HomeMy WebLinkAboutLS101 TYPE 2 1ST 2ND FLOOR LIFE SAFETYHSHS11. REFER TO THE STRUCTURAL FRAMING PLANS FOR LOCATIONS OF SHEAR WALLS IN THE FLOOR BOXES. 12. PROVIDE PORTABLE FIRE EXTINGUISHERS AND ADA-COMPLIANT SEMI-RECESSED FIRE EXTINGUISHER CABINETS (F.E.C.) WHERE INDICATED. 6. WALLS SURROUNDING EXIT ENCLOSURES ARE CLASSIFIED AS FIRE BARRIERS AND MUST MEET REQUIREMENTS PER SECTION 707 OF THE I.B.C. (SEE STAIR SECTIONS FOR ADDITIONAL INFORMATION). APPLICABLE BUILDING CODE: 2014 INDIANA BUILDING CODE. FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS SHALL BE EQUAL TO J.L. INDUSTRIES "AMBASSADOR" 1017F17 STEEL NON-RATED, SEMI-RECESS CABINET; "AMBASSADOR "1013F17 STEEL NON-RATED, SURFACE MOUNTED CABINETS WHERE INDICATED ON DRAWINGS; AND "COSMIC" #10E MULTI-PURPOSE DRY CHEMICAL EXTINGUISHERS. PROVIDE EXTINGUISHER SIZE AS REQUIRED INSIDE ELEVATOR EQUIPMENT ROOMS. PROVIDE CABINETS THAT COMPLY WITH ADA REQUIREMENTS. 13. PRIVATE GARAGE CEILINGS SHALL CONSIST OF (1) LAYER OF 5/8" F.C. GYPSUM BOARD APPLIED DIRECTLY TO THE UNDERSIDE OF THE FLOOR TRUSSES ABOVE, FOLLOWED BY (1) ADDITIONAL LAYER OF 1/2" GYPSUM BOARD FACING THE GARAGE SPACE. STAGGER ALL JOINTS BETWEEN GYP. BD. LAYERS. 14. SPRINKLER PIPING INSTALLER SHALL NOT LOCATE WET PIPE SPRINKLER PIPING INSIDE THE ROOF/ATTIC CAVITY. FIRE PROTECTION CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO START OF CONSTRUCTION. 2. THE CONTRACTOR, SUB-CONTRACTORS AND MATERIAL SUPPLIERS SHALL REVIEW AND BECOME FAMILIAR WITH DESIGNATED FIRE-RESISTIVE REQUIREMENTS OF UNDERWRITERS LABORATORIES (U.L.) ASSEMBLY DESIGNS AS PERTAINING TO THE PROJECT DESIGN. 3. THE CONTRACTOR, SUB-CONTRACTORS AND GYPSUM BOARD SUPPLIER SHALL REVIEW AND BECOME FAMILIAR WITH APPLICABLE SECTIONS OF THE CURRENT EDITION OF THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL. 4. REFER TO THE LIFE SAFETY WALL SECTIONS FOR LISTED FIRE RATED WALL, FLOOR/CEILING AND ROOF ASSEMBLIES. 5. PENETRATIONS INTO AND OPENINGS THROUGH EXIT ENCLOSURES (STAIRWELLS) ARE PROHIBITED BY CODE EXCEPT FOR ELECTRICAL CONDUIT AND SPRINKLER PIPING SERVING THE EXIT ENCLOSURE AREA. LIFE SAFETY NOTES: 1. FOR BASIC BUILDING CODE DATA PERTAINING TO THIS PROJECT, REFER TO THE "CODE INFORMATION" SECTION ON THE COVER SHEET. 10. REFER TO THE BUILDING ELEVATION DRAWINGS FOR LOCATIONS OF FIRE DEPARTMENT KEY ACCESS KNOX BOXES AT BUILDING ENTRANCES AND AT ENTRY DOORS TO BUILDING SPRINKLER CLOSETS. 7. ALL AREA AND DWELLING UNIT SEPARATION WALLS (FIRE PARTITIONS) AND THEIR POINTS OF INTERSECTION WITH OTHER WALLS SHALL INCLUDE CONTINUOUS (FULL-HEIGHT) WOOD BLOCKING TO SUPPORT GYPSUM DRYWALL. 8. REFER TO SHEET BA-101 FOR ASSIGNED BUILDING AND DWELLING UNIT STREET ADDRESSES. 