HomeMy WebLinkAboutE001ECLIPSE 40x54 FD FD FD FD FD SSGFI LED UNDER SHELF LIGHTSLED BACK LIGHTING BEHIND TRANSLUCENT STONE TILE @ BAR WALL V.P. GFI V.P. GFI MICRO REF. ICE DW GFI GFI GFI GFI REF. CO SD SSSSSSS SS SS SSSS SS SSSSSS SS SSSS SS TO SWITCH ABOVE SS SSSS SS SSSS SSSSCUSTOM SLOT LIGHTS @CEILING AND WALLLED STRIP LIGHTING @ BEAM CUSTOM SLOT LIGHT @ WALL CUSTOM SLOT LIGHT @ WALL SSSSSSSS SSSSSS SSSSSS SSSSTO SWITCH @ FXTURE @ TUNNEL LED FLOOR UP-LIGHTING LED FLOOR UP-LIGHTING GARAGE DOOR LIFT SSSS SSCUSTOM SLOT LIGHTS @CEILING AND WALLLED STRIP LIGHTING @ BEAM SSSSSS PIN CAN LIGHTS @ RANDOM SPACING DUCK PIN OPERATOR34 4 4 44 4 4 4 4 4 4 4 3 3S3 3 3 33 3 GFI GFI GFI GFI GFI GFI GFI FINAL LOCATION OF FLOOR OUTLETS BY OWNER GOLF ROOM SMOKE ROOM PWDR. ROOM ENTERTAINMENT ROOM BAR MECHANICAL STORAGE MUD ROOM ENTRY MECHANICAL/ STORAGE LOWER LEVEL GARAGE CAR DISPLAY PWDR. ROOM HALL POOL EQUIP. GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI FOR GOLF SIMULATOR GFI TV TV GFI GFI GFI GFI GFI GFI GFI GFI GFI GFI GFISSGARAGE SLAB DETACHED GARAGE SLAB GFI AIR VENT. SYSTEM S DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBa3.0Basement Electrical PlanELECTRICAL LEGEND: GFI TV S GAS CO GROUND FAULTINTERRUPT DUPLEX LIVE AND ONE SWITCHEDSWITCHED DUPLEX WITH ONE TELEVISION JACK 220 220 VOLT OUTLET SWITCH SMOKE DETECTOR CARBON MONOXIDE WIRE IN SERIES W/ BATTERY BACK-UP WALL MOUNTED LIGHT FIXTURE PC PULL CHAIN PORCELAIN LIGHT FIXTURE CEILING ELECTRICAL BOX FOR LIGHT FIXTURE CEILING FAN WITH LIGHT FLOURESCENT LIGHT GAS FIXTURE WWX LAMPS FLOOR OUTLET VAPOR PROOF FIXTUREVP GFI ELECTRICAL NOTES: SOUND SYSTEM WIRING, TELEPHONE, TELEVISION AND COMPUTER OUTLETS TO BE PROVIDED BY OWNER'S CONTRACTOR AND COORDINATED BY GENERAL CONTRACTOR NEW WALL RECEPTACLES SHALL BE MIN. 6'-0" FROM ANY WALL 2'-0" OR MORE IN WIDTH. NEW ALL CEILING OUTLET ELECTRICAL BOXES SHALL BE FAN RATED. ALL SMOKE DETECTORS AS PER IRC. DWELLING UNIT TO HAVE AT LEAST ONE APPROVED CARBON MONOXIDE ALARM WITHIN 15 FEET OF EVERY ROOM USED FOR SLEEPING PURPOSES. ALARMS TO BE INTERCONNECTED AND HARD WIRED INTO THE AC POWER LINE WITH BATTERY BACK-UP. THE ALARM CAN BE COMBINED WITH SMOKE DETECTING DEVICES IF THE COMBINED UNIT COMPLIES WITH SPECIFIC STANDARDS AND THE ALARM DIFFERENTIATES THE HAZARD. PROVIDE A MINIMUM 30" WORKING CLEARANCE 36" IN FRONT OF THE ELECTRICAL PANEL. PROVIDE AND MAINTAIN A MINIMUM OF 24" WORKING CLEARANCE TO EACH SIDE AND 36" IN FRONT OF THE ELECTRICAL METER. ALL NEW RECESSED FIXTURES WHICH ARE IN CONTACT WITH INSULATING MATERIALS SHALL BE "IC" RATED. ALL CLOSETS 23" DEEP OR MORE AND ALL STORE ROOMS, UTILITY ROOMS AND PANTRIES SHALL BE ILLUMINATED. CLOSET LIGHTS TO HAVE A COMPLETELY ENCLOSED LAMP. MOUNT CLOSET LIGHTS AS FOLLOWS: - SURFACE MOUNTED INCANDESCENT MIN. 12" FROM NEAREST POINT OF STORAGE. - RECESSED INCANDESCENT, RECESSED AND SURFACE FLUORESCENT MIN. 6" FROM NEAREST POINT OF STORAGE COUNTERTOPS RECEPTACLES TO BE INSTALLED AS FOLLOWS: - MIN. 1 RECEPTACLE PER 24" OF HORIZ. COUNTER SURFACE. - MIN. 1 RECEPTACLE AT COUNTERTOPS 12" OR LARGER. ALL KITCHEN AND BATHROOM FIXTURES, RECEPTACLES AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED WITH GFCI PROTECTION. BATHROOM FANS TO VENT DIRECTLY TO OUTSIDE WITH APPROVED CAP (INSULATE DUCT IN ATTIC) ALL 125 VOLT, SINGLE PHASE, 15- AND 20- AMPERE RECEPTACLES INSTALLED IN BEDROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS INCLUDING AREAS IN THE BASEMENT SHALL BE INSTALLED WITH AN ARC FAULT CIRCUIT INTERRUPTER. ALL NEW RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES. A MIN. OF 90% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS. ALL GFI OUTLETS TO BE LED TYPE ALL DWELLING UNIT RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC 210.52 (A) (1) & 210.52 (A) (2) HALLWAYS OF 10 FEET OR MORE SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET. NEC 210.52 (H) A/C DISCONNECTS MAY NOT BE INSTALLED ABOVE OR BEHIND THE CONDENSERS. DISCONNECTS SHALL BE PLACED ALONGSIDE THE UNITS AND BE PROVIDED WITH 30" MIN. WIDE ACCESS DETECTOR WIRE IN SERIES WALL MOUNTED ART LIGHT WALL MOUNTED ART LIGHT SLIM JUNCTION BOXS LED LIGHTED PANEL LED RECESSED CAN ADJUSTABLE RECESSED CAN SQUARE RECESSED CAN SQUARE ADJUSTABLE RECESSED CAN RECESSED WALL MOUNTED FIXTUREWALL MOUNTED LEDLED LOW VOLTAGE LIGHT FIXTURE MOTORIZED WINDOW TREATMENT ~ CONFIRM REQ. W/ FINAL VENDOR SD BATHROOM EXHAUST FAN INLINE FAN REMOTE BATHROOM EXHAUST FAN FLOOD LIGHTS BASEMENT ELECTRICAL PLAN SCALE: 1/4" = 1'-0" 08/09/22