A0.02 INTERIOR PARTITION SCHEDULE
RATED STUD WALL PENETRATION TEST DESIGNATION SCHEDULE RATED MASONRY WALL PENETRATION TEST DESIGNATION SCHEDULE PENETRATION TYPE SCHEDULE DETAIL "A" CONTINUE GYP. BD BEHIND STUD -PROVIDE PROPER PENETRATION PROTECTION AT PENETRATIONS OF WIRE, CONDUIT, ETC AT THIS AREA. PACK STUD CAVITY W/ FIRE SAFING @ LOWER CEILING LINE. ALT: RUN GYP BD TO TOP TRACK IN LIEU OF FIRE SAFING SEAL ALL PENETRATIONS IN TOP TRACK W/ FIRE SEALANT SEAL ALL PENETRATIONS IN TOP TRACK W/ FIRE SEALANT NON-RATED PARTITION 4" ABOVE CEILING W/ CEILINGS OF VARYING HEIGHT (NON-COMBUSTIBLE WALL) PARTITION FRAMING @ DOOR OPENING MTL DECK PROVIDE MIN 1/2" UNDERCUT @ MTL STUDS ANCHOR GYP BD TO STUDS NO CLOSER THAN 6" TO TRACK GYP BD EA SIDE NON RATED PARTITION TO UNDERSIDE OF DECK ANCHOR GYP BD TO STUDS NO CLOSER THAN 6" TO TRACK PROVIDE 1/2" UNDERCUT @ MTL STUDS MTL DECK DEEP LEG TRACK ATTACH TO UNDERSIDE OF DECK/STRUCTURE DO NOT ANCHOR STUDS TO TRACK MTL STUDS CONT. BRIDGING 1/2" MIN TOP EDGE OF GYP BD 1/2"MINGYP BD EA SIDE 6"ELECTRICAL OUTLET BOXES @ FIRE SEPARATION WALLS, & FIREWALLS 24" MIN BETWEEN BOXES RATED PARTITION TO UNDERSIDE OF DECKRATED / NON-RATED WALL INTERSECTIONS RATED WALL ASSEMBLY (2 HR SHOWN) CONTINUE GYP. BD BEHIND STUD -PROVIDE PROPER PENETRATION PROTECTION AT PENETRATIONS OF WIRE, CONDUIT, ETC AT THIS AREA. CEILING NON RATED WALL ASSEMBLY NON RATED WALL ASSEMBLY 1/2" MIN DEEP LEG TRACK ATTACH TO UNDERSIDE OF DECK/STRUCTURE DO NOT ANCHOR STUDS TO TRACK CONT. BRIDGING MTL STUDS TOP EDGE OF GYP BD FIRE SEALANT PACK DECK FLUTES TIGHT W/ FIRE SAFING 1/2"NON-RATED PARTITION 4" ABOVE CEILING MTL STUD BRACES TO STRUCT. ABOVE @ 48" O.C. ALTERNATE DIRECTION CEILING 45° MTL STUD BRACES TO STRUCT. ABOVE @ 48" O.C. ALTERNATE DIRECTION 45°4"45°MIN4"45° FLOOR LINE PROVIDE 1/2" GAP STUD TO TRACK PROVIDE ELONGATED SLOT FOR DEFLECTION SCREW TO STUD @ BTM OF SLOT 20 GA DEEP LEG TRACK MIN 6" LONG W/ 2 -#10 3/4" SELF TAPPING SCREWS TO STUD -ANCHOR TRACK TO STRUCTURE SEE DETAIL "A" 20 GA RUNNER DOOR OPENING MAX 6" SECURE RUNNER TRACK TO 20 GA STUDS W/ 20 GA CLIPS #(4) SELF TAPPING SCREWS MAX (2) 20GA STUDS FLOOR TO UNDERSIDE OF SLAB 6" STRUCTURE LINE DOOR FRAME PROVIDE 1/2" GAP EA SIDE BETWEEN JACK STUDS & FULL HEIGHT STUDS FOR CJ 5 6 3 1 4 2 TYPE OF SINGLE ITEM PENETRATION 1 HR ASSEMBLY "F" RATING 1 HR 2 HR ASSEMBLY "F" RATING 2 HR METALLIC CONDUIT 4"Ø OR SMALLER EMT CONDUIT 6"Ø OR SMALLER STEEL CONDUIT WL1091 WL1091 WL1091 WL1091 NON-METALLIC CONDUIT 2"Ø OR SMALLER SCH 40 PVC WL2038 WL2038 METALLIC PIPE/COPPER PIPE/TUBE 6"Ø OR SMALLER TYPE L OR HEAVIER TUBING 6"Ø OR SMALLER REGULAR OR HEAVIER PIPE WL1091 WL1091 WL1091 WL1091 NON-METALLIC PIPE/TUBE 2"Ø OR SMALLER SCH 40 PVC/CPVC 4"Ø OR SMALLER SCH 40 PVC/CPVC WL2003 WL2014 WL2003 WL2014 CABLE/WIRE W/ NON-COMB JACKETS/INSUL MAX 4 COPPER CONDUCTOR NO 2 AWG OR SMALLER ALUM OR STELL ARMORED/MTL CLAD CABLE WL3015 WL3015 NON-COMBUSTIBLE PIPES/TUBES/VENTS 6"Ø (MAX) TYPE L (OR HEAVIER) COPPER TUBE 6"Ø (MAX) REGULAR (OR HEAVIER) COPPER PIPE 24"Ø (MAX) SCH 10 (OR HEAVIER) STEEL PIPE 24"Ø (MAX) CAST OR DUCTILE IRON PIPE WL1091 WL1091 WL1091 WL1091 WL1091 WL1091 WL1091 WL1091 CABLE/WIRE W/ COMB JACKETS/INSUL MAX NO 10 AWG COPPER MULTI CONDUCTOR (NM) CABLE W/ PVC INSUL MAX 150 PAIR NO 24 AWG COPPER TELEPHONE CABLE W/ PVC INSUL WL3001 WL3001 WL3001 WL3001 COMBUSTIBLE PIPES/TUBES/VENTS 2"Ø (MAX) SCH 40 PVC/CPVC (DWV) PIPING 4"Ø (MAX) SCH 40 PVC/ABS/FRPP 8" OR 10"Ø SCH 40 PVC (DWV) PIPING WL2003 WL2005 WL2003 WL2005 NOTES: 1. TESTS NOTED ARE FOR SINGLE ITEM PENETRATIONS. ALL TEST DESIGNATIONS ARE UNDERWRITERS LABORATORIES (UL) UNLESS NOTED OTHERWISE. 2. FOR PENETRATIONS OTHER THAN THOSE LISTED REFER TO DWG LOCATION OF PENETRATION OR CURRENT UNDERWRITERS LABORATORY FIRE RESISTANCE DIRECTORY FOR PENETRATION TEST. ALL TEST DESIGNATIONS ARE UNDERWRITERS LABORATORIES (UL) UNLESS NOTED OTHERWISE. TYPE OF SINGLE ITEM PENETRATION 1 HR ASSEMBLY "F" RATING 1 HR 2 HR ASSEMBLY "F" RATING 2 HR METALLIC CONDUIT 4"Ø OR SMALLER EMT CONDUIT 6"Ø OR SMALLER STEEL CONDUIT WJ1032 WJ1032 NON-METALLIC CONDUIT 2"Ø OR SMALLER SCH 40 PVC WJ2002 WJ2002 METALLIC PIPE/COPPER PIPE/TUBE 6"Ø OR SMALLER TYPE L OR HEAVIER TUBING 6"Ø OR SMALLER REGULAR OR HEAVIER PIPE WJ1032 WJ1032 NON-METALLIC PIPE/TUBE 2"Ø OR SMALLER SCH 40 PVC/CPVC 4"Ø OR SMALLER SCH 40 PVC/CPVC WJ2015 WJ2015 CABLE/WIRE W/ NON-COMB JACKETS/INSUL MAX 12 COPPER CONDUCTOR NO 12 AWG OR SMALLER W/ TVL INSUL & FLAMTROL JACKET WJ3015 WJ3015 NON-COMBUSTIBLE PIPES/TUBES/VENTS 6"Ø (MAX) TYPE L (OR HEAVIER) COPPER TUBE 6"Ø (MAX) REGULAR (OR HEAVIER) COPPER PIPE 24"Ø (MAX) SCH 10 (OR HEAVIER) STEEL PIPE 24"Ø (MAX) CAST OR DUCTILE IRON PIPE WJ1032 WJ1032 CABLE/WIRE W/ COMB