HomeMy WebLinkAboutA3.01 EXTERIOR ELEVATIONSFIRST FLOOR - EXISTING 0' - 0" ROOF 9' - 0" B.O. FOOTING -3' - 6" 1 A2.01 1 A2.02 NEW ROOF SYSTEM PREFINISHED FASCIA PREFINISHED GUTTER & DOWNSPOUT EXISTING MASONRY NEW BRICK MASONRY FIRST FLOOR - EXISTING 0' - 0" ROOF 9' - 0" B.O. FOOTING -3' - 6" 1 A2.011 A2.02 A2.02 2 1 2 EXIST. MASONRY CONTRACTOR OPTION FOR REINF. CONC. FOUNDATION WALL NEW BRICK MASONRY NEW ROOF SYSTEM CONTINUOUS RIDGE VENT PREFINISHED GUTTER & DOWNSPOUT DOUBLE HUNG INSULATED WINDOW SYSTEM PREFINISHED FASCIA FIRST FLOOR - EXISTING 0' - 0" ROOF 9' - 0" B.O. FOOTING -3' - 6" 2 A2.01 3 A2.02 NEW ROOF SYSTEM NEW BRICK MASONRY PREFINISHED FASCIA CONTINUOUS RIDGE BEAM PREFINISHED GUTTER & DOWNSPOUT CRICKET BEYOND NEW ROOF SYSTEM EXIST MASONRY NEW ENTRY DOOR SELECTED BY OWNER DOUBLE HUNG INSULATED WINDOW SYSTEM CONCRETE TOWARD DOWN SLAB EDGE JOB NO.: DATE: DRAWING TITLE: ISSUE: STAMP: Project Status 6015 ORCHARD HILL LANE P: 317.520.2558 INDIANAPOLIS, IN 46220 WWW.ARXTHEON.COM A3.01 EXTERIOR ELEVATIONS Project Number111 BENNET ROAD ADDITIONOwnerOctober 20, 2021111 BENNET ROAD, CARMEL, IN 46032Project NumberProject Status 1/4" = 1'-0"1 EAST - PROPOSED 1/4" = 1'-0" 3 WEST - PROPOSED 1/4" = 1'-0"4 SOUTH - PROPOSED ELEVATIONS KEYNOTES 1 CONTROL JOINT W/ SEALANT @ EXIST/NEW BRICK MASONRY 2 #5 STEEL DOWEL PIN @ CONCRETE W/ EPOXY ADHESIVE. EMBED MIN. 16" DEEP EACH SIDE OF JOINT. PROVIDE FULL HEIGHT. # DATE DESCRIPTION PLAN GENERAL NOTES 1. CORROSION-RESISTANT FLASHING IS REQUIRED AT THE HEAD, SILL, AND JAMBS OF EXTERIOR OPENINGS AND PENETRATIONS. 2. ADD SILICONE SEALANT TO EXTERIOR JOINTS AT EXTERIOR OPENINGS AROUND WINDOWS AND DOOR FRAMES AND PENETRATIONS THROUGH WALLS. REFER TO LOCAL CODES FOR REQUIREMENTS. 3. GENERAL CONTRACTOR TO VERIFY FORCE ON RAILING SYSTEM TO VERIFY ADEQUATE NUMBER OF SUPPORT POSTS PRIOR TO BIDDING THE PROJECT. COMFORM TO BUILDING CODE REQUIREMENTS FOR SYSTEM. 4. GUARDRAIL ELEMENTS SHALL BE SPACED TO PREVENT A 4-INCH SPHERE FROM PASSING THROUGH OPENINGS. 5. FLASHING SHALL BE INSTALLED AROUND ALL EXTERIOR OPEINGS. CAULK AND MAKE WEATHER-TIGHT. 6. SEAL EXTERIOR PENETRATIONS THROUGH EXTERIOR CLADDING TO ELIMINATE WATER INFILTRATION ONTO THE DRAINAGE PLANE. 7. PROVIDE DRIP CAP FLASHING AT ALL WINDOW & DOOR HEADS. 8. REFER TO FLOOR PLANS & SCHEDULES EXTERIOR OPENING SIZES AND LOCATIONS. 9. PROVIDE FLASHING AS REQUIRED TO PREVENT THE PENETRATION OF WATER INTO THE EXTERIOR SHELL OF THE BUILDING. 10. COORDINATE WITH CIVIL ENGINEERING DOCUMENTS. 11. REFERENCE SPECIFICATIONS, GENERAL NOTES AND DETAILS FOR MORE INFORMATION. 12. CONFIRM EXTERIOR SIGNAGE LOCATIONS WITH THE OWNER AND PROVIDE BLOCKING AND POWER REQUIRED. 07/27/22