9. THE GENERAL CONTRACTOR SHALL PROVIDE PERMANENT IDENTIFICATION SIGNAGE ABOVE THE CEILING LINE THAT IDENTIFIES A FIRE OR SMOKE BARRIER OR FIRE PARTITION SEPARATING DEFINED FIRE AREAS. THE SIGNAGE SHALL BE PLACED ADJACENT TO EACH STAIRWELL AND ABOVE PRIVATE GARAGE CEILINGS LOCATED ADJACENT TO A DWELLING UNIT. THE SIGNAGE SHALL BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR/CEILING OR ATTIC SPACES AS DEFINED BY THE INDIANA BUILDING CODE, SECTION 703.7. APPROVED DRAFTSTOP AT FLOOR BOX OR IN ATTIC SPACE AS APPROPRIATE AT THESE LOCATIONS. REFER TO THE LIFE SAFETY WALL SECTIONS FOR ADDITIONAL INFORMATION. THE CEILING ABOVE THIS AREA IS THE BOTTOM OF THE EXIT ENCLOSURE ABOVE AND MUST BE TREATED AS PART OF THE EXIT ENCLOSURE ASSEMBLY. PENETRATIONS INTO AND OPENINGS THROUGH EXIT ENCLOSURE ASSEMBLIES ARE PROHIBITED BY CODE EXCEPT FOR ELECTRICAL CONDUIT AND SPRINKLER PIPING SERVING THE EXIT ENCLOSURE AREA. LIFE SAFETY KEY: DRAFT STOPPING SHALL BE LOCATED ABOVE AND IN LINE WITH THE DWELLING UNIT SEPARATION WALLS AND AT CORRIDOR WALLS. CONSTRUCTION BELOW THE FLOOR LINE IN THIS SHADED AREA IS INCLUDED IN THE EXIT ENCLOSURE ON THE FLOOR BELOW AND MUST BE TREATED AS PART OF THE FIRE-RESISTIVE EXIT ENCLOSURE ASSEMBLY. PENETRATIONS INTO AND OPENINGS THROUGH EXIT ENCLOSURE ASSEMBLIES ARE PROHIBITED BY CODE EXCEPT FOR ELECTRICAL CONDUIT AND SPRINKLER PIPING SERVING THE EXIT ENCLOSURE AREA. WHERE INDICATED, SUBSTITUTE 1-HOUR FIRE RATED PLYWOOD SHEATHING OR EQUIVALENT IN LIEU OF STANDARD OSB SHEATHING AT PLANE OF EXTERIOR WALL. EXTERIOR WALL SHALL BE RATED FOR 1-HOUR F.R. CONSTRUCTION ON BOTH SIDES OF WALL FOR A MINIMUM DISTANCE OF 4 FEET IN EITHER DIRECTION (UNLESS OTHERWISE NOTED) OF A DESIGNATED FIRE WALL. REFER TO BUILDING ELEVATIONS FOR ADDITIONAL INFORMATION. F.W. "A" REFER TO LIFE SAFETY WALL SECTIONS AND DETAILS - REFER TO SHEETS A621 THRU A624. OCCUPANCY CLASSIFICATIONS PERTAINING TO SPRINKLER DESIGN, INSTALLATION AND WATER SUPPLY REQUIREMENTS AS DEFINED BY NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS ARE AS LISTED: RESIDENTIAL DWELLING UNITS: LIGHT HAZARD NFPA OCCUPANCY CLASSIFICATIONS: APPLICABLE BUILDING CODE: NFPA 13 AND NFPA 13-R DENOTES FIRE BARRIER AT WALL. PROVIDE FIRE-RATED CONSTRUCTION AS NOTED. REFER TO THE DOOR SCHEDULE FOR RATED OPENINGS. IN ACCORDANCE WITH THE 2014 INDIANA BUILDING CODE, TABLE 803.9 - INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY, PROVIDE INTERIOR FINISHES COMPLYING WITH THE FOLLOWING FLAME SPREAD INDEX FOR THE INTENDED USES: INTERIOR FINISH RATINGS: GROUP R-2 SPRINKLERED DWELLING UNITS: GROUP INTERIOR EXIT STAIRWAYS CORRIDORS ROOMS AND ENCLOSED SPACES C C C FLAME SPREAD INDEXES SHALL NOT EXCEED THE VALUES DESCRIBED ABOVE FOR THEIR DESIGNATED LOCATION. PENETRATIONS INTO AND OPENINGS THROUGH EXIT ENCLOSURE ASSEMBLIES ARE PROHIBITED BY CODE EXCEPT FOR ELECTRICAL CONDUIT AND SPRINKLER PIPING SERVING THE EXIT ENCLOSURE AREA. LS1 1. FIRE PROTECTION CONTRACTOR SHALL PROVIDE AN NFPA 13R AUTOMATIC SPRINKLER SYSTEM IN ALL GROUP R-2 OCCUPANCIES IN ACCORDANCE WITH I.B.C. SECTION 903.3.1.2. THE PRIVATE GARAGES (USE GROUP U) SHALL BE PROTECTED WITH AUTOMATIC SPRINKLERS HYDRAULICALLY CALCULATED PER NFPA 13. FIRE PROTECTION NOTES:architects and land planners6201 carrollton avenueIndianapolis, in 46220phone 317 202 0661fax 317 202 0662email office@weaversherman.comweaver sherman design07/26/22