JACKETS/INSUL MAX NO 10 AWG COPPER MULTI CONDUCTOR (NM) CABLE W/ PVC INSUL MAX 100 PAIR NO 24 AWG COPPER TELEPHONE CABLE W/ PVC INSUL WJ3013 WJ3013 COMBUSTIBLE PIPES/TUBES/VENTS 4"Ø (MAX) SCH 40 PVC/CPVC (DWV) PIPING 4"Ø (MAX) SCH 40 PVC/ABS/FRPP 8" OR 10"Ø SCH 40 PVC (DWV) PIPING WJ2012 WJ2012 PENETRATION TYPE LOCATION ASSEMBLY PENETRATION TEST STEEL PIPE 4"Ø OR SMALLER SCH 5 OR HEAVIER IRON PIPE 4"Ø OR SMALLER CAST OR DUCTILE CONDUIT 4"Ø OR SMALLER STL EMT OR STL CONDUIT COPPER TUBE 4"Ø OR SMALLER TYPE L OR HEAVIER L524 SYS #13 G514 F-C-1010 C-AJ-1338 PVC PIPE 4"Ø OR SMALLER SCH 40 SOLID OR HEAVIER SOLID CORE (DWV) RIGID NON-METALLIC CONDUIT 4"Ø OR SMALLER SCH 40 CPVC PIPE 4"Ø OR SMALLER SDR 17 (DWV) WIRE/CABLE L524 SYS #13 G514 L524 SYS #13 G514 F-C-2032 C-AJ-2002 F-C-3013 BATHTUB L524 SYS #13 F-C-2036 WATER CLOSET L524 SYS #13 G514 F-C-2037 F-A-2075 FLOOR DRAIN L524 SYS #13 G514 F-A-2037 F-A-2056 SEE FLOOR PLAN FOR WALL TYPE BLOCKING AS NEEDED FIRESEALANT @ PERIMETER OF BOX (TYP) MAX SIZE IS 16 SQ. INCHES FOR STEEL ELECTRICAL BOXES WITH A MAX OF 100 SQ. INCHES IN 100 SF. OF WALL AREA RATED WALL ASSEMBLY (1 HR SHOWN) PARTITION NOTES INTERIOR WALL TYPES SCHEDULE 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE FROM FINISHED WALLBOARD TO FINISHED WALLBOARD. 2. DIMENSIONS NOTED AS "(FIELD VERIFY)" SHALL BE CHECKED AT THE SITE BY THE CONTRACTOR AND REVIEWED BY THE ARCHITECT PRIOR TO THEIR INCORPORATION INTO THE WORK. 3. DIMENSIONS NOTED AS "(HOLD)" SHALL BE MAINTAINED WITHOUT VARIANCE. 4. DIMENSIONS NOTED AS "(N.T.S.)" ARE GREATER OR LESS THAN THE PHYSICAL RELATIONSHIP SHOWN. 5. DIMENSIONED WALL THICKNESSES ARE ACTUAL THICKNESSES UNLESS NOTED OTHERWISE. NOMINAL DIMENSIONS ARE USED TO DESCRIBE MATERIALS SUCH AS CONCRETE BLOCK, BRICK, AND WOOD FRAMING. DIMENSIONING METHOD 1. ALL PARTITIONS NOT OTHERWISE DESIGNATED WILL BE TYPE S3J. 2. REFER TO FLOOR PLANS AND LIFE SAFETY DRAWINGS FOR SMOKE PARTITION & FIRE SEPARATION WALL LOCATIONS. 3. PIPES, CABLE TRAYS, CONDUITS, ETC. WHEN PASS THRU A RATED ASSEMBLY SHALL BE PROVIDED WITH APPROPRIATE THRU PENETRATIONATED PROTECTION IN ACCORDANCE W/ UNDERWRITERS APPROVED SYSTEMS & PENETRATION SCHEDULES PROVIDED HEREIN. 4. WHERE PARTITIONS OF VARIOUS THICKNESSES MEET OR WHERE NEW WORK ADJOINS EXISTING CONSTRUCTION, A FLUSH SURFACE SHALL BE PROVIDED ON THE SIDE WHERE FACES ARE STRAIGHT & CONTINUOUS. 