HomeMy WebLinkAboutA303 ELEVATIONS TYPE 3A
WINDOW SCHEDULE- BLDG. TYPES 2 & 3
TYPE TEMPERED
GLAZINGSIZEDESCRIPTION REMARKS
REFER TO SHEET A251 FOR WINDOW AND GLAZING NOTES
C
D
E
F
------(2) 3'-0" x 6'-0"SINGLE HUNG EGRESS
SINGLE HUNG
(2) 3-0" x 5'-4"SINGLE HUNG
(2) 3'-0" x 2'-0"FIXED
T1
DOOR SIDELIGHT/TRANSOM SCHEDULE
TYPE TEMPERED
GLAZINGSIZEDESCRIPTION REMARKS
NOTES: 1. REFER TO SHEET A253 FOR DOOR SCHEDULE
2. SIDELIGHT GRIDS SHALL MATCH DOOR STYLE - REFER TO BUILDING ELEVATIONS
T2
T3
YES3'-0" x 1'-0"FIXED
EGRESS
DOOR
TRANSOM
B 3'-0" x 6'-0"SINGLE HUNG EGRESS
T4 YESFIXED DOOR
TRANSOM (2) 3'-0" x 1'-0"
2'-0" x 5'-0"SINGLE HUNG -----
------
WHERE
INDICATED
(2) 2'-6"x6'-0" w/
(1) 3'-0"x6'-0" @ CENTER
WHERE
INDICATED -----
-----
G 3'-0" x 2'-0"FIXED -----
H (2) 3'-0" x 3'-0"FIXED -----
I (OMIT)
J
K
L FIXED -----3'-0" x 3'-0"
WHERE
INDICATED
WHERE
INDICATED
------
------
------
(OMIT)
(OMIT)
-----------
-----------
-----------
------
------
------
(OMIT)
(OMIT)
EXTERIOR MATERIALS KEY:
QUEEN SIZE BRICK VENEER
BRICK ROWLOCK SILL OR SOLDIER COURSE HEADER
FIBER CEMENT BOARD SIDING PANEL (SMOOTH FINISH)
FIBER CEMENT PLANK SIDING w/ 6" EXPOSURE
PRE-FINISHED ALUMINUM GUTTERS
PRE-FIN. ALUMINUM FLASHING @ INTERSECTIONS w/ ROOF LINES.
OVERHEAD GARAGE DOOR (TYP. U.N.O.) - PROVIDE
LITES WHERE INDICATED
FIBERGLASS SCREENING AT PATIO OR DECK
1x TRIM PORCH COLUMN - PAINT, SIZE AS NOTED
PAINTED WOOD BRACKET - REFER TO DETAIL BK-1/A633
2x2 RAM HEAD TRIM OVER 1x8 SMOOTH HEAD TRIM
PAINTED GABLE VENT (NON FUNCTIONAL)
PAINTED 1x BATTEN TRIM w/ SEALANT BEHIND
GARAGE DOOR JAMB & HEAD TRIM - PAINT
PAINTED 1x TRIM (SMOOTH) - SIZE AS INDICATED
PAINTED 1x8 BASE TRIM (SMOOTH) w/ SLOPED 2x2 CAP
KNOX BOX - SURFACE MOUNT MODEL #3261 (BLACK FINISH) - LOCATE
CENTERLINE OF BOX @ +60" ABOVE FIN. GRADE
LIGHT FIXTURE (REFER TO ELECT. DWG'S.)
ELEC. METER BASE - SEE ELECT. DWG'S. & DTL. 2/A252
CONCEALED STEEL BRICK LINTEL - SEE SHEET A551
GUARDRAIL ASSEMBLY
FIBERGLASS ROOF SHINGLES - SEE NOTE #1 BELOW
DRYER VENT (REFER TO MECH. DWG'S.)
METAL FLASHING
PAINTED STEEL DOOR - REFER TO DOOR SCHEDULE
BUILT-OUT 2x COLUMN
PRE-FINISHED ALUMINUM FLASHED SCUPPER AT ROOF EDGE
1
2
3
4
5
12
6
7
8
9
10
11
18
13
14
15
21
16
17
19
20
22
23
24
25
26
NOTES:
1. ROOFING SHINGLES SHALL BE ARCHITECTURAL TAB DIMENSIONAL.
PROVIDE ICE AND WATER SHIELD AT ALL VALLEY LOCATIONS.
2. CONTINUOUS RIDGE VENTS SHALL BE EQUAL TO "SHINGLE VENT II".
3. PROVIDE PRE-FINISHED ALUMINUM GUTTERS AND DOWNSPOUTS,
COLORS AS SELECTED BY ARCHITECT.
4. PROVIDE SMOOTH FINISH SIDING PANELS AND TRIM U.N.O.
5. PATIO LIGHTING TYPICALLY IS NOT INDICATED ON THE BUILDING
ELEVATIONS. REFER TO THE ELECTRICAL DRAWINGS.
6. FURNISH & INSTALL PRE-FINISHED ALUMINUM Z-FLASHING AT FIBER
CEMENT PANEL SEAMS UNLESS NOTED OTHERWISE.
7. BATHROOM & CLOTHES DRYER EXHAUST VENT OUTLETS SHALL BE
LOCATED ON EXTERIOR WALLS AND BE PLACED NO CLOSER THAN
3 FEET FROM ANY DOOR OR WINDOW OPENING.
8. PROVIDE 2x6 INTERMEDIATE HEADER w/ EXTERIOR TRIM BETWEEN
WINDOWS AND TRANSOMS WHERE INDICATED.
9. PROVIDE WINDOW AND TRANSOM GRIDS WHERE INDICATED ON
BUILDING ELEVATIONS.
10. REFER TO SHEET A251 FOR WINDOW AND GLAZING NOTES.
11. DECKS AND PATIOS IDENTIFIED TO BE SCREENED SHALL INCLUDE A
MANUFACTURED ALUMINUM SCREEN SYSTEM EQUAL TO SCREENEZE.
27
12. EXTERIOR ENTRY AND DWELLING UNIT PATIO AND DECK LIGHT
FIXTURES - PROVIDE MIN. +80" CLEARANCE BETWEEN BOTTOM OF LIGHT
FIXTURE AND FINISH FLOOR ELEVATION TO MEET ACCESSIBILITY
REQUIREMENTS.
DENOTES TEMPERED GLAZING ON DOOR OR WINDOW UNITS
WHERE INDICATED. ALSO REFER TO THE WINDOW
SCHEDULE ON THE BUILDING ELEVATIONS SHEETS
BUILDING ELEVATIONS KEY:
WINDOW TAG - REFER TO WINDOW SCHEDULE ON BUILDING
ELEVATION SHEETS (AND COMPLEX FLOOR PLANS WHERE
INDICATED)
A
T
DENOTES DRYER VENT ON WALL. ALIGN OR GROUP
MULTIPLE VENTS - REFER TO MECHANICAL DWG'S.
DENOTES RIDGE VENT architects and land planners6201 carrollton avenueIndianapolis, in 46220phone 317 202 0661fax 317 202 0662email office@weaversherman.comweaver sherman design07/26/22