Loading...
HomeMy WebLinkAboutS001GARAGE SLAB RADIANT HEAT IN 5" CONCRETE SLAB W/ 6X6 W2.1X2.1 WWM OVER 10 MIL POLY V.B. AND 6" COMPRESSED GRAVEL. PAVERS ON 4" CONC. SLAB W/ FIBER MESH OVER 6 MIL V.B. ON 4" COMPRESSED GRAVEL PORCH SLAB PAVERS ON 4" CONC. SLAB W/ FIBER MESH OVER 6 MIL V.B. ON 4" COMPRESSED GRAVEL PORCH SLAB 4"Ø PERF. DRAIN TILE SET IN WASHED GRAVEL W/ SILT SOCK AT EXTERIOR PERIMETER ~ TYP 11'-10"27'-4"18'-5"4"34'-0"18'-2" FLOOR ELEVATION BREAK7'-5"20'-7"6'-9"11'-10"11'-0" 14'-3"11'-6"17'-8"19'-7"9'-9" 18'-6" FIRST FLOOR WALLS ABOVE GOLF ROOM SLAB T/SLAB ELEV. = -13'-1" R5 INSULATION UNDER SLAB BASEMENT SLAB T/SLAB ELEV. = -13'-1" R5 INSULATION UNDER SLAB SUMP PIT SUMP DISCHARGE TO GRADE FD FD FD PVC DRAIN WITH CAP CONNECT TO PERIMETER DRAIN (TYP) EGRESS LADDER (TYP.) WINDOW WELL RADIANT HEAT IN 4" CONCRETE SLAB W/ 6X6 W2.1X2.1 WWM OVER 10 MIL POLY V.B. AND 6" COMPRESSED GRAVEL. RADIANT HEAT IN 4" CONCRETE SLAB W/ 6X6 W2.1X2.1 WWM OVER 10 MIL POLY V.B. AND 6" COMPRESSED GRAVEL.8" BLOCK8" BLOCKOUTLINE OF PATIO AND POOL ABOVE BY OTHERS 36'-2" W24x117 T/STL. = 0'-0" THICKENED SLAB AT INTERIOR WALL ABOVE GALVANIZED L3.5x3.5x38STEEL ANGLE AFFIXED TO FOUNDATION WALL WITH 12" DIAMETER STAINLESS STEEL EXPANSION BOLTS @ 2'-0" FOR PORCH SLAB SUPPORT ~ TYP EJECTOR PIT CONNECT TO SANITARY SEWER CONCRETE HAUNCH FOR STOOP SUPPORT ABOVE LOWER GARAGE SLAB T/SLAB ELEV. = -13'-1" R5 INSULATION UNDER SLAB RADIANT HEAT IN 5" CONCRETE SLAB W/ 6X6 W2.1X2.1 WWM OVER 10 MIL POLY V.B. AND 6" COMPRESSED GRAVEL. GARAGE SLAB RADIANT HEAT IN 5" CONCRETE SLAB W/ 6X6 W2.1X2.1 WWM OVER 10 MIL POLY V.B. AND 6" COMPRESSED GRAVEL. CONCRETE HAUNCH FOR STOOP SUPPORT ABOVE PAVERS ON 4" CONC. SLAB W/ FIBER MESH OVER 6 MIL V.B. ON 4" COMPRESSED GRAVEL PORCH SLAB 7"5"UP 24R 15'-6" 14'-0" 5" CONCRETE SLAB ON STEEL DECK ON W8X21 JOISTS @ 4'-0" O.C. 5" CONCRETE SLAB TAPER TO 4" AT ENDS, ON STEEL DECK ON W8X21 JOISTS @ 4'-0" O.C. T/LEDGE =0'-0"T/LEDGE =+7 12" T/LEDGE =0'-0" T/LEDGE =+7 12" T/LEDGE =+7 12" 3'-0"F60 F60 F48 F36 F48 F36 F36 F48 F48 F48 F48 F36 F36 W24x117 T/STL. = 0'-0" W24x117 T/STL. = +7 12 " W24x117 T/STL. = 0'-0" W12x26 T/STL. = 0'-0" W12x26 T/STL. = 0'-0" W12x26 T/STL. = 0'-0" W12x26 T/STL. = 0'-0" W12x40 T/STL. =+7 12"W10x22T/STL. =+7 12 "W10x22T/STL. =+7 12 "W10x22T/STL. =+7 12 "W12x40 T/STL. =+7 12" W12x26 T/STL. =+7 12" W12x26 T/STL. =+7 12" W12x26 T/STL. =+7 12" HSS 6X6X 1/4 COLUMN ON 34 X12X12 BASE PLATE HSS 6X6X 1/4 COLUMN ON 34 X12X12 BASE PLATE HSS 4X4X 1/4 COLUMN ON 34 X10X10 BASE PLATE 4"Ø STANDARD STEEL PIPE COLUMN W/ PLATES ON 1'-0" DEEP CONC. PAD SEE DETAIL1 ON a2.0 F36F36 W10x22 T/STL. =+7 12 " W10x22 T/STL. =+7 12 " T/LEDGE =+7 12"W10x22T/STL. =+7 12 "4"7"5"BEAM POCKET BEAM POCKET BEAM POCKET BEAM POCKET HSS 6X6X 1/4 COLUMN ON 34 X12X12 BASE PLATE F60 GALVANIZED L3.5x3.5x38 STEEL ANGLE AFFIXED TO FOUNDATION WALL WITH 12" DIAMETER STAINLESS STEEL EXPANSION BOLTS @ 