HomeMy WebLinkAboutA209 UNITS T1UNIT PLAN NOTES: 12. CONTRACTOR OPTION: SUBSTITUTE GRANITE TOPS w/ INTEGRAL LAVATORY BOWLS AND MATCHING BACK SPLASHES IN LIEU OF LAMINATE PLASTIC TOPS WHERE INDICATED AT BATH AND POWDER ROOMS. 8. REFERENCE OVERALL BUILDING PLANS (COMPLEX PLANS) TO ESTABLISH RIGHT & LEFT HAND BATH ELEVATIONS. 9. REFER TO SHEET A252 FOR COMMON DOOR NOTES. 1. ALL DIMENSIONS AT WOOD STUD FRAMING ARE MEASURED TO FACE OF 2x WOOD STUDS UNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED. 2. WOOD BLOCKING FOR ANCHORAGE SHALL BE PROVIDED FOR ALL WINDOW CURTAIN RODS, SHOWER RODS, HANDRAIL BRACKETS, TOILET PAPER HOLDER AND SIMILAR ITEMS. REFER TO TYPICAL INTERIOR WALL ELEVATIONS ON THE UNIT PLAN SHEETS. 3. PROVIDE ADA-COMPLIANT TRANSITIONAL MOLDED RUBBER OR VINYL CARPET EDGING WHERE CARPET ADJOINS DIFFERENT FLOORING MATERIAL. 4. REFER TO SHEET A252 FOR DOOR, WINDOW AND GLAZING NOTES. 1. PRE-ROCK FIRE RATED AND LOAD-BEARING WALLS AROUND TUB & SHOWER UNITS. 2. AT TUB AND SHOWER LOCATIONS INSTALL 2x6 FRAME WALL AFTER THEY HAVE BEEN SET. 3. INSTALL CONCEALED FIRE BLOCKING IN WALL ABOVE TUB & SHOWER UNITS (ABOVE SHOWER HEAD) AT WET (CONTROLS) END WHEN TUB OR SHOWER PLUMBING IS LOCATED IN A FIRE-RATED WALL OR PARTITION. 4. ALL TUBS SHALL BE 42" GARDEN TUBS UNLESS OTHERWISE NOTED. 5. PROVIDE HVAC RETURN AIR GRILLE (R.A.G.) IN D.U. WALL WHERE INDICATED. ADJUST STUD SPACING TO ALLOW 18" CLEAR WIDTH BETWEEN STUDS AT RETURN AIR CHASE. REFER TO MECHANICAL DRAWINGS. 7. CONTRACTOR SHALL ENSURE THE LOCATION OF THE BATH TUB WATER CONTROL VALVE DOES NOT CONFLICT WITH THE REQUIRED LOCATION OF FUTURE GRAB BARS. GRAB BARS SHALL BE LOCATED ABOVE THE BATH TUB WATER CONTROL VALVE. 8. PROVIDE CONCEALED BLOCKING IN WALLS AT TUB AND SHOWER SURROUNDS FOR INSTALLATION OF FUTURE GRAB BARS AND SHOWER SEATS IN ALL (TYPE B) DWELLING UNITS. CONCEALED BLOCKING SUPPLIED BY TUB/SHOWER SURROUND MANUFACTURER SHALL INCLUDE INTEGRAL BLOCKING DIRECTLY APPLIED TO THE OUTER WALL OF TUB/SHOWER WALL SET. 9. ALL DWELLING UNIT BATHROOMS CLASSIFIED AS (TYPE B): - CENTER THE LAVATORY 2'-0" AS MEASURED FROM THE ADJACENT SIDE WALL DRYWALL. CENTER THE MIRROR AND BATH LIGHT FIXTURE ON THE CENTERLINE OF THE LAVATORY. ON SMALLER VANITIES, ALIGN THE EDGE OF THE MIRROR WITH THE END PANEL OF THE VANITY CABINET. 10. PLACE 18" TOWEL BAR (T.B.) CENTERED OVER TOILET. CONFIRM w/ OWNER FINAL LOCATION OF 24" TOWEL BAR (T.B.) AND ROBE HOOKS PRIOR TO PLACEMENT ON WALL. 11. A MATCHING END SPLASH IS REQUIRED FOR ALL BATH AND KITCHEN COUNTERTOPS ADJACENT TO WALLS. 5. REFERENCE OVERALL BUILDING PLANS (COMPLEX PLANS) TO ESTABLISH RIGHT & LEFT HAND BATH ELEVATIONS. 