOR BOLTS, BOLT SIZE, PROJECTION AND BOLT CIRCLE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION GROUNDING CONDUCTOR CONNECTION TO POLE POLE WITH ANCHOR BOLT COVERS NON-SHRINK GROUT X X X PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 ELECTRICAL DETAILS 04 MARCH 2022 E7.01Stanley J. Kmonk Dustin J. Ruby Garrett W. Strauss MEDVET CARMEL -ANIMAL HOSPITAL650 MAYFLOWER PARK DRIVE|CARMEL, IN 46032RENOVATION AND ADDITION07/13/22