Loading...
HomeMy WebLinkAboutA303 ELEVATIONS TYPE 3A WINDOW SCHEDULE- BLDG. TYPES 2 & 3 TYPE TEMPERED GLAZINGSIZEDESCRIPTION REMARKS REFER TO SHEET A251 FOR WINDOW AND GLAZING NOTES C D E F ------(2) 3'-0" x 6'-0"SINGLE HUNG EGRESS SINGLE HUNG (2) 3-0" x 5'-4"SINGLE HUNG (2) 3'-0" x 2'-0"FIXED T1 DOOR SIDELIGHT/TRANSOM SCHEDULE TYPE TEMPERED GLAZINGSIZEDESCRIPTION REMARKS NOTES: 1. REFER TO SHEET A253 FOR DOOR SCHEDULE 2. SIDELIGHT GRIDS SHALL MATCH DOOR STYLE - REFER TO BUILDING ELEVATIONS T2 T3 YES3'-0" x 1'-0"FIXED EGRESS DOOR TRANSOM B 3'-0" x 6'-0"SINGLE HUNG EGRESS T4 YESFIXED DOOR TRANSOM (2) 3'-0" x 1'-0" 2'-0" x 5'-0"SINGLE HUNG ----- ------ WHERE INDICATED (2) 2'-6"x6'-0" w/ (1) 3'-0"x6'-0" @ CENTER WHERE INDICATED ----- ----- G 3'-0" x 2'-0"FIXED ----- H (2) 3'-0" x 3'-0"FIXED ----- I (OMIT) J K L FIXED -----3'-0" x 3'-0" WHERE INDICATED WHERE INDICATED ------ ------ ------ (OMIT) (OMIT) ----------- ----------- ----------- ------ ------ ------ (OMIT) (OMIT) EXTERIOR MATERIALS KEY: QUEEN SIZE BRICK VENEER BRICK ROWLOCK SILL OR SOLDIER COURSE HEADER FIBER CEMENT BOARD SIDING PANEL (SMOOTH FINISH) FIBER CEMENT PLANK SIDING w/ 6" EXPOSURE PRE-FINISHED ALUMINUM GUTTERS PRE-FIN. ALUMINUM FLASHING @ INTERSECTIONS w/ ROOF LINES. OVERHEAD GARAGE DOOR (TYP. U.N.O.) - PROVIDE LITES WHERE INDICATED FIBERGLASS SCREENING AT PATIO OR DECK 1x TRIM PORCH COLUMN - PAINT, SIZE AS NOTED PAINTED WOOD BRACKET - REFER TO DETAIL BK-1/A633 2x2 RAM HEAD TRIM OVER 1x8 SMOOTH HEAD TRIM PAINTED GABLE VENT (NON FUNCTIONAL) PAINTED 1x BATTEN TRIM w/ SEALANT BEHIND GARAGE DOOR JAMB & HEAD TRIM - PAINT PAINTED 1x TRIM (SMOOTH) - SIZE AS INDICATED PAINTED 1x8 BASE TRIM (SMOOTH) w/ SLOPED 2x2 CAP KNOX BOX - SURFACE MOUNT MODEL #3261 (BLACK FINISH) - LOCATE CENTERLINE OF BOX @ +60" ABOVE FIN. GRADE LIGHT FIXTURE (REFER TO ELECT. DWG'S.) ELEC. METER BASE - SEE ELECT. DWG'S. & DTL. 2/A252 CONCEALED STEEL BRICK LINTEL - SEE SHEET A551 GUARDRAIL ASSEMBLY FIBERGLASS ROOF SHINGLES - SEE NOTE #1 BELOW DRYER VENT (REFER TO MECH. DWG'S.) METAL FLASHING PAINTED STEEL DOOR - REFER TO DOOR SCHEDULE BUILT-OUT 2x COLUMN PRE-FINISHED ALUMINUM FLASHED SCUPPER AT ROOF EDGE 1 2 3 4 5 12 6 7 8 9 10 11 18 13 14 15 21 16 17 19 20 22 23 24 25 26 NOTES: 1. ROOFING SHINGLES SHALL BE ARCHITECTURAL TAB DIMENSIONAL. PROVIDE ICE AND WATER SHIELD AT ALL VALLEY LOCATIONS. 2. CONTINUOUS RIDGE VENTS SHALL BE EQUAL TO "SHINGLE VENT II". 3. PROVIDE PRE-FINISHED ALUMINUM GUTTERS AND DOWNSPOUTS, COLORS AS SELECTED BY ARCHITECT. 4. PROVIDE SMOOTH FINISH SIDING PANELS AND TRIM U.N.O. 5. PATIO LIGHTING TYPICALLY IS NOT INDICATED ON THE BUILDING ELEVATIONS. REFER TO THE ELECTRICAL DRAWINGS. 6. FURNISH & INSTALL PRE-FINISHED ALUMINUM Z-FLASHING AT FIBER CEMENT PANEL SEAMS UNLESS NOTED OTHERWISE. 7. BATHROOM & CLOTHES DRYER EXHAUST VENT OUTLETS SHALL BE LOCATED ON EXTERIOR WALLS AND BE PLACED NO CLOSER THAN 3 FEET FROM ANY DOOR OR WINDOW OPENING. 8. PROVIDE 2x6 INTERMEDIATE HEADER w/ EXTERIOR TRIM BETWEEN WINDOWS AND TRANSOMS WHERE INDICATED. 9. PROVIDE WINDOW AND TRANSOM GRIDS WHERE INDICATED ON BUILDING ELEVATIONS. 10. REFER TO SHEET A251 FOR WINDOW AND GLAZING NOTES. 11. DECKS AND PATIOS IDENTIFIED TO BE SCREENED SHALL INCLUDE A MANUFACTURED ALUMINUM SCREEN SYSTEM EQUAL TO SCREENEZE. 27 12. EXTERIOR ENTRY AND DWELLING UNIT PATIO AND DECK LIGHT FIXTURES - PROVIDE MIN. +80" CLEARANCE BETWEEN BOTTOM OF LIGHT FIXTURE AND FINISH FLOOR ELEVATION TO MEET ACCESSIBILITY REQUIREMENTS. DENOTES TEMPERED GLAZING ON DOOR OR WINDOW UNITS WHERE INDICATED. ALSO REFER TO THE WINDOW SCHEDULE ON THE BUILDING ELEVATIONS SHEETS BUILDING ELEVATIONS KEY: WINDOW TAG - REFER TO WINDOW SCHEDULE ON BUILDING ELEVATION SHEETS (AND COMPLEX FLOOR PLANS WHERE INDICATED) A T DENOTES DRYER VENT ON WALL. ALIGN OR GROUP MULTIPLE VENTS - REFER TO MECHANICAL DWG'S. DENOTES RIDGE VENT architects and land planners6201 carrollton avenueIndianapolis, in 46220phone 317 202 0661fax 317 202 0662email office@weaversherman.comweaver sherman design07/26/22