HomeMy WebLinkAboutA0.04 ACCESSIBILITY STANDARDSbuilding blocks accessible route accessible lavatories and water closets accessible kitchens, break rooms, & appliances accessible showers and bathing facilities 4'-6" MINIMUM 3'-3" MIN 3'-5" MAX 1'-6" MINEQUAL2'-10" MAX2'-1" MAX TO F/ CFS 2'-9 MIN3'-0" MAX3'-6" MIN 1'-0" MAX LENGTH OF TUB5'-0" MINIMUM2'-8" MIN 1'-3" MIN1'-4" MAX4'-2" MIN 5'-0" MIN1'-3"1 1/2"4'-2" MIN 5'-2" MIN ≤2'-0"*4'-2" MIN3'-3" MIN3'-5" MAXEQUAL 4'-2" MIN 2'-8" MIN2'-8" MIN 4'-2" MIN1'-5" MIN2'-1" MAX2'-1"MAXWHICHEVER IS HIGHER4'-2" MIN 2'-8" MINEQ EQ 3'-0" MAX FOR LO3'-2" TO 3'-7" FOR HI2'-3" MIN≥4" NTS OBSTRUCTED HIGH FORWARD REACH UNOBSTRUCTED FORWARD REACH NOTE: 2'-6" MIN WIDE CLEAR FLOOR SPACE MUST BE PROVIDED UNDER OBSTRUCTION. MAXIMUM REACH DEPTH IS 2'-1" UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH CLEAR FLOOR SPACE PARALLEL APPROACH FORWARD APPROACHCIRCULAR TURNING SPACE NOTE: THE TURNING SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES 'T'-SHAPED TURNING SPACE NOTE: THE TURNING SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES ONLY AT EITHER BASE OR THE END OF EITHER ARM KNEE AND TOE CLEARANCES NOTE: CLEAR FLOOR WIDTH AT KNEE AND TOE CLEARANCE SPACE SHALL BE 2'-8" MINIMUM. ADDITIONAL SPACE BEYOND KNEE AND TOE CLEARANCES SHALL BE PERMITTED BENEATH ELEMENTS. LIMITS OF PROTRUDING OBJECTS NOTE: HANDRAILS MAY PROTRUDE 4-1/2" AND DOOR CLOSERSAND DOOR STOPS SHALL BE PERMITTED TO BE 6'-6" A.F.F. REDUCED VERTICAL CLEARANCE NOTE: WHERE VERTICAL CLEARANCE IS LESS THAN 6'-8" A.F.F. AND EXTENDS BEYOND 4" FROM THE SIDE WALL, A BARRIER MUST BE PROVIDED. THE LEADING EDGE OF SUCH BARRIER SHALL BE 2'-3" MAXIMUM A.F.F. AND BE LESS THAN 4" FROM THE POINT OVERHEAD WHERE THE OBSTRUCTION BEGINS CARPET EDGES NOTE: EXPOSED EDGES OF CARPET SHALL HAVE TRIM ALONG THE ENTIRE EDGE OF THE ENTIRE LENGTH OF THE EXPOSED EDGE CARPET SHALL BE SECURELY ATTACHED, IF CUSHIONED IT SHALL BE FIRM, AND THE PILE SHALL BE 1/2" MAXIMUM IN HEIGHT VERTICAL CHANGE IN LEVEL RAMPED CHANGE IN LEVELBEVELED CHANGE IN LEVEL 2 1 DIMENSIONS ARE TO THE BOTTOM OF THE LOWER RECEPTACLE, NOT THE OF THE OUTLET OUTLETS, SWITCHES, & ENVIRONMENTAL CONTROL HEIGHTS AREA OF REFUGE SIGNAGE HEIGHT ALL CHARACTERS MUST BE HIGH CONTRAST, TACTILE CHARACTERS SHALL BE RAISED 1/32" MIN ABOVE THEIR BACKGROUND. ACCESSIBLE LAVATORY A 32"x50" CLEAR FLOOR AREA SHALL BE PROVIDED UNDER THE LAVATORY PER THE INDICATED DIMENSIONS WITH FULL KNEE AND TOE CLEARANCES, THUS CABINETS ARE NOT PERMITTED UNDER THE LAVATORY WITHIN THE REQUIRED CLEAR FLOOR AREA. FRONT EDGE OF VANITY COUNTERTOP COUNTERTOP MOUNTED