HomeMy WebLinkAboutE001 ELECTRICAL NOTESSYMBOL DESCRIPTION SYMBOL DESCRIPTION SWITCH: SINGLE POLE 120V SMOKE DETECTOR WITH BATTERY BACKUP, INTERCONNECTED WITHIN AN APARTMENT UNIT SWITCH: THREE WAY 120V SMOKE DETECTOR WITH STROBE AND BATTERY BACKUP, INTERCONNECTED WITHIN AN APARTMENT UNIT SWITCH: FOUR WAY 120V STROBE ONLY, INTERCONNECTED WITH SMOKE DETECTORS WITHIN AN APARTMENT UNIT SWITCH: WALL OCCUPANCY SENSOR 120V C.O. DETECTOR WITH BATTERY BACKUP, INTERCONNECTED WITH SMOKE DETECTORS WITHIN AN APARTMENT UNIT SWITCH: OCCUPANCY SENSOR OVERRIDE SYSTEM FIRE ALARM: DETECTOR, X = TYPE S = SMOKE DETECTION, H = HEAT DETECTION, T = LOW TEMPERATURE DETECTION CEILING OCCUPANCY SENSOR SYSTEM FIRE ALARM: 520HZ HORN AND STROBE RECEPTACLE: 120V DUPLEX SYSTEM FIRE ALARM: 520 HZ HORN RECEPTACLE: 120V DUPLEX G.F.C.I. PROTECTED SYSTEM FIRE ALARM: FUTURE NOTIFICATION DEVICE PROVISION RECEPTACLE: 120V DUPLEX G.F.C.I. PROTECTED EXTERIOR RATED WITH WEATHERPROOF IN-USE COVER SYSTEM FIRE ALARM: HORN STROBE WP = WEATHERPROOF RECEPTACLE INSTALLED AT COUNTER HEIGHT (TYPICAL)SYSTEM FIRE ALARM: STROBE RECEPTACLE: DOUBLE DUPLEX (QUAD)SYSTEM FIRE ALARM: PULL STATION RECEPTACLE: DUPLEX FLOOR BOX WITH TV AND DATA, (1) RG-6 AND (1) CAT6 SYSTEM FIRE ALARM: TAMPER SWITCH MONITOR MODULE RECEPTACLE: DUPLEX LOWER HALF SWITCHED SYSTEM FIRE ALARM: FLOW SWITCH MONITOR MODULE D = RECEPTACLE: SINGLE DEDICATED CIRCUIT DM = RECEPTACLE: SINGLE DEDICATED CIRCUIT FOR MICROWAVE. LOCATE IN UPPER CABINET. SYSTEM FIRE ALARM: CONTROL RELAY RECEPTACLE: 120/208-240V 4-WIRE 50 = 50 AMP RATED 30 = 30 AMP RATED SYSTEM FIRE ALARM: FIRE ALARM CONTROL PANEL SERVICE DISCONNECT: NON-FUSED SYSTEM FIRE ALARM: ANNUNCIATOR PANEL SERVICE DISCONNECT: FUSED SYSTEM FIRE ALARM: NAC PANEL JUNCTION: JUNCTION LOCATED IN EQUIPMENT OR INSTALL JUNCTION BOX WITH COVER (WHERE APPLICABLE).ELECTRICAL PANELBOARD LOW VOLTAGE PANEL WITH 120V DUPLEX RECEPTACLE, (1) RG-6 AND (1) CAT6 TO TELECOM SERVICE ROOM. CEILING MOUNT LIGHT FIXTURE X = TYPE ELECTRICAL LOAD CENTER.WALL MOUNT LIGHT FIXTURE X = TYPE SECURITY CAMERA: TYPE IP TYPE: RM - REMOTE EMERGENCY EGRESS LIGHT TV AND DATA, (1) RG-6 AND (1) CAT6 TO LOW VOLTAGE PANEL WITHIN APARTMENT UNIT. TYPE: EXIT/EM - EXIT AND EMERGENCY LIGHT SHADED AREAS INDICATED ORIENTATION OF SIGN FACES ARROWS, IF PRESENT, INDICATE EGRESS DIRECTION DATA, (1) CAT6 TO NEAREST IT ROOM TYPE: EM - EMERGENCY LIGHT TV, (1) RG-6 TO NEAREST IT ROOM ACCESS CONTROL: CALL BOX DATA IN CEILING, (1) CAT6 TO NEAREST IT ROOM FOR FUTURE WIRELESS ACCESS POINT.ACCESS CONTROL: CARD READER PHOTOCELL 1 3 4 OS G WP/G HS H X HS S s V F TS FS FACP ANN HS WP 50 30 CR X X HP-XX s CB PC R NAC s VO WAP DM D OS J c X s R TYPE MANUFACTURER AND MODEL NUMBER LAMP