HomeMy WebLinkAboutCPC-Pavilion_Permit Set_20220620_Sheet-G.103PERFORMANCE STANDARDS (CONT'D)@A/CACOUST.A.C.T.A.D.A.D.J.A.F.F.AGG.AL.ALT.ANCH.ANOD.APP'D.ARCH.ASSOC.AUTO.AUX.AVG. A.P.C.BARR. BD.BLK.BLDG.BLKG.BOT.B.PL.BSMT.B.U.R.CAB.CEM.CER.CHK'D.C.J.C.L.CLG.CLR.CLOS.C.M.U.CPT.COL.CONC.CON'D.CONST.CONT.CONTR.COORD.CPT.C.T.CTR.C.V.B.CYL.D.DBL.DEMO.DEP.DET.D.F.DIA.DIM.DN.DR.D.S.DWG.(S)DWL.EA.E.J.EL.ELECT.ELEV.ENCLOS.EP.EQ.EXIST., EX'G.EQUIP.EXH.EXP.EXT.FAB.F.D.FDN.FIN.FLEX.FLR.FRP.FT.(')FTG.FURN.GA.GALV.G.C.GEN.GL.GYP. BD.H.HCPD.H.C.WD.HDW.H.M.HORIZ.H.P.H.S.S.HT.H.V.A.C.I.D.IN.(")INFO.INSUL.INT.ATAIR CONDITIONERACOUSTICALACOUSTICAL CEILING TILEACCESS DOORADJACENT, ADJUSTABLEABOVE FINISH FLOORAGGREGATEALUMINUMALTERNATEANCHOR, ANCHORAGEANODIZEDAPPROVEDARCHITECTURALASSOCIATEDAUTOMATICAUXILIARYAVERAGEACOUSTICAL PANEL CEILINGBARRIERBOARDBLOCKBUILDINGBLOCKING BOTTOMBEARING PLATEBASEMENTBUILT UP ROOFINGCABINETCEMENTCERAMICCHECKEDCONTROL JOINTCENTER LINECEILINGCLEARCLOSETCONCRETE MASONRY UNITCARPETCOLUMNCONCRETECONTINUEDCONSTRUCTIONCONTINUOUSCONTRACTORCOORDINATECARPETCERAMIC TILECENTERCOVED VINYL BASECYLINDERDEEP (DEPTH)DOUBLEDEMOLITIONDEPRESSION, DEPRESSDETAILDRINKING FOUNTAINDIAMETERDIMENSIONDOWNDOORDOWN SPOUTDRAWING(S)DOWELEACHEXPANSION JOINTELEVATIONELECTRICALELEVATORENCLOSUREEPOXY PAINTEQUALEXISTINGEQUIPMENTEXHAUSTEXPANSION, EXPOSEDEXTERIORFABRICATE(D)FLOOR DRAINFOUNDATIONFINISHEDFLEXIBLE FLOORFIBERGLASS REINFORCED PANELSFEET (FOOT)FOOTINGFURNISH, FURNITUREGAUGEGALVANIZEDGENERAL CONTRACTORGENERALGLASSGYPSUM WALL BOARDHIGHHANDICAPPEDHOLLOW CORE WOODHARDWAREHOLLOW METALHORIZONTALHIGH POINTHOLLOW STEEL SECTIONHEIGHTHEATING VENTILATING AIR-CONDITIONINGINSIDE DIMENSIONINCHINFORMATIONINSULATION INTERIORJAN.JT.L.LAM.LAV.LB.(S)LTWT. CONC.MANU.MAS.MAT.MAX.MIN.MECH.MED.MFR.MISC.M.O.MTD.MTG. HT.MTL.N/ANEC.N.I.C.N.T.S.NO.(#)NOM.O.C.O.D.O.S.B.OH.OPENG.OPP.PART.PFAB.PF.PL.P.LAM.PLMBG.PLAS.PLWD.PR.PREFAB.PROV.PSF.PSI.PT.PVC.QT.R.R.B.R.D.RE.REINF.RELOC.REPL.REQ'D.REV.R.H.RM.R.O.ROOFG.S.C.SCHED.SCWD.SEAL.SHT.SIM.SQ.S.S.STD.STL.STRUC.SPEC.(S)ST.SUSP.S.V.B.T.T&BT>EMP.TERR.THK.THRUTLT.T.O.S.T.O.W.T.S.TYP.UL.U.N.OV.B.V.C.T.VERT.V.I.F.V.T.V.W.C.W/W/IW/OW.W.C.WD.WP.WT.W.W.F.JANITORJOINTLENGTHLAMINATELAVATORYPOUND, POUNDSLIGHTWEIGHT CONCRETEMANUFACTUREDMASONRYMATERIALMAXIMUMMINIMUMMECHANICALMEDIUMMANUFACTURERMISCELLANEOUSMASONRY OPENINGMOUNTEDMOUNTING HEIGHTMETALNOT APPLICABLENECESSARYNOT IN CONTRACTNOT TO SCALENUMBERNOMINALON CENTEROUTSIDE DIMENSIONORIENTED STRAND BOARDOVERHEADOPENINGOPPOSITEPARTITIONPRE-FABRICATEDPRE-FINISHEDPLATEPLASTIC LAMINATEPLUMBINGPLASTERPLYWOODPAIRPREFABRICATEDPROVIDEPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPAINT, POINTPOLYVINYL CHLORIDEQUARRY TILERADIUSRUBBER BASEROOF DRAINREFER TOREINFORCEMENTRELOCATE, RELOCATEDREPLACEREQUIREDREVISE, REVISIONRIGHT HANDROOMROUGH OPENINGROOFINGSOLID CORESCHEDULESOLID CORE WOODSEALANTSHEETSIMILARSQUARESTAINLESS STEELSTANDARDSTEELSTRUCTURAL (STRUCTURE)SPECIFICATIONSTAIN AND VARNISHSUSPEND, SUSPENDEDSTRAIGHT VINYL BASETOP, THICKTOP AND BOTTOMTONGUE AND GROOVETEMPERATURETERRAZZOTHICK, THICKNESSTHROUGHTOILETTOP OF STEELTOP OF WALLTUBE STEELTYPICALUNDERWRITERS LABORATORIESUNLESS NOTED OTHERWISEVINYL BASEVINYL COMPOSITION TILE VERTICALVERIFY IN FIELDVINYL TILEVINYL WALL COVERINGWITHWITHINWITHOUTWIDTH, WIDEWATER CLOSETWOOD WORK POINTWEIGHTWELDED WIRE FABRICABBREVIATIONS3. OVERHEAD STOPS SHALL BE USED IN AREAS WHERE FLOOR STOP WOULD IMPEDE TRAFFIC AND WHERE ADJACENT WALL FOR WALL STOP IS MORE THAN 90 DEGREES. OVERHEAD STOPS SHALL BE GJ100 UNLESS OTHERWISE SPECIFIED.L. FLUSH BOLTS1. FLUSHBOLTS SHALL BE UL LISTED AND SHALL HAVE " MIN. DIAMETERROD OF BRASS, BRONZE OR STAINLESS STEEL WITH 12" MIN. LONGROD FOR DOORS UP TO 7' IN HEIGHT. PROVIDE LONGER RODS FOR DOORS EXCEEDING 7' IN HEIGHT. AUTOMATIC FLUSHBOLTS SHALL HAVE AUTOMATIC LATCHING AND UNLATCHING MECHANISM. BOLTSSHALL HAVE " THROWS. PROVIDE DUST PROOF STRIKES FOR FLOORBOLTS EXCEPT WHERE SPECIFIED THRESHOLD CONSTRUCTION PROVIDESNON-RECESSED STRIKE FOR BOLT. PROVIDE COORDINATORS AS APPLICABLE.M. ASTRAGALS1. ASTRAGALS FOR "B" & "C" LABEL PAIR DOORS SHALL BE S.S., " THICK, 1" WIDE AND FULL HEIGHT OF THE DOOR.2. ASTRAGALS USED AS LOCK GUARD SHALL BE S.S. AND 12".N. HARDWARE FUNCTION INDEXSTANDARD HARDWARE FUNCTIONSF-75 - "PASSAGE" ALWAYS UNLOCKED FROM BOTH SIDESF-76 - "PRIVACY" BUTTON LOCK FROM INSIDEF-86 - PASSAGE TO SECURE SPACES - ALWAYS LOCKED FROM OUTSIDE, ENTRANCE WITH KEY OR CARD READER. ALWAYS UNLOCKED FROM INSIDE BY PROXIMITY SENSOR.F-87 - "SECURITY" ALWAYS LOCKED FROM BOTH SIDES, OPEN WITH KEY OR CARDREADER.F-89 - EMERGENCY EXIT ONLY, ALWAYS LOCKED FROM OUTSIDE, ALWAYS OPERATESFROM INSIDEF-89XXX SAME AS F-89 EXCEPT NO VISIBLE HARDWARE ON EXTERIOR9. HARDWARE SUPPLIER TO VIST PROJECT SITE, AT APPROPRIATE TIME, TO VERIFY DOOR OPENINGS DIVISION 09 - 09 00 00 FINISHESCOMPLY WITH ALL APPLICABLE INDUSTRY STANDARDS INCLUDING, BUT NOT LIMITED TO, CRI AND ASSOCIATED SECTIONS OF ASTM.1. DRYWALL PARTITIONSA. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NEW METAL STUD PARTITION CONSTRUCTION WHERE INDICATED ON THE DRAWINGS.B. ALL NEW PARTITION CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS, AND SHALL CONFORM TO BUILDING STANDARD SPECIFICATIONS WHERE APPLICABLE.C. HARDWARE1. 3-" 22 GAUGE METAL STUDS AT 16" O.C.2. METAL FURRING CHANNELS: 22 GAUGE HAT SHAPED 1-" WIDE X " DEEP3. SCREWS: TYPE S AND S-12 BUGLEHEAD AND PANHEAD SIZES TO SUIT THICKNESS,ASTM C6464. HANGERS: 8 GAUGE ANNEALED, GALVANIZED WIRE5. COLD ROLLED CHANNELS: " AND 1-", 16 GAUGE STEEL6. DRYWALL: " TYPE-X MINIMUM 1 LAYER EACH SIDE, USE MULTIPLE LAYERS AS NECESSARY TO DEVELOP REQUIRED FIRE RATING. SEE DETAILS AND FLOOR PLANS. REFER TO WALL TYPE SCHEDULE FOR SPECIFIC PLACEMENT OF DRYWALL.7. ACCESSORIESa. CORNER REINFORCEMENTS CASING BEADS AND METAL TRIM - 22 GAUGEb. GALVANIZED SHEET STEEL WITH PERFORATED FLANGES TO RECEIVE JOINT COMPOUNDc. CONTROL JOINTS - USG #093 ROLL FORMED ZINC OR EQUALd. JOINT TREATMENT MATERIALS - DURABOND 90 OR PROFORM QUICK SET 90, HARD SETTING TYPE FOR BASE COAT; EASY SAND OR PROFORM QUICK SET LIGHTFOR TOP COATS. NO SUBSTITUTIONS WITHOUT APPROVAL OF ARCHITECTe. ACOUSTICAL SEALANT: APPLY TO TOP AND BASE OF ALL PARTITIONS AND AROUND HVAC DUCTS AND ELECTRICAL BOXES OR OTHER ITEMS INSERTEDINTO THE PARTITIONS.D. PROVIDE GALVANIZED CORNER REINFORCEMENT AT ALL EXTERIOR CORNERS AND J-MOLD OR L-MOLD AT ALL EXPOSED GYPSUM BOARD EDGES.E. PROVIDE BRACING AND STRUCTURAL SUPPORT AS NECESSARY AND/OR REQUIRED BY BUILDING CODES, FOR AL WALLS, SOFFITS AND CEILINGS.F. FINISHING OF GYPSUM WALLBOARD:GENERAL: APPLY TREATMENT AT GYPSUM WALL BOARD JOINTS(BOTH DIRECTIONS), FLANGES OF THE TRIM ACCESSORIES, PENETRATIONS, FASTENER HEADS, SURFACE DEFECTS, AND ELSEWHEREWHERE REQUIRED TO PREPARE WORK FOR DECORATION. PREFILL OPEN JOINTS AND ROUNDED ORBEVELED EDGES, IF ANY,USING TYPE OF COMPOUND NOTED IN SECTION 1C ABOVE. APPLY JOINT TAPE AT JOINTS BETWEEN GYPSUM BOARDS, EXCEPT WHERE TRIM ACCESSORIES ARE INDICATED. APPLY JOINT COMPOUND IN 3 COATS(NOT INCLUDING PREFILL IN OPENING IN BASE), AND SAND BETWEEN LAST 2 COATS AND AFTER LAST COAT. PARTIAL FINISHING: OMIT THIRD COAT(IF SPECIFIED) AND SANDING ON CONCEALED WALLBOARD WORK WHICH IS INDICATED FOR DRYWALL FINISHING OR WHICH REQUIRES FINISHING TO ACHIEVE FIRE-RESISTANCE RATING, SOUND RATING OR TO ACT AS AIR OR SMOKE BARRIER.LEVELS OF FINISH: PROVIDE A LEVEL 4 FINISH ON ALL WALLS UNLESS THEY MEET THE FOLLOWING CRITERIA, OR INDICATED DIFFERENTLY ON PLAN:FLARED GYPSUM BULKHEADS AROUND EACH SKYLIGHT/CLERESTORY WINDOW: LEVEL 4ANY WALL SURFACE WITHIN 100 FEET OF AN EXTERIOR WINDOW: LEVEL 4WHERE CONTIGUOUS WALL SURFACES CONTINUE WITHIN THE SAME PLANE BEYOND 100 FEET,MAINTAIN LEVEL 4 FINISH SO AS NOT TO SEE A VISUAL DIFFERENCE IN THE FINISH OF THE WALL.ANY WALL SURFACE THAT IS DIRECTLY WASHED BY UPLIGHTING OR DOWNLIGHTING: LEVEL 4WHERE CONTIGUOUS WALL SURFACES CONTINUE WITHIN THE SAME PLANE BEYOND 100 FEET,MAINTAIN LEVEL 4 FINISH SO AS NOT TO SEE A VISUAL DIFFERENCE IN THE FINISH OF THE WALL.ANY WALL SURFACE TO RECEIVE AN EPOXY OR SEMIGLOSS FINISH: LEVEL 42. ACOUSTICAL CEILINGS A. ALL CEILING CONSTRUCTION AND MATERIALS WITHIN AREA OF REMODELING WORK ARE NEW, UNLESS NOTED OTHERWISE. REFER TO REFLECTED CEILING PLAN FOR MORE INFORMATION AND TO FINISH PLAN FOR SPECIFICATIONS.B. UNLESS NOTED OTHERWISE, PROVIDE ALL MATERIALS AND LABOR NECESSARY FOR THEINSTALLATION OF ARMSTRONG CIRRUS SECOND LOOK II ACOUSTICAL CEILING TILE WITHBEVELED TEGULAR EDGE PROFILE AND 15/16" SUSPENSION SYSTEM OR APPROVED EQUAL.C. SUBMIT TWO SAMPLES OF CEILING TILE FOR APPROVAL.D. INCLUDE ALL NECESSARY TRIM AND MOLDINGS FOR A COMPLETE INSTALLATION.E. PROVIDE 2% OF AMOUNT INSTALLED TO OWNER FOR ATTIC STOCK.3. RESILIENT BASE AND VINYL FLOORINGA. CONTRACTOR TO FURNISH AND INSTALL NEW RESILIENT BASE AS SHOWN ON DRAWINGS, AND IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ADJUST TILE LAYOUT AS NECESSARY TO AVOID USE OF CUT WIDTHS LESS THAN 6" AT ROOM PERIMETERS. ALL RESILIENT BASE CUTS TO OCCUR AT GREATER THAN 4" FROM CORNERS.B. REFER TO FINISH PLAN FOR NEW VINYL BASE AND FLOOR SPECIFICATIONS. COVE BASE AT CARPETING, COVE BASE AT VINYL FLOORING. CONTRACTOR IS TO PROVIDEVINYL REDUCER STRIPS AS REQUIRED AND AS DEEMED NECESSARY BY ARCHITECT IN FIELD.C. FURNISH AND INSTALL ALL HARD SURFACE FLOORING, TRANSITION STRIPS AND ACCESSORIES IN AREAS INDICATED ON THE DRAWINGS. INCLUDE ALL REQUIRED FLOORPREPARATION, SEALERS, AND ADHESIVES REQUIRED FOR A COMPLETE INSTALLATION.D. SUBMIT REPRESENTATIVE SAMPLES OF EACH TYPE OF FLOOR TILE AND BASE SPECIFIED. PROVIDE OWNER WITH ONE CASE OF REPLACEMENT TILE FOR EACH COLOR SPECIFIED.4. CARPET:A. REFER TO FINISH PLAN FOR NEW CARPET SPECIFICATIONS. PROVIDE A SEAMING DIAGRAM FOR ARCHITECT'S APPROVAL. PROVIDE MISCELLANEOUS CARPET ACCESSORIES AS REQUIRED FOR ARCHITECT'S APPROVAL. LATEX CONCRETE FLOOR AS REQUIRED. ALL WORK TO BE DONEIN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.B. CARPET CONTRACTOR TO MAKE ALL REQUIRED ARRANGEMENTS WITH CONSTRUCTION MANAGER FOR DELIVERY OF MATERIALS AND/OR EQUIPMENT (AND HOISTING IF NECESSARY) PRIOR TO SUBMITTING A BID. IT SHALL BE HIS RESPONSIBILITY TO CHECK THE RULES ANDREGULATIONS GOVERNING WORK ON THE PREMISES, INCLUDING: DATES AND TIMES OF DELIVERIES, INCLUDING OVERTIME CHARGES. VERIFICATION OF ALL DIMENSIONS, CLEARANCES AND OPENINGS.C. CARPET CONTRACTOR SHALL SUBMIT A LAYOUT OF AREAS TO BE COVERED SHOWING PATTERN, COLOR, TYPE OF MATERIAL, SEAMS, FILLS AND DIRECTION OF PILE AND PATTERN.D. FLOORING IN CLOSETS SHALL MATCH ADJACENT AREA, UNLESS NOTED OTHERWISE.F. PROVIDE TEMPORARY COVERINGS/PROTECTION FOR INSTALLED FLOOR COVERINGS TO GUARD AGAINST SOILING OR DAMAGE. REPLACE DEFECTIVE OR DAMAGED AREAS.G. COORDINATE AND PROVIDE ALL CUTOUTS FOR POWER, TELEPHONE AND SIGNAL PENETRATIONS.H. PROVIDE MANUFACTURER'S RECOMMENDED INSTALLATION TECHNIQUE FOR ALL SPECIFIED CARPET TYPES.5. PAINTING AND DECORATING:A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS AND LABOR AS NECESSARY TO PROVIDE PAINTING AND DECORATING WORK AS SPECIFIED AND INDICATED ON THE DRAWINGS.1. UNLESS NOTED OTHERWISE, PAINT ALL GYPSUM BOARD FASCIASAND SOFFITS TO MATCH ADJACENT WALL COVER.2. PAINT ALL FIRE EXTINGUISHER/FIRE HOSE VALVE CABINETS AND MISCELLANEOUS SPECIALTIES WITH SEMI-GLOSS PAINT FINISH TO MATCH 3. SHEEN LEVELS:a. WALLS: EGGSHELL/SATINb. CEILINGS: FLATc. FRAMES, FERROUS METALS: ALKYD ENAMEL SATINd. DOORS: ALKYD ENAMEL SATINe. DOORS: OIL BASES STAIN4. UNLESS NOTED OTHERWISE, ALL TOGGLE SWITCH AND RECEPTACLE COVER PLATES ARE TO BE WHITE.B. ALL WALLS, DOORS, FRAMES AND WOODWORK SHALL BE FREE FROM DEFECTS AND BEFILLED AND SANDED SMOOTH PRIOR TO RECEIVING PAINTED AND/OR NATURAL FINISHES. NEW WORK SHALL BE PRIMED AND PAINTED WITH NOT LESS THAN TWO FINISHED COATS.C. THE PAINTING CONTRACTOR SHALL EXAMINE ALL WALL SURFACES AND PROVIDE NECESSARY TOUCH-UP PATCHING AND/OR PAINTING UPON COMPLETION OF WORK BY ALL TRADES.D. SUBMIT THREE 12" X 12" DRAWN-DOWN SAMPLES OF EACH COLOR SPECIFIED FOR ARCHITECT'S APPROVAL.E. PRODUCTS1. ACCEPTABLE MANUFACTURER: BENJAMIN-MOORE OR SHERWIN-WILLIAMSDIVISION 10 - 10 00 00 SPECIALTIES1. PROVIDE THE SPECIFIED PRODUCT AND ALL REQUIRED LABOR AND MATERIALS FOR A COMPLETE INSTALLATION, ANY ADDITIONAL HARDWARE, BLOCKING, SURFACE PREPARATIONS, SUPPORT SYSTEMS, REINFORCEMENT, ETC.2. COORDINATE WORK OF RELATED TRADES REGARDING ANY REQUIRED PREPATORY AND/OR FINISH WORK ASSOCIATED WITH INSTALLATION OF ANY SPECIALTIES. PROTECT ALL INSTALLED SPECIALTIES AGAINST DAMAGE THROUGHOUT THE DURATION OF THE WORK. REPLACE ALL DEFECTIVE OR DAMAGED UNITS.A. FIRE EXTINGUISHERS, REFER TO FP1.DIVISION 11 - 11 00 00 EQUIPMENTA. PRE-PURCHASED EQUIPMENT1. APPLIANCES2. REFER TO DRAWINGS FOR EQUIPMENT SPECIFIED AS PART OF THIS WORK.DIVISION 23- 23 00 00 MECHANICALA. SCOPE OF WORK: THIS CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND SERVICES AS NECESSARY TO PROVIDE A COMPLETE AND OPERATING HEATING,AIR CONDITIONING AND VENTILATION SYSTEM, PER THE ENGINEERING DOCUMENTS. CONTRACTOR SHALL VISIT SITE AND DETERMINE THE EXACT LOCATIONS ANDELEVATIONS OF EXISTING DUCTWORK, PIPING AND FIRE PROTECTION EQUIPMENT,WHERE APPLICABLE. CONSTRUCTION MANAGER SHALL BE RESPONSIBLE FOR THE REMOVAL OF EXISTING WORK AS NECESSARY TO ACCOMMODATE NEW WORK. REFER TO ENGINEER'S DOCUMENTS. MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL FIRESTOPPING RELATED TO MECHANICAL PENETRATIONS.B. ORDINANCES, REGULATIONS, AND BUILDING CODES: ALL WORK SHALL BE IN STRICTACCORDANCE WITH APPLICABLE ORDINANCES, REGULATIONS AND BUILDING CODES. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO PERFORM THIS WORK.DIVISION 26 - 26 00 00 ELECTRICALA. SCOPE OF WORK: THIS CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR AND SERVICES AS NECESSARY TO PROVIDE A COMPLETE AND OPERATING ELECTRICALSYSTEM, PER THE ENGINEERING DOCUMENTS. ANY CONFLICT SHOULD BE BROUGHTTO ARCHITECT'S ATTENTION. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL FIRESTOPPING RELATED TO ELECTRICAL PENETRATIONS.B. ORDINANCE, REGULATIONS AND BUILDING CODES: ALL WORK SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE ORDINANCES, REGULATIONS AND BUILDING CODES. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO PERFORM THIS WORK.C. TELEPHONE/DATA SYSTEMS COORDINATION: CONTRACTOR SHALL COORDINATE HISWORK WITH THE OWNER'S TELEPHONE AND COMMUNICATIONS VENDOR PRIOR TO COMMENCING WITH NEW WORK.DIVISION 31 - 31 00 00 EARTHWORK1. EARTHWORK: EXCAVATE FOR MASONRY FOUNDATION TO A MINIMUM OF 4 FT. BELOW FINISH GRADE. EXCAVATE FOR SLABS ON GRADE TO DEPTH NECESSARY TO ATTAIN 2000 PSI MINIMUM SOIL BEARING VALUE, BUT NOT LESS THAN DEPTH INDICATEDON THE DRAWINGS. BEARING VALUE OF SOIL FOR ALL FOUNDATIONS SHALL BE VERIFIED BY THE TESTING LABORATORY BEFORE PLACING CONCRETE. ALL FOOTINGS SHALL BEARON UNDISTURBED SOIL OR COMPACTED FILL WITH A 2500 PSI MINIMUM BEARING VALUE. EXCAVATE TO LINES AND GRADES REQUIRED. REMOVE ALL ORGANIC MATERIAL AND ALL OBSTRUCTIONS WHICH WOULD INTERFERE WITH THE WORK. REMOVE EXCESS AND UNSUITABLE MATERIAL WHICH CAN NOT BE DISTRIBUTED ON-SITE. PROVIDE ADDITIONAL FILL MATERIALS AS NECESSARY TO ACHIEVE LINES AND GRADES INDICATED.2. FILL AND BACKFILL: FILL AND BACKFILL MAY BE EXCAVATED SUBSOIL FREE OF DEBRIS, ORGANIC MATTER, ICE OR FROST LUMPS GREATER THAN 6 INCHES, OR ROCKS GREATER THAN 3 INCHES. GRANULAR FILL FOR USE BELOW SLABS AND PAVEMENT SHALL BE CRUSHED GRAVEL CONFORMING TO IDOT CA6 OR ASTM #67 WITH FINES. CLEAN MEDIUM SANDMAY BE PROPOSED AS FILL AND MUST BE APPROVED BY ARCHITECT AND E.O.R. BACKFILL AND COMPACT AROUND FOUNDATION WALLS IN A MANNER THAT WILL PREVENT DAMAGE TO OR SHIFTING OF THE WALLS. PLACE FILL IN LAYERS NOT TO EXCEED 8 IN. LOOSE MEASUREMENT. PROVIDE A MINIMUM OF 4 IN. COMPACTED GRANULAR FILL BELOW ALL SLABS AND PAVEMENT. COMPACT FILL MATERIALS TO A MAXIMUM DENSITY AT OPTIMUM MOISTURE AS FOLLOWS:A. UNDER STRUCTURAL BEARING 97%B. UNDER PAVEMENT AND SLABS ON GRADE 95%C. UNDER AREAS OF GENERAL GRADING 85%DO NOT PLACE FILL IN STANDING WATER. MAINTAIN THE EXCAVATIONS REASONABLY FREE OF WATER. PERFORM FINISH GRADING TO GRADES SHOWN, OR MEET EXISTING GRADES, PREVENT ACCUMULATION OF SURFACE WATER AT THE BUILDING, AND MINIMIZE EROSION DUE TO RUN-OFF. PROVIDE 4 IN. MINIMUM OF TOPSOIL IN LANDSCAPING AREAS.SYMBOLSNEW WALLEXISTING WALLEXISTING WALL TO BE REMOVEDNEW DOOR AND FRAME. REFER TO DOOR SCHEDULEEXISTING DOOR AND FRAME TO BE RELOCATED OR REMOVEDEXISTING DOOR AND FRAME TO REMAINDR#36"2Req.W"101E1tView NameFLOOR PLAN SYMBOLSAPLAN NOTE TAGROOM NAME AND NUMBERDOOR TAGSECTION TAGKEY NOTE TAGDETAIL TAGSTOREFRONT ELEVATION TAGWINDOW TAGALIGN FINISH WALLMATERIAL TAG (WALL AND FLOOR FINISH)WALL TAGEXIT SIGN TAGEGRESS DOOR CAPACITY TAGOCCUPANCY LOAD ROOM TAGRoomname1011A101SIM02.011A.501OLFOLRoom name150 SF15OLXX1iASPEN PROJECT #:SEAL:9645 Lincoln-Way Lane Suite 201 Frankfort, IL. 60423PRE-GP/PERMIT SETCOPYRIGHT ASPEN GROUP INC. USE OF THESE DOCUMENTS SHALL BE RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED, PUBLICATION THEREOF IS EXPRESSLY LIMITED TO SUCH USE. RE-USE, REPRODUCTION, OR PUBLICATION IN WHOLE OR IN PART IS PROHIBITED. READ DIMENSIONS. DO NOT SCALE DRAWINGS. REPORT ANY INCONSISTENCIES TO THE ARCHITECT IMMEDIATELY. EXPIRES:6/22/2022 3:51:16 PMCollege Park Church -Outdoor Pavilion07-00552606 West 96th Street, Indianapolis, ING.103PERFORMANCE STANDARDS,ABBREVIATIONS, ANDSYMBOLSREVISIONSNo. Date By DescriptionA 06/ 20/ 2022 Pre-GP / Permit Set