LAVATORY WALL-HUNG LAVATORY FRONT EDGE OF CLEAR FLOOR SPACE EDGE OF REQUIRED KNEE AND TOE CLEARANCES LAVATORY SECTION INSULATED PIPE PROTECTION AT DRAIN AND HOT WATER SUPPLY ACCESSIBLE WATER CLOSET A CLEAR FLOOR AREA POSITIONED FOR A FORWARD OR PARALLEL APPROACH SHALL BE PROVIDED AT THE WATER CLOSET PER THE LOCATION ABOVE. NOTHING SHALL BE PERMITTED IN THE CLEAR FLOOR AREA EXCEPT FOR GRAB BARS AND OTHER TOILET ROOM ACCESSORIES, ACCESSIBLE ROUTES, TURING RADII, AND OTHER FIXTURES' CLEAR FLOOR AREAS. NO OTHER FIXTURES OR OBSTRUCTIONS ARE PERMITTED IN THE CLEAR FLOOR AREA. FLUSH CONTROLS SHALL BE ON APPROACH SIDE OF TOILET WATER CLOSET MAY BE TANK, FLOOR MOUNTED FLUSH VALVE, OR WALL HUNG FLUSH VALVE. ACCESSIBLE WATER CLOSET REAR WALL GRAB BARS ACCESSIBLE WATER CLOSET SIDE WALL GRAB BARS *DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY OR PROHIBIT A CONTINUOUS PAPER FLOW DISPENSER LOCATION* ACCESSIBLE URINAL A CLEAR FLOOR SPACE, POSITIONED FOR A FORWARD APPROACH, SHALL BE PROVIDED AND CENTERED ON THE FIXTURE. NOTHING SHALL BE PERMITTED IN THE CLEAR FLOOR AREA EXCEPT FOR THE FIXTURE ITSELF. FLUSH CONTROLS SHALL BE AUTOMATIC OR HAND CONTROLLED. IF HAND CONTROLLED, THEY SHALL BE WITHIN APPLICABLE REACH RANGES. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1 1/4" TO 1 1/2" OUTSIDE DIAMETER, OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF HANDRAILS OR GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1 1/2". ACCESSIBLE LAVATORY SECTION LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER SURFACE NO HIGHER THAN 34 IN ABOVE THE FINISH FLOOR. PROVIDE A CLEARANCE OF AT LEAST 27 IN ABOVE THE FINISH FLOOR TO THE BOTTOM OF THE APRON. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. ACCESSIBLE BATHTUB w/ REMOVABLE SEAT ACCESSIBLE BATHTUB w/ PERMANENT SEAT CONTROL ENDWALL CONTROL ENDWALL NOTHING SHALL BE PERMITTED IN THE CLEAR FLOOR AREA EXCEPT FOR GRAB BARS AND OTHER TOILET ROOM ACCESSORIES, ACCESSIBLE ROUTES, TURNING RADII, AND OTHER FIXTURES' CLEAR FLOOR AREAS. NOTHING SHALL BE PERMITTED IN THE CLEAR FLOOR AREA EXCEPT FOR GRAB BARS AND OTHER TOILET ROOM ACCESSORIES, ACCESSIBLE ROUTES, TURNING RADII, AND OTHER FIXTURES' CLEAR FLOOR AREAS. ACCESSIBLE BATHTUB GRAB BARS AND CONTROLS CONTROL (FOOT) WALL BACK WALLHEAD WALL THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1 1/4" TO 1 1/2" OUTSIDE DIAMETER, OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF HANDRAILS OR GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1 1/2". TUB FACUET CONTROLS SHALL BE IN THE LOCATION SHOWN. A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60" LONG THAT