Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A0.50 FIRST FLOOR LIFE SAFE PLAN
CODE DATA INFORMATION LIFE SAFETY DEVICES LEGEND FIRE EXTINGUISHER FIRE EXTINGUISHER MRI (NON-FERROUS) EXIT DOOR CARD READER FE WALL RATING LEGEND GENERAL LIFE SAFETY NOTES: 1. PROVIDE STENCIL OF WALL RATING ON ALL WALLS WITHIN THE LIMITS OF CONSTRUCTION. STENCIL TO BE RED, 3" HIGH LEGIBLE LETTERING, MINIMUM OF 5'-0" O/C ALONG THE FULL WALL LENGTH, ABOVE CEILING. 2. WALL RATINGS SHOWN ON EXISTING WALLS DENOTE EXISTING WALL RATINGS AS PROVIDED BY THE OWNER. WITHIN THE LIMIT OF CONSTRUCTION, REPAIR / FIRE/STOP WALLS TO MEET EXISTING WALL RATINGS. 3. REFER TO DOOR SCHEDULE FOR DOOR RATING REQUIREMENTS. 0 HOUR SMOKETIGHT PARTITION BUILT TIGHT TO UNDERSIDE OF FLOOR / ROOF DECK ABOVE (EXG) SMOKE BARRIER (EXG) 1/2 HOUR FIRE BARRIER (EXG) ONE-HOUR RATED FIRE BARRIER (EXG) TWO-HOUR RATED FIRE BARRIER (EXG) THREE-HOUR RATED FIRE BARRIER (EXG) PROJECT DESCRIPTION: TURNKEY ANIMAL HOSPITAL FOR MEDVET. ANIMAL HOSPITAL IS A 15,205 SF. RENOVATION AND 15,100 SF. ADDITION OF A TWO STORY 30,305 SQUARE FOOT BUILDING SET ON AN EXISTING 4.5 ACRE SITE. CODE SUMMARY: SITE ZONING: RENOVATION / ADDITION APPLICABLE BUILDING CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL MECHANICAL CODE 2006 INTERNATIONAL PLUMBING CODE 2009 INDIANA ELECTRIC CODE 2016 NFPA 72 FOR FIRE ALARMS INDIANA BUILDING CODE 2014 EDITITION (ANSI A117.1-2009) 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL FUEL GAS CODE SAFETY CODE FOR ELEVATORS AND ESCALATORS (ASME A17.1,2007) INDIANA ENERGY CONSERVATION CODE (ANSI/ASHRAE 90.1, 2007) NOTE: ALL MODEL CODES WITH INDIANA AMENDMENTS EXISTING BUILDING DESIGN DATA: -USE GROUP: B BUSINESS -CONSTRUCTION TYPE: II-B TYPE OF WORK PROPOSED: NEW BUILD BUILDING HEIGHT PER IBC 504 - 55' (35'-6" ACTUAL HEIGHT) AREA OF WORK :AREA OCCUPANTS (IBC, TABLE 1004.1.2) FIRST FLOOR: BUSINESS B @ 100 SF GROSS/OCCUPANT:18,838 SF 190 SECOND FLOOR: BUSINESS B @ 100 SF GROSS/OCCUPANT:10,895 SF 109 ASSEMBLY A @ 15 SF NET/OCCUPANT: 572 SF 39 TOTAL:30,305 SF 338 MAXIMUM ALLOWABLE FLOOR AREA (IBC 506.2)92,000 SF FIRE SUPPRESSION AND MONITORING DATA THE BUILDING IS FULLY SPRINKLED. SPRINKLERS WILL BE MODIFIED TO ACCOMMODATE THE NEW TENANT LAYOUT. AUTOMATIC FIRE DETECTION SYSTEM IS EXISTING. SYSTEM WILL BE MODIFIED TO ACCOMMODATE THE NEW TENANT LAYOUT. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (IBC TABLE 601) PRIMARY STRUCTURAL FRAME: 0 HR BEARING WALLS: EXTERIOR 0 HR INTERIOR 0 HR NONBEARING WALLS EXTERIOR (IBC TABLE 602): 0 HR INTERIOR: 0 HR FLOOR CONSTRUCTION: 0 HR ROOF CONSTRUCTION: 0 HR CORRIDORS (SPRINKLERED) 0 HR (IBC 1018.1) EGRESS: MIN. STAIRWAYS EGRESS WIDTH REQ. (IBC 1009.4): 44" MIN. STAIRWAYS EGRESS WIDTH PROVIDED: 44" MIN. EGRESS WIDTH REQ. (IBC 1005.3.1 EXCEPTION 1): 67.6 IN. EGRESS WIDTH PROVIDED: 192 IN. NUMBER OF EXITS REQ. (IBC 1015.1): 2 NUMBER OF