HomeMy WebLinkAbout06030152 Site Plan
--'_..-i__ [Ij]J 1 0.00'
DTIJ ~
10.0' --
I N ~--,:::;
0 0: / ( SQL);
I l[) 33.7' ~ /~ ,
~ "-----
I I ~ / I ~
\ /...
\ I
IZ
\ I
\ oj
\ 0
~ OC
\ '0 I
CD
<9GoO ,N
u:-1;.'k I ,~
\Q-S- 0
<S>,J'>i'1- "<t
'f,.-:>U'O 33.8'- ~
I
--+
I IliID
- L
"
,.,~
i
BUCKINGHAM - ELEV 5C
LEFT HAND. Full Brick
FULL BSMT - 9' Walls
3 CAR - Side Entry
Gar. FFE = 914.3
1st Fir FFE = 916.1
Bsmt FFE = 906.3
Drive Slope = 6.6%
Note:
Minimum Front yard. Variable
Minimum Between Residences - 6'
Minimum Rear Yard. 20'
LOT # 5 /
I
+17,652 Sit
PAD 9140 PER PLA~
.-
Note:
Contractor should verify site
specific information depicted
hereon with the approved
construction plans for this
development
/ . -'-:J
8a:.f(IC .6\i~~lliJ[jj]jJ@@J ~@D'l\01J
./
...'" @@([]O@g 11" = ~@'
24.78'
OJ:]]
5'WALK
IXX.XI ::: Proposed Grade
- ::: Drainage Flow
XX.X ::: Existing Grade
&
cn4
SAN MH G~:;)/- ---. -
T~,~ _(~~.
Flood Hazard Note:
lot Number 5 lies within Zone "X" per the scaled location on
the Flood Insurance Rate Maps for Hamilton County, Indiana
(Community Panel #18057C0205F, dated February 19, 2003)
Note:
This drawing is based upon construction plans and/or record
drawings prepared by others and is not based upon a field survey.
COOR Consulting & Land Services, Corp. does not warrant the
correctness or integrity of this information. The contractor/owner
should verify existing conditions prior to construction. Any varying
field conditions or any discrepancy with the information contained
hereon should be immediately reported to COOR Consulting & land
Services. Corp_: failure to do so would result in the contractor/owners
assumption olliability.
oor@
@@D1J~I.\!JOl1DD1J\ID ~ O([]D1J@] ~@D'WD@@~~
@@1?[F)@1?1ID1l0@[]jJ
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 03/23/06 JOB #2004-250.005 REVISIONS:
WATER LINE
-
Cone Flatwork Sq. Ft = t1699
Public Walk Sq Ft = t1209
Sod Sq Yds = t872
Seeding Sq Ft = t6726
Note:
The proposed construction grades depicted hereon are based upon
information, proposed grades and/or contours, taken from the
approved construction plans prepared for this subdivision. Unless
stated hereon, no information pertaining to but not limited to,
fluctuating water table elevations, soil types or conditions within the
building area of said lot, has been provided or referenced on said
plans. With the construction of a basement, it is recommended that
the lowest floor elevation be constructed at least two (2) feet above
any adjoining bodies of water unless a study of facts reveals
otherwise. Should any ground water be witnessed during the
excavation of said structure, the lowest floor elevation should be
raised at least two (2) feet above the ground water level and
additional construction techniques should be incorporated to
alleviate future problems.
LONGRIDGE ESTATES
SECTION ONE
PC 3, SLIDE 729
INSTR #200500063316
PLOT PLAN
Prepared For:
LOT # 5
13669 MONIQUE DRIVE
WESTFIELD, IN 46074
Pulte Homes of Indiana