CAN BE USED AS BOTH A FIXED SHOWER HEAD AND AS A HAND-HELD SHOWER SHALL BE PROVIDED. BACK WALL CONTROL WALL ACCESSIBLE TRANSFER SHOWER GRAB BARS AND CONTROLSCONTROL (FOOT) WALLHEAD WALLHEAD WALL@ TUB W/FIXED SEATBACK WALLBACK WALLCONTROL LOCATION ADJUSTABLE HANDSHOWER W/ 60" MIN HOSE ACCESSIBLE TRANSFER SHOWER w/ FOLD-DOWN SEAT SHOWER SEAT SHALL BE 17"-19" A.F.F. , 15" MIN WIDE, AND THE FULL DEPTH OF THE SHOWER STALL.CONTROL WALLSEAT WALLBACK WALLSEAT WALLCONTROL LOCATION FRONTTHE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1 1/4" TO 1 1/2" OUTSIDE DIAMETER, OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE. IF HANDRAILS OR GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE 1 1/2". SHOWER FAUCET CONTROLS SHALL BE IN THE LOCATION SHOWN. A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 60" LONG THAT CAN BE USED BOTH AS BOTH A FIXED SHOWER HEAD AND AS A HAND-HELD SHOWER SHALL BE PROVIDED. ADJUSTABLE HANDSHOWER W/ 60" MIN HOSE ACCESSIBLE UNIT ROLL-IN SHOWER A LAVATORY WITH KNEE & TOE CLEARANCES ARE PERMITTED ON THE CONTROL END OF THE SHOWER. SHOWER DIMENSIONS ARE MEASURED FROM THE INSIDE FACE OF THE FINISHED SHOWER WALL. NOTE: THE CLEAR FLOOR SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCES SIGNAGE CLEAR FLOOR SPACE ALL REQUIRED SIGNS MUST HAVE A 1'-8" x 1'-8" MIN CLEAR FLOOR SPACE ON THE LATCH SIDE OF THE DOOR WITH THE SIGN MOUNTED IN THE CENTER OF THE CLEAR FLOOR SPACE CHANGES IN LEVEL NOTE: DIAGRAMS ARE NOT TO SCALE PUSH SIDE: FRONT APPROACH PUSH SIDE: FRONT APPROACH W/ CLOSER AND LATCH PUSH SIDE: HINGE APPROACH PUSH SIDE: HINGE APPROACH W/ CLOSER AND LATCH PUSH SIDE: LATCH APPROACH PUSH SIDE: LATCH APPROACH WITH CLOSER PULL SIDE: FRONT APPROACH PULL SIDE: HINGE APPROACH OPTION 1 PULL SIDE: HINGE APPROACH OPTION 2 PULL SIDE: LATCH APPROACH OPTION 1 PULL SIDE: LATCH APPROACH OPTION 2 BIFOLD,BIPASS, OR POCKET DOOR: STOP APPROACH RECESSED DOOR: WHEN DOOR IS RECESSED MORE THAN 7", CLEAR FLOOR AREA FOR A FRONT APPROACH W/ CLOSER AND LATCH MUST BE USED DOORWAYS WITHOUT DOORS: REQUIRED WIDTH AND CLEAR FLOOR AREA BIFOLD, BIPASS, OR POCKET DOOR: HINGE OR POCKET APPROACH DOOR AND DOORWAY MANEUVERING CLEARANCES NOTE: DIAGRAMS ARE NOT TO SCALE TWO DOORS IN A SERIES ACCESSIBLE SINK A CLEAR FLOOR SPACE, POSITIONED FOR A PARALLEL OR FORWARD APPROACH, SHALL BE PROVIDED AND CENTERED ON THE FIXTURE. A FORWARD APPROACH IS ONLY REQUIRED IF A STOVE OR RANGE IS ALSO PROVIDED. THE SINK SHALL BE NO HIGHER THAN 34" A.F.F. FAUCET CONTROLS SHALL BE AUTOMATIC OR HAND CONTROLLED. IF HAND CONTROLLED, THEY SHALL BE WITHIN APPLICABLE REACH RANGES AND USABLE WITHOUT