T0.00 - TECHNOLOGY SYMBOLS AND LEGENDS
WALL PHONE, (1) CAT6 UTP FOR VOICE 46"W TECHNOLOGY SYSTEMS ABBREVIATIONS TECHNOLOGY GENERAL NOTESTECHNOLOGY SYMBOLS TECHNOLOGY SYMBOLS SYMBOL LIST GENERAL INFORMATION SCOPE OF WORK NOTES 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. WHEREVER THE WORD PROVIDE IS USED IT SHALL MEAN TO "FURNISH AND INSTALL". 3. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE OWNER RESERVES THE RIGHT TO APPROVE METHODS AND MATERIALS NOT REFLECTED HERE IN. 4. CONTRACTOR SHALL VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 5. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE OWNER. 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES, ORDINANCES AND STANDARDS. 7. PROVIDE RECORD DRAWINGS. INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, REROUTINGS, ETC. 8. VERIFY EXACT LOCATION OF EQUIPMENT PRIOR TO ROUGH-IN. 9. ALL CABLING THAT PASSES THROUGH OR ORIGINATES IN EXPOSED CEILING SPACES SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS. RACEWAYS IN SLAB-ON-GRADE OR BELOW GRADE SHALL BE SCHEDULE 40 PVC. TRANSITIONS FROM BELOW TO ABOVE GRADE SHALL BE WITH RIGID STEEL ELBOWS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. 10. THERE SHALL BE NO MORE THAN TWO 90 DEGREE BENDS BETWEEN PULL BOXES. PULL BOXES AND CABLE TRAYS SHOWN ON DRAWINGS SHALL BE CONSIDERED THE MINIMUM REQUIREMENTS. CONTRACTOR SHALL INSTALL PULL BOXES ACCORDING TO FIELD CONDITIONS. 11. ALL CABLING ABOVE ACCESSIBLE CEILING AREAS, WHERE NOT IN CABLE TRAY, SHALL BE SUPPORTED WITH A J-HOOK SUPPORT SYSTEM. J-HOOK SPACING SHALL VARY BETWEEN 4' AND 5' ON CENTER. J-HOOK SHALL NOT BE SUPPORTED BY OR OTHERWISE ATTACHED TO THE SUSPENDED CEILING GRID WIRES OR ANY OTHER BUILDING ANCILLARY SYSTEM SUCH AS ELECTRICAL OR PLUMBING CONDUITS. 12. REFER TO ARCHITECTURAL PLANS FOR WALL CONSTRUCTION. 13. RACEWAYS SHALL BE RUN AS INCONSPICUOUSLY AS POSSIBLE. VERTICAL RUNS SHALL OCCUR IN CORNERS OF ROOMS. HORIZONTAL RUNS SHALL OCCUR ALONG BASEBOARD OF WALL WITH VERTICAL RUNS UP TO THE DEVICE BOXES BRANCHING OUT OF CORNER BOXES, TEES OR ELBOWS. 14. ALL CONDUITS IN AREAS WITHOUT SUSPENDED CEILINGS SHALL BE RUN AS INCONSPICUOUSLY AS POSSIBLE, HIDDEN BEHIND BEAMS, CLOSE TO DECK, ETC. OBTAIN APPROVAL OF CONDUIT RUNS BELOW BEAMS WITH OWNER'S REPRESENTATIVE. 