H5.01 - HVAC SCHEDULES
LOCATION TAG UNIT DATA FAN SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON GREENHECK MOTOR DATA KEY: CENT.-CENTRIFUGAL, PROP.-PROPELLER, F.C.-FORWARD CURVED, B.I.-BACKWARD, INCLINED, A.F.-AIRFOIL. REMARKS INDICATED COMPONENTS PROVIDED BY DIV 23 DIV 26 CODED NOTES: A. DISCONNECT SWITCH B. CONTROL PANEL WITH INTEGRAL DISCONNECT SWITCH C. CONTROL PANEL D. LINE VOLTAGE PANEL E. REDUCED VOLTAGE STARTER F. TWO SPEED STARTERS G. VARIABLE FREQUENCY DRIVE H. EMERGENCY POWER J. PLUG-IN UNIT K. THERMOSTAT L. WALL SWITCH FUNCTION EF3 MODEL CFM T.S.P. IN. W.G. FAN TYPE WHEEL TYPE RPM TYPE OF DRIVE TYPE OF DAMPER TYPE OF CONTROL HP RPM VOLTS PHASE SOUND RATING IN SONES EF4 MORGUE EXHAUST CUBE-099 200 0.5 CENT. B.I. 1,253 BELT BACKDRAFT 1/4 1,800 115 1 6.5 SEE PLANSEF1 WARD/ BARKING ROOM CUBE-120 1,650 0.5 CENT. B.I. 1,603 BELT BACKDRAFT CONTINUOUS 1/2 1,800 115 1 15.7 A SEE PLANSEF2 TOILET EXHAUST SP-A90 50 0.25 CENT. B.I. - DIRECT BACKDRAFT OCCUPANCY 16.7 W 900 115 1 1 A ROOFEF5 CAT IODINE EXHAUST 350 0.5 CENT. B.I. 1,375 DIRECT BACKDRAFT CONTINUOUS 1/6 1,800 115 3 8 ACUE-095-VG EF6 STERILE EXHAUST 350 0.5 CENT. B.I. BELT BACKDRAFT CONTINUOUS 1,800 115 1 A MOUNTED ON EXTERIOR SIDEWALL INTERNAL MEDICINE CUBE-100 1,075 0.5 CENT. B.I. 1,556 BELT BACKDRAFT CONTINUOUS 1/3 1,800 115 1 10.5 A MOUNTED ON EXTERIOR SIDEWALL CONTINUOUS A SEE PLANS SEE PLANS ROOF 1,375 1/6 8CUE-095-VG SEE PLANSEF7 JANITOR EXHAUST SP-A90 50 0.25 CENT. B.I. - DIRECT BACKDRAFT CONTINUOUS 16.7 W 900 115 1 1 A UNIT ELECTRICAL DATA MOCP MCA PHASEVOLTS REMARKS HP RPM HEATING DATA WB DB WB DB L.A.T. E.A.T. EVAPORATOR DATA REF. SUPPLY FAN DATA UNLESS OTHERWISE NOTED EQUIPMENT BASED ON DAIKIN ROOFTOP AIR HANDLING UNIT SCHEDULE UNIT DATA MODEL LOCATION TAG DIV 23 INDICATED COMPONENTS PROVIDED BY DIV 26 MIN. O.A. CFM TOTAL CFM E.S.P. IN. W.G. T.S.P. IN. W.G.FILTER EFFICIENCY TOTAL MBH SENSIBLE MBH INPUT MBH OUTPUT MBH E.A.T. °F L.A.T. °F NO. OF STAGES FUEL TYPE INDICATED ELECTRICAL COMPONENTS: A. DISCONNECT SWITCH B. CONTROL PANEL WITH INTEGRAL DISCONNECT SWITCH C. CONTROL PANEL D. LINE VOLTAGE PANEL E. REDUCED VOLTAGE STARTER F. TWO SPEED STARTERS G. VARIABLE FREQUENCY DRIVE H. EMERGENCY POWER J. PLUG-IN UNIT K. THERMOSTAT L. WALL SWITCH 4.0 2,158 77.2 DPS005A SEE PLANS RTU2 315 2,100 2.0 3.0 2" MERV8 61.4 52.8 64.0 54.3 54.1 R410/A 96 NAT. GAS 55.0 97.1 13.0 15 460 3 A - MODULATING 5:1 TURN DOWN -120 RETURN/EXHAUST FAN DATA E.S.P. IN. W.G.CFM HP 1.3 2,100 RPM 2,219 0.5 *OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT* 2.3 2,089 78.0 DPS003A SEE PLANS RTU3 280 1,400 2.0 2.6 2" MERV8 37.6 33.8 64.6 55.9 55.7 R410/A 64 NAT. GAS 55.0 97.1 8.5 15 460 3 A --80 1.3 1,400 1,626 0.5 1.3 2,061 77.1 DPS003A