PINCHING, GRASPING TIGHTLY, OR REQUIRE TWISTING OF THE WRIST. PARALLEL APPROACH FORWARD APPROACH INSULATED PIPE PROTECTOR IF LEFT OPEN LINE OF KNEE & TOE CLEARANCE. IF FOOD GRINDER IS PROVIDED, IT MUST FALL BEHIND THIS LINE SECTION AT FORWARD APPROACH WASHER OR DRYER CLEAR FLOOR AREA MUST BE CENTERED ON THE APPLIANCE. WASHER AND DRYER SHALL HAVE CONTROLS WITHIN THE REACH RANGE. FRONT LOADING DOORS SHALL BE 1'-3" MIN TO THE BOTTOM OF THE DOOR AND 2'-10" MAX TO THE TOP OF THE DOOR COOKTOP/RANGE CONTROLS MUST BE LOCATED AS TO NOT REQUIRE REACHING OVER ANY BURNER. VENT HOOD CONTROLS MUST BE LOCATED WITHIN THE REACH RANGES REFRIGERATOR/FREEZER AT LEAST 50% OF THE FREEZER COMPARTMENT SHELVES INCLUDING THE BOTTOM OF THE FREEZER SHALL BE 46" A.F.F. MAX DISH WASHER DISHWASHER CLEAR FLOOR AREA MUST BE BEYOND OR ADJACENT TO THE SWING OF THE DISHWASHER DOOR. DRINKING FOUNTAIN A CLEAR FLOOR SPACE MUST BE PROVIDED FOR THE LOW DRINKING FOUNTAIN. BOTH HIGH AND LOW SHALL NOT PROJECT BEYOND THE SURROUNDING WALL MORE THAN 3-1/2". WATER STREAM SHALL EXTEND 4" ABOVE SPOUT OUTLET NOTE: THESE DIAGRAMS ARE BASED ON THE AMERICANS WITH DISABILITIES ACT ACCESSIBLE GUIDLINES, 2010 EDITION AS WELL AS ANSI A117.1-2009. NOT ALL CONDITIONS SHOWN MAY EXIST IN THE PROJECT. CONTRACTOR SHALL REVIEW ALL DIAGRAMS PRIOR TO LAYOUT AND VERIFY ALL CLEAR AREAS, MOUNTING HEIGHTS, AND OTHER CLEARANCES AS SHOWN ARE PROVIDED. MATERIALS, PRODUCTS AND SIZES OF FIXTURES AND EQUIPMENT SHOWN MAY NOT REFLECT THE ACTUAL PRODUCTS OR MATERIALS SPECIFIED IN THE ARCHITECTURAL DRAWINGS. REFER TO THE ACTUAL PRODUCT SPECIFIED OR PROVIDED FOR VERIFICATION. TACTILE SIGN PERMITTED ON PUSH SIDE OF DOORS WITH A CLOSER2' - 8"2' - 10"MAX2' - 3"MINMIN9"MIN 8" MIN 11" MIN 6" 2' - 1" MAX 1' - 5"MIN MIN IMUM ø 5' - 2" 5' - 2"MINIMUM MINIMUM 1' - 0" MINIMUM 3' - 2" MINIMUM 1' - 0"MIMIMUM3' - 2"MINIMUM2' - 0"MINIMUM5' - 2"4' - 2" NOTHING SHALL BE PERMITTED IN THE CLEAR FLOOR AREA EXCEPT FOR GRAB BARS AND OTHER TOILET ROOM ACCESSORIES, ACCESSIBLE ROUTES, TURING RADII, AND OTHER FIXTURES' CLEAR FLOOR AREAS. THRESHOLDS FOR TRANSFER SHOWERS SHALL BE 1/2" HIGH 2 1 DOOR ACTUATOR BUTTON CLEAR FLOOR AREA CENTERED ON BUTTON AND BEYOND THE SWING OF ANY DOOR DOOR OPERATOR: REQUIRED CLEAR FLOOR AREA 1 234 567 18 17 16 15 14 13 12 9 8 1011 19 20 21 22 33 31 30 29 28 27 26 25 24 23 32 TO. F/ CFS2'-1" MAXEQ EQ 4'-2" MIN2'-8" MINF/ VANITY1'-5" MIN TOF/ SINK1'-5" MIN TOEQ EQ TO F/ CFS2'-1" MAX4'-2" MIN2'-8" MIN T/ SINK RIM2'-10" MAX TO2'-3" MINF/ VANITY OR SINK 1'-5" MIN TO 8" MIN 11" MIN 6" MAX 9" MIN.5' - 2" MIN HOLD 1' - 5" SIDE OPPOSITE APPROACH 3'-0" MAX2'-9" MINSEAT