15. ADD STEEL BRIDGING BETWEEN PURLINS/JOISTS/BEAMS AS NECESSARY TO SUPPORT THE WEIGHT OF SUSPENDED DEVICES AND FIXTURES. 16. ALL DEVICES IN CEILINGS IN A ROOM SHALL BE ALIGNED. 17. AT EXISTING LOCATION WHERE WALL FURRING DEPTH IS TOO SHALLOW FOR A STANDARD DEPTH JUNCTION BOX, CONTRACTOR SHALL CHISEL OUT SURROUNDING MATERIAL SO THAT BOX IS FLUSH WITH WALL. WHERE CONDUIT IS TOO DEEP, CONTRACTOR SHALL CHANNEL OUT SURROUNDING MATERIAL. EXPOSED SURFACE MOUNTED CONDUIT AND JUNCTION BOXES ARE PROHIBITED. 18. PROVIDE SURFACE RACEWAY SIZE ADEQUATE FOR QUANTITY OF DATA CABLES. 19. COORDINATE WITH OWNER FOR EXACT MOUNTING HEIGHT AND LOCATION OF ALL WALL-MOUNTED SECURITY CAMERAS. 20. FOR ALL EXTERIOR NETWORK DEVICES CONNECTED WITH CATEGORY CABLING, TERMINATE NETWORK CABLE AT BISCUIT JACK JUST INSIDE BUILDING AND PROVIDE LIGHTNING PROTECTION AT THIS POINT. EXTEND CONDUIT AND PATCH CABLE FROM THIS POINT TO DEVICE LOCATION. 21. REFER TO SITE PLANS FOR SITE REQUIREMENTS. 22. PROVIDE ONE 2 INCH SLEEVE INTO EACH ROOM FROM THE CORRIDOR WHERE WALLS GO UP TO THE FLOOR OR ROOF DECK ABOVE, UNLESS OTHERWISE NOTED. SLEEVE ELEVATION SHALL BE ABOVE HEIGHT OF SUSPENDED CEILING, AS CLOSE TO FLOOR OR ROOF DECK AS POSSIBLE. 1. ALL CATEGORY CABLING AS SPECIFIED IN DIVISION 27 AND/OR DIVISION 28, INCLUDING BUT NOT LIMITED TO CABLING FOR NURSE CALL, CCTV, ACCESS CONTROL, AV-OVER-IP, CONTROL, NETWORK, AND HDBASET, SHALL BE PROVIDED BY DIVISION 27 STRUCTURED CABLING CONTRACTOR. ALL CATEGORY CABLING FOR DIVISION 27 AND DIVISION 28 APPLICATIONS SHALL COMPLY WITH INSTALLATION, TESTING, AND CERTIFICATION REQUIREMENTS PER SPECIFICATION SECTION 27 10 00. EQUIPMENT ROOMER BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONAL BUILDING MANAGEMENT SYSTEM COMMUNITY ANTENNA TELEVISION (CABLE TELEVISION) COMMUNICATIONS RISER CABLE COAXIAL CABLE CUSTOMER PREMISES EQUIPMENT CONSTRUCTION SPECIFICATIONS INSTITUTE DECIBEL AMERICAN WIRE GAUGE BUILDING AUTOMATION SYSTEM BONDING CONDUCTOR FOR TELECOMMUNICATIONS COMPUTER-AIDED DESIGN CLOSED-CIRCUIT TELEVISION COMMUNICATIONS GENERAL-PURPOSE CABLE COMMUNICATIONS PLENUM CABLE DISTRIBUTED ANTENNA SYSTEM DECIBEL MILLIVOLT CAD DAS dB EF dBmV ENTRANCE FACILITY CPE CSI CM CMR CMP COAX CATV CCTV BMS BAS BCT BICSI ANSI AWG AMERICAN NATIONAL STANDARDS INSTITUTE GENERAL CONTRACTOR HORIZONTAL CROSS-CONNECT GC HC RF RADIO FREQUENCY RADIO FREQUENCY IDENTIFICATION