5. PARTITION TYPES INDICATED ON PLAN INDICATE THAT THE PARTITION TYPE SHALL RUN CONTINUOUS TO CORNER, EXTERIOR WALL, OR INTERSECTING PARTITION UNLESS NOTED OTHERWISE. 6. PARTITION TYPES REQUIRED TO BE RATED SHALL BE CONSTRUCTED IN ACCORDANCE W/ THE LISTED TESTING AGENCY ASSEMBLY INDICATED (UL = UNDERWRITERS LABORATORIES) ALL OTHER PARTITIONS SHALL BE CONSTRUCTED PER THE SPECIFICATIONS OR GENERALLY ACCEPTED CONSTRUCTION PRACTICES. 7. ALL LOCATIONS TO RECEIVE TILE SHALL HAVE CEMENT BACKER BOARD SUBSTITUTED FOR DRYWALL. 8. WALL AT WET LOCATIONS WHICH ARE NOT RECEIVING TILE SHALL HAVE MOISTURE AND MOLD RESISTANT DRYWALL FOR 4' EACH SIDE AND ABOVE WET LOCATION. 9. U.N.O. SOUND BATTS SHALL BE 3 1/2" AND SHALL BE FROM THE FLOOR TO 4" ABV THE CLG. NOTES: 1. TESTS NOTED ARE FOR SINGLE ITEM PENETRATIONS. ALL TEST DESIGNATIONS ARE UNDERWRITERS LABORATORIES (UL) UNLESS NOTED OTHERWISE. 2. FOR PENETRATIONS OTHER THAN THOSE LISTED REFER TO DWG LOCATION OF PENETRATION OR CURRENT UNDERWRITERS LABORATORY FIRE RESISTANCE DIRECTORY FOR PENETRATION TEST. ALL TEST DESIGNATIONS ARE UNDERWRITERS LABORATORIES (UL) UNLESS NOTED OTHERWISE. INTERIOR PARTITIONS LEGEND S3A S = CORE MATERIAL IDENTIFIER 3 = CORE MATERIAL THICKNESS A = WALL DETAIL MODIFIER CORE MATERIAL THICKNESS CONCRETE* 4 = 4" CONCRETE 6 = 6" CONCRETE 8 = 8" CONCRETE 12 = 12" CONCRETE MASONRY * 4 = 4" CMU 8 = 8" CMU 12 = 12" CMU * VERIFY ALL SIZES W/ STRUCTURAL DRAWINGS CORE MATERIAL INDENTIFERS C = CONCRETE M = MASONRY S = STEEL W = WOOD STEEL* 1 = 1 1/2" STUD 2 = 2 1/2" STUD 3 = 3 5/8" STUD 4 = 4" STUD 6 = 6" STUD WOOD* 1 = FURRING (SEE SPECS) 2 = 2X2 STUD 4 = 2X4 STUD 6 = 2X6 STUD WALL DETAIL MODIFIER A. BLANK B. BLANK C. BLANK D. ONE SIDED GYP -GYP. TO 6" ABV CEILING E. BLANK F. BLANK G. TWO SIDED GYP -GYP. TO 6" ABV CEILING H. TWO SIDED GYP -FULL HT. B.O. STRUCT/ DECK (1 HR. RATED) I. TWO SIDED GYP -KNEE WALL J. TWO SIDED GYP -FULL HT. B.O. STRUCT/ DECK (ACOUSTIC PARTITION) K. ONE SIDED GYP -FULL HT. B.O. STRUCT/ DECK (ACOUSTIC PARTITION) L. BLANK M. BLANK N. LEAD LINED PARTITION, STUDS FULL HEIGHT. ONE SIDED GYP BD TO 6" ABOVE CEILING, LEAD LINING TO 7'-0" A.F.F. (PER PHYSICIST REPORT). O. TWO SIDED GYP -FULL HT. B.O. STRUCT / DECK (ISO CLIP HIGH STC ACOUSTIC PARTITION) P. LEAD LINED PARTITION, STUDS FULL HEIGHT,OUTSIDE LAYER OF GYP.BD. FULL HT. INSIDE GYP BD TO 