HT1'-5" - 1'7"MIN 2' - 0" MIN 1' - 0" 6" MAX HOLD 1' - 5" 3' - 5" MIN TO URINAL LIP1'-1 1/2" MINEQ EQ 4' - 2" MIN2' - 8" MIN IF MANUALLY CONTROLLED3' - 7" MAXTO URINAL LIP 1'-1 1/2" MIN URINAL LIP1' - 5" MAXSINK RIM OR COUNTER2'-10" MAX A.F.F. TOA.F.F.2' - 3" MIN2'-8" MIN4'-2" MIN EQ EQ 4'-2" MIN 2'-8" MINEQ EQ 2'-8" MIN4'-2" MIN NTS NTS 2' - 8"MINSEAT DEPTH1' - 4" MINLENGTH OF TUB5' - 0"MIN3'-0" MAX2'-9" MIN6" MAX3"MINMIN1' - 6"1 1/2"MIN1" 2' - 0"MIN EQ EQ 3'-0" MAX2'-9" MINMIN 1' - 0" 1" @ TUB W/ FIXED SEATING 4'-0" MIN @ TUB W/ FIXED SEAT 1'-3" MAX MAX 1' - 0" MIN 2' - 0" MAX 2' - 0"3'-0" MAX2'-9" MIN3'-0" WIDE ENTRY MIN3' - 2"3'-0" HOLDCONTROL WALLBACK WALL 3' - 0" HOLD MIN 1' - 6"MAX4' - 0"MIN3' - 2"2' - 10" MIN 2" MAX 1' - 6" 4" MAX MIN1' - 6"6" MAX3" MIN3'-0" MAX2'-9" MINMIN 1' - 4"5'-0" MIN5'-0" MIN.2' - 8" MIN 2' - 6" MIN 5" MAX1'-3" MIN2'-8" MIN MIN 1' - 4"3 1/2" MAXMIN4' - 2"3'-2" TO 3'-7" FOR HI3'-0" MAX FOR LO>2' - 3"MAX 4"≥6' - 8"<4" ≥4"MAX2' - 3"<6'-8"1/4" MAX1/4" MAX1/4" MAX1/2" MAX1/4" MIN1/4" MAX4'-2" MIN+0'-2" MIN DOOR WIDTH 4'-2" MIN1'-2" MIN + 1'-2" MIN DOOR WIDTH + 2'-2" MIN DOOR WIDTH 3'-8" MIN2'-2" MIN 4'-2" MIN+ 2'-2" MIN DOOR WIDTH 2'-2" MIN + 2'-2" MIN DOOR WIDTH 3'-8" MIN2'-2" MIN 4'-2" MIN2'-2" MIN + 2'-2" MIN DOOR WIDTH + 2'-2" MIN DOOR WIDTH 3'-8" MIN2'-8" MIN 2'-2" MIN 4'-2" MIN FRONT3'-8" MIN SIDE> 2'-0"≤ 2'-0"**2'-8" CLEAR MIN 3'-2" CLEAR MIN 1'-4"EQ1'-4"EQDOORS SWING OUT 5'-2" MIN WHEN BOTH BOTH DOOR SWING OUT5'-2" MIN WHEN BOTHDOOR SWINGS IN D.W. + 1'-8" MIN WHENBOTH DOORS SWING IND.W. + 4'-2" + D.W. MIN WHENONE DOOR SWINGS IND.W. + 4'-2" MIN WHEN(D.W.)DOOR WIDTH4'-2" MIN+1'-2" MINDOOR WIDTH1'-2"MIN1'-8"MIN>7" >7"+ 1'-8" MINDOOR WIDTH2'-8" MIN 2'-2" MIN 3'-8" MIN+ 2'-2" MIN OPEN WIDTH + 3'-8" MIN DOOR WIDTH4'-8" MIN3'-8" MIN 2'-2" MIN 4'-2" MIN+ 2'-2" MIN DOOR WIDTH + 3'-8" MIN DOOR WIDTH4'-8" MIN3'-8" MIN 1'-8"MIN3'-2" MIN + 3'-2" MIN DOOR WIDTH4'-2" MIN2'-2"MIN5'-2" MIN+ 1'-8" MIN DOOR WIDTH 1'-8" MIN3'-11" MAX1'-4" MIN3'-11" MAX1'-4" MINMAX 10"2' - 3" MIN2'-10" MAX*3'-7" MAX3'-11" MAX*>1'-8" TO 2'-1" MAX 1'-8" MAX *3'-7" MAX3'-11" MAX2'-10" MAX*>10" TO 2'-0" 10" MAX MIN1' - 4"3'-7" MAX OBSTRUCTED REACH3'-11" MAX UNOBSTRUCTED REACHDIMENSIONS ARE TO THE TOP OF THE OPERABLE PART, NOT THE OF THE DEVICE MIN 10" MIN 1' - 8"1' - 8" MINTACTILE CHARACTERS4'-11" MAX FOR4'-1" MIN FOR TACTILE SIGNS3'-5" FOR VISUAL CHARACTERS4'-11" MAX4'-1" MIN2" MAX5/8" MINNTS NTS 9" MAX 7" MIN © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 ACCESSIBILITY STANDARDS 04 MARCH 2022 A0.04MEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION07/13/22