RED, GREEN, BLUE RFID RGB RACK UNIT STRUCTURED CABLING SYSTEM RU SCS TBB TELECOMMUNICATIONS BONDING BACKBONE TELECOMMUNICATIONS CLOSET TELECOMMUNICATIONS DEVICE FOR THE DEAF TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL TC TDD TDMM SCREENED TWISTED-PAIR SINGLEMODE SMALL FORM FACTOR SHIELDED TWISTED-PAIR SFF SM STP ScTP TELECOMMUNICATIONS GROUNDING BUSBAR TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TGB TMGB TELECOMMUNICATIONS ROOMTR TELEVISIONTV WAN WIDE AREA NETWORK WIRELESS ACCESS POINT WIRELESS LOCAL AREA NETWORK WAP WLAN UNDERWRITERS LABORATORIES INC. UNIVERSAL SERVICE ORDER CODE UNINTERRUPTIBLE POWER SUPPLY UNSHIELDED TWISTED-PAIR UPS USOC VoIP UTP VOICE OVER INTERNET PROTOCOL UL OD OUTSIDE DIAMETER ORIGINAL EQUIPMENT MANUFACTURER OPTICAL FIBER CONDUCTIVE RISER CABLE OPTICAL FIBER NONCONDUCTIVE PLENUM CABLE OEM OFCR OFNP HEATING, VENTILATING, AND AIR CONDITIONING INTERMEDIATE CROSS-CONNECT ISOLATED GROUND INPUT/OUTPUT (DEVICE) KEYBOARD / VIDEO / MOUSE MAIN CROSS-CONNECT MAIN DISTRIBUTION FRAME MULTIMODE MULTI-USER TELECOMMUNICATIONS OUTLET ASSEMBLY INSIDE DIAMETER INSULATION DISPLACEMENT CONNECTOR INTERNET PROTOCOL INFORMATION TECHNOLOGY LOCAL AREA NETWORK MAIN DISTRIBUTOR MAINTENANCE HOLE NATIONAL ELECTRICAL CODE IP MD MUTOA NIC NEC NOT IN CONTRACT MDF MH MM MC IT KVM LAN I/O IDC IG HH HVAC IC ID HANDHOLE OPTICAL FIBER NONCONDUCTIVE RISER CABLE OUTSIDE PLANT OPTICAL TIME DOMAIN REFLECTOMETER OFNR OSP OTDR PoE POWER OVER ETHERNET PAIR PUBLIC SWITCHED TELEPHONE NETWORK PAN,TILT, AND ZOOM PR PSTN PTZ PUBLIC ADDRESS PRIVATE BRANCH EXCHANGEPBPBX PA POLYVINYL CHLORIDE QUALITY OF SERVICE REGISTERED COMMUNICATIONS DISTRIBUTION DESIGNER PVC QoS RCDD NOT APPLICABLEN/A AUTHORITY HAVING JURISDICTIONAHJ ANGLE POLISHED CONNECTORAPC AUDIO VISUALAV BONDING CONDUCTORBC CATEGORYCAT CONSOLIDATION POINTCP COMPUTER ROOM AIR CONDITIONINGCRAC DIGITAL VIDEO RECORDERDVR GROUNDING EQUALIZER CONDUCTORGEC GROUNDING EQUALIZERGE PASSIVE OPTICAL NETWORKPON HIGH-DEFINITION MULTIMEDIA INTERFACEHDMI INFORMATION TECHNOLOGY SYSTEMSITS LIQUID CRYSTAL DISPLAYLCD LIGHT-EMITTING DIODELED NETWORK VIDEO RECORDERNVR OPTICAL LINE TERMINALOLT OPTICAL NETWORK TERMINALONT POINT OF SALEPOS REQUEST TO EXITREX SCREENED / FOIL TWISTED-PAIRS/FTP FOIL TWISTED-PAIRFTP TELECOMMUNICATIONS ENCLOSURETE TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTORTEBC TELECOMMUNICATIONS OUTLETTO TRANSMITTERTX RECEIVERRX UNSHIELDED TWISTED-PAIR WITH FOIL SCREENED TWISTED-PAIRU/FTP UNSHIELDED TWISTED-PAIR WITH UNSHIELDED TWISTED-PAIRU/UTP CONDUCTORS CONDUCTORS VLAN VIRTUAL LAN VPN VIRTUAL PRIVATE NETWORK WAO WORK AREA OUTLET UNLESS NOTED OTHERWISEUNO ABOVE ACCESSIBLE CEILINGAAC ABOVE FINISH GRADEAFG ABOVE FINISH FLOORAFF BELOW FINISH GRADEBFG INDICATES MOUNTING HEIGHT (N) TO CENTER OF DEVICE AFF+N NOT TO SCALENTS INFORMATION SYSTEMSIS OWNER-FURNISHED EQUIPMENTOFE AUDIO/VISUAL SYMBOLS MOUNTING HEIGHTS ARE TO CENTER U.N.O. SOME SYMBOLS MAY NOT BE USED. SYMBOL 2. 1. DESCRIPTION NOTED OTHERWISE HEIGHT UNLESS MOUNTING SECURITY SYSTEM HORN; WP - WEATHERPROOF SECURITY SYSTEM ELECTRIC DOOR LATCH SECURITY SYSTEM DOOR POSITION SWITCH SECURITY SYSTEM MAGNETIC DOOR LATCH ; CR E M P IC MD K M ; IC SECURITY SYSTEM CARD READER, SECURITY SYSTEM KEY PAD SECURITY SYSTEM MOTION DETECTOR INTERCOM; MASTER, DOOR STATION WP D ---- ---- 46" ---- ---- 46" CEIL. OR 94" 46" 1 PORT, WALL MOUNT, (1) CAT6 UTP 18" 2 PORT, WALL MOUNT, (2) CAT6 UTP2 18" 3 PORT, WALL MOUNT, (3) CAT6 UTP3 18" 4 PORT, WALL MOUNT, (4) CAT6 UTP4 18" ELEVATOR, (1) CAT6 UTP, ANALOG LINEE ---- AP WIRELESS ACCESS POINT, (2) CAT6A UTP IN CEILING SECURITY SYMBOLS VOICE/DATA SYMBOLS COORD. HTFR DATA OUTLET FOR FREEZER / FRIDGE, (1) CAT6 UTP MD M COORD. HTDATA OUTLET FOR MULTIFUNCTION DEVICE, (2) CAT6 UTP CONDUIT, RISER UP CONDUIT, RISER DOWN ---- ---- AV DATA OUTLET FOR MONITOR, (1) CAT6 UTP 60" MICROPHONE INPUT JACK, WALL MOUNTED; FLOOR MOUNTED;; F 18" INTERIOR SECURITY SYSTEM CAMERA, (1) CAT6 UTP 92" GB SECURITY SYSTEM GLASS BREAK DETECTION CEIL. OR 94" BUZZER 92" TV TELEVISION OUTLET, (1) CAT6 UTP, (1) RG6 COAX 60" SOUND SYSTEM SPEAKER, PENDANT MOUNTED ----SP * SOUND SYSTEM SPEAKER, CEILING MOUNTED; WALL MOUNTED;94"S S * * * = ZONE NUMBER V SOUND SYSTEM VOLUME ATTENUATOR 46" SOUND SYSTEM OUTDOOR HORN SPEAKERS P VIDEO PROJECTOR, CEILING MOUNTED, (1) CAT6 UTP IN CEILING MONITOR VIDEO MONITOR DISPLAY DEVICE;---- EMERGENCY CALL/STROBE LIGHTEC DURESS ALARMDA ---- POKE-THRU FOR POWER / COMMUNICATIONS CONNECTION ---- TO DEVICES AT FURNITURE FLOOR BOX FOR POWER / COMMUNICATIONS CONNECTION TO DEVICES AT FURNITURE ---- CEILING MOUNTED; WALL MOUNTED; "PTZ" = PAN, TILT, ZOOM, EXTERIOR SECURITY SYSTEM