HomeMy WebLinkAboutE100UP
21R
DN
24R
DN
2R
S
DN 2R
DN
15R
OVERHEAD
DOOR
OVERHEAD
DOOR
TWO CAR
GARAGE
S
S
S
S GFIGFIGFIGFI GFIGFI
GFIGFIGFI
GFIWP
GFI
SIDE ENTRY SS
SSSSSSSSS
SGFIINLINE
FAN SS
SSUPER
ROOM
PANTRY
POWDER
W D
WD SSSD/
CO
SD/
CO
SSSFORMAL
PWDR GFISS
INLINE
FANSSSS
SSDISPOSAL HOODSSTOVE/OVENGFI
GFI
DW
GFI
GFI
GFI
GFI
GFI
DW
DISPOSALS
FRZ. REF.
WINE
GFI
GFI
DISPOSALSWINE
DW
GFI
GFI
REF.
ICE
GFI GFI GFI
ELEV.
DISPOSALS
GFI
GFI
DW
REF
BAR
KITCHEN HOODVP
GFI
VP
GFI
SS SS SS
TO FIXTURE
ABOVE
S
INLINE
FAN
S
GFISSS
SS
SSSICEGFIGFI
FLOOR OUTLET
LOCATIONS
BY OWNER SGFISTOVE/OVENGFI
GFI
GFISFLOOR OUTLET
LOCATIONS BY OWNER
S
S SS
SITTING
ROOM
DINING
ROOM
GREAT
ROOM SSTO FIXTURE
BELOW
SS
S
S SSTAIR
S
TO OUTDOOR
LIGHTING
TO OUTDOOR
LIGHTING
VP
GFI
VP
GFI
SD/
CO
SD/
CO SS
VP
GFI
VP
GFI
SSSSSS
POOL
BATH
VESTIBULE
BACK
KITCHEN
SSS SS
GAMING
ROOM
FAMILY
ROOM
SS
SSSSS
SD
SD
INLINE
FAN
SS
SS S S
VP
GFI
VP
GFI
TV
S S
TV
SSTV
S S
SSS
S
S
VP
GFI
VP
GFI
INLINE
FAN
VP
GFI
VP
GFI
SSGFI
GFI
GFI
S
S
S
TV
S
SD GFIVP
GFI
VP
GFI
VP
GFI
GFIGFIGFIGFIGFIGFIGFIWP
GFI SSS
SS
OVERHEAD
DOOR
S
SD/
CO
SD/
CO
INDOOR
MECHANICAL
ONE CAR
GARAGE
S
TO FIXTURES
ABOVE
VP
GFI
VP
GFI
MARLEE'S
BEDROOM
MASON'S
BEDROOM
MASON'S
BATH
MARLEE'S
BATH
FLOOR OUTLET
LOCATIONS
BY OWNER
COVERED
PORCH
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
VP
GFI
S S
S
VP
GFI
VP
GFI
S
WP
GFI
WP
GFI
WP
GFI
VP
GFI
SD/
CO
SD/
CO
POWER
IN CEILING
FOR HEATER
POWER
IN CEILING
FOR HEATER
POWER
IN CEILING
FOR HEATER
POWER
IN CEILING
FOR HEATER
POWER
IN CEILING
FOR HEATER
POWER
IN CEILING
FOR HEATER
WP
GFI
WP
GFI
DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBa3.1First Floor Electrical PlanFIRST FLOOR ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"
ELECTRICAL LEGEND:
GFI
TV
S
GAS
CO
GROUND FAULT
INTERRUPT DUPLEX
LIVE AND ONE SWITCHED
SWITCHED DUPLEX WITH ONE
TELEVISION JACK
220
220 VOLT OUTLET
SWITCH
SMOKE DETECTOR
CARBON MONOXIDE
WIRE IN SERIES
W/ BATTERY BACK-UP
WALL MOUNTED LIGHT FIXTURE
PC
PULL CHAIN PORCELAINLIGHT FIXTURE
CEILING ELECTRICAL BOX
FOR LIGHT FIXTURE
CEILING FAN WITH LIGHT
FLOURESCENT LIGHT
GAS
FIXTURE WWX LAMPS
FLOOR OUTLET
VAPOR PROOF FIXTURE
VP
GFI
ELECTRICAL NOTES:
SOUND SYSTEM WIRING, TELEPHONE, TELEVISION AND COMPUTER
OUTLETS TO BE PROVIDED BY OWNER'S CONTRACTOR AND
COORDINATED BY GENERAL CONTRACTOR
NEW WALL RECEPTACLES SHALL BE MIN. 6'-0" FROM ANY WALL
2'-0" OR MORE IN WIDTH.