2'-0" FOR PORCH SLAB SUPPORT ~ TYP PROVIDE EXHAUST AND FRESH AIR INTAKE DEPRESS CONC. 8" FOR ELEVATOR PIT-VERIFY CONSTRUCTION W/ MANUFACTURER SPECIFICATIONS 156'-9" 54'-9" 31'-0" 44'-7" 6'-7" 2'-6" 14'-10" 2'-6" 36'-2" 5" 7" 4" 51'-11" 2" 4" 7" 5" 1'-6"28'-8" 10" 4'-10" 8" 6'-10" 8" 8'-2" 8" 18'-0" 8" 4'-1" 6'-7" 5"7"17'-10" 7" 5" 7" 5" 7" 5" 7" 5" 5" 7" 5"7" 5" 7" 7" 5" 4" 7" 5" 5"7" 3'-6" 153'-9" 7" 5" 4'-3" 2'-10" 4" 33'-8" 29'-2" 14'-3" 12'-0" 17'-2" 19'-7" 9'-9" 22'-9" 5" 7" 4" 53'-2" 5" 9'-7" 13'-7" 10'-3"H.R.16'-0" 46'-4" 9'-4" 53'-6" 21'-9"12'-1" 71'-8" 17'-8" 6'-0" 29'-10" 3'-11"14'-5" 1'-0" 23'-7" 5" 5" 13'-4" 8"1'-10" 5'-0" 2'-2" 8" 21'-4" TO DETACHED GARAGE 4" 6"14'-7"23'-7" 10" 45'-0" 40'-10" 4'-2" 13'-6" 3'-7" 2"8" 4'-8" 8" 2" 3'-7"11"8"4"15'-0"4"8"21'-7"5"7"5"7"6'-4"12'-5"27'-10"5"9"8"8'-0"5"9"8"8'-0"27'-10"1'-4"10"4'-0"4"7"5"4'-10"6'-8"39'-11"29'-4"14'-6"5"7"8'-10"6"4"5'-5"10"8'-10"4"7"5"7'-5"20'-5"18'-9"4'-11"5"7"5"7"5"7"18'-7"8"4'-0"7"5"23'-6"5'-5"5"5"3'-0"6'-4"3'-4"7"5"7"5"7"5"34'-10"5"7"3'-8"4"8"35'-7"1'-2"1'-6"9'-4"1'-3"9'-4"2'-4"5'-10"4'-7"3'-1"1'-2"6'-10"8"4'-2"39'-6"35'-7"1'-2"29'-7"4'-7"8'-11"12'-7"10'-4"10'-1"11'-4"8'-6"13'-10"35'-1"4'-7"62'-0"ROUGH-IN BATH ROUGH-IN BATH CF24 CF24 CF24 CF28 CF24 CF28 CF28 CF24 5" CONCRETE SLAB TAPER TO 4" AT ENDS, ON STEEL DECK ON W8X21 JOISTS @ 4'-0" O.C. DEPRESS FOUNDATION FOR DUCK PIN BALL RETURN, VERIFY WITH MANUFACTURER ELEVATION832.75 @ DOORW10x22T/STL. =+7 12 "5'-2" 3'-0" 3'-4" 8"8'-8"8" 3'-4" 21'-10"45'-0" 3'-0" 5" 20'-2" 10" 4'-4"2'-6"10"9'-10"1'-2"1'-6"30'-5"5'-2"9'-4"2'-3"8'-8" 12'-8" 8" 8" 6"36'-11"5"2'-6"10'-8"12'-7"10"4'-6"8"30'-5"3 2.0 2 2.0 STEPEJECTOR PIT CONNECT TOSANITARYSEWERFD POOL EQUIP. SLAB T/SLAB ELEV. = -9'-0" 4" CONCRETE SLAB W/ 6X6 W2.1X2.1 WWM OVER 10 MIL POLY V.B. AND 6" COMPRESSED GRAVEL.FD UP 15R FOUNDATION WALL BELOW BLOCK WALL TO LOWER SLAB 8"1'-6"8" BLOCK WALL 3'-3" 4" 8"8"4"14'-4"10"CONCRETE STEPS MINIMUM 2X6 PLATE GLUED AND FASTENED TO STEEL WITH 12" Ø BOLTS AT 2'-8" O.C. SEE S1.0 OR A2.0 SHEETS FOR STEEL SIZE 8"8"4"Ø STANDARD STEEL PIPE COLUMN W/ SHOP WELDED 12" BASE PLATES W/ (4) 78"Ø HOLES 34" X 7" EXPANSION BOLTS TO BE DRILLED AFTER CONCRETE PADS ARE COMPLETE ALLOWING FOR PRECISE LOCATION OF THE COLUMN. T/STEEL = 0'-0" UNLESS NOTED OTHERWISE #5 BAR 9" O.C. EACH WAY WITH 3" BOTTOM COVER BASE PLATE GRAVEL BASE BEAM TO COLUMN CONNECTIONS SHALL BE DESIGNED BY THE STEEL FABRICATOR TO RESIST THE REACTIONS INDICATED ON THE DRAWINGS OR ONE HALF THE PUBLISHED UNIFORM LOAD CARRYING CAPACITY OF THE SUPPORTED BEAMS UNDISTURBED SOIL SECTION AT TYPICAL COLUMN PAD SCALE: 34 " = 1'-0"1'-0"3'-0" UNLESS NOTED OTHERWISECOLUMN HEIGHT VARIESFIELD VERIFY11'-0"2'-0" TYPICAL FOOTING DETAIL SCALE: 3 4 " = 1'-0"2 EXTERIOR BASEMENT WALLS: 58" DRYWALL ON 2X4 STUDS WITH R-13 INSULATION FROM TOP OF WALL TO SLAB RUB-R-WALL DAMP PROOFING ~ TYP (2) #5 BARS TOP, MIDDLE & BOTTOM CONTINUOUS 4"Ø PERF. DRAIN TILE