CAMERA, (1) CAT6 UTP 144" DUAL SERVICE FIELD WIRED MULTIPLE OUTLET RACEWAY SEE DRAWINGS ---- AUDIO/VISUAL OUTLET. PROVIDE 4-11/16" DEEP BOX W/ DOUBLE GANG RING AND (2) 1-1/4" CONDUITS STUBBED TO ABOVE ACCESSIBLE CEILING FOR LAY-IN CEILING APPLICATIONS (CONDUITS EXTENDED TO PROJECTOR FOR EXPOSED CEILING APPLICATIONS). SEE DRAWINGS CP CONTROL PANEL, (1) CAT6 UTP ---- TS TOUCHSCREEN CONTROLLER, (1) CAT6 UTP ---- MOUNTING HEIGHTS ARE TO CENTER U.N.O. SOME SYMBOLS MAY NOT BE USED. 2. 1. SYMBOL DESCRIPTION NOTED OTHERWISE HEIGHT UNLESS MOUNTING MISCELLANEOUS SYMBOLS 104"8' H X 4' W X 3/4" A/C QUALITY OR BETTER PLYWOOD BACKBOARD IN TR SPACES, MOUNT 8" AFF 4' WIDE BY 8' TALL AT SPECIFIED LOCATIONS, PAINT FRONT BACK AND SIDES WITH TWO COATS FIRE RETARDANT PAINT. EZ PATH SERIES 44+ MULTIGANG FIRESTOP. QUANTITY OF ABOVE CEILINGEZ GANGS AS REQUIRED TO ALLOW 30% SPARE CAPACITY. AR S AREA OF RESCUE STATION 48" TO CENTER AR CC AREA OF RESCUE COMMAND CENTER 60" TO CENTER ; P = PATIENT ROOM TELEVISION OUTLET, (1) CAT6 UTP, (1) RG6 COAX, (1) HDMI, (1) 1/4", 3-CONDUCTOR CABLE CF = CONFERENCE ROOM TELEVISION OUTLET, (1) CAT6 UTP, (1) RG6 COAX, (1) HDMI, (1) VGA, (1) 3.5 mm 60" 60" H = HIGH OUTLET L = LOW OUTLET WP = WEATHERPROOF V = INTEGRAL VOLUME CONTROL * = ZONE NUMBER V = INTEGRAL VOLUME CONTROL W = WALL MOUNTED COORD. HT * = SCREEN DIAGONAL W = WALL MOUNTED B * CS LS CS CS LS IN CEILING CENTRAL SOUND SYSTEM WALL MOUNTED SPEAKER 144" CENTRAL SOUND SYSTEM WALL MOUNTED PAGING HORN 144" LOCAL SOUND SYSTEM CEILING MOUNTED SPEAKER IN CEILING LOCAL SOUND SYSTEM WALL MOUNTED SPEAKER 144" CENTRAL SOUND SYSTEM CEILING MOUNTED SPEAKER CS CENTRAL SOUND SYSTEM CEILING MOUNTED PAGING HORN IN CEILING SBB (SECONDARY BONDING BUSBAR) PBB (PRIMARY BONDING BUSBAR) 90" 90" LOCAL DOOR ACCESS CONTROLLER, (1) CAT6 UTPDC ---- PUSH BUTTON DOOR RELEASE ---- AR L AREA OF RESCUE LIGHTED SIGN MATCH ADJACENT EXIT SIGN 2W TWO-WAY EMERGENCY COMMUNICATIONS SYSTEM;48"; 2W SM CEILING MOUNTED ;C INCLUDES DOOR POSITION SWITCH(ES) P DATA OUTLET FOR PRINTER, (1) CAT6 UTP ---- MASTER, SLAVE STATION, (1) CAT6 UTP BLUE LIGHT EMERGENCY PHONEBL 46" FLOOR RECESSED OUTLET BOX* ----* = # OF CAT6 PORTS (AND CABLES) FLOOR RECESSED / FIRE RATED "POKE THRU" OUTLET ASSEMBLY* ----* = # OF CAT6 PORTS (AND CABLES) (1) FOR DATA AND (1) FOR VOICE TC STAFF TIME CLOCK, (1) CAT6 UTP SEE DRAWINGS CLINICAL ENGINEERING, WALL MOUNT COORD. HT COORD. HT * = # OF CAT6 PORTS (AND CABLES) * DEVICE SUFFIXES F C M AC WP WG FLOOR MOUNTED OUTLET CEILING MOUNTED OUTLET MODULAR FURNITURE OUTLET ABOVE COUNTER OUTLET WEATHER PROOF WIRE GUARD W WALL MOUNTED 1. DASHED SYMBOLS INDICATE EXISTING DEVICES TO BE REMOVED. 