HomeMy WebLinkAboutH2.01B - FIRST FLOOR HVAC NEW WORK - AREA Bx1 D A C B x4 x3 x5.5 26 26 27 27 28 28 25 25 xD xE xF x2 Y Y Z Z EF1 RR 106T TRIAGE 107A EXAM 1 121 XRAY 113 TRAUMA 108 BARKING ROOM 115A EX MEP 120 CAT WARD 110 CLINCAL TEAM 107B ICU 112 RR 114T JAN. 107D RR 119T ONCOLOGY SHELL SPACE 117 WARD 115 LAUNDRY 116 MEP 135 PROCEDURE ROOM 107C CORRIDOR X120 PHARMACY 109 ER/TRIAGE 107 CARDIOLOGY 118 ISOLATION 111 ANTE 111A ISOLATION 111B JC 111C ECHO 118C MECH 116A WORK RM 118A PRIVATE WK RM 118B 1 R1-22/10 675 D1-8"Ø 200 D1-10"Ø 230 D1-10"Ø 230 D1-10"Ø 230 D1-10"Ø 230 D1-10"Ø 230 R1-22/10 300 8/1214/128-1-1 TB24-1350/1350(9.0KW) 14/1416/14 R1-22/10 67514/1014/1016/1614/12 10/8 D1-8"Ø 200 R2-16/10 8-1-2 TB23-800/350(4.5KW) 1 UH1 D1-6"Ø 100 D1-8"Ø 125 R1-22/10 D1-8"Ø 150 D1-10"Ø 300 D1-6"Ø 75 R1-22/10 R1-22/10 6 7 7 10 10/1014/1012/12 8-1-3 TB23-750/240(3.0KW) R1-22/22 725 R1-22/22 725 R1-22/10 450 R1-22/10 125 R1-22/10 250 D1-10"Ø 315 D1-10"Ø 315 D1-10"Ø 315 D1-10"Ø 350 D1-6"Ø 75 D1-8"Ø 150D1-8"Ø 125 D1-8"Ø 125 D1-8"Ø 125 D1-8"Ø 225 D1-6"Ø 100 D1-6"Ø 100 D1-6"Ø 100D1-6"Ø 100 R1-22/10 125 R1-22/10 125 R1-22/10 125 R1-22/10 100 R1-22/10 225 D1-6"Ø 100D1-6"Ø 100 D1-6"Ø 100 T T T T RTU1 DHC1 DHC2 DHC3 14/10 D1-8"Ø 150 3 R1-22/22 700 16/10 R1-22/10 150 18/1216/12 22/148/68/68/818/10 22/1010/108/8 10/10 14/10 14/1418/142 R2-8/8 50 R2-8/8 50 8/8 22/1214/10 R1-22/22 700 5 6"Ø 6"Ø 6"Ø EF2 EF2 4 8/8 8/8 D1-6"Ø 75 R1-22/10 75 8/8 T TT T RTU2 R1-22/10 14/10 14/1014/1014/10 14/10 12/1216/1024/128/81/2" 8 9 1 H6.01 10/10R1-22/10 R3-16/10 600 16/8 8/88/8 8/8 8/6 8/12 8/12 16/12 UP 14/10 UP 16/10 8/8 8/8 8/8 10/8 PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: KEY PLAN 2021-0012 A BC D 20297 FIRST FLOOR HVAC NEW WORK -AREA B 04 MARCH 2022 H2.01BEric Stephens Caleb Ledford Ann Guan MEDVET INDIANAPOLIS -ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITIONN 0' 2' 4'1' SCALE: 1/4" = 1'-0"1 FLOOR PLAN FIRST FLOOR NEW WORK -AREA B CODED NOTES: 1. UP TO LEVEL 02 ABOVE. 2. UP TO RTU1 ON ROOF ABOVE. 3. UP TO RTU2 ON ROOF ABOVE. 4. UP TO RTU4 ON ROOF ABOVE. 5. 6" Ø EXHAUST DUCT UP TO ROOF ABOVE. TERMINATE WITH CURB AND ROOF CAP. 6. 10" Ø EXHAUST DUCT FOR FUTURE PHARMACY FUME HOOD. UP TO CHASE ABOVE. CAP FOR FUTURE USE. 7. 4" Ø DRYER EXHAUST. COORDINATE WITH FINAL EQUIPMENT LOCATION. TERMINATE IN SIDEWALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. CONNECT HVAC MAKE-UP WATER TO BACKFLOW PREVENTOR. COORDINATE WITH PLUMBING CONTRACTOR. 9. 4" Ø EXHAUST VENT DOWN TO DRYER. TERMINATE IN SIDEWALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. COORDINATE WITH FINAL EQUIPMENT LOCATION. 10. MAKE-UP AIR FOR COMMERCIAL DRYER EXHAUST. 07/13/22