EXITS PROVIDED: 6 MIN. CORRIDOR WIDTH (IBC 1018.2): 44" MAX. COMMON PATH OF TRAVEL DISTANCE (SPRINKLERED) IBC 1021.2.b: 100'-0" MAXIMUM EXIT ACCESS TRAVEL DISTANCE (SPRINKLERED) IBC 1016.2: 300'-0" MAXIMUM DEAD END CORRIDOR LENGTH (SPRINKLERED) IBC 1018.4: 50'-0" INTERIOR WALL AND CEILING FINISH REQUIREMENTS (IBC TABLE 803.9) CLASS INTERIOR EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS: B CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS: C ROOMS AND ENCLOSED SPACES: C PLUMBING (INDIANA BUILDING CODE (2014 EDITION) TABLE 2902.1): CLASSIFICATION: BUSINESS OCCUPANCY: B (338 occupants = 169 Men & 169 Women) SPACE USE LOAD RATIO 1 PER 25 FOR THE FIRST 50, 1 PER 50 FOR REMAINING M 2 RATIO 1 PER 25 FOR THE FIRST 50, 1 PER 50 FOR REMAINING F WATER CLOSETS RATIO 1 PER 40 FOR THE FIRST 80, 1 PER 80 FOR REMAINING M 2 F LAVATORIES 1 PER 100 SERVICE SINK 3.38 1338 B SUBTOTAL 4.38 3.1 3.38 1 5 4 4 1 5 5 4 - REQUIRED PROVIDED 1 DRINKING FOUNTAINS RATIO REQUIRED F M 169 169 EXIT FE MRI 2.38 2 4.38 5 5 2.38 1.1 2 3.1 4 5 1.1 CR AREA SHELLED AT TIME OF THIS CONSTRUCTION COMPLETION x1x5 x6 x6.5 x7 x8 x10 87 6 5 4 3 2 1 2.2 DD F A A C C BB x11 x5.5 E xA xB xC xD xE xF WAITING ROOM 101 EX STAIR S101 RR 105T EXAM 2 122 EXAM 6 126 RR 106T TRIAGE 107A TRAUMA 108 PHARMACY 109 CAT WARD 110 ISOLATION 111B ANTE 111A ISOLATION 111 ICU 112 CLINCAL TEAM 107B ER/TRIAGE 107 PROCEDURE ROOM 107C XRAY 113 RR 114T JAN. 107D WARD 115 BARKING ROOM 115A ? ? ONCOLOGY SHELL SPACE 117 CARDIOLOGY 118 ECHO 118C RR 119T ELEVATOR SURGERY RECEIVING 141 DOCTORS OFFICE 142 EX MEP 120 MEP 135 EXAM 1 121 EXAM 3 123 EXAM 4 124 EXAM 5 125 EXAM 8 128 EXAM 7 127 EXAM 15 136 GRIEF 138 GRIEF 137 EXAM 12 132 EXAM 11 131 EXAM 10 130 EXAM 13 133 EXAM 14 134 EXAM 9 129 SHELLED CT 152A RAD. TECH WORK AREA 152 EX MRI CASSETTE 151 ELECT. 150 RECEIVING / MORGUE 149 READING RM 148 SHELL REHAB 146 ULTRASOUND 145 NEURO SHELL SPACE 144 ENDOSCOPY 143AINTERNAL MEDICINE 143 CORRIDOR X150 RR 140T VESTIBULE 100 CORRIDOR X130 CORRIDOR X120 CORRIDOR X110 CORRIDOR X140 STAIR S100 RR EXIT EXITEXITEXITEXITFE FE FEFE FE FE 40'-0" 34" OPENING PROVIDED 32" MIN. OPENING REQUIRED EXIT ON GRADE 34" OPENING PROVIDED 32" MIN. OPENING REQUIRED EXIT ON GRADE EXITEXITEXIT52'-0"48'-0"81'-0" 68" OPENING PROVIDED 32" MIN. OPENING REQUIRED EXIT ON GRADE CRCR CR 82'-0" 46" OPENING PROVIDED 32" MIN. OPENING REQUIRED EXIT ON GRADE 34" OPENING PROVIDED 32" MIN. OPENING REQUIRED EXIT ON GRADE PRIVATE WK RM 118B WORK RM 118A x2 Y Z NEW GENERATOR / ENCLOSURE PET RELIEF AREA ISOLATION PET RELIEF AREA FE MRI RECEPTION 102 © 2022 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 20297 FIRST FLOOR LIFE SAFETY PLAN 04 MARCH 2022 A0.50MEDVET INDIANAPOLIS - ANIMAL HOSPITAL9650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032RENOVATION AND ADDITION3/32" = 1'-0"A0.50 1 overall first floor life safety plan 07/13/22