2. SOLID SYMBOLS WITH SUBSCRIPT "R" INDICATE EXISTING DEVICES TO REMAIN. 3. DASHED SYMBOLS WITH SUBSCRIPT "REL" INDICATE EXISTING DEVICES TO BE RELOCATED. 4. SOLID SYMBOLS WITH SUBSCRIPT "RD" INDICATE RELOCATED DEVICES. S = EZ PATH SERIES 33NEZ MULTIGANG SMOKE & ACOUSTICAL PATHWAY. QUANTITY OF GANGS AS REQUIRED TO ALLOW 30% SPARE CAPACITY. * S SURFACE RACEWAY OUTLET MAXIMUM CABLE CONDUIT FILL TABLE TECHNOLOGY CABLE TYPE NOMINAL CABLE O.D. CONDUIT SIZE 0.75" 1" 1.25" 1.5" 2" 2.5" 3" 3.5" 4" CAT6A PLENUM 0.309" 1 3 4 6 12 19 27 38 50 CAT6A NON-PLENUM 0.309" 1 3 4 6 12 19 27 38 50 CAT6 PLENUM 0.237" 3 5 8 12 21 33 48 65 85 CAT6 NON-PLENUM 0.234" 3 5 8 12 21 33 48 66 87 CAT6 OSP 0.251" 2 4 6 10 18 28 41 56 73 RG6 PLENUM 0.233" 3 5 8 12 21 33 48 66 87 RG11 PLENUM 0.348" N/A 1 3 4 7 12 17 24 31 1. FOR ALL VOICE/DATA APPLICATIONS, EXCEPT FOR INDIVIDUAL SECURITY DEVICES, 1" MINIMUM CONDUIT IS REQUIRED. 2. CONDUIT FILL CALCULATIONS ARE BASED ON 25% SPARE FUTURE CAPACITY. 3. FOR MIXED CABLE TYPES IN THE SAME CONDUIT, PERFORM CONDUIT FILL CALCULATIONS FOR MAXIMUM CROSS-SECTIONAL AREA OF 30%. 4. VERIFY ALL CABLE TYPES ARE OF SIMILAR O.D. AS BASIS OF DESIGN. PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY: © 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 20297 TECHNOLOGY SYMBOLS AND LEGENDS 04 MARCH 2022 T0.00Stanley J. Kmonk Dustin J. Ruby Garrett W. Strauss MEDVET CARMEL -ANIMAL HOSPITAL650 MAYFLOWER PARK DRIVE|CARMEL, IN 46032RENOVATION AND ADDITIONTECHNOLOGY SHEET INDEX SHEET NUMBER SHEET NAME T0.00 TECHNOLOGY SYMBOLS AND LEGENDS T2.01A FIRST FLOOR - TECHNOLOGY PLAN - AREA A T2.01B FIRST FLOOR - TECHNOLOGY PLAN - AREA B T2.01C FIRST FLOOR - TECHNOLOGY PLAN - AREA C T2.01D FIRST FLOOR - TECHNOLOGY PLAN - AREA D T2.02A SECOND FLOOR - TECHNOLOGY PLAN - AREA A T2.02B SECOND FLOOR - TECHNOLOGY PLAN - AREA B T2.02C SECOND FLOOR - TECHNOLOGY PLAN - AREA C T2.02D SECOND FLOOR - TECHNOLOGY PLAN - AREA D T2.02E SECOND FLOOR - TECHNOLOGY PLAN - AREA E T4.01 TECHNOLOGY DETAILS 07/13/22