HomeMy WebLinkAboutM300 ENLARGED MECHANICAL PLANSM REF'GD.W. 50C 210A 210A210A 16B 210B26M 30C 30F30F 210B210BM REF'GD.W. T LV-1 LV-2 4"ø EAEF-1 EF-1 4x10x4 30 CFM ø 7" ø8" ø7" ø4" 6x10x6 80 CFM 30"x12" H.S.W R.A.G 6x14x8 180 CFM 6x12x7 140 CFM 6x12x7 140 CFM 16"x10" SADB-1 AH-16"ø EAø4"ø 4 " 14"x6" T.A.G 4x10x4 30 CFM ø6"ø4"4"ø EA16"x10" SAAH-1 EF-1 LV-1 4x10x4 30 CFM DB-1 EF-1 4x10x4 30 CFM ø7"ø7" ø7" LV-1 6x12x7 120 CFM 6x12x7 120 CFM 6x12x7 120 CFM 6x12x7 120 CFM T ø7" ø4" ø4" 30"x12" H.S.W R.A.G LV-1 4"ø EA4"ø EA4x10x4 30 CFM 14"x6" T.A.G ø4" ø4" 4x10x4 30 CFM MOORE ENGINEERING SERVICES, INC. 6340 LaPas Trail Indianapolis, IN 46268 Phone (317) 291-1052 FAX (317) 298-2729 T R NNDIA A STATE OF DERI G EEIS PE60860351 No.REENIGNELANOISSEFORPDOUGLAS.R MOO RESHEET NO.architects and land planners6201 carrollton avenueIndianapolis, in 46220phone 317 202 0661fax 317 202 0662email office@weaversherman.comweaver sherman designREVISIONS DATE: M300 Enlarged Mechanical PlansLAKESIDE APARTMENTS - PHASE 2 03/04/2021 3/8" = 1'-0"1 Unit D1 & D1A Mech 3/8" = 1'-0"3 Unit D2 Mech No.Date 07/26/22