TYPE MOUNTING DESCRIPTION A RAB: DSK34-6R16930120WS LED SURFACE UNIT CLOSET / LAUNDRY AREA B SEA GULL / GENERATION LIGHTING: 89181EN3-71 LED WALL SMALL COACH NOT LESS THAN 80" TO BOTTOM C RAB: DSK34-6R16930120WS LED SURFACE COMMON AREA D KUZCO: 492208-BK LED PENDANT UNIT KITCHEN BAR E KICHLER: 55092BK LED WALL UNIT BATHROOM VANITY EF-1 PROVIDED AND INSTALLED BY M.C., WIRING AND CONNECTION BY E.C.X RECESSED UNIT BATHROOM EXHAUST FAN G RAB: DSK34-6R16930120WS LED SURFACE UNIT BATHROOM H RAB: DSK34-6R16930120WS LED SURFACE UNIT KITCHEN / HALLWAY / ENTRY J KICHLER: 330171SBK LED PENDANT UNIT CEILING FAN AND LIGHT K SEA GULL / GENERATION LIGHTING: 89193DEN3-71 LED WALL LARGE COACH NOT LESS THAN 80" TO BOTTOM L RAB: DSK34-6R16930120WS LED SURFACE UNIT DINING AREA M EPCO: 16531 LED SURFACE GARAGE N ETI: VT-4-70-850-MV-D LED WALL / SURFACE ELEVATOR SHAFT P SEA GULL / GENERATION LIGHTING: 89181EN3-71 LED WALL SMALL COACH NOT LESS THAN 80" TO BOTTOM SL1 RAB: FFLED26N LED YARD POST SITE SL3 CBMC LIGHTING SOLUTIONS: DL147942 FIXTURE - DL147941 POLE LED POLE SITE SL5 CBMC LIGHTING SOLUTIONS: DL147942 FIXTURE - DL147941 POLE LED POLE SITE EM EXITRONIX: LED-90 LED WALL EMERGENCY EXIT/EM EXITRONIX: CLED-U-WH LED WALL / CEILING EXIT SIGN WITH EMERGENCY RM EXITRONIX: MLED2-G-WP LED WALL / CEILING REMOTE EGRESS RATING OR SETTING OF AUTOMATIC OVERCURRENT DEVICE IN (AMPERES) MINIMUM SIZE (AWG OR KCMIL) COPPER MINIMUM SIZE (AWG OR KCMIL) ALUMINUM OR COPPER-CLAD ALUMINUM 15 14 X 20 12 X 25 10 X 30 10 X 40 8 X 50 6 X 125 1 2/0 150 1/0 3/0 200 3/0 250 225 4/0 300 NOTE: SIZE ALL CONDUCTORS BASED ON ALL N.E.C. REQUIREMENTS INCLUDING THOSE FOR VOLTAGE DROP, ADJUSTMENTS AND CORRECTIONS. CEILING-MOUNTED DETECTOR WALL-MOUNTED DETECTOR GENERAL NOTES: 1. MOUNTING HEIGHTS SHOWN IN THIS DETAIL ARE TYPICAL UNLESS OTHERWISE NOTED ON THE PLANS. 2. SEE ARCHITECTURAL ELEVATIONS FOR SPECIAL CONDITIONS. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICTS. 3. ALL INSTALLATIONS SHALL COMPLY WITH ADA. VISUAL FIRE ALARM NOTIFICATION DEVICES (STROBE) LOCATE DEVICE SO THE BOTTOM OF THE DEVICE IS BETWEEN 80" AND 96" A.F.F. (NFPA) OR 6" BELOW CEILING, WHICHEVER IS LOWER (ADA). AUDIBLE FIRE ALARM NOTIFICATION DEVICES (HORN)LOCATE DEVICE SO THAT THE TOP OF UNIT IS NOT MORE THAN 90" A.F.F. AND NOT LESS THAN 6" BELOW CEILING (NFPA) POWER/COMMUNICATION DEVICES: OUTLETS SHALL BE LOCATED NOT LESS THAN 16" A.F.F. TO THE BOTTOM OF THE BOX. ABOVE COUNTER DEVICES SHALL BE LOCATED AT 2" ABOVE THE BACKSPLASH OF THE COUNTER TO THE BOTTOM OF THE DEVICES. VERIFY WITH ARCHITECTURAL DETAILS. IN ALL FHA/TYPE B UNITS, WALL-MOUNTED OPERABLE DEVICES: OPERABLE DEVICES SHALL BE LOCATED NOT MORE THAN 48" A.F.F. TO THE TOP OF THE OPERABLE