HomeMy WebLinkAboutA0102'-4"
1 2
7
2X
1
0
R
A
F
T
E
R
S
@ 1
6
"
0.C.212"2" RIGID INSULATION @
CRAWLSPACE FDN.
WALLS, MIN. R-1 0
2x1 2 FLOOR JOIST
PAINTED STEEL CHANNEL
BOLTED TO WOOD HEADER
14
1 2
TAPERED 2x SLEEPER
2x1 0 ROOF JOIST @ 1 6" O.C.
ROOF ASSEMBLY:
SOLDER SEAM METAL AND HIGH
TEMP MEMBRANE ON 58"
SHEATHING ON TAPERED
SLEEPERS ON 58" SHEATHING ON
RAFTERS
TYPICAL EXT. SIDED WALL:
58" DRYWALL ON 2X6 STUDS1 6"
O.C., W/ R-20 INSULATION, 12"
PLYWOOD SHEATHING, TYVEK
BUILDING PAPER AND FINISH
MATERIAL PER ELEVATIONS
AND FINISH SCHEDULE
ROOF ASSEMBLY:
GAF TIMBERLINE HD ARCHITECTURAL
SERIES ASPHALT SHINGLES ON 58" ON
MIN. #1 5 FELT UNDERLAYMENT
SHEATHING ON RAFTERS. . ICE &
WATER SHIELD MIN. 48" BEYOND
INSIDE WALL HORIZONTAL
8'-0" HD. HT.
1 2'-1 1 " HD. HT.
TYPICAL WINDOW UNIT
TYPICAL WINDOW UNIT
FLASHING W/ DRIP EDGE OVER 1 X CEDAR
TRIM ON SOLID BLOCKING W/ HALF ROUND
METAL GUTTER AND ADJUSTABLE HANGING
BRACKETS
R-49 INSULATION
3X4 WOOD PURLIN @ 2'-2" O.C. ON
STAINED 1 X6 T&G WOOD SOFFIT
1 4-2" PLT. HT.
54X_ TAPERED WOOD SILL W/ DRIP AND 1 X_
CEDAR APRON OVER FLASHING
WOLM. 2x_ SILL PLATE SET IN MASTIC
W/ 12" Ø J-ANCHOR 7" MIN DEEP @ 4'-0"
O.C. (TYP.) ~ ANCHORS TO BE 1 2"
FROM CORNER BUT NOT LESS THAN
(7) BOLT DIAMETERS FROM THE END
AND A MINIMUM OF (2) BOLTS PER
SILL SECTION (TYP)
TYPICAL FLOOR ASSEMBLY
34" WOOD FLOOR OVER
WARMBOARD RADIANT FLOOR
SYSTEM OVER 12 " LP LEGACY
SHEATHING ON JOISTS
R-49 INSULATION
STONE PAVERS ON 4" CONC. SLAB
SLOPED 2" OVER COMPACTED
GRAVEL FILL
SEE INTERIOR ELEVATIONS
FOR FINAL CASING AND BASE
TRIM DIMENSIONS
#5 BARS AT 1 8" O.C.
EACH WAY PROVIDE 112"
COVER FROM INSIDE
FACE OF WALL
MIN R30 INSULATION
AT BAY ENDS (TYP.)
GALVANIZED L3.5x3.5x3 8 STEEL
ANGLE AFFIXED TO FOUNDATION
WALL WITH 12" DIAMETER STAINLESS
STEEL EXPANSION BOLTS @ 2'-0" FOR
PORCH SLAB SUPPORT ~ TYP
8'-2" CEILING HEIGHT
FIRST FLOOR
2X WOOD HEAD TRIM
WALL SECTION AT GUEST HOUSE FOYER
SCALE: 1" = 1'-0" 1
1 0"
5" 5"7"T/LEDGE = 0'-1 0 1 /4"
FIRST FLOOR = 2'-1 "
ELEV=848'
c5.1Wall SectionsSECTION NOTES:
HEAD HEIGHTS NOTED FROM TOP OF UNIT TO TOP OF FINISH
FLOOR. COORDINATE ROUGH OPENING RECOMMENDED BY
MANUFACTURER WITH TOP OF UNIT HEAD HEIGHT.
ALL TRIM CALL OUTS AS PER KOETTER WOODWORKING
ICE AND WATER SHIELD TO BE TURNED DOWN OVER SUBFACIA
AS PER MANUFACTURERS SPECIFICATIONS.
PROVIDE VAPOR BARRIER BETWEEN CONCRETE WALL AND
FLOOR FRAMING AT DEPRESSED CONCRETE AREAS.
PROVIDE CAULK BEAD WITH BACKER ROD BETWEEN
BRICKMOLD AND WINDOW/DOOR UNIT IN SPACE
RECOMMENDED BY MANUFACTURER
VERIFY WINDOW SECTION DETAIL WITH ACTUAL. CONTACT
ARCHITECT WITH DISCREPANCIES
DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.07.22BB0'-0"= ELEV. 845.92'
08/09/22