HomeMy WebLinkAboutA404 ELEVATOR SECTIONSFURNISH AND INSTALL (2) IDENTICAL PASSENGER ELEVATORS EQUAL TO "ENDURA" MRL SERIES AS
MANUFACTURED BY THYSSEN KRUPP ELEVATOR COMPANY
ELEVATOR PERFORMANCE SPECIFICATIONS
SIDEWALL PANELS:PLASTIC LAMINATE,
"STANDARD" SELECTION
WALL PANEL REVEALS: #4 STAINLESS STEEL
HANDRAILS: CYLINDRICAL, 1 1/2" DIA.,
SATIN STAINLESS STEEL
SUSPENDED CEILING: METAL PAN, #4 STAINLESS
STEEL, BRUSHED FINISH
LIGHTING:RECESSED LED
DOWNLIGHTS
DOORS & FRAMES:#4 STAINLESS STEEL
FINISH FLOORING:CARPET BY OWNER
PERFORMANCE SPECIFICATIONSCAPACITY:3,500 LBS.
TYPE:A:HYDRAULIC
SPEED:150 FPM UP/DOWN
NUMBER OF STOPS:4
FLOOR STOPS:LEVELS 1, 2, 3, 4
NET TRAVEL:32'-1 1/8"
OVERHEAD CLEARANCE:12'-11" MIN.
HOISTWAY CEILING:13'-9"
CAR HEIGHT:7'-4" CLEAR
HOISTWAY SIZE:8'-8" x 6'-11"
INSIDE DIM. CAB SIZE:6'-8" x 5'-5"
DOOR POSITION:SIDE OPENING - LEFT
DOOR ENTRANCE WIDTH:3'-6"
DOOR ENTRANCE HEIGHT:7'-0"
EMERGENCY POWER:BATTERY LOWERING
PADS AND HOOKS: YES
PIT DEPTH: 4'-0"
SIGNALIZATION FIXTURE: STANDARD
BUILDING VOLTAGE: 208V. 3 PHASE, 60 HZ.
HOISTWAY CONSTRUCTION: REINFORCED CMU
MACHINE ROOM: NOT REQUIRED
CONTROLLER: LOCATED IN DOOR
JAMB ON LEVEL 2
FIRE SERVICE ACCESS REQUIRED
ELEVATOR (FSAE) -
ACCOMMODATE 24"x84"
STRETCHER
*
*DENOTES DIMENSIONING TO UNDERSIDE OF 8" WF HOIST BEAM