HomeMy WebLinkAboutA1.10 PROPOSED ROOF PLAN-
A3.01
-
3 A3.011
1
A2.01
2
A2.01
A3.01
4
1
A2.02
R1
R2
R3
R4
SLOPE SLOPE
R2
R2
R3
R4
R4
R4
R2
R3
R3
R3
JOB NO.:
DATE:
DRAWING TITLE:
ISSUE:
STAMP:
Project Status
6015 ORCHARD HILL LANE
P: 317.520.2558
INDIANAPOLIS, IN 46220
WWW.ARXTHEON.COM
A1.10
ROOF - PROPOSED PLAN
Project Number111 BENNET ROAD ADDITIONOwnerOctober 20, 2021111 BENNET ROAD, CARMEL, IN 46032Project NumberProject Status
1/4" = 1'-0"1 Roof Proposed Plan
ROOF PLAN GENERAL NOTES
A. ROOF SURFACES TO SLOPE AT A MINIMUM 1/4" PER FOOT UNLESS
OTHERWISE NOTED OR SHOWN. PROVIDE TAPERED INSULATION WHERE
INDICATED OR REQUIRED TO PROVIDE POSITIVE DRAINAGE TO ROOF
DRAINS AT A MINIMUM 1/4" PER FOOT. TAPERED INSULATION LAYOUT AS
SHOWN IS TO COMMUNICATE GENERAL DRAIN STRATEGY - ACTUAL AMOUNT
MAY VARY.
B. ROOF AREAS MUST HAVE POSITIVE DRAINAGE UNLESS SHOWN OTHERWISE.
NO PONDING OF WATER OVER 1/8" IN DEPTH WILL BE ACCEPTABLE AT ROOF
DRAINS.
C. COORDINATE ROOF DRAIN/SCUPPER LOCATIONS WITH PLUMBING
DRAWING(S).
D. COORDINATE ROOF PENETRATION REQUIREMENTS, INCLUDING THOSE THAT
MAY NOT BE SHOWN, WITH ROOFING CONTRACTOR, AND MECHANICAL,
ELECTRICAL, AND PLUMBING DRAWINGS.
E. ROOF PENETRATIONS SHALL BE IN COMPLIANCE WITH MANUFACTURER AND
NRCA REQUIREMENTS.
F. ROOFING COMPONENTS MAY VARY DEPENDING ON ROOFING
MANUFACTURER. CONTRACTOR SHALL INSTALL A COMPLETE CODE
COMPLIANT AND WARRANTIED ROOFING SYSTEM BASED ON THE SPECIFIED
ROOFING MANUFACTURER WRITTEN INSTRUCTIONS AND INSTALLATION
GUIDELINES.
G. ROOFING INSULATION THERMAL LETTER-VALUE AND CORRESPONDING R-
VALUE MAY VARY DEPENDING ON INSULATION MANUFACTURER. ROOFING
CONTRACTOR TO CONSULT INSULATION MANUFACTURERS WRITTEN
DOCUMENTATION AND PROVIDE A ROOF INSULATION THICKNESS TO MEET
OR EXCEED THE IECC REQUIREMENT.
H. PROVIDE MINIMUM 15-0CLEARANCE FROM ANY INTAKE FOR EQUIPMENT
AND VENT STACKS. ALERT DESIGN PROFESSIONAL OF ANY CONFLICTS
PRIOR TO CONSTRUCTION.
I. ONCE ROOF WORK BEGINS, THE CONTRACTOR IS ACCEPTING CONDITIONS
AND WILL BE RESPONSIBLE FOR ALL DEMOLITION AND NEW WORK
REQUIRED TO PROVIDE A WATERTIGHT ROOF SYSTEM.
J. THE CONTRACTOR SHALL ENSURE THAT UPON COMPLETION OF ROOF
WORK, ALL GUTTERS, DOWNSPOUTS AND ROOF DRAINS ARE CLEAN AND
CLEAR OF DEBRIS TO PROVIDE AN UNOBSTRUCTED, FREE FLOW OF WATER.
K. FIELD VERIFY AND COORDINATE REPLACEMENT OF ROOF PENETRATIONS AS
REQUIRED.
# DATE DESCRIPTION
ROOF PLAN KEYNOTES
R1 NEW CONTINUOUS RIDGE VENT. COORDINATE W/ VENTILATION TROUGHS AND
INSULATION
R2 NEW ASPHALT SHINGLES SYSTEM
R3 PROVIDE 24-INCHES OF ICE AND WATER SHIELD AT EACH SIDE OF VALLEYS AND
RIDGES AND ALONG EAVES. CONTRACTOR OPTION TO PROVIDE OVER ROOF
COMPLETE.
R4 NEW PREFINISHED GUTTER AND DOWNSPOUT SYSTEM