6. MOUNT BOTTOM OF GLAZING AT BATH MIRRORS +40" A.F.F. 6. DOORS, WINDOWS, FIXTURES, HARDWARE, CONTROLS AND EQUIPMENT IN ALL DWELLING UNITS ARE REQUIRED TO BE ACCESSIBLE AND SHALL MEET THE REQUIREMENTS OF CHAPTER 11 OF THE 2014 INDIANA BUILDING CODE. 7. CONTRACTOR OPTION: PROVIDE TEMP. GLASS SHOWER ENCLOSURE w/ DOOR AT SHOWERS IN LIEU OF SHOWER ROD. SHOWER DOORS SHALL BE SIZED TO PROVIDE A MIN. 32" CLEAR UNOBSTRUCTED WIDTH OF OPENING WHEN DOOR IS IN THE FULLY OPEN POSITION. SHOWER COMPARTMENT ENCLOSURES SHALL NOT OBSTRUCT SHOWER CONTROLS OR OBSTRUCT TRANSFER FROM WHEELCHAIRS ONTO SHOWER SEATS. 10. CONTRACTOR OPTION: SUBSTITUTE GRANITE TOPS AND MATCHING BACK SPLASHES IN LIEU OF LAMINATE PLASTIC TOPS WHERE INDICATED AT KITCHENS. BATH NOTES: SIGNAGE PLACEMENT PROVIDED BY OWNER. REFER TO SIGNAGE SCHEDULE ON SHT. A25100 DENOTES TEMPERED GLAZING ON DOOR OR WINDOW UNITS WHERE INDICATED. ALSO REFER TO THE WINDOW SCHEDULE ON THE BUILDING ELEVATIONS SHEETS DOOR TAG - REFER TO SHEET A2513-0 WINDOW TAG - REFER TO BUILDING ELEVATIONS (AND COMPLEX FLOOR PLANS WHERE INDICATED) FLOOR PLAN KEY: A REQUIRED CLEAR FLOOR SPACE WHERE INDICATED IN FLOOR PLAN PER IIC A117.1-2009, SECTION 305 5' DIA. (MIN.) M DWELLING UNIT MECHANICAL ROOM EQUIPMENT - REFER TO MPE DRAWINGS T GYPSUM BOARD BULKHEAD OR DROPPED CEILING WHERE INDICATED RETURN AIR GRILLE IN WALL - REFER TO MPE DRAWINGSR.A.G. AIR CONDITIONER - REFER TO MECHANICAL DRAWINGSAC 1. NO OBSTRUCTIONS ALLOWED WITHIN MANEURVERING CLEARANCE AREAS. 2. ALL DIMENSIONS INDICATED ARE (MINIMUM). 3. DIMENSIONS ARE MEASURED TO WALL FINISH. 30" 48"EXAMPLE: DOOR MANEUVERING CLEARANCES OF A 3'-0" SWINGING LATCHED DOOR 12" 1. NO OBSTRUCTIONS ALLOWED WITHIN MANEURVERING CLEARANCE AREAS. 2. ALL DIMENSIONS INDICATED ARE (MINIMUM). 3. DIMENSIONS ARE MEASURED TO WALL FINISH. 18" 48"48"60"54" EXAMPLE: DOOR MANEUVERING CLEARANCES OF A 3'-0" SWINGING LATCHED AND SELF-CLOSING DOOR48"30" APPROACH APPROACH APPROACHAPPROACH30"48" REQUIRED TURNING SPACE (CIRCULAR) WHERE INDICATED IN FLOOR PLAN PER IIC A117.1-2009, SECTION 304.3.1 REQUIRED TURNING SPACE (T-SHAPED) WHERE INDICATED IN FLOOR PLAN PER IIC A117.1-2009, SECTION 304.3.2. ALL DIMENSIONS INDICATED ARE (MINIMUM)36"60" 36" 12" 12"36"24"24"DOOR MANEUVERING CLEARANCES FOR SWINGING DOORS SHALL COMPLY w/ IIC A117.1-2009, SECTION 404.2.3.2 Accessibleroute DENOTES ACCESSIBLE ROUTE FROM BUILDING INTERIOR AS DEFINED BY ICC/ANSI A117.1-2009, SECTION 402. REFER TO CIVIL DRAWINGS FOR ACCESSIBLE ROUTES LOCATED OUTSIDE THE BUILDING SEMI-RECESSED FIRE EXTINGUISHER CABINET w/ PORTABLE FIRE EXTINGUISHER F.E.C. 11. ACCESSIBLE KITCHEN RANGE: OWNER SHALL ENSURE THAT THE ELECTRIC RANGE SELECTED AND INSTALLED IN ALL (TYPE B) UNITS HAS A DEPTH THAT WILL ALLOW THE RANGE TO BE INSTALLED WITH THE OUTER FRONT EDGE OF THE RANGE (NOT INCLUDING THE DOOR HANDLE) TO BE NO MORE THAN 25 1/2" FROM THE WALL BEHIND THE RANGE. 12. COUNTERTOP BACK SPLASHES LOCATED IN KITCHENS AND BATHROOMS SHALL NOT EXCEED 4" IN HEIGHT AS MEASURED FROM THE COUNTERTOP SURFACE TO THE TOP OF THE BACK SPLASH.architects and land planners6201 carrollton avenueIndianapolis, in 46220phone 317 202 0661fax 317 202 0662email office@weaversherman.comweaver sherman design07/26/22