PORTION OF THE DEVICE. WALL-MOUNTED OPERABLE DEVICES INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: LIGHT SWITCHES, DIMMERS, CONTROLS, ETC. PUSH BUTTONS INTERIOR AND EXTERIOR POWER AND COMMUNICATION HORN/STROBESTROBE FINISH FLOOR 16" 40" 48" 80" FINISH CEILING 88" DO NOT PLACE DETECTOR IN THIS AREA 12" MAX. 4" 4" 96" HORN CEILING-MOUNTED HORN OR HORN/STROBE 54" FIRE ALARM ACTIVATION DEVICES (PULL STATION)LOCATE FRONT-APPROACH DEVICES SO THAT THE HIGHEST OPERABLE PORTION OF THE DEVICE IS NOT MORE THAN 48" A.F.F (ADA) AND NOT LESS THAN 42" A.F.F. (NFPA). OUTLETS GARAGE DOOR OPENER BUTTON UNIT LOAD CENTER 44" ABOVE COUNTER DEVICES. COORDINATE WITH ARCH. ELEVATIONS AND CABINETRY SHOP DRAWINGS. MAXIMUM HEIGHT FOR WALL-MOUNTED OPERABLE DEVICES PULL STATION LOCATE ABOVE COUNTERTOP OUTLETS 12" MINIMUM FROM A PERPENDICULAR WALL, REFRIGERATOR OR OTHEROBSTRUCTION. 1. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS AND ONE-YEAR GUARANTEE COMMENCING ON DATE OF PROJECT ACCEPTANCE. 2. VERIFY LOCAL CONDITIONS AT SITE. 3. COMPLY WITH ALL APPLICABLE CODES. 4. SECURE AND PAY FOR ALL REQUIRED PERMITS AND SUPPLY TO G.C. PRIOR TO STARTING OF WORK. 5. ALL BRANCH CIRCUITS TO BE COPPER. BRANCH WIRING TO BE TYPE N.M. 6. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. PROVIDE AND INSTALL ENGRAVED LABELS WITH UNIT NUMBERS ON ALL A/C DISCONNECTS AND ELECTRICAL METERS. PROVIDE AND INSTALL TYPE WRITTEN PANEL DIRECTORY. 7. CONNECT TELEPHONE AND TELEVISION SYSTEMS PER LOCAL UTILITY REQUIREMENTS. VERIFY LOCATIONS AND TYPE OF EQUIPMENT REQUIRED WITH ARCHITECT AND OWNER. 8. PROVIDE AND INSTALL FIRE ALARM SYSTEM COMPLETE WITH CELL DIALER. ENGINEERED FIRE ALARM DRAWINGS TO BE SUBMITTED TO THE STATE AFTER AWARD OF PROJECT. 9. ALL ELECTRICAL DEVICES AND COVER PLATES TO BE WHITE WHERE APPLICABLE. MOUNTING HEIGHTS SCALE: N.T.S. ELECTRICAL SYMBOLS LIGHTING SCHEDULE CONDUCTOR SIZES GENERAL ELECTRICAL NOTES E001 ELECTRICAL NOTES, SCHEDULES AND SYMBOLS LEGEND E100 SITE - ELECTRICAL PLAN E101 BUILDING TYPE 2 - 1ST AND 2ND FLOOR ELECTRICAL PLANS E102 BUILDING TYPE 2 - 3RD AND 4TH FLOOR ELECTRICAL PLANS E103 BUILDING TYPE 3 - 1ST AND 2ND FLOOR ELECTRICAL PLANS E104 BUILDING TYPE 3 - 3RD AND 4TH FLOOR ELECTRICAL PLANS E201 UNIT TYPES U2, U3, D1 AND D1A - ELECTRICAL PLANS E202 UNIT TYPES D2, D3, D3A AND D4 - ELECTRICAL PLANS E203 UNIT TYPES D5, D6 AND T1 - ELECTRICAL PLANS E601 METER CENTER DETAILS AND PANEL SCHEDULES E602 ELECTRICAL LOAD CALCULATIONS DRAWING INDEX NOT ALL SYMBOLS MAY BE USED FOR THIS PROJECT. E001 SHEET NO. REVISIONS DATE: LAKESIDE APARTMENTS - PHASE 2CARMEL, INDIANA03.04.20215345 LEXINGTON AVEINDIANAPOLIS, IN 46219317-782-10081 ELECTRICAL NOTES, SCHEDULES AND SYMBOLS LEGEND07/26/22