6" ABOVE CEILING, LEAD LINING TO 7'-0" A.F.F. INSIDE GYP BD (PER PHYSICIST REPORT). Q. 8" CMU PARTITION, COORDINATE WITH STRUCTURAL DRAWINGS (1 HR. RATED) R. TWO SIDED GYP -FULL HT. B.O. STRUCT / DECK (ISO CLIP HIGH STC ACOUSTIC PARTITION), LEAD LINING TO 7'-0" A.F.F. INSIDE GYP BD (PER PHYSICIST REPORT) UNDERSIDE OF STRUCTURE OR BRACING CEILING LINE 1 1/2" MTL STUD AT 16" O.C.SCHEDULED BASE (TYP.)FLOOR DEFLECTION TRACK UL RATING/ GA FILE NO.NO 6"MAX.1/2"UNDERCUT STUD 1/2" MIN. WALL TYPE -S1D 5/8" DRYWALL ONE SIDE ONLY INTERIOR PARTITION WALL CONSTRUCTION UNDERSIDE OF STRUCTURE OR BRACING CEILING LINE 3 5/8" MTL STUD AT 16" O.C.SCHEDULED BASE (TYP.)FLOOR DEFLECTION TRACK UL RATING/ GA FILE NO.NO 6"UNDERCUT STUD 1/2" MIN. WALL TYPE -S3D 5/8" DRYWALL ONE SIDE ONLYMAX.1/2"CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR UL RATING/ GA FILE NO.NO 6"WALL TYPE -S3GMAX.1/2"UNDERSIDE OF STRUCTURE OR BRACING CEILING LINE DEFLECTION TRACK UNDERCUT STUD 1/2" MIN. UNDERSIDE OF STRUCTURE CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK UL RATING/ GA FILE NO.STC-44 VARIESMAX.1/2"UNDERCUT STUD 1/2" MIN. WALL TYPE -S3J SOUND ATTENUATION SEAL TO RESIST THE PASSAGE OF SMOKE 5/8" GYPSUM BOARD ACOUSTICAL SEALANT (TYP) UNDERSIDE OF STRUCTURE CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK UL RATING/ GA FILE NO. UL U419 VARIESMAX.1/2"UNDERCUT STUD 1/2" MIN. WALL TYPE -S3H SOUND ATTENUATION FIRESTOP SEALANT (TYP) 5/8" GYPSUM BOARD FIRESTOP SEALANT (TYP) 1-HR RATED EXTEND FIRE RATING INTO DECK FLUTES 3 5/8" MTL STUD AT 16" O.C. UL RATING/ GA FILE NO.NO WALL TYPE -S3P UNDERSIDE OF STRUCTURE CEILING LINE DEFLECTION TRACK MAX.1/2"UNDERCUT STUD 1/2" MIN. LEAD LINING PER PHYSICIST REPORT 6"SCHEDULED BASE (TYP.) FLOOR SOUND ATTENUATION UL RATING/ GA FILE NO. NO WALL TYPE -S3O UNDERSIDE OF STRUCTURE CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK MAX.1/2"UNDERCUT STUD 1/2" MIN. 5/8" DRYWALL SOUND ATTENUATION ACOUSTICAL SEALANT ACOUSTICAL SEALANT (2) 5/8" DRYWALL 25 ga, 7/8" x 2-9/16" FURRING CHANNEL ISO CLIP (ISOMAX BY KNC OR EQUAL) 7 1/4" UL RATING/ GA FILE NO.NO WALL TYPE -S3R UNDERSIDE OF STRUCTURE CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK MAX.1/2"UNDERCUT STUD 1/2" MIN. 5/8" DRYWALL SOUND ATTENUATION ACOUSTICAL SEALANT ACOUSTICAL SEALANT (2) 5/8" DRYWALL 25 ga, 7/8" x 2-9/16" FURRING CHANNEL ISO CLIP (ISOMAX BY KNC OR EQUAL) 7 1/4" LEAD LINING PER PHYSICIST REPORT 3 5/8" MTL STUD AT 16" O.C. UL RATING/ GA FILE NO.NO WALL TYPE -S3N UNDERSIDE OF STRUCTURE CEILING LINE DEFLECTION TRACK MAX.1/2"UNDERCUT STUD 1/2" MIN. LEAD LINING PER PHYSICIST REPORT 6"FLOOR SOUND ATTENUATION UL RATING/ GA FILE NO.STC-34 WALL TYPE -S3K UNDERSIDE OF STRUCTURE CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK MAX.1/2"UNDERCUT STUD 1/2" MIN. SOUND ATTENUATION SEAL TO RESIST THE PASSAGE OF SMOKE 5/8" GYPSUM BOARD ACOUSTICAL SEALANT (TYP) UNDERSIDE OF STRUCTURE FLOOR UL RATING/ GA FILE NO. 1 HR RATED UL U905 WALL TYPE -M8Q 8" CMU FIRE RATED SEALANT AND BACKER ROD MINERAL WOOL CEILING LINE UNDERSIDE OF STRUCTURE CEILING LINE 3 5/8" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK UL RATING/ GA FILE NO. UL U419 VARIESMAX.1/2"UNDERCUT STUD 1/2" MIN. WALL TYPE -S3L SOUND ATTENUATION FIRESTOP SEALANT (TYP) 5/8" GYPSUM BOARD FIRESTOP SEALANT (TYP) 1-HR RATED EXTEND FIRE RATING INTO DECK FLUTES UNDERSIDE OF STRUCTURE OR BRACING CEILING LINE 1 1/2" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) FLOOR DEFLECTION TRACK UL RATING/ GA FILE NO.NO 6"MAX.1/2"UNDERCUT STUD 1/2" MIN. WALL TYPE -S1M 5/8" DRYWALL ONE SIDE ONLY SOUND ATTENUATION LEAD LINING PER PHYSICIST REPORT LEAD LINING PER PHYSICIST REPORT UL RATING/ GA FILE NO.NO WALL TYPE -S6F UNDERSIDE OF STRUCTURE CEILING LINE 6" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) UNDERCUT STUD 1/2" MIN. SOUND ATTENUATION SEAL TO RESIST THE PASSAGE OF SMOKE VARIESMAX.1/2"FLOOR DEFLECTION TRACK 5/8" GYPSUM BOARD ACOUSTICAL SEALANT (TYP) UL RATING/ GA FILE NO. WALL TYPE -S6H UNDERSIDE OF STRUCTURE CEILING LINE 6" MTL STUD AT 16" O.C. SCHEDULED BASE (TYP.) UNDERCUT STUD 1/2" MIN. SOUND ATTENUATION FIRESTOP SEALANT (TYP)VARIESMAX.1/2"FLOOR DEFLECTION TRACK 5/8" GYPSUM BOARD FIRESTOP SEALANT (TYP) EXTEND FIRE RATING INTO DECK FLUTES UL U4191-HR RATED © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 INTERIOR PARTITION SCHEDULE 04 MARCH 2022 A0.02MEDVET INDIANAPOLIS -ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITIONWALL CONSTRUCTION TERMINATION FIRE RATING STC RATING COMMENTSDESIGNATION SIDE 1 CORE SIDE 2 5/8" GYP BD 3 5/8" MTL STUDS 5/8" GYP BD STUDS & GYP BD LOW WALL HT AS INDICATED - - -- M8Q ---8" RUNNING BOND - - - FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY 1 HOUR FIRE BARRIER, UL# U905 1 - HOUR WALL - SEE PLAN FOR OTHER PARTITION TYPES THAT MAY BE ASSOCIATED WITH THE CMU WALL.. COORDINATE WITH STRUCTURAL DRAWINGS. S1D 5/8" GYP BD 1 1/2" MTL STUDS - - - STUDS FULL HT, GYP BD 6" ABV CLG OR TO DECK W/ NO CLG - - -- S1M 5/8" GYP BD 1 1/2" MTL STUDS - - - STUDS FULL HT, GYP BD 6" ABV CLG OR TO DECK W/ NO CLG - - -- S3D 5/8" GYP BD 3 5/8" MTL STUDS - - - STUDS FULL HT, GYP BD 6" ABV CLG OR TO DECK W/ NO CLG - - -- S3G 5/8" GYP BD 3 5/8" MTL STUDS 5/8" GYP BD STUDS FULL HT, GYP BD 6" ABV CLG OR TO DECK W/ NO CLG - - -- S3H 5/8" GYP BD 3 5/8" MTL STUDS 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY 1 HOUR FIRE BARRIER, UL# U419 STC 44 1 - HOUR WALL S3J 5/8" GYP BD 3 5/8" MTL STUDS 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY - - - STC 44 ACOUSTIC PARTITION S3K 5/8" GYP BD 3 5/8" MTL STUDS - - - FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY - - - STC 34 S3L 5/8" GYP BD 3 5/8" MTL STUDS 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY 1 HOUR FIRE BARRIER, UL# U419 STC 44 1 - HOUR WALL S3N 5/8" GYP BD - LEAD LINED INSIDE LAYER OF SPACE 3 5/8" MTL STUDS - - - STUDS FULL HT, ONE SIDE TO 6" ABV CLG - - -STC 34 LEAD LINED GYP. BD. (PER PHYSICIST REPORT) ON INSIDE LAYER TO 7'-0" A.F.F. S3O 5/8" GYP BD 3 5/8" MTL STUDS WITH ISO CLIPS (2) 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY - - -STC 60 ACOUSTIC PARTITION, PROVIDE ACOUSTICAL BATT INSULATION AND ACOUSTICAL SEALANT AT ALL PENETRATIONS. S3P 5/8" GYP BD - LEAD LINED INSIDE LAYER OF SPACE 3 5/8" MTL STUDS 5/8" GYP BD STUDS FULL HT, ONE SIDE TO 6" ABV CLG OTHER SIDE TO DECK - - -STC 44 LEAD LINED GYP. BD. (PER PHYSICIST REPORT) ON INSIDE LAYER TO 7'-0" A.F.F. S3R 5/8" GYP BD - LEAD LINED INSIDE LAYER OF SPACE 3 5/8" MTL STUDS WITH ISO CLIPS (2) 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY - - -STC 60 ACOUSTIC PARTITION, PROVIDE ACOUSTICAL BATT INSULATION AND ACOUSTICAL SEALANT AT ALL PENETRATIONS. LEAD LINED GYP. BD. (PER PHYSICIST REPORT) ON INSIDE LAYER TO 7'-0" A.F.F.. S6H 5/8" GYP BD 3 5/8" MTL STUDS 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY 1 HOUR FIRE BARRIER, UL# U419 STC 44 1 - HOUR WALL S6J 5/8" GYP BD 6" MTL STUDS 5/8" GYP BD FULL HT TO UNDERSIDE OF DECK OR FIRE RESISTANCE RATED ASSEMBLY - - -STC 44 ACOUSTIC PARTITION 1 2022-03-17 Addendum 01 1 1 1 1 1 07/13/22