Loading...
HomeMy WebLinkAbout06030172 Site Plan " . '= ~ !he _ Corpantloll 8801 otiI .lftlD.1III IIIottlriorart_ lMI._""" IDdiaDa 4I2l&-1037 317-828-7100 317-828-7200 rAI IDpoorID& lJanwyIoc w.-,. _ GIS'LIS GeoIoI7 Note: This drawing is based on construction pians or record drawings, and is not based upon 0 field SUMY. The Schneider Co<poration does not worrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Co<poratlon immediately; faDing to do so results in the contractors assumption of 01/ liabDity. This Plot Pb1 Prepcred Fer: ..,., Hemes Lot # 73, containing 10,291 S.F.:!:, in Hecrtt. Knoll SectIan , 2 Instrument # 2006~00004470 PC 4 Slide 13 Coy TOIIl8hIp, Hemlton County SEe 20, 118N. ROJE 2633 PARAMOUNT CIRCLE (50' R/W) Westfield, IN 46074 _ Prepared Dote: 03/09/06: By: KAG Community Restrictions: Side Yard = 3' min. Rear Yard = 20' min. Aggregate = 6' B.H. Zoning - SI M /I Homes Finished Floor EleYOtion Information Pad Grode = 917.2 per plan I Pad Grode + 0.2' = Garage fIT (911.4) Garage fIT + 0.5' = Residential fIT (917.9) Residence fIT - 9.0' = Basement fIT (908.9) Note : The garage finished floor eleYO\ioo ~ 1.1' obo... \he tUrb 0\ the _, per pion. G!lOONO COVER CAlCULA llONS: Om. = 932 Sf! Public Walk = 197 Sf:!: PriYOte Walk =N/A Sf! Seeding =5,164 Sf! Sod =211 sn, from front of residence. Note: Sanitary Sewer Top of Costin9 information Upstream Manhole, TC= 917.13 Oownstream Manhole, TC=918.39 per record drwg. Note: Sump pump(s) to be placed by buDder os needed. V806.0050272 LOT i 73 o ~ co~co Plot Plan Legend I1iOO&I Proposed Grades 000.0 Existing Grades ___ 000.0- Contour Grade * Approx. Lateral Location - . - Sanitary Sewer Unes -Of- Storm Sewer Unes - " - Water Service Unes - - - - - - - Sub-Surface Orain Unes . , Manhole (Sonitory or Storm) . Boehi.. Inlet (Storm) l1li Curb Inlet (Storm) D End Section (Storm) JA. F.e Hydrant - """ - ...... - Flow Une of swale - BuDding Une (BL / BSL) - - - - - - - Easement Une Ootalof Graund/Stann Water: Flaw pattern of an IndMdual lol 'a: 1\1 \1 \ I I o Assumed North Scale : r = 30' Note: Builder to ensure positive drainage away from structure(s). 7--- " +- I I PARAMOUNT CIRCLE / - !O.O" Z '(\ '\ iZO' llrv.916.J R/W,," RQ1 CURB PER PL\N S' WAU( THE UPSTREAM MH TC ELEVA no~ SHALL BE NO LESS THAN l' -0. ~ BELOW RESIDENTIAL F.F.E.,\'}rr ,"'I I .\()1~~ Note: The basement elevation, depicted hereon, has been determined ond based upon the pod grades and/or contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, so" conditions, or son t)lles has been provided or stated on soid plans. It is recommended that the basement finished floor eleYOtions be at least two feet (2') abo.. the normal pool efeYOtion of any adjoining badies of water, unless 0 study of facts r",""ls otherwise. If during the excaYOlion process any ground water is witnessed, The Schneider Co<porotion should be notified immediately, The basement eleYOlion should be raised two feet (2') abo.. the ground water, and additional construction techniques should be incorporated to alleviate future problems, FLOOD HAZARD STATEMENT CERnFICA nON ~\\I\I\\I\lIIIIJ/I11"'''ll ~~~ L /l 11'/0< #- ~~ . v'P ~ ~~" ........... ,,~""'~ ~ ~./~G\S TE:;,~.......A~ ~~""<I- No 0"'..A:''Ei, ~:' ..~ ~ I { S0303 } ! % \ STA1E OF ..: ~ ~ /..... ..... ~ ~c~ ...(,.A(OIA~!:"" ~~ ~ '#J .............<:,'->~ ~l7h SUR~ \..~# rtl!"I/I/III11\1\\\\I\lII~ '\:L- l . :i ':ii . o 'I: 1 SLOPE: ~ IlSIIHT 16,9' - SUVP PIJlf> IIROOERICK B F1llI & USY RESIOENCI: ~ o sn o o. '8 .. 1917.3 I nVL~ ~55..qq()D yes /rt5 1915.2 I 48.3' ~ 15' R.O.E. .16.3' ~ ... '" 80.00' C. A. JJ7 VAR. D.U.&~.S.E.& L.M.A.E.&P .I.E.E. ~ '" ;" NOTE: IN THE RESIDENTIAL DISTRICTS LIMITING HEIGHT TO TWENTY-FIVE (25) FEET, A DWELLING MAY BE INCREASED IN HEIGHT TO THIRTY-FIVE (35) FEET PROVIDED THE SIDE AND REAR YARDS ARE INCREASED AN ADDITIONAL FOOT FOR EACH FOOT SUCH STRUCTURE EXCEEDS TWENTY-FIVE (25) FEET IN HEIGHT. PFR rARUFI 7nNINr. nRnlNANrF ?F. \ \ TYPICAL SWALE SECTION Flood Hazard Statement The accuracy of any flood hazard data shown on this plot plan is sub jett to mop scale uncertainty and to any other uncertainty In lacotion or eleYOtlan on the referenced flood Insurance rote mop (FIRM). None of the within described land lies within that special flood hazard zone. A', os sold land plots by scale on Community Mop Panel , 18057C0205f' of the flood insurance rote mops (FIRM) for HamDton County, Indiana. Doted May 19, 1981.