NEW ALL CEILING OUTLET ELECTRICAL BOXES SHALL
BE FAN RATED.
ALL SMOKE DETECTORS AS PER IRC. DWELLING UNIT TO HAVE AT
LEAST ONE APPROVED CARBON MONOXIDE ALARM WITHIN 15
FEET OF EVERY ROOM USED FOR SLEEPING PURPOSES. ALARMS
TO BE INTERCONNECTED AND HARD WIRED INTO THE AC POWER
LINE WITH BATTERY BACK-UP. THE ALARM CAN BE COMBINED WITH
SMOKE DETECTING DEVICES IF THE COMBINED UNIT COMPLIES WITH
SPECIFIC STANDARDS AND THE ALARM DIFFERENTIATES THE
HAZARD.
PROVIDE A MINIMUM 30" WORKING CLEARANCE 36" IN FRONT OF
THE ELECTRICAL PANEL. PROVIDE AND MAINTAIN A MINIMUM OF 24"
WORKING CLEARANCE TO EACH SIDE AND 36" IN FRONT OF THE
ELECTRICAL METER.
ALL NEW RECESSED FIXTURES WHICH ARE IN CONTACT WITH
INSULATING MATERIALS SHALL BE "IC" RATED.
ALL CLOSETS 23" DEEP OR MORE AND ALL STORE ROOMS, UTILITY
ROOMS AND PANTRIES SHALL BE ILLUMINATED.
CLOSET LIGHTS TO HAVE A COMPLETELY ENCLOSED LAMP.
MOUNT CLOSET LIGHTS AS FOLLOWS:
- SURFACE MOUNTED INCANDESCENT MIN.
12" FROM NEAREST POINT OF STORAGE.
- RECESSED INCANDESCENT, RECESSED
AND SURFACE FLUORESCENT MIN. 6" FROM NEAREST POINT OF
STORAGE
COUNTERTOPS RECEPTACLES TO BE INSTALLED AS FOLLOWS:
- MIN. 1 RECEPTACLE PER 24" OF HORIZ. COUNTER SURFACE.
- MIN. 1 RECEPTACLE AT COUNTERTOPS 12" OR LARGER.
ALL KITCHEN AND BATHROOM FIXTURES, RECEPTACLES AND
ELECTRICAL EQUIPMENT SHALL BE INSTALLED WITH GFCI
PROTECTION.
BATHROOM FANS TO VENT DIRECTLY TO OUTSIDE WITH
APPROVED CAP (INSULATE DUCT IN ATTIC)
ALL 125 VOLT, SINGLE PHASE, 15- AND 20- AMPERE
RECEPTACLES INSTALLED IN BEDROOMS, FAMILY ROOMS, DINING
ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUNROOMS,
RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS
INCLUDING AREAS IN THE BASEMENT SHALL BE INSTALLED WITH AN
ARC FAULT CIRCUIT INTERRUPTER.
ALL NEW RECEPTACLES SHALL BE LISTED TAMPER RESISTANT
RECEPTACLES.
A MIN. OF 90% OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS.
ALL GFI OUTLETS TO BE LED TYPE
ALL DWELLING UNIT RECEPTACLE OUTLETS SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 210.52 (A) (1)
& 210.52 (A) (2)
HALLWAYS OF 10 FEET OR MORE SHALL HAVE AT LEAST ONE
RECEPTACLE OUTLET. NEC 210.52 (H)
A/C DISCONNECTS MAY NOT BE INSTALLED ABOVE OR BEHIND
THE CONDENSERS. DISCONNECTS SHALL BE PLACED ALONGSIDE
THE UNITS AND BE PROVIDED WITH 30" MIN. WIDE ACCESS
DETECTOR WIRE IN SERIES
WALL MOUNTED ART LIGHT
WALL MOUNTED ART LIGHT
SLIM JUNCTION BOXS
LED LIGHTED PANEL
LED
RECESSED CAN
ADJUSTABLE RECESSED CAN
SQUARE RECESSED CAN
SQUARE ADJUSTABLE
RECESSED CAN
RECESSED WALL
MOUNTED FIXTUREWALL MOUNTED LEDLED LOW VOLTAGE LIGHT FIXTURE
MOTORIZED WINDOW
TREATMENT ~ CONFIRM
REQ. W/ FINAL VENDOR
SD
BATHROOM EXHAUST FAN
INLINE FAN REMOTE BATHROOM
EXHAUST FAN
FLOOD LIGHTS
08/09/22