HomeMy WebLinkAbout42230036 - GR2 132 - Truss DetailsDE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Stark Truss Inc. 07/11/2022 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Indiana Residential Building Code 2020 based on IRC 2018 with Indiana specific amendments. 675 IAC 14-4.4-81 Section R802.10.1; truss design drawings, R802.10.1; truss design drawings shall be provided to the building official as required by the General Administrative Rules (675 IAC 12) for Class 1 structures or by local ordinance for Class 2 structures. Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2014 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 Job: 2208401-12T 25 truss design(s) 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x6 =4x6 =3x5 =4x8 =4x10 =3x4 =4x6 =3x4 =3x8 =1.5x4 =3x4 =4x10 =4x8 =3x5 =4x6 =3x6 33 34 35 36 18 17 29 30 16 31 32 15 14 13 12 11 1 10 2 9 4 5 6 24 25 7222321 26202719 283 8 T1 T2 T3 T1 W1 W1 B1 B2 W3 W4 W5 W4 W5 W4 W5 W4 W3 W2 W2 0-10-12 22-10-12 0-10-12 -0-10-12 1-5-8 1-5-8 1-5-8 22-0-0 4-8-6 20-6-8 4-8-6 6-1-14 4-10-2 11-0-0 4-10-2 15-10-2 1-3-12 1-3-12 1-3-12 22-0-0 4-10-2 20-8-4 4-10-2 6-1-14 4-10-2 15-10-2 4-10-2 11-0-02-3-141-4-30-1-4 2-2-102-2-100-1-42-3-14Scale = 1:44.2 Plate Offsets (X, Y):[2:0-2-14,0-2-0], [3:0-4-12,0-1-8], [8:0-4-12,0-1-8], [9:0-2-14,0-2-0], [13:0-3-8,0-2-0], [16:0-3-8,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.63 Vert(LL) -0.25 14 >999 360 MT20 197/144 Snow (Pf/Pg) 20.4/20.0 Lumber DOL 1.15 BC 0.82 Vert(CT) -0.38 14 >684 240 TCDL 10.0 Rep Stress Incr NO WB 0.94 Horz(CT) 0.06 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 90 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (2-9-4 max.): 3-8. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=881/0-6-0, (min. 0-1-13), 18=881/0-6-0, (min. 0-1-13) Max Horiz 18=86 (LC 11) Max Uplift 11=-420 (LC 8), 18=-420 (LC 9) Max Grav 11=1138 (LC 36), 18=1138 (LC 36) 1 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-859/337, 3-19=-2793/920, 19-20=-2794/920, 20-21=-2794/920, 4-21=-2795/920, 4-22=-3468/1117,22-23=-3468/1117, 5-23=-3468/1117, 5-6=-3468/1117, 6-24=-3468/1117, 24-25=-3468/1117, 7-25=-3468/1117,7-26=-2795/920, 26-27=-2794/920, 27-28=-2794/920, 8-28=-2793/920, 8-9=-859/337, 2-18=-1163/426, 9-11=-1163/426 BOT CHORD 17-29=-329/804, 29-30=-329/804, 16-30=-329/804, 16-31=-934/2793, 31-32=-934/2793, 15-32=-934/2793, 14-15=-934/2793, 14-33=-925/2793, 33-34=-925/2793, 13-34=-925/2793, 13-35=-309/800, 35-36=-309/800, 12-36=-309/800 WEBS 3-17=-602/230, 3-16=-666/2182, 4-16=-750/257, 4-14=-223/728, 6-14=-439/159, 7-14=-223/728, 7-13=-750/257, 8-13=-666/2182, 8-12=-602/230, 2-17=-387/1038, 9-12=-388/1038 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC1608.3.4. 4) Unbalanced snow loads have been considered for this design.5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 420 lb uplift at joint 18 and 420 lb uplift at joint 11. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 119 lb down and 132 lb up at 1-5-8, 69 lb down and 35 lb up at 3-0-0, 69lb down and 35 lb up at 5-0-0, 69 lb down and 35 lb up at 7-0-0, 69 lb down and 35 lb up at 9-0-0, 69 lb down and 35 lb up at 11-0-0, 69 lb down and 35 lb up at 13-0-0, 69lb down and 35 lb up at 15-0-0, 69 lb down and 35 lb up at 17-0-0, and 69 lb down and 35 lb up at 19-0-0, and 119 lb down and 132 lb up at 20-6-8 on top chord, and 32 lbdown and 50 lb up at 1-5-8, 23 lb down and 21 lb up at 3-0-0, 23 lb down and 21 lb up at 5-0-0, 23 lb down and 21 lb up at 7-0-0, 23 lb down and 21 lb up at 9-0-0, 23 lbdown and 21 lb up at 11-0-0, 23 lb down and 21 lb up at 13-0-0, 23 lb down and 21 lb up at 15-0-0, 23 lb down and 21 lb up at 17-0-0, and 23 lb down and 21 lb up at19-0-0, and 32 lb down and 50 lb up at 20-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 G01 1 12208401-12T Hip Girder Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:Vic_Yr?PF9E7FzijGkAh?SyS99x-?1rUzV8uJTxA1d10vi6lV8sUUmbBeTlTS4U4Tbyz82C Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 LOAD CASE(S) Standard 1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-3=-51, 3-8=-61, 8-9=-51, 9-10=-51, 11-18=-20 Concentrated Loads (lb) Vert: 3=31, 17=3, 14=1, 8=31, 12=3, 29=1, 30=1, 31=1, 32=1, 33=1, 34=1, 35=1, 36=1 Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 G01 1 12208401-12T Hip Girder Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 2 ID:Vic_Yr?PF9E7FzijGkAh?SyS99x-?1rUzV8uJTxA1d10vi6lV8sUUmbBeTlTS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =MT18HS 12x18 =10x10 =4x4 =6x8 =5x8 =10x10 =3x6 =8x8 =12x12 11 14 15 10 16 17 9 8 18 19 20 7 21 22 6 51 2 4 12 13 3 T1 T1 W1 W1 B1 B2 W5 W6 W7W4W3 W2 W8 5-4-0 5-4-0 5-4-0 22-0-0 5-8-0 16-8-0 5-8-0 11-0-0 4-7-13 22-0-0 5-4-0 5-4-0 5-8-0 11-0-0 6-4-3 17-4-31-4-38-8-3Scale = 1:45.7 Plate Offsets (X, Y):[1:Edge,0-11-0], [2:0-0-12,0-1-8], [5:0-6-0,0-11-8], [7:0-4-0,0-4-12], [8:0-5-0,0-6-4], [10:0-3-8,0-6-0] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.33 Vert(LL)-0.09 8-10 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.45 Vert(CT)-0.17 8-10 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr NO WB 0.81 Horz(CT)0.03 6 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 487 lb FT = 20% LUMBER TOP CHORD 2x6 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF Stud *Except* W5,W2,W8:2x4 SPF No.2, W1:2x8 SP 2400F2.0E BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)6=9894/0-6-0, (min. 0-2-12), 11=11492/0-6-0, (min. 0-3-3) Max Horiz 11=-232 (LC 10) Max Uplift 6=-1704 (LC 13), 11=-1970 (LC 12) Max Grav 6=9916 (LC 19), 11=11514 (LC 18) 3 3FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-13991/2397, 2-12=-9420/1682, 3-12=-9383/1704, 3-13=-9383/1706, 4-13=-9428/1684, 4-5=-11856/2034, 1-11=-9640/1685, 5-6=-8460/1481 BOT CHORD 11-14=-636/2768, 14-15=-636/2768, 10-15=-636/2768, 10-16=-2019/11518, 16-17=-2019/11518, 9-17=-2019/11518,8-9=-2019/11518, 8-18=-1566/9358, 18-19=-1566/9358, 19-20=-1566/9358, 7-20=-1566/9358, 7-21=-382/2061,21-22=-382/2061, 6-22=-382/2061 WEBS 3-8=-1714/9933, 4-8=-1965/501, 4-7=-391/2436, 2-8=-4667/946, 2-10=-857/5254, 1-10=-1467/8917, 5-7=-1288/7895 NOTES 1)3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 4 rows staggered at 0-5-0 oc. Web connected as follows: 2x4 - 1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3)Unbalanced roof live loads have been considered for this design. 4)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10 6)Unbalanced snow loads have been considered for this design. 