HomeMy WebLinkAboutA1.01 FIRST FLOOR PLAN1 A2.01 2 A2.01 A3.01 4 19' - 3"1 A2.02 5' - 2 1/2" GREAT ROOM CLOSET EDGE OF ROOF EAVE MATCH EXIST. 4" CONCRETE SLAB ON GRADE W/ FIBER REINFORCING OVER 6" COMPACTED GRANULAR FILL 2'-6" x 2'-6" FOOTER W/ #5 REINF. W4 W2 W4 W3 W3 27' - 3"4' - 4 1/4" 3 A2.02 PATIO D.S. D.S. D.S. D.S. JOB NO.: DATE: DRAWING TITLE: ISSUE: STAMP: Project Status 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM A1.01 FIRST FLOOR - PROPOSED PLAN Project Number111 BENNET ROAD ADDITIONOwnerOctober 20, 2021111 BENNET ROAD, CARMEL, IN 46032Project NumberProject Status 1/4" = 1'-0"1 First Floor - Proposed PLAN GENERAL NOTES A. REFER TO LIFE SAFETY AND PARTITIONS FOR LOCATION OF RATED PARTITIONS, SEPARATION INFORMATION, AND PARTITION TYPES. ALL INTERIOR PARTITIONS ARE TYPE 1 UNLESS OTHERWISE NOTED OR SHOWN. B. ALL DIMENSIONS ARE TO FACE OF STUD, CMU AND/OR CONCRETE UNLESS NOTED OTHERWISE. C. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. D. ALL NEW WORK SHALL BE PLUMB TRUE, AND LEVEL UNLESS OTHERWISE NOTED. E. EXTEND FIRE RESISTANT CONSTRUCTION TO STRUCTURE ABOVE. EXTEND PARTITIONS AROUND EQUIPMENT, CABINETS, AND OTHER ITEMS THAT PENETRATE THESE PARTITIONS AND FILL VOIDS IN PARTITIONS ABOVE CEILING TO MAINTAIN DESIGNATED FIRE RESISTANCE. SEE LIFE SAFETY SHEET(S) FOR FURTHER FIRE AND SMOKE RESISTANCE INFORMATION. F. DISSIMILAR FLOOR MATERIALS SHALL MEET UNDER CENTER OF DOOR LEAF G. REFER TO STRUCTURAL DRAWINGS FOR FRAMING INFORMATION AND FRAMING DIMENSIONS. H. ALL APPLIANCES ARE TO BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR, UNLESS OTHERWISE NOTED OR SHOWN. I. VERIFY ALL APPLIANCE DIMENSIONS PRIOR TO FINAL MILLWORK CONSTRUCTION. # DATE DESCRIPTION 07/27/22