SEE PLANS RTU4 100 720 2.0 2.2 2" MERV8 32.9 23.3 63.8 47.4 47.4 R410/A 64 NAT. GAS 55.0 135.9 7.6 15 460 3 A --80 0.5 DPS003A SEE PLANS RTU5 180 1,200 2.0 2" MERV8 R410/A NAT. GAS 55.0 8.5 15 460 3 A --1.3 1,200 1,473 0.5 2.3 1,996 77.2 DPS003A SEE PLANS RTU6 180 1,200 2.0 2.5 2" MERV8 36.4 30.8 64.0 53.8 53.7 R410/A 64 NAT. GAS 55.0 104.2 8.5 15 460 3 A --80 1.3 1,200 0.5 2.3 1,612 76.2 DPS003A SEE PLANS RTU7 100 1,200 1.0 1.5 2" MERV8 35.8 30.6 63.1 52.9 52.8 R410/A 64 NAT. GAS 55.0 104.9 8.5 15 460 3 A --80 1.3 0.5 4 @ 7.3 1,645 80.9 DPSA040 SEE PLANS RTU8 5,500 14,000 3.0 4.8 2" MERV8 518.9 394.9 67.0 55.1 55.1 R410/A 648 NAT. GAS 50.0 93.0 117.5 125 460 3 A --800 2 @ 3.0 8,500 1,688 1.5 SEE PLANS RTU9 1,200 4,200 2.0 2" MERV8 R410/A NAT. GAS 50.0 460 3 A - 4" MERV14 0.5 MODULATING 5:1 TURN DOWN MODULATING 5:1 TURN DOWN MODULATING 5:1 TURN DOWN MODULATING 5:1 TURN DOWN MODULATING 5:1 TURN DOWN MODULATING 10:1 TURN DOWN 2.5 2.3 1,996 77.2 36.4 30.8 64.0 53.8 53.7 64 104.2 80 1,473 1,200 1,473 SERVES NEW BUILDING ADDITION SERVES OPERATING ROOMS 1.3 720 1,160 SERVES EXISTING BUILDING RENOVATION SERVES EXISTING BUILDING RENOVATION SERVES EXISTING BUILDING RENOVATION SERVES EXISTING BUILDING RENOVATION SERVES EXISTING BUILDING RENOVATION SERVES EXISTING BUILDING RENOVATION DPSA018A 2.7 5.0 1,754 181.3 126.6 75.0 63.0 47.4 47.4 4.0 4,200 1,442 44.4 60 240 102.7 300 MODULATING 12:1 TURN DOWN TO BE PRICED AS AN ALTERNATE TO BE PRICED AS AN ALTERNATE UNIT ELECTRICAL DATA MOCP MCA PHASEVOLTS REMARKS HP RPM HEATING DATA WB DB WB DB L.A.T.E.A.T. EVAPORATOR DATA REF. SUPPLY FAN DATA UNLESS OTHERWISE NOTED EQUIPMENT BASED ON DAIKIN MAKEUP ROOFTOP UNIT SCHEDULE UNIT DATA MODELLOCATIONTAG DIV 23 INDICATED COMPONENTS PROVIDED BY DIV 26 TOTAL CFM E.S.P. IN. W.G. T.S.P. IN. W.G. FILTER EFFICIENCY TOTAL MBH SENSIBLE MBH INPUT MBH OUTPUT MBH E.A.T. °F L.A.T. °F NO. OF STAGES FUEL TYPE INDICATED ELECTRICAL COMPONENTS: A. DISCONNECT SWITCH B. CONTROL PANEL WITH INTEGRAL DISCONNECT SWITCH C. CONTROL PANEL D. LINE VOLTAGE PANEL E. REDUCED VOLTAGE STARTER F. TWO SPEED STARTERS G. VARIABLE FREQUENCY DRIVE H. EMERGENCY POWER J. PLUG-IN UNIT K. THERMOSTAT L. WALL SWITCH 2.3 2,182 78.8 DPS007A SEE PLANSRTU1 1,825 2.00 2.6 89.3 55.6 67.2 50.9 50.9 R410/A 160 NAT. GAS 50.0 131.1 17.0 20 460 3 A - MODULATING 10:1 TURN DOWN EXHAUST FAN DATA E.S.P. IN. W.G.CFM HP 2.3 2,275 RPM 1,860 *OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT* 2" MERV8 200 0.5 HEAT RECOVERY SCHEDULE TAG WINTER IN °F WINTER OUT °F SUMMER IN °F SUMMER OUT °F A.P.D. IN. W.G. RTU1 -10.0 1,825 CFM 0.32 53.5 1,825 CFM 90.0/74.0 1,825 CFM 78.8/67.2 1,825 CFM HUMIDIFIER SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON NEPTRONIC REMARKS STEAM PSIG CAPACITY LBS/HR DUCT/UNIT SIZE AIR FLOW (CFM) DB TEMP. / RH °F / % E.A. L.A. SETPOINT %RH ABSORPTION DISTANCE (INCHES) ELECTRICAL DATA VOLTS AMPS PHASE TAG LOCATION MODEL H1 - 55/22 55/35 12.0 480 3 SEE PLAN 4,200 30/14 30.0 25 6"PROVIDE WITH INTERNAL DRAIN COOLER.SKE4-N10M CODED NOTES: A. DISCONNECT SWITCH B. CONTROL PANEL WITH INTEGRAL DISCONNECT SWITCH C. CONTROL PANEL D. LINE VOLTAGE PANEL E. REDUCED VOLTAGE STARTERTWO SPEED STARTERS F. VARIABLE FREQUENCY DRIVE G. EMERGENCY POWER LOCATION TAG AIR DATA ELECTRIC DUCT HEATING COIL SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON INDEECO *OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT* REMARKS UNIT DATA DIV 23 INDICATED COMPONENTS PROVIDED BY H. PLUG-IN UNIT I. THERMOSTAT J. WALL SWITCH DHC1 MODEL CFM 350 SEE PLANS QUA E.A.T. °F 53 L.A.T. °F 84.6 ELECTRICAL DATA KW 10/8 VOLTS 277 PHASE 1 FACE VELOCITY FPM DIV 26 615 I, A - RTU1 SUPPLY DUCTWORK SCR HEATING SERVES LARGE ISOLATION ROOM DUCT SIZE 2.5 DHC2 75 SEE PLANS QUA 53 74.1 8/8 277 1 160 I, A - RTU1 SUPPLY DUCTWORK SCR HEATING SERVES SMALL ISOLATION ISOLATION ROOM 0.5 DHC3 150 SEE PLANS QUA 53 74.1 8/8 277 1 555 I, A - RTU1 SUPPLY DUCTWORK SCR HEATING SERVES SMALL ISOLATION ISOLATION ROOM 1.0 MODEL LOCATION TAG REGISTER & DIFFUSER SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON PRICE FUNCTION REMARKS NECK SIZES ARE GIVEN ON DRAWINGS. FACE TYPE FRAME TYPE LOUVER TYPE MATERIAL FINISH DAMPER N.C. MAX SPD D1 SUPPLY SQUARE PLAQUE -STEEL WHITE NONE 30 FACE SIZE 24"X24" UNLESS NOTED OTHERWISE. PROVIDE TRIM FRAME FOR DRYWALL CEILING LOCATIONS.LAY-INSEE PLANS LFD D2 SUPPLY LAMINAR FLOW -ALUMINIUM WHITE NONE 30 FACE SIZE 48"X24" UNLESS NOTED OTHERWISE. LAY-IN 80R1 RETURN/ EXHAUST ½"X½"X½" GRID EGGCRATE ALUMINIUM WHITE NONE 30LAY-IN PROVIDE TRIM FRAME FOR DRYWALL CEILING LOCATIONS. SEE PLANS SEE PLANS 600R2 LOUVERED FIXED BLADE ALUMINIUM WHITE NONE 30SURFACESEE PLANS FACE SIZE NOTED ON PLANS. 600 R3 LOUVERED ADJ. BLADE ALUMINIUM WHITE NONE 30SURFACE SEE PLANS FACE SIZE NOTED ON PLANS. RETURN/ EXHAUST SUPPLY SPLIT AIR CONDITIONING UNIT SCHEDULE UNLESS OTHERWISE NOTED EQUIPMENT BASED ON DAIKIN *OWNER FURNISHED, CONTRACTOR INSTALLED EQUIPMENT* TAG LOCATION MODEL ARRANGEMENT CFM TOTAL MBH REF.CAPACITY MBH AMBIENT OPERATION °F TAG REMARKS AC1 SEE PLANS 555 24 R-410A N/A ACCU1 PROVIDE CONDENSATE PUMP, E.C. TO PROVIDE DISCONNECT MOCP 20 MCA VOLTS PHASE MODEL RKB24AXVJU UNIT DATA COOLING CONDENSING UNIT DATAHEATING FTKB24AXVJU WALL MOUNTED 13.2 208 1 -10 PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 HVAC SCHEDULES 04 MARCH 2022 H5.01Eric Stephens Caleb Ledford Ann Guan MEDVET INDIANAPOLIS -ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION07/13/22