7)All plates are MT20 plates unless otherwise indicated. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1970 lb uplift at joint 11 and 1704 lb uplift at joint 6. 10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1627 lb down and 272 lb up at 2-0-12, 1627 lb down and 272 lb up at4-0-12, 3289 lb down and 554 lb up at 5-5-4, 1667 lb down and 281 lb up at 6-0-12, 1667 lb down and 281 lb up at 8-0-12, 1666 lb down and 281 lb up at 10-0-12, 1666 lb down and 281 lb up at 12-0-12, 1666 lb down and 281 lb up at 14-0-12, 1666 lb down and 281 lb up at 16-0-12, and 1666 lb down and 281 lb up at 18-0-12, and 1667 lb down and 281 lb up at 20-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 G02 1 32208401-12T Common Girder Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:xc5jZdCci56B7onvebU4uaySC3c-TDPsAr8W4m30fnbCSQd_2LPjuA0BNy0chkEd01yz82B Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 LOAD CASE(S) Standard 1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-3=-51, 3-5=-51, 6-11=-20 Concentrated Loads (lb) Vert: 9=-1666, 10=-3289, 14=-1627, 15=-1627, 16=-1667, 17=-1667, 18=-1666, 19=-1666, 20=-1666, 21=-1666, 22=-1667 Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 G02 1 32208401-12T Common Girder Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 2 ID:xc5jZdCci56B7onvebU4uaySC3c-TDPsAr8W4m30fnbCSQd_2LPjuA0BNy0chkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =3x6 =3x6 =3x6 =3x6 =5x6 =3x6 =3x4 =3x6 =3x5 =3x4 =3x5 =4x6 =5x6 37 36 35 34 33 32 31 30 2928 27 2625 24 23 22 21 1 202 193 4 5550 5 6 1875451178 9 10 16 115212 13 145315 W1 T2 T1 T3 T4 T1 W1 B1 B1B2 W2 W5W3 W4 W6 W7 ST8ST8ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST8 ST7 ST9 ST10 ST4 ST11 ST12 ST1 0-10-12 -0-10-12 2-3-0 36-6-0 6-0-9 21-3-5 6-0-0 34-3-0 6-11-11 28-3-0 15-2-11 15-2-11 2-0-0 32-3-0 2-0-0 30-3-0 2-0-0 28-3-0 2-0-0 26-3-0 2-0-0 24-3-0 4-3-0 36-6-0 22-3-0 22-3-011-6-01-4-30-3-80-3-811-2-811-6-0Scale = 1:65.3 Plate Offsets (X, Y):[11:0-3-0,0-0-2], [15:0-4-8,0-2-8], [21:Edge,0-3-8], [29:0-2-4,0-1-8], [47:0-1-13,0-0-12], [49:0-1-13,0-0-12] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.66 Vert(LL)-0.06 22-23 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(CT)-0.12 22-23 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.26 Horz(CT)-0.01 24 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 248 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W2:2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* ST8,ST7,ST6,ST5:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 11-15. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except:10-0-0 oc bracing: 23-24,22-23,21-22. WEBS 1 Row at midpt 13-27, 12-28, 10-30, 9-31, 14-26, 16-24, 18-24 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 22-8-0. except 21=0-6-0 (lb) -Max Horiz 37=331 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 26, 27, 28, 32, 33, 34, 35 except 21=-119 (LC 16), 24=-348 (LC 17), 31=-107 (LC 16), 36=-234 (LC 16), 37=-160 (LC 49) Max Grav All reactions 250 (lb) or less at joint(s) 26, 27, 28, 31, 32, 33,34, 35, 37 except 21=471 (LC 41), 24=1095 (LC 51), 30=286(LC 41), 36=360 (LC 49) 5 5FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-202/315, 5-50=-26/274, 5-6=0/272, 8-51=0/273, 8-9=-8/296, 9-10=-38/344, 10-11=-63/280, 11-52=-51/274,12-52=-51/274, 12-13=-51/274, 13-14=-51/274, 14-53=-51/274, 15-53=-51/274, 15-16=-99/299, 16-17=-60/421,18-55=-328/211, 19-55=-388/192, 19-20=-459/169, 20-21=-329/111 BOT CHORD 36-37=-342/239, 35-36=-342/239, 34-35=-342/239, 33-34=-342/239, 32-33=-342/239, 31-32=-342/239, 30-31=-342/239,29-30=-342/239, 28-29=-342/239, 27-28=-342/239, 26-27=-342/239, 25-26=-342/239, 24-25=-342/239, 23-24=-105/311,22-23=-121/332, 21-22=-121/332 WEBS 16-24=-510/192, 18-23=0/305, 18-24=-667/279 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) -0-10-12 to 2-9-1, Exterior(2N) 2-9-1 to 15-2-11, Corner(3R) 15-2-11 to 18-10-8, Exterior(2N) 18-10-8 to 21-3-5, Corner(3R) 21-3-5 to 24-11-1, Exterior(2N) 24-11-1 to 36-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consultqualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Provide adequate drainage to prevent water ponding. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10)Gable studs spaced at 2-0-0 oc. Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE01 1 12208401-12T Piggyback Base Supported Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:tPAXcVFKJHU7LA2UBZQWSZySD2p-TDPsAr8W4m30fnbCSQd_2LPekA0tN4dchkEd01yz82B Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 27, 28, 32, 33, 34, 35, 26 except (jt=lb) 37=160, 21=118, 31=106, 36=234, 24=348. 13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE01 1 12208401-12T Piggyback Base Supported Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 2 ID:tPAXcVFKJHU7LA2UBZQWSZySD2p-TDPsAr8W4m30fnbCSQd_2LPekA0tN4dchkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =6x6 =5x6 =3x5 =3x6 =3x8 =8x8 =2x4 =3x6 =3x4 =3x6 =8x8 =3x8 =3x6 =3x5 =5x6 =6x6 =3x4 19 18 17 16 15 14 13 12 11 1 102 34 41 4035 93393648 5 37 6 38 7 T2 T1 T3 T4 T1 W1 W10B1B1B2 W3 W4 W5 W6 W6 W5 W7 W8 W2 W9 ST8 ST7ST6ST5 ST4 ST3 ST1 ST2 0-10-12 -0-10-12 4-3-5 19-0-0 4-3-5 23-3-5 7-5-6 14-8-11 7-5-10 30-8-14 7-3-5 7-3-5 7-9-2 38-6-0 7-3-5 7-3-5 7-3-10 14-6-15 7-4-5 38-6-0 7-8-11 31-1-11 8-10-1 23-5-11-8-31-4-311-6-0Scale = 1:67.2 Plate Offsets (X, Y):[2:0-3-0,0-3-13], [4:0-2-8,Edge], [5:0-5-12,0-2-0], [7:0-5-12,0-2-0], [10:0-3-0,0-1-8], [11:Edge,0-1-8], [32:0-1-9,0-0-12] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.82 Vert(LL)-0.14 13-16 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.63 Vert(CT)-0.31 13-16 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.71 Horz(CT)0.06 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 241 lb FT = 20% LUMBER TOP CHORD 2x4 SPF 1650F 1.5E *Except* T3:2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4,W5,W6,W7:2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* ST8,ST7:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-11 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 9-11-7 oc bracing. WEBS 1 Row at midpt 3-16, 6-16, 6-13, 9-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)11=1390/ Mechanical, (min. 0-1-8), 18=150/2-6-0, (min. 0-2-12), 19=1304/2-6-0, (min. 0-2-12) Max Horiz 19=330 (LC 13) Max Uplift 11=-272 (LC 17), 19=-347 (LC 16) Max Grav 11=1682 (LC 41), 18=264 (LC 7), 19=1591 (LC 41) 7 7FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-34=-2112/325, 34-35=-2023/327, 3-35=-1884/349, 3-36=-1849/320, 4-36=-1795/322, 4-5=-1637/358, 5-37=-1352/374, 6-37=-1352/374, 6-38=-1374/377, 7-38=-1374/377, 7-8=-1663/365, 8-39=-1828/329, 9-39=-1877/328, 9-40=-2001/350, 40-41=-2132/329, 10-41=-2240/326, 2-19=-1663/328, 10-11=-1612/303 BOT CHORD 18-19=-350/372, 17-18=-350/372, 16-17=-330/1683, 15-16=-171/1369, 14-15=-171/1369, 13-14=-171/1369, 12-13=-201/1794 WEBS 3-16=-491/292, 5-16=-86/510, 6-16=-291/224, 7-13=-87/525, 9-13=-595/308, 2-17=-120/1630, 10-12=-126/1646 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-11-7, Interior (1) 2-11-7 to 14-8-11, Exterior(2R) 14-8-11 to 20-2-1, Interior (1) 20-2-1 to 23-3-5, Exterior(2R) 23-3-5 to 28-8-10, Interior (1) 28-8-10 to 38-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consultqualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Provide adequate drainage to prevent water ponding. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.11)Refer to girder(s) for truss to truss connections. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 347 lb uplift at joint 19 and 272 lb uplift at joint 11. 13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE02 1 12208401-12T Piggyback Base Structural Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:KUWvs1D8WYGp9LzUmOHucEySCyO-?1rUzV8uJTxA1d10vi6lV8sRWme9eWLTS4U4Tbyz82C Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE02 1 12208401-12T Piggyback Base Structural Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 2 ID:KUWvs1D8WYGp9LzUmOHucEySCyO-?1rUzV8uJTxA1d10vi6lV8sRWme9eWLTS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =3x5 =3x6 =5x6 =3x6 =3x6 =5x6 =3x6 =3x4 =3x4 49 48 47 46 45 44 43 42 41 40 39 38 37 3635 34 33 32 31 30 29 28 27 1 262325 4 24 5550523 6 22 5451721 8 20 9 191018 1112 1352 14 5315 1617 W1 T2 T1 T3 T4 T1 W2 B1 B1B2 ST1 ST2 ST3 ST4 ST5 ST6 ST7 ST8 ST8 ST8 ST8 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 0-10-12 -0-10-12 8-6-9 23-3-5 14-8-11 14-8-11 15-2-11 38-6-0 38-6-01-8-31-4-311-6-0Scale = 1:67.2 Plate Offsets (X, Y):[11:0-4-8,0-2-8], [17:0-4-8,0-2-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.17 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.18 Horz(CT)0.01 27 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 254 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF No.2 *Except* ST1,ST2,ST3,ST4:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 11-17. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-43, 10-42, 12-41, 13-39, 14-38, 15-37, 16-35, 18-34, 20-33 MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide. REACTIONS All bearings 38-6-0. (lb) -Max Horiz 49=330 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 29, 30, 31, 32, 33, 34, 37, 38, 39, 42, 43, 44, 45, 46, 47 except 27=-220 (LC 15), 28=-213 (LC 17), 48=-345 (LC 13), 49=-337 (LC 12) Max Grav All reactions 250 (lb) or less at joint(s) 29, 30, 31, 32, 33, 34,35, 37, 38, 39, 41, 42, 43, 44, 45, 46, 47 except 27=257 (LC14), 28=293 (LC 15), 48=391 (LC 14), 49=381 (LC 13) 9 9FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 7-8=-178/298, 8-9=-218/364, 9-10=-204/367, 10-11=-245/413, 11-12=-212/371, 12-13=-212/371, 13-52=-212/371,14-52=-212/371, 14-53=-212/371, 15-53=-212/371, 15-16=-212/371, 16-17=-212/371, 17-18=-245/413, 18-19=-200/367,19-20=-218/364, 20-21=-178/298 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) -0-10-12 to 3-0-0, Exterior(2N) 3-0-0 to 14-8-11, Corner(3R) 14-8-11 to 18-6-15, Exterior(2N) 18-6-15 to 23-3-5, Corner(3R) 23-3-5 to 27-0-0, Exterior(2N) 27-0-0 to 38-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Provide adequate drainage to prevent water ponding. 8)All plates are 1.5x4 MT20 unless otherwise indicated.9)Gable requires continuous bottom chord bearing. 10)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 11)Gable studs spaced at 2-0-0 oc. 12)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 13)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 47, 46, 45, 44, 43, 42, 39, 38, 37, 34, 33, 32, 31, 30, 29 except (jt=lb) 49=336, 27=219, 48=345, 28=213. Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE03 1 12208401-12T Piggyback Base Supported Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:M9iltz8lbdDSeqTHBpqU4aySD6p-TDPsAr8W4m30fnbCSQd_2LPkCA5YN6schkEd01yz82B Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 14)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE03 1 12208401-12T Piggyback Base Supported Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 2 ID:M9iltz8lbdDSeqTHBpqU4aySD6p-TDPsAr8W4m30fnbCSQd_2LPkCA5YN6schkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =3x4 =4x4 =3x4 =3x4 20 19 18 17 16 15 14 13 12 1 11 2 10 3 9 21 22 4 8 5 7 6 W1 T1 T1 W1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 0-10-12 -0-10-12 0-10-12 15-2-12 7-2-0 14-4-0 7-2-0 7-2-0 14-4-01-4-36-1-8Scale = 1:34.1 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.14 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.15 Horz(CT)0.00 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 67 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 14-4-0. (lb) -Max Horiz 20=191 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 14, 15, 17, 18 except 12=-122 (LC 13), 13=-126 (LC 12), 19=-141 (LC 13), 20=-142 (LC 12) Max Grav All reactions 250 (lb) or less at joint(s) 12, 13, 14, 15, 16, 17, 18, 19, 20 11 11FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-126/276, 6-7=-126/276 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) -0-10-12 to 2-1-4, Exterior(2N) 2-1-4 to 7-2-0, Corner(3R) 7-2-0 to 10-2-0, Exterior(2N) 10-2-0 to 15-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consultqualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)All plates are 1.5x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 15, 14 except (jt=lb) 20=141, 12=121, 19=140,13=126. 13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 GE04 1 12208401-12T Common Supported Gable Job Reference (optional) Run: 8.53 S Jan 25 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:ejkvU36mXyj1njoNrONlqazkYdw-TDPsAr8W4m30fnbCSQd_2LPmsA6zN6KchkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x6 =3x4 =3x4 1 5 4 2 3 W1 T1 W2 B1 0-10-12 -0-10-12 2-0-0 2-0-0 0-1-8 2-0-0 1-10-8 1-10-82-3-60-8-112-0-11Scale = 1:24.7 Plate Offsets (X, Y):[4:Edge,0-2-0], [5:0-3-12,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.14 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.04 Vert(CT)0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT)n/a -n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 8 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)4=44/ Mechanical, (min. 0-1-8), 5=130/0-4-0, (min. 0-1-8) Max Horiz 5=66 (LC 16) Max Uplift 4=-42 (LC 16), 5=-23 (LC 16) Max Grav 4=58 (LC 23), 5=184 (LC 23) 12 12FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left exposed ; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 23 lb uplift at joint 5 and 42 lb uplift at joint 4. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 J01 4 12208401-12T Jack-Closed Job Reference (optional) Run: 8.51 S Oct 22 2021 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:hQLrac2tkX3KETUOoZ?5dZyT7Y_-3ejkYp6eorhSoKtdnH4HQjnFdz5vAnxA?m?zPjyz82E WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 8 12 =3x4 =3x4 5 4 1 2 3 W1 T1 B1 0-10-12 -0-10-12 1-5-8 1-5-8 1-5-82-3-141-4-32-3-14Scale = 1:21.7 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.20 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(CT)0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horz(CT)-0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 6 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-5-8 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS (lb/size)3=16/ Mechanical, (min. 0-1-8), 4=9/ Mechanical, (min. 0-1-8), 5=120/0-6-0, (min. 0-1-8) Max Horiz 5=59 (LC 13) Max Uplift 3=-41 (LC 16), 4=-15 (LC 16), 5=-1 (LC 16) Max Grav 3=33 (LC 30), 4=28 (LC 14), 5=168 (LC 23) 13 13FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1 lb uplift at joint 5, 15 lb uplift at joint 4 and 41 lb uplift at joint 3. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 J02 11 12208401-12T Jack-Open Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:CI?cTq5UIIXMR7Ra?nPcuLySDJo-?1rUzV8uJTxA1d10vi6lV8saBmmaehQTS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 5.6612 =3x4 =3x4 5 4 1 2 3 W1 T1 B1 1-3-3 -1-3-3 1-11-4 1-11-4 1-11-42-3-21-4-32-3-20-9-0Scale = 1:21.6 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.18 Vert(LL)0.00 4-5 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.05 Vert(CT)0.00 4-5 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.00 Horz(CT)-0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 7 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 1-11-4 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS (lb/size)3=-6/ Mechanical, (min. 0-1-8), 4=-1/ Mechanical, (min. 0-1-8), 5=112/0-8-2, (min. 0-1-8) Max Horiz 5=60 (LC 11) Max Uplift 3=-58 (LC 16), 4=-14 (LC 11), 5=-40 (LC 12) Max Grav 3=32 (LC 8), 4=20 (LC 7), 5=176 (LC 19) 14 14FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 40 lb uplift at joint 5, 14 lb uplift at joint 4 and 58 lb uplift at joint 3. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51 Trapezoidal Loads (lb/ft) Vert: 2=-2 (F=24, B=24)-to-3=-25 (F=13, B=13), 5=0 (F=10, B=10)-to-4=-10 (F=5, B=5) Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 J03 2 12208401-12T Diagonal Hip Girder Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:GoZq0qVtlEGm_6u3Ms0280ySDHz-?1rUzV8uJTxA1d10vi6lV8sbVmnCehQTS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 14.4212 =3x4 =3x4 =4x4 =3x4 1 11 21 20 19 1817 16 15 14 13 12 102 93 84 2726 75 6 T1 T1 B1 B2 ST5 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST1 0-2-13 18-10-3 9-2-4 18-7-6 9-5-2 9-5-2 18-10-311-4-30-0-411-0-8Scale = 1:52.5 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.16 Horiz(TL)0.01 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 110 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud *Except* ST5,ST4:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16, 5-17, 7-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS All bearings 18-10-3. (lb) -Max Horiz 1=-318 (LC 12) Max Uplift All uplift 100 (lb) or less at joint(s) 11, 12, 16, 21 except 1=-175 (LC 14), 13=-185 (LC 17), 14=-168 (LC 17), 15=-165 (LC 17), 17=-167 (LC 16), 19=-168 (LC 16), 20=-182 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 11, 12, 13, 14, 15, 17, 19, 20, 21 except 1=289 (LC 16), 16=283 (LC 17) 15 15FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-448/288, 2-3=-344/244, 9-10=-303/198, 10-11=-402/284 BOT CHORD 1-21=-205/300, 20-21=-205/300, 19-20=-205/300, 18-19=-205/300, 17-18=-205/300, 16-17=-205/300, 15-16=-205/300, 14-15=-205/300, 13-14=-205/300, 12-13=-205/300, 11-12=-205/300 WEBS 6-16=-262/200 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) 0-0-3 to 3-0-3, Interior (1) 3-0-3 to 9-5-5, Exterior(2R) 9-5-5 to 12-5-5, Interior (1) 12-5-5 to 18-10-7 zone; cantilever left and right exposed ; end vertical left andright exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 1.5x4 MT20 unless otherwise indicated. 6)Gable requires continuous bottom chord bearing.7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 16, 21, 12 except (jt=lb) 1=174, 17=167, 19=167, 20=182, 15=164, 14=167, 13=184. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 LAY01 1 12208401-12T Lay-In Gable Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:e4?St7oYQCJeNTkokM2AHfzs7gO-TDPsAr8W4m30fnbCSQd_2LPnpA6oN6BchkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 8 12 =3x4 =4x4 =1.5x4 =3x4 1 5 6 2 4 3 T1 T1 B1 ST1 0-8-12 5-11-13 0-8-12 0-8-12 2-3-3 5-3-1 2-3-3 2-11-15 4-6-52-0-30-4-7 0-1-10-0-1-101-10-91-10-9Scale = 1:20.4 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.06 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.02 Horz(CT)n/a -n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 15 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 4-6-5. (lb) -Max Horiz 2=-50 (LC 14), 7=-50 (LC 14) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 4, 6, 7, 11 Max Grav All reactions 250 (lb) or less at joint(s) 2, 4, 6, 7, 11 16 16FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plategrip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design.6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 4-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4, 6, 2, 4. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 P01 4 12208401-12T Piggyback Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:lU3mhEjgxsvz0xcfv5jLQBySD9y-?1rUzV8uJTxA1d10vi6lV8sdOmn3eh7TS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =1.5x4 =1.5x4 =4x4 =1.5x4 =1.5x4 =1.5x4 =3x4 71 10 9 8 62 53 17 18 4 T1 T1 B1 ST2 ST1 ST1 0-8-12 8-5-13 0-8-12 0-8-12 3-6-3 7-9-1 3-6-3 4-2-15 7-0-52-10-30-4-7 0-1-10-0-1-102-8-92-8-9Scale = 1:23.1 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT)0.00 6 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 24 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 7-0-5. (lb) -Max Horiz 2=72 (LC 15), 11=72 (LC 15) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 6, 8, 10, 11, 14 Max Grav All reactions 250 (lb) or less at joint(s) 2, 6, 8, 9, 10, 11, 14 17 17FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) 0-3-5 to 3-3-5, Exterior(2N) 3-3-5 to 4-3-5, Corner(3R) 4-3-5 to 7-4-9, Exterior(2N) 7-4-9 to 8-3-4 zone; cantilever left and right exposed ; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design.6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 10, 8, 2, 6. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 P02 2 12208401-12T Piggyback Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:JOX5ge?9h1gl8WUco2ipLyySDDS-TDPsAr8W4m30fnbCSQd_2LPo7A7lN7achkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =1.5x4 =4x4 =3x4 51 6 42 1514 3 T1 T1 B1 ST1 0-8-12 0-8-12 0-8-12 8-5-13 3-6-3 4-2-15 3-6-3 7-9-1 7-0-52-10-30-4-7 0-1-10-0-1-102-8-92-8-9Scale = 1:23.1 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.17 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.18 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.02 Horz(CT)0.00 2 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 22 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 7-0-5. (lb) -Max Horiz 2=-72 (LC 14), 7=-72 (LC 14) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 4, 6, 7, 11 Max Grav All reactions 250 (lb) or less at joint(s) 2, 4, 6, 7, 11 18 18FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) 0-3-5 to 3-3-5, Exterior(2N) 3-3-5 to 4-3-5, Corner(3R) 4-3-5 to 7-4-9, Exterior(2N) 7-4-9 to 8-3-4 zone; cantilever left and right exposed ; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design.6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 4-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4, 6, 2, 4. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 P03 8 12208401-12T Piggyback Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:aeQ2yInRWif7ks3pGMqlgSySD9s-?1rUzV8uJTxA1d10vi6lV8sbfmlAeh7TS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =6x8 =5x6 =3x5 =3x6 =3x4 =5x8 =3x6 =3x6 =5x8 =3x8 =3x6 =3x5 =5x6 =6x6 =3x4 17 16 15 14 13 12 11 10 1 92 18 28 2719 83 4 2620721 52223 24256 T2 T1 T3 T4 T1 W1 W1B1B1B2 W3 W4 W5 W6 W5 W4 W3 W2 W2 0-10-12 -0-10-12 6-0-9 21-3-5 7-8-9 36-6-0 7-6-3 28-9-7 7-6-3 15-2-11 7-8-9 7-8-9 6-4-1 21-5-1 7-4-5 36-6-0 7-4-5 7-4-5 7-8-11 29-1-11 7-8-11 15-0-1511-6-01-4-30-3-80-3-811-2-811-6-0Scale = 1:65.3 Plate Offsets (X, Y):[2:Edge,0-4-2], [5:0-5-8,0-1-12], [6:0-5-8,0-1-12], [9:Edge,0-1-12], [10:Edge,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL)-0.10 15-16 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.58 Vert(CT)-0.22 15-16 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.70 Horz(CT)0.06 10 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 184 lb FT = 20% LUMBER TOP CHORD 2x4 SPF 1650F 1.5E *Except* T3:2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4,W5,W6:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (3-2-2 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 9-8-11 oc bracing. WEBS 1 Row at midpt 3-15, 5-12, 8-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)10=1311/ Mechanical, (min. 0-1-8), 17=1366/0-6-0, (min.0-2-11) Max Horiz 17=331 (LC 13) Max Uplift 10=-262 (LC 17), 17=-289 (LC 16) Max Grav 10=1647 (LC 41), 17=1702 (LC 41) 19 19FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-18=-2195/311, 18-19=-2097/316, 3-19=-1957/338, 3-4=-1816/311, 4-20=-1754/314, 20-21=-1695/320, 5-21=-1599/349, 5-22=-1322/365, 22-23=-1322/365, 23-24=-1322/365, 24-25=-1322/365, 6-25=-1322/365, 6-7=-1601/350, 7-26=-1709/315, 8-26=-1818/312, 8-27=-1957/334, 27-28=-2091/313, 9-28=-2194/310, 2-17=-1633/319, 9-10=-1579/292 BOT CHORD 16-17=-364/469, 15-16=-331/1750, 14-15=-143/1321, 13-14=-143/1321, 12-13=-143/1321, 11-12=-189/1756 WEBS 3-15=-602/303, 5-15=-127/525, 6-12=-96/498, 8-12=-609/307, 2-16=-82/1565, 9-11=-113/1617 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-9-1, Interior (1) 2-9-1 to 15-2-11, Exterior(2R) 15-2-11 to 20-4-11, Interior (1) 20-4-11 to 21-3-5, Exterior(2R) 21-3-5 to 26-5-4, Interior (1) 26-5-4 to 36-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Refer to girder(s) for truss to truss connections. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 289 lb uplift at joint 17 and 262 lb uplift at joint 10. 10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T01 3 12208401-12T Piggyback Base Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:seaK8FBYFbezg2wyHfVc13ySC4v-?1rUzV8uJTxA1d10vi6lV8sQ1mexeXVTS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x5 =6x6 =4x6 =3x5 =3x6 =3x6 =3x8 =6x8 =3x4 =8x8 =3x8 =3x6 =3x6 =3x5 =4x6 =6x6 =3x5 18 17 1615 14 13 12 11 1 102 19 27 20 26 9325214228 5 23 6 24 7 T2 T1 T3 T4 T1 W1 W10B1B1B2 W3 W4 W5 W6 W6 W5 W7 W8 W2 W9 0-10-12 -0-10-12 4-3-5 19-0-0 4-3-5 23-3-5 7-2-10 14-8-11 7-5-10 30-8-14 7-6-2 7-6-2 7-9-2 38-6-0 7-0-14 14-6-15 7-3-14 30-8-14 7-6-2 7-6-2 7-9-2 38-6-0 8-10-1 23-5-11-8-31-4-311-6-0Scale = 1:67.2 Plate Offsets (X, Y):[2:0-3-0,0-3-13], [5:0-5-8,0-1-12], [7:0-5-12,0-2-0], [10:Edge,0-1-12], [11:Edge,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.80 Vert(LL)-0.15 14-15 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.62 Vert(CT)-0.33 14-15 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.41 Horz(CT)0.06 11 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 202 lb FT = 20% LUMBER TOP CHORD 2x4 SPF 1650F 1.5E *Except* T3:2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* W3,W8,W1,W10:2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-8 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 9-11-9 oc bracing. WEBS 1 Row at midpt 3-15, 6-15, 6-14, 9-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)11=1394/ Mechanical, (min. 0-1-8), 18=1450/0-6-0, (min.0-2-12) Max Horiz 18=330 (LC 13) Max Uplift 11=-271 (LC 17), 18=-293 (LC 16) Max Grav 11=1687 (LC 41), 18=1750 (LC 41) 20 20FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-19=-2151/311, 19-20=-2053/314, 3-20=-1912/337, 3-21=-1854/321, 4-21=-1812/321, 4-22=-1763/325, 5-22=-1647/358, 5-23=-1360/370, 6-23=-1360/370, 6-24=-1380/375, 7-24=-1380/375, 7-8=-1670/363, 8-25=-1836/326, 9-25=-1885/325, 9-26=-2022/352, 26-27=-2153/331, 10-27=-2262/328, 2-18=-1678/324, 10-11=-1612/304 BOT CHORD 17-18=-343/423, 16-17=-314/1708, 15-16=-314/1708, 14-15=-169/1377, 13-14=-197/1805, 12-13=-197/1805 WEBS 3-15=-522/283, 5-15=-88/524, 6-15=-288/225, 6-14=-251/227, 7-14=-86/531, 9-14=-601/305, 2-17=-111/1591, 10-12=-133/1660 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-11-7, Interior (1) 2-11-7 to 14-8-11, Exterior(2R) 14-8-11 to 20-2-1, Interior (1) 20-2-1 to 23-3-5, Exterior(2R) 23-3-5 to 28-8-10, Interior (1) 28-8-10 to 38-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Refer to girder(s) for truss to truss connections. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 293 lb uplift at joint 18 and 271 lb uplift at joint 11. 10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T02 3 12208401-12T Piggyback Base Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:o70RxlqRIQ6ViGx8KyC9mHySCyv-?1rUzV8uJTxA1d10vi6lV8sRpmeIeb1TS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =4x6 =3x6 =6x8=4x8 =3x5 =3x6 =6x12 =4x8 =6x8 =6x6 =3x8 =1.5x4 =3x6 =MT18HS 5x12 =3x6 =3x5 =4x6 =6x6 24 23 19 18 17 1615 14 13 1 21 2022 122 3 25 32 3126 11 30452710 6 7 28 8 29 9 T2 T1 T3 W1 W16 T4 T1 B1 B5 B6 B2 B3 B4 W5 W6 W7 W15W3 W2 W12 W11 W13 W14 W11 W12 W10 W9 W11 W4 W8 0-5-30-8-12 14-8-12 0-10-12 -0-10-12 2-6-15 2-6-15 4-3-5 19-0-0 4-3-5 23-3-5 5-8-1 8-3-0 5-9-0 14-0-0 7-5-10 30-8-14 7-9-2 38-6-0 0-6-9 23-1-9 0-10-7 14-10-8 2-6-0 2-6-0 3-7-0 22-7-0 4-1-9 19-0-0 5-9-0 8-3-0 5-9-0 14-0-0 7-7-6 30-8-14 7-9-2 38-6-01-8-31-4-31-0-011-6-0Scale = 1:67.2 Plate Offsets (X, Y):[2:0-2-14,0-2-0], [3:0-1-4,0-2-0], [7:0-5-8,0-1-12], [9:0-8-0,0-1-8], [12:Edge,0-1-12], [13:Edge,0-1-8], [18:0-3-0,0-1-8], [20:0-2-0,0-2-12], [22:0-2-4,0-3-4] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.79 Vert(LL)-0.14 20-21 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.67 Vert(CT)-0.26 20-21 >999 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr YES WB 0.81 Horz(CT)0.17 13 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 256 lb FT = 20% LUMBER TOP CHORD 2x4 SPF 1650F 1.5E *Except* T2,T3:2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2:2x4 SPF Stud WEBS 2x4 SPF Stud *Except* W7,W15,W12,W11,W13,W9,W8:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-8 max.): 7-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:8-0-6 oc bracing: 21-226-0-0 oc bracing: 19-20. 1 Row at midpt 6-20WEBS1 Row at midpt 9-17, 11-15, 7-18, 7-17, 8-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)13=1393/ Mechanical, (min. 0-1-8), 24=1448/0-6-0, (min.0-2-12) Max Horiz 24=330 (LC 13) Max Uplift 13=-271 (LC 17), 24=-293 (LC 16) Max Grav 13=1686 (LC 41), 24=1748 (LC 41) 21 21FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2274/455, 3-25=-2444/377, 25-26=-2431/388, 4-26=-2224/409, 4-5=-2009/360, 5-27=-1973/361, 6-27=-1848/389, 6-7=-1691/484, 7-28=-1382/359, 8-28=-1382/359, 8-29=-1382/359, 9-29=-1382/359, 2-24=-1678/364, 12-13=-1613/303, 9-10=-1651/361, 10-30=-1816/324, 11-30=-1865/323, 11-31=-2024/351, 31-32=-2155/330, 12-32=-2263/327 BOT CHORD 3-22=-291/133, 21-22=-542/2033, 20-21=-330/1953, 18-19=-88/393, 17-18=-192/1359, 16-17=-90/1376, 15-16=-90/1376, 14-15=-196/1807 WEBS 3-21=-273/225, 4-21=-3/267, 4-20=-635/267, 12-14=-130/1665, 2-22=-339/1871, 22-24=-347/302, 9-17=-208/272,9-15=-128/522, 11-15=-616/301, 7-18=-890/154, 7-17=-201/290, 18-20=-173/1488, 7-20=-367/1526, 8-17=-430/166 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-11-7, Interior (1) 2-11-7 to 14-8-12, Exterior(2R) 14-8-12 to 20-2-1, Interior (1) 20-2-1 to 23-3-5, Exterior(2R) 23-3-5 to 28-8-10, Interior (1) 28-8-10 to38-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)All plates are MT20 plates unless otherwise indicated. 8)All plates are 3x4 MT20 unless otherwise indicated. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)Refer to girder(s) for truss to truss connections. 11)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 271 lb uplift at joint 13 and 293 lb uplift at joint 24. Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T03 5 12208401-12T Piggyback Base Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:D0zB9tN9RT_To6w6Koot_hyS9Fw-TDPsAr8W4m30fnbCSQd_2LPciAzkNy0chkEd01yz82B Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 12)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T03 5 12208401-12T Piggyback Base Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 2 ID:D0zB9tN9RT_To6w6Koot_hyS9Fw-TDPsAr8W4m30fnbCSQd_2LPciAzkNy0chkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =3x5 =3x5 =6x6 =3x4 =4x10 =1.5x4 =6x6 =3x5 =3x5 =3x4 13 12 11 10 9 8 1 7 2 6 14 19 416 1715 183 5 T1 T2 T1 W1 W1 B1 B2 W3 W4 W5 W4 W3 W2 W2 0-10-12 22-10-12 0-10-12 -0-10-12 3-5-8 3-5-8 3-5-8 22-0-0 7-6-8 11-0-0 7-6-8 18-6-8 3-3-12 3-3-12 3-3-12 22-0-0 7-8-4 18-8-4 7-8-4 11-0-03-7-141-4-30-1-13 3-6-13-6-10-1-133-7-14Scale = 1:44.1 Plate Offsets (X, Y):[3:0-3-5,Edge], [5:0-3-5,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.86 Vert(LL)-0.10 10 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.48 Vert(CT)-0.18 10-12 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.46 Horz(CT)0.03 8 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 92 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 *Except* T2:2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-1-14 oc purlins, except end verticals, and 2-0-0 oc purlins (3-3-7 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)8=897/0-6-0, (min. 0-1-10), 13=897/0-6-0, (min. 0-1-10) Max Horiz 13=121 (LC 15) Max Uplift 8=-177 (LC 12), 13=-177 (LC 13) Max Grav 8=1047 (LC 40), 13=1047 (LC 40) 23 23FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-14=-1190/206, 3-14=-1144/218, 3-15=-2162/416, 15-16=-2163/416, 4-16=-2164/416, 4-17=-2164/416,17-18=-2163/416, 5-18=-2162/416, 5-19=-1144/218, 6-19=-1190/206, 2-13=-1037/181, 6-8=-1037/183 BOT CHORD 11-12=-230/1011, 10-11=-230/1011, 9-10=-164/1010 WEBS 3-10=-295/1254, 4-10=-838/289, 5-10=-295/1254, 2-12=-180/1075, 6-9=-182/1075 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 3-5-8, Exterior(2R) 3-5-8 to 7-8-7, Interior (1) 7-8-7 to 18-6-8, Exterior(2E) 18-6-8 to 22-10-12 zone; cantilever left and rightexposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 177 lb uplift at joint 13 and 177 lb uplift at joint 8. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T04 1 12208401-12T Hip Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:?sz2?7HKzwwSos4sHDYmd5yS97?-TDPsAr8W4m30fnbCSQd_2LPbcA0jN1UchkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =6x6 =4x4 =6x6 =3x4 =3x8 =1.5x4 =6x6 =4x4 =6x6 =3x4 13 12 11 10 9 8 1 7 14 2126 15 20 16 19 417 183 5 T1 T2 T1 W1 W1 B1 B2 W3 W4 W5 W4 W3 W2 W2 0-10-12 22-10-12 0-10-12 -0-10-12 5-6-8 16-6-8 5-6-8 11-0-0 5-5-8 5-5-8 5-5-8 22-0-0 5-3-12 5-3-12 5-3-12 22-0-0 5-8-4 16-8-4 5-8-4 11-0-04-11-141-4-30-1-13 4-10-14-10-10-1-134-11-14Scale = 1:44.1 Plate Offsets (X, Y):[2:0-3-0,0-3-13], [3:0-3-5,Edge], [5:0-3-5,Edge], [6:0-3-0,0-3-13] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.61 Vert(LL)-0.05 10 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.30 Vert(CT)-0.09 10-12 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.36 Horz(CT)0.02 8 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 99 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-6-9 oc purlins, except end verticals, and 2-0-0 oc purlins (4-5-4 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)8=877/0-6-0, (min. 0-1-8), 13=877/0-6-0, (min. 0-1-8) Max Horiz 13=158 (LC 15) Max Uplift 8=-150 (LC 17), 13=-150 (LC 16) Max Grav 8=971 (LC 41), 13=971 (LC 41) 24 24FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-1112/157, 15-16=-1080/165, 3-16=-1035/183, 3-17=-1341/235, 4-17=-1344/235, 4-18=-1344/235, 5-18=-1341/235,5-19=-1035/183, 19-20=-1080/164, 6-20=-1112/157, 2-13=-922/204, 6-8=-922/204 BOT CHORD 12-13=-161/291, 11-12=-201/898, 10-11=-201/898, 9-10=-120/898 WEBS 3-10=-176/575, 4-10=-622/215, 5-10=-176/575, 2-12=-153/846, 6-9=-156/846 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 5-5-8, Exterior(2R) 5-5-8 to 9-8-7, Interior (1) 9-8-7 to 16-6-8, Exterior(2R) 16-6-8 to 20-9-7, Interior (1) 20-9-7 to 22-10-12zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 150 lb uplift at joint 13 and 150 lb uplift at joint 8. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T05 1 12208401-12T Hip Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:plpuhM9RZXX0_Akk8PrBgnyS97A-TDPsAr8W4m30fnbCSQd_2LPfWA3WN32chkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =3x6 =4x4 =3x8 =5x6 =3x4 =3x4 =5x6 =3x8 =4x4 =3x6 =3x4 14 13 12 11 10 1 9 2 8 15 221621 3 7 518 1917 204 6 T1 T2 T1 W1 W1 B1 B2 W4 W4 W2 W2 W5 W5 W3 W3 0-10-12 22-10-12 0-10-12 -0-10-12 3-6-8 11-0-0 3-6-8 14-6-8 3-2-6 3-2-6 3-2-6 22-0-0 4-3-2 7-5-8 4-3-2 18-9-10 7-3-12 7-3-12 7-3-12 22-0-0 7-4-8 14-8-46-3-141-4-30-1-13 6-2-16-2-10-1-136-3-14Scale = 1:44.2 Plate Offsets (X, Y):[4:0-3-0,0-2-3], [6:0-3-0,0-2-3] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.32 Vert(LL)-0.06 13-14 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.44 Vert(CT)-0.13 13-14 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.44 Horz(CT)0.03 10 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 107 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)10=857/0-6-0, (min. 0-1-12), 14=857/0-6-0, (min. 0-1-12) Max Horiz 14=194 (LC 15) Max Uplift 10=-170 (LC 17), 14=-170 (LC 16) Max Grav 10=1099 (LC 41), 14=1099 (LC 41) 25 25FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-1009/210, 4-17=-740/218, 17-18=-741/218, 5-18=-741/218, 5-19=-741/218, 19-20=-741/218, 6-20=-740/218,6-7=-1009/210, 2-14=-254/95, 8-10=-254/95 BOT CHORD 13-14=-200/802, 12-13=-148/852, 11-12=-148/852, 10-11=-103/802 WEBS 4-13=-23/297, 6-11=-22/297, 3-14=-1076/186, 7-10=-1076/186 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 7-5-8, Exterior(2R) 7-5-8 to 11-8-7, Interior (1) 11-8-7 to 14-6-8, Exterior(2R) 14-6-8 to 18-10-15, Interior (1) 18-10-15 to22-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 170 lb uplift at joint 14 and 170 lb uplift at joint 10. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T06 1 12208401-12T Hip Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:Pd3vwiiDHAtG2UPdT8hWg_yS97l-?1rUzV8uJTxA1d10vi6lV8sZKmh7ebZTS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x5 =3x8 =4x4 =3x8 =5x6 =3x6 =6x6 =3x4 =4x4 =3x8 =3x5 13 12 11 10 9 1 8 72 14 21 2015 631916 1817 54 T1 T2 T1 W1 W1 B1 B2 W3 W4 W5 W4 W3W2 W2 0-10-12 22-10-12 0-10-12 -0-10-12 3-1-0 12-6-8 4-7-0 9-5-8 4-7-0 17-1-8 4-10-8 22-0-0 4-10-8 4-10-8 3-4-8 12-8-4 9-3-12 22-0-0 9-3-12 9-3-127-7-141-4-30-1-13 7-6-17-6-10-1-137-7-14Scale = 1:44.2 Plate Offsets (X, Y):[4:0-3-0,0-2-3], [5:0-3-5,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.46 Vert(LL)-0.20 9-10 >999 360 MT20 197/144 Snow (Pf/Pg)20.4/20.0 Lumber DOL 1.15 BC 0.63 Vert(CT)-0.40 9-10 >656 240 TCDL 10.0 Rep Stress Incr YES WB 0.87 Horz(CT)0.03 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 111 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4,W5:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-3-7 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)9=837/0-6-0, (min. 0-1-15), 13=837/0-6-0, (min. 0-1-15) Max Horiz 13=-230 (LC 14) Max Uplift 9=-185 (LC 17), 13=-185 (LC 16) Max Grav 9=1226 (LC 41), 13=1226 (LC 41) 26 26FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-14=-322/92, 3-16=-1082/186, 16-17=-1059/198, 4-17=-948/212, 4-5=-789/224, 5-18=-948/218, 18-19=-1058/203,6-19=-1082/192, 7-21=-322/92, 2-13=-414/146, 7-9=-414/146 BOT CHORD 12-13=-185/960, 11-12=-30/789, 10-11=-30/789, 9-10=-99/960 WEBS 3-12=-261/207, 4-12=-57/282, 5-10=-74/304, 6-10=-261/207, 3-13=-1073/148, 6-9=-1072/145 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 9-5-8, Exterior(2E) 9-5-8 to 12-6-8, Exterior(2R) 12-6-8 to 16-9-7, Interior (1) 16-9-7 to 22-10-12 zone; cantilever left andright exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=20.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10, Lu=50-0-0; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC1608.3.4. 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)Provide adequate drainage to prevent water ponding. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 185 lb uplift at joint 13 and 185 lb uplift at joint 9. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T07 1 12208401-12T Hip Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:axfnX1D7htrxFKLx7kz82YyS98N-TDPsAr8W4m30fnbCSQd_2LPhsA_NNx4chkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x5 =3x8 =4x4 =MT18HS 3x10 =4x4 =3x8 =4x4 =3x8 =3x5 11 10 9 8 1 7 62 3 5 12 15 13 14 4 T1 T1 W1 W1 B1 B2 W2 W2 W4 W3 W3 0-10-12 -0-10-12 0-10-12 22-10-12 5-4-4 11-0-0 5-4-4 16-4-4 5-7-12 5-7-12 5-7-12 22-0-0 11-0-0 11-0-0 11-0-0 22-0-01-4-38-8-3Scale = 1:47.9 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL)-0.27 9-11 >958 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.99 Vert(CT)-0.55 9-11 >475 240 MT18HS 197/144 TCDL 10.0 Rep Stress Incr YES WB 0.81 Horz(CT)0.03 8 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 101 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS (lb/size)8=821/0-6-0, (min. 0-1-8), 11=821/0-6-0, (min. 0-1-8) Max Horiz 11=-260 (LC 14) Max Uplift 8=-193 (LC 17), 11=-193 (LC 16) Max Grav 8=931 (LC 2), 11=931 (LC 2) 27 27FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-323/139, 3-12=-818/208, 12-13=-736/219, 4-13=-719/236, 4-14=-719/236, 14-15=-736/219, 5-15=-818/208, 5-6=-322/138, 2-11=-355/174, 6-8=-355/174 BOT CHORD 10-11=-204/818, 9-10=-204/818, 8-9=-115/746 WEBS 3-11=-763/148, 5-8=-763/148, 4-9=-111/542, 3-9=-254/254, 5-9=-255/255 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-10-12 to 2-1-4, Interior (1) 2-1-4 to 11-0-0, Exterior(2R) 11-0-0 to 14-0-0, Interior (1) 14-0-0 to 22-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design.5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)All plates are MT20 plates unless otherwise indicated. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 193 lb uplift at joint 11 and 193 lb uplift at joint 8. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 T08 2 12208401-12T Common Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:2a9JclpRTkgdnGKbhJtODayS98u-TDPsAr8W4m30fnbCSQd_2LPgxAukNy0chkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =1.5x4 =1.5x4 =3x4 =1.5x4 =4x4 =1.5x4 =1.5x4 =3x4 51 9 8 7 6 42 1514 3 T1 T1 B1 B2 ST2 ST1 ST1 0-5-3 18-5-4 8-9-7 18-0-1 9-2-10 9-2-10 18-5-46-2-00-0-45-10-5Scale = 1:37.5 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.28 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.20 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.20 Horiz(TL)0.00 5 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 58 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 18-5-4. (lb) -Max Horiz 1=-162 (LC 12) Max Uplift All uplift 100 (lb) or less at joint(s) 1 except 6=-225 (LC 17), 9=-225 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 1, 5 except 6=482 (LC30), 7=330 (LC 2), 9=465 (LC 29) 28 28FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-7=-282/6, 2-9=-336/246, 4-6=-344/246 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Interior (1) 3-5-12 to 9-3-0, Exterior(2R) 9-3-0 to 12-3-0, Interior (1) 12-3-0 to 18-5-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=225, 6=225. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 V01 1 12208401-12T Valley Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:f2hFU_eTxDOe386A5w35EDySD6A-TDPsAr8W4m30fnbCSQd_2LPkgA44N5YchkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =1.5x4 =1.5x4 =1.5x4 =4x4 =1.5x4 =1.5x4 =3x4 51 8 7 6 42 1413 3 T1 T1 B1 ST2 ST1 ST1 0-5-3 14-5-4 6-9-7 14-0-1 7-2-10 7-2-10 14-5-44-10-00-0-44-6-5Scale = 1:31.1 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.23 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.09 Horiz(TL)0.00 5 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 44 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 14-5-4. (lb) -Max Horiz 1=-126 (LC 12) Max Uplift All uplift 100 (lb) or less at joint(s) 1, 5 except 6=-171 (LC 17), 8=-173 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 1, 5 except 6=384 (LC23), 7=284 (LC 2), 8=368 (LC 22) 29 29FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-297/202, 4-6=-304/201 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-5-12 to 3-3-0, Interior (1) 3-3-0 to 7-3-0, Exterior(2R) 7-3-0 to 10-3-0, Interior (1) 10-3-0 to 14-5-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=173, 6=170. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 V02 1 12208401-12T Valley Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:jx5wd6qtPqHVMRl2TZqcLOySD5x-TDPsAr8W4m30fnbCSQd_2LPlSA6oN7GchkEd01yz82B WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =4x4 =1.5x4 =3x4 3 1 4 11 109 2 T1 T1 B1 ST1 0-5-3 10-5-4 4-9-7 10-0-1 5-2-10 5-2-10 10-5-43-6-00-0-43-2-5Scale = 1:26.8 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.42 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.36 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.15 Horiz(TL)0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 28 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)1=45/10-5-4, (min. 0-1-8), 3=71/10-5-4, (min. 0-1-8), 4=591/10-5-4, (min. 0-1-8) Max Horiz 1=-90 (LC 12) Max Uplift 1=-60 (LC 23), 3=-3 (LC 16), 4=-171 (LC 17) Max Grav 1=156 (LC 22), 3=81 (LC 2), 4=721 (LC 23) 30 30FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-100/258, 2-9=-86/300, 2-10=-90/347 WEBS 2-4=-527/241 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) 0-5-12 to 3-5-12, Interior (1) 3-5-12 to 5-3-0, Exterior(2R) 5-3-0 to 8-3-0, Interior (1) 8-3-0 to 10-5-10 zone; cantilever left and right exposed ; end vertical left andright exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 60 lb uplift at joint 1, 3 lb uplift at joint 3 and 171 lb uplift at joint 4. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 V03 1 12208401-12T Valley Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:8Wn3G8slilf4DvUd8iNJz0ySD5u-?1rUzV8uJTxA1d10vi6lV8sXmmiMef4TS4U4Tbyz82C WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB # 94535-W1 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Dansco Engineering LLC Date: 07/11/2022 812 =3x4 =4x4 =1.5x4 =3x4 3 1 4 2 T1 T1 B1 ST1 0-5-3 6-5-4 2-9-7 6-0-1 3-2-10 3-2-10 6-5-42-2-00-0-41-10-5Scale = 1:21.9 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.14 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.14 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.08 Horiz(TL)0.00 1 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 17 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-5-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 6-5-4. (lb) -Max Horiz 1=-54 (LC 12), 7=-54 (LC 12) Max Uplift All uplift 100 (lb) or less at joint(s) 1, 3, 4, 7 Max Grav All reactions 250 (lb) or less at joint(s) 1, 3, 7 except 4=466 (LC22) 31 31FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-170/256 WEBS 2-4=-355/189 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plategrip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4, 1. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy-2 Lot 132 V04 1 12208401-12T Valley Job Reference (optional) Run: 8.53 S May 4 2022 Print: 8.530 S May 4 2022 MiTek Industries, Inc. Mon Jul 11 13:42:11 Page: 1 ID:Y5SCuAve?g1f4MDCpqx0bfySD5r-TDPsAr8W4m30fnbCSQd_2LPmsA50N7RchkEd01yz82B