HomeMy WebLinkAboutC010.0 Trico plot plan Sewer permitJUL 13 PN 3:42
e�PP STOEELWERTH
-4 '," 0, ALWAYS ON
~� 7965 East 186th Street, Fishers, IN 4683E-2585
phone: 317.8495935 tux: 317.849.5942
LEGEND:
FX—X.-Xl MOPO= GRADE PER PIJW
XXXAB AS BUILT GRADE
S.S.D. _ _ SUB -SURFACE ORAIN
SANITARY SEWER
A9L
6' AS BUILT SANITARY LATERAL
PSL
B' PROPOSED SANITARY LATERAL
—
STORM SEWER
W
0/4' WATER CONNECTION
W —
WATER MAIN
.
SWALE
•
SANITARY MANHOLE
�J
STORM MANHOLE
■
CURB INLET
FlRE HYDRANT
.
END SECTION
D.V.65.SE
DRAINAGE UTUTY 4 SANITARY
SEWER EASEMENT
B.L
BUILDING LINE
R.O.E.
REGIIIATD ORMNAGE EASEMENT
M.LA.G,
MINIMUM LOWEST ADJACENT
MADE FOR LOT
D.U.
DRAINAGE UTUTY
W.W.
IMNDOW WELL
C.A.
DOMMR AREA
JOB ID CAM2B.62
CONTROL#103406 RCB
9854 FIDDLERS COURT
CARMEL, IN 46032
1" = 30'
LOT AREA:18,190 Sq. Ft.
D.U.M.D.E 1
— I
Bar BS.B MANHOLES MUST
ear 8 W.W. '0010.7' REMAIN ACCESSIBLE
3 cowED NG& AT GRADE
L6 PATO - W.W. B1.BAB AT ALL TIMES
1&OC
m
^m F.F.EI ].10 16
(UH) SO7.1A D
`O�EGIONAL1100
Pe
r 4.00' ui 727.5'
m 15.6];W
M
AGE
A
GAR.b m rriA
MA.
BENCHMARK
TGP OF CASTING=882.56
ALL UNDERGROUND SEWERS AND UTUTIES
SHOWN ARE PLOTTED BY SCALE MOW
'RECORD DRAWINGS' FURNISHED BY ENGINEER.
LOT 62
CAMDEN WALK
SECTION TWO "B"
INST. #2016053115
P.C.#5, SLIDE #566
ZONING: ROSO St
10' MINIMUM SIDEYARD
20' MINIMUM AGGREGATE
20' MINIMUM REAR YARD
Q: No.
�:80040474
STATE OF
NOTE: WS DRAMS Is NOT INTENDED TO BE
REPRESENTED AS A IRTRAMOANT OR ORIGINAL
BOUNDARY SL.. A RW1E SURT£Y OR A
SMflSKR LCGATR REPORT.
wryl[V m MAT uT
9)D/p1RB/E/ya�REVISE BAIL UT
1�3 �1101E�73/OIC DMM
a/m/a as
7236 Mayflovber'O a rive, onsville, ndlana, 46077 phone 317-844-9200 fax 317-844-9203 www.trico.eco
SANITARY SEWER PERMIT
Residential
LPN 455
Permit Type
Final
Subdivision
Camden Walk
Project WO
ENG2165620161,!
Section Number
Project Name
Camden Walk Section 2B
Lot Number
62
Project Developer
Camden Walk LLC !
Address
9854 Fiddlers Ct
Lift Station
Station 09
City
Carmel
Treatment Plant
TriCo WWTP!
Zip Code
Parcel Acreage
County
Hamilton
EDU in Gallons
310.00 ,`--
Application Fee
$150.00
Builder
Richard J Carriger Co
EDU Fee
$2,083.00;
Builder Phone
Interceptor Fee
$0.001 ~
Owner
Plan Review & Inspection
.
$0.00 i
.....
Owner Phone
Local Sewer Charge
$0.00.
Occupant
Other Fees
$0.00
Occupant Phone
Fees Due
$2,233.001
Low Pressure
Check Number
PLEASE NOTE: Installation of building sewer shall be per the specifications of the Tril Regional Sewer Utility (see reverse) and any
conditions noted below. All installations shall be inspected by TriCo personnel during 'open trench' phase and before backfilling with
stone to twelve inches above the pipe. NO footing or foundation drains, or other sources of ground or stormwater, shall be permitted to
enter Ti sanitary sewer system. Till will assume no liability for drains which are below the grade level of the nearest
downstream manhole nor for laterals which are extended beneath driveways or sidewalks. The permit holder (property owner,
developer or builder) will be responsible for damages to Trio's sewer system. This includes damages to manholes, castings, manhole
lids and the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in advance. All new
construction will be placed in billing three months after connection has been made or when water is connected, whichever comes first.
The Building has:
Water Service Carmel Utilities Slab Foundation Crawl Space Basement Yes
Grinder Station _-__Grit Interceptor Grease Trap Grease Interceptor
Per Ordinance 9-13-99 and the elevations provided, the lowest gravity plumbed floor level must be one foot or greater than either the
upstream or downstream manhole.
Main CW723-CW719 Upstream MH CW-723 Downstream MH CW-719
Cover Type Gasketed Gasketed
Lid Elevation 884.06 883.25
First Floor Elevation 887.10 887.10
Basement Elevation 877.10 877.10
3.04 3.85
Calculation is based on both Manhole Lid Elevations and the elevation of the First Floor.
The terms of the conditional permit, if any, are listed below
Trico currently requires that an I&I inspection is performed and a Certificate of Complai
V property. Please review attached 1/1 Permit.
V Manholes shall remain accessible at all times. Buried manholes will be corrected by the
The proper class of cleanout must be installed every 100 feet of lateral pipe measurer.,
All fees have been paid.
Plans have been submitted.
No other permits required.
_No manhole core permit required.
e�
No Certificate of Insurance required. P
Not a FOG FaCllity. 4'OnE npM��TON
By signing below, I attest that I am familiar with the District's specifications and agree to accept responsibility for all work done under this permit
BuilderlOwner Signature _ Phone Number 37 7 r q % i V—
Printed Name M e i'L V
Permit Date 7/5/2022
Approved By / , Permit is valid for ONE YEAR from the date issued. Permit valid
Ryan Hartman, Utility Engineer only with TriCo seal in red ink
nce is issues prior to occupancy/sale of
Printed Date