E7.03 - ELECTRICAL DETAILS
N.T.S. IC IC PS GENERAL NOTES 1. PROVIDE NON-ADDRESSIBLE INITIATING DEVICES (SMOKE OR HEAT DETECTOR) WHERE DEVICES ARE LOCATED IN UN-HEATED SPACES. LOCATE ASSOCIATED ZONE MODULE IN HEATED SPACE. 2. ALL CONDUIT TO BE RIGID GALVANIZED STEEL, AND ALL BOXES NEMA 4 RATED, ALL LIGHT FIXTURES TO BE WET LOCATION LISTED, ALL OUTLETS AND DEVICES TO HAVE WET LOCATION WHILE-IN-USE COVERS IN ELEVATOR MACHINE ROOM AND HOIST WAY. 3. COORDINATE EXACT LOCATION OF DEVICES IN PIT AND HOIST WAY WITH ELEVATOR INSTALLATION DRAWINGS PRIOR TO ROUGH-IN. 4. LOCATE ELEVATOR DISCONNECT AND CAB LIGHTS/REC/HVAC DISCONNECT IMMEDIATELY ADJACENT TO DOOR ENTERING MACHINE ROOM. 5. PROVIDE AUXILIARY CONTACTS IN ELEVATOR DISCONNECT WHEN BATTERY LOWERING SYSTEM IS PROVIDED. WIRE COMPLETE TO ELEVATOR CONTROLLER. 6. ALL DISCONNECTS SHALL BE LOCKABLE IN THE OPEN POSITION. 7. PROVIDE CABLING FOR TRANSFER AND PRE-TRANSFER FROM ELEVATOR CONTROLLER TO ATS. ELEVATOR POWER UNIT CODED NOTES 1. SMOKE DETECTOR SHALL ACTIVATE ILLUMINATED VISUAL AND AUDIBLE SIGNAL (FIREMAN'S HELMET) IN ELEVATOR CAB, AND INITIATE RECALL TO PRIMARY RECALL FLOOR. 2. SMOKE DETECTOR SHALL ACTIVATE ILLUMINATED VISUAL AND AUDIBLE SIGNAL (FIREMAN'S HELMET) IN ELEVATOR CAB, AND INITIATE RECALL TO ALTERNATE RECALL FLOOR. 3. FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE RELAY TO ACTIVATE AUDIBLE/VISUAL (FIREMAN'S HELMET) SIGNAL TO ELEVATOR CONTROL PANEL. 4. FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE RELAY TO ACTIVATE ELEVATOR PRIMARY RECALL SIGNAL TO ELEVATOR CONTROL PANEL. 5. FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE RELAY TO ACTIVATE ELEVATOR SECONDARY RECALL SIGNAL TO ELEVATOR CONTROL PANEL. 6. FUSIBLE ELEVATOR CAB DISCONNECT SWITCH TO SERVE CAB LIGHTS, RECEPTACLE AND EXHAUST FAN (IF APPLICABLE). PROVIDE 30 AMP, SINGLE POLE, FUSIBLE DISCONNECT WITH 15 AMP FUSES. 7. FUSIBLE ELEVATOR DISCONNECT SWITCH WITH INTEGRAL SHUNT TRIP OPERATOR. SHUNT TRIP CIRCUIT SHALL BE N.C. MECHANICALLY INTERLOCKED AUXILIARY CONTACT. PROVIDE SUPERVISORY FIRE ALARM MONITORING OF POWER SOURCE TO SHUNT TRIP OPERATOR. 8. VAPORTIGHT LIGHT FIXTURE AND SWITCH. LOCATE SWITCH NEAR ENTRY TO SPACE. (TYPICAL) 9. NON-GF SIMPLEX OUTLET FOR SUMP PUMP. 10. DUPLEX GF OUTLET. 11. VOICE OUTLET WITH 2 ANALOG TELEPHONE LINES TIED TO ELEVATOR CONTROLLER. 12. TWO-WAY ADA ELEVATOR INTERCOM COMMAND STATION IN MAIN EGRESS FLOOR ELEVATOR LOBBY. 13. TWO-WAY ADA ELEVATOR INTERCOM CALL STATION IN EACH ELEVATOR LOBBY. 14. 135° F HEAT DETECTOR LOCATED WITHIN 2' OF EACH 165° F SPRINKLER HEAD FOR SHUNT TRIP OPERATION IN ELEVATOR DISCONNECT. VERIFY THAT RATING IS LESS THAN THE RATING OF THE SPRINKLER. 15. FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE TO MONITOR ELEVATOR SHUNT TRIP CIRCUIT IN ELEVATOR DISCONNECT AND INDIVIDUAL ADDRESSABLE MODULE RELAY TO ACTIVATE ELEVATOR SHUNT TRIP. 16. NON-FUSED DISCONNECT WITH AUXILIARY CONTACTS FOR BATTERY LOWERING SYSTEM. WIRE TO ELEVATOR CONTROL PANEL. PROVIDE LABEL PER NEC 620.52(B). H S S S H S F ELEVATION ELEVATOR CONTROLLER SPACE FOR "MACHINE-ROOM-LESS" WITH CONTROLLER IN DOORWAY 1 2 SPRINKLER HEAD (TYPICAL) HOIST WAY HOIST WAY PIT TOP OF HOIST WAY ELEVATOR CONTROL PANEL ROOF ELEVATOR LANDING (TYPICAL) ELEVATOR CONTROL SPACE DOOR 14 1 1 2 8 10 9 13 5 10 4 3 11 6 7 15 1 13 12 C UL LISTED THROUGH WALL PENETRATION N.T.S. DETAILA UL LISTED THROUGH WALL PENETRATION N.T.S. DETAIL D UL LISTED THROUGH WALL PENETRATION N.T.S. DETAIL B UL LISTED THROUGH WALL PENETRATION N.T.S. DETAIL E TYPICAL MACHINE ROOMLESS ELEVATOR REQUIREMENTS N.T.S. ELEVATION System No. W-L-3334 SECTION A-A A A C R US 1A 1B 3 4 2 Hilti Firestop Systems System No. C-AJ-3180 SECTION A-A A A 5 2 3 4 1 Hilti Firestop Systems C R US System No. W-L-2075 SECTION A-A A A F Rating Hr 1 2 T Rating Hr 0 2 Fill Mtl Depth In. 5/8 1-1/4 2 3 4 1A 1B Hilti Firestop Systems R System No. W-L-1054 SECTION A-A A A 3 2 1B 1A Hilti Firestop Systems C R US 1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600 2400 kg/m3) concrete floor or min 4-3/4 in. (121 mm) thick reinforced lightweight or normal weight concrete wall. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 6 in.(152 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 2. Steel Sleeve — (Optional) — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe cast or grouted into floor or wall assembly, flush with floor or wall surfaces. 3. Cables — Aggregate cross-sectional area of cables in opening to be max 45 percent of the aggregate cross-sectional area of the opening. Cables to be rigidly supported on both sides of floor or wall assembly. Any combination of the following types and sizes of metallic conductor or fiber optic cable may be used: A. Max 500 kcmil single copper connector power cable with thermoplastic insulation and polyvinyl chloride (PVC) j Jacket. B. Max 300 pair No. 24 AWG copper conductor telecommunication cables with polyvinyl chloride (PVC) insulation and jacket material. C. Max 7/C copper conductor No. 12 AWG multiconductor power and control cables with polyvinyl chloride (PVC) or cross-linked polyethylene (XLPE) insulation and PVC jacket. D. Multiple fiber optical communication cables jacketed with PVC and having a max outside diam of 1/2 in. (13 mm). E. Max 3/C copper conductor No. 12 AWG with bare aluminum ground, polyvinyl chloride (PVC) insulated steel, Metal-clad cable. F. Max 3/C with ground 2/0 AWG copper conductor SER cable with cross-linked polyethylene (XLPE) insulation and polyvinyl chloride (PVC) jacket. G. RG/U coaxial cable with polyethylene (PE) insulation and polyvinyl chloride (PVC) jacket having a max outside diameter of ½ in. (13 mm) H. Fire Resistive Cables* - Max 1-1/4 in. (32 mm) diam single conductor or multi conductor Type MI cable. A min 1/8 in. (3 mm) separation shall be maintained between MI cables and any other types of cable. 4. Packing Material — Min 4-1/4 in. (108 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor to accommodate the required thickness of fill material. 5. Fill, Void or Cavity Material* — Sealant — Min 1/4 in. (6.4 mm) thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant. *Bearing the UL Classification Mark 1. Floor or Wall Assembly -- The fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. B. Gypsum Board* -- Nom 5/8 in. thick gypsum wallboard, as specified in the individual Wall and Partition Design. Max diam of opening is 4 in. 2. Metallic Sleeve -- (Optional) -- Nom 4 in. diam (or smaller) Schedule 40 (or thinner) steel pipe cast into wall assembly with joint compound and installed flush with wall surfaces. 3. Electrical Nonmetallic Tubing+ -- Nom 2 in. diam (or smaller) corrugated wall electrical nonmetallic tubing (ENT) constructed of polyvinyl chloride (PVC). Tubing to be rigidly supported on both sides of wall assembly. A nom annular space of 3/4 in. is required within the firestop system. See Electrical Nonmetallic Tubing (FKHU) category in the Electrical Construction Materials Directory for names of manufacturers. 4. Fill, Void or Cavity Material* -- Sealant -- Installed symmetrically on both sides of the wall. The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. Fill material applied within the annulus, flush with each end of the steel sleeve at the thickness shown in the table below: 1. Wall Assembly -- The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw-attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. wider and 4 to 6 in. higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* -- 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 32-1/4 in. for steel stud walls. Max diam of opening is 14-1/2 in. for wood stud walls. The F Rating of the firestop system is equal to the fire rating of the wall assembly. 2. Through-Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2-1/4 in. Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -- Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe -- Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -- Sealant -- Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe wall interface on both surfaces of wall . HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-One Sealant *Bearing the UL Classification Mark 3. Firestop Device* — Firestop device consists of a corrugated steel tube with an inner plastic housing, intumescent material rings and twisted inner fabric smoke seal. Firestop device to be installed in accordance with the accompanying installation instructions. As an option, the inner fabric seal may remain open except that, to attain the L Rating, the inner fabric seal shall be twisted to completely close off the opening within device. Device slid into wall such that ends project an equal distance from the approximate centerline of the wall assembly. The annular space between the device and the periphery of the opening shall be min 0 in. (point contact). Device provided with flanges that are spun clockwise onto device threads, butting tightly to both sides of wall. Device flanges are optional. When the device flanges are not used, the T, FT and FTH Ratings for the firestop system are 0 hr. For blank opening (no cables), the T, FT and FTH Ratings for the firestop system equal the F and FH Ratings only when the device flanges are used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 653 2" Speed Sleeve and CP 653 4" Speed Sleeve 4. Fill, Void or Cavity Material* - Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus between firestop device and wall, flush with both surfaces of wall, and an additional 1/4 in. (6 mm) bead applied around periphery of device. When device flanges are used, gypsum drywall compound may be used in place of the fill material. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE or CP 606 Sealant *Bearing the UL Classification Mark 1. Wall Assembly — The 1, 2, 3 or 4 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described within the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall incorporate the following construction features: A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC for 1 and 2 hr wall assemblies. Steel Studs to be 3-5/8 in. (92 mm) for 3 and 4 hr wall assemblies. B. Gypsum Board* — Nom 5/8 in. (16 mm) thick gypsum board as specified in the individual Wall and Partition Design. Opening in gypsum board to be max 2-1/2 in. (64 mm) diam for 2" device and max 4-1/2 in. (114 mm) diam for 4" device. The hourly F and FH Ratings of the firestop system are dependent upon the hourly rating of the wall in which it is installed. 2. Cables — Within the loading area for each firestop device, the cables may represent a 0 to 100 percent visual fill. Cables to be tightly bundled within the device and rigidly supported on both sides of wall assembly. Any combination of the following types of cables may be used: A. Max 100 pair No. 24 AWG (or smaller) copper conductor telecommunication cable with polyvinyl chloride (PVC) jacketing and insulation. B. Max 7/C No. 12 AWG copper conductor control cable with PVC or XLPE jacket and insulation. C. Max 4/0 AWG Type RHH ground cable. D. Max 4 pr No. 22 AWG Cat 5 or Cat 6 computer cables. E. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing. F. Fiber optic cable with polyvinyl chloride (PVC) or polyethylene (PE) jacket and insulation having a max diam of 1/2 in. (13 mm). G. Max 20/C No. 22 AWG shielded printer cable with PVC jacket. H. Through-Penetrating Product* - Two copper conductors No. 18 AWG (or smaller) Power or Non Power Limited Fire Alarm Cable with or without a jacket under a metal armor. AFC CABLE SYSTEMS INC I. Max. 1/4 in. (6 mm) diameter S-Video Cable consisting of 2 max 24 AWG 75 ohm coax or twisted pair cable with PE insulation and PVC jacket . J. Max 3/C No 12 AWG MC Cable. K. Through Penetrating Product* — Any cables, Armored Cable+ or Metal Clad Cable+ currently Classified under the Through Penetrating Product category. See Through Penetrating Product (XHLY) category in the Fire Resistance Directory for names of manufacturers. For opening with cables, when the hourly rating of the wall assembly is 1 hr, the T, FT and FTH Ratings are 0 hr. For opening with cables, when the hourly rating of the wall assembly is 2 hr, the T, FT and FTH Ratings are 1-3/4 hr except that, when Item 2C, 2G, 2I, 2J or 2K is used, the T, FT and FTH Ratings are 1 hr for 2C, 2 OR 2I and the T, FT and FTH Ratings are 1/2 hr for 2J or 2 K (see Item 3 also). When the hourly rating of the wall assembly is 3 or 4 hr, the T, FT and FTH Ratings are 2 hr. For wall assemblies with a 3 or 4 hr rating, Items 2G and 2I are not to be used. L Ratings apply only when device flanges and CP 606 or FS-One Sealant are used. See Table below for L Ratings. Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 ANSI/UL1479 (ASTM E814) CAN/ULC S115 F Ratings - 1, 2, 3 and 4 Hr (See Item 1)F Ratings - 1, 2, 3 and 4 Hr (See Item 1) T Ratings - 0, 1, 1-3/4, 2, 3 and 4 Hr (See Items 2 and 3) FT Ratings - 0, 1, 1-3/4, 2, 3 and 4 Hr (See Items 2 and 3) L Rating At Ambient - Less Than 1 CFM (See Item 2)FH Ratings - 1, 2, 3 and 4 Hr (See Item 1) L Ratings At 400 F - 1 and Less Than 1 CFM (See Item 2) FTH Ratings - 0, 1, 1-3/4, 2, 3 and 4 Hr (See Items 2 and 3) L Rating At Ambient - Less Than 1 CFM (See Item 2) L Ratings At 400 F - 1 and Less Than 1 CFM (See Item 2) Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. March 14, 2012 Max Cable Fill Cable Type L Rating, CFM/Sq Ft L Rating, CFM Ambient 400°F Ambient 400°F 0%- Less Than 1 Less Than 1 Less Than 1 Less Than 1 100% Item 2D only 5 1 Less Than 1 Less Than 1 100% Any cables (Item 2) in any combination 9 10 Less Than 1 1 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 23, 2006 F Rating - 3 Hr T Rating = 0 HrClassified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS-One Sealant +Bearing the UL Listing Mark *Bearing the UL Classification Marking Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 9, 2003 F Ratings - 1 & 2 Hr (See Item 4) T Ratings - 0 and 2 Hr (see Item 4) L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400 F - 4 CFM/Sq Ft Underwriters Laboratories, Inc. to UL 1479 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. December 4, 2002 F Ratings - 1 and 2 Hr (See Items 1 and 3) T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/Sq Ft L Rating At 400 F - 4 CFM/Sq Ft Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 "REPRINTED FROM THE ONLINE CERTIFICATION DIRECTORY WITH PERMISSION FROM UNDERWRITERS LABORATORIES INC." COPYRIGHT © 2004 UNDERWRITERS LABORATORIES INC.®" "REPRINTED FROM THE ONLINE CERTIFICATION DIRECTORY WITH PERMISSION FROM UNDERWRITERS LABORATORIES INC." COPYRIGHT © 2004 UNDERWRITERS LABORATORIES INC.®" "REPRINTED FROM THE ONLINE CERTIFICATION DIRECTORY WITH PERMISSION FROM UNDERWRITERS LABORATORIES INC." COPYRIGHT © 2004 UNDERWRITERS LABORATORIES INC.®" "REPRINTED FROM THE ONLINE CERTIFICATION DIRECTORY WITH PERMISSION FROM UNDERWRITERS LABORATORIES INC." COPYRIGHT © 2004 UNDERWRITERS LABORATORIES INC.®" ELEVATOR SAFETY SWITCH ELEVATOR CAB LIGHTING DISCONNECT SWITCH (30/15/1) ELEVATOR CONTROLLER PHONE OUTLET GF RECEPTACLE SMOKE DETECTOR WITHIN SPACE LIGHT SWITCH STRIP LIGHT MOUNTED IN DOOR FRAME. LITHONIA MNSL L23 1LL MVOLT 40K 80CRI M6. PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 ELECTRICAL DETAILS 04 MARCH 2022 E7.03Stanley J. Kmonk Dustin J. Ruby Garrett W. Strauss MEDVET CARMEL -ANIMAL HOSPITAL650 MAYFLOWER PARK DRIVE|CARMEL, IN 46032RENOVATION AND ADDITION07/13/22