HomeMy WebLinkAboutCPC-Pavilion_Permit Set_20220620_Sheet-A.501SEE SPECS.1' - 6 3/4"REINFORCED CONCRETE SLAB -SEE STRUCTURAL DWG'S.1-1/2" THIN-STONE VENEER OVER 5/8" CEMENT BOARD OVER 2"X6" FT WOOD STUD FRAMING OVER 1/2" CEMENT BOARD OVER 1-1/2" THIN-STONE VENEER.5/8" CEMENT BOARD.DOUBLE-SIDED GAS FIREPLACE.3/4" FT PLYWOOD.PROVIDE FT BLOCKING FOR SIGNAGE/LOGO MOUNTING.2X FT HEADER.MINIMUM7' - 7"ALL 2X WOOD STUDS TO BE FIRE TREATED WITHIN 91" FROM THE BASE OF THE APPLIANCE.NOTE:THE LV SERIES REQUIRES A MINIMUM ENCLOSURE HEIGHT OF 91" MEASURED FROM THE BOTTOM OF THE APPLIANCE. FOR TEMPERATURE REQUIREMENTS, THIS AREA MUST BE LEFT UNOBSTRUCTED. SOME VENTING CONFIGURATIONS THAT REQUIRE MORE VERTICAL RISE WILL REQUIRE A LARGER ENCLOSURE TO PROVIDE MINIMUM VERTICAL CLEARANCE BETWEEN VENT PIPES AND COMBUSTIBLES. REFER TO MANUFACTURER'S DETAILS AND SPECIFICATIONS.1" MINIMUM ALL SIDES FOR SECTIONS OF VERTICAL VENTING. WHEN PASSING THROUGH A CEILING, USE FIRE STOP SPACER W500-0028. REFER TO MANUFACTURER'S DETAILS AND SPECIFICATIONS.EXTEND FLUE 3 FEET MINIMUM ABOVE THE ROOF SURFACE, AND 2 FEET ABOVE OTHER OBSTACLES WITHIN A 10 FEET RADIUS. COORDINATE WITH MECHANICAL AND FIRE PROTECTION CONTRACTOR.7' - 0".SEE SPECS.1' - 6 3/4"SEE SPECS.5' - 4 3/4"SEE SPECS.3' - 5 1/4"REINFORCED CONCRETE SLAB -SEE STRUCTURAL DWG'S.DOUBLE-SIDED GAS FIREPLACE.3/4" FT PLYWOOD.PROVIDE FT BLOCKING FOR SIGNAGE/LOGO MOUNTING.2X FT HEADER.SEE SPECS.1' - 2" MIN.2X STUDS @ 16" O.C.2X WOOD STUDS @ 16" O.C.MINIMUM7' - 7"ALL 2X WOOD STUDS TO BE FIRE TREATED WITHIN 91" FROM THE BASE OF THE APPLIANCE.1" MINIMUM ALL SIDES FOR SECTIONS OF VERTICAL VENTING. WHEN PASSING THROUGH A CEILING, USE FIRE STOP SPACER W500-0028. REFER TO MANUFACTURER'S DETAILS AND SPECIFICATIONS.NOTE:THE LV SERIES REQUIRES A MINIMUM ENCLOSURE HEIGHT OF 91" MEASURED FROM THE BOTTOM OF THE APPLIANCE. FOR TEMPERATURE REQUIREMENTS, THIS AREA MUST BE LEFT UNOBSTRUCTED. SOME VENTING CONFIGURATIONS THAT REQUIRE MORE VERTICAL RISE WILL REQUIRE A LARGER ENCLOSURE TO PROVIDE MINIMUM VERTICAL CLEARANCE BETWEEN VENT PIPES AND COMBUSTIBLES. REFER TO MANUFACTURER'S DETAILS AND SPECIFICATIONS. 2' - 8 3/4"SAFETY BARRIEREXTEND FLUE 3 FEET MINIMUM ABOVE THE ROOF SURFACE, AND 2 FEET ABOVE OTHER OBSTACLES WITHIN A 10 FEET RADIUS. COORDINATE WITH MECHANICAL AND FIRE PROTECTION CONTRACTOR.1-1/2" THIN-STONE VENEER OVER 5/8" CEMENT BOARD OVER 2"X6" FT WOOD STUD FRAMING OVER 1/2" CEMENT BOARD OVER 1-1/2" THIN-STONE VENEER.CAST-STONE CAP.CAST-STONE CAP..CAST-STONE CAP.7' - 0"CAST-STONE CAP.CAST-STONE CAP.ASPEN PROJECT #:SEAL:9645 Lincoln-Way Lane Suite 201 Frankfort, IL. 60423PRE-GP/PERMIT SETCOPYRIGHT ASPEN GROUP INC. USE OF THESE DOCUMENTS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED, PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. RE-USE, REPRODUCTION, OR PUBLICATION IN WHOLE OR IN PART IS PROHIBITED. READ DIMENSIONS. DO NOT SCALE DRAWINGS. REPORT ANY INCONSISTENCIES TO THE ARCHITECT IMMEDIATELY. EXPIRES:6/22/2022 3:51:02 PMCollege Park Church -Outdoor Pavilion07-00552606 West 96th Street, Indianapolis, INA.501WALL SECTIONS3/4" = 1'-0"1WALL SECTION - 13/4" = 1'-0"2WALL SECTION - 2REVISIONSNo. Date By DescriptionA 06/ 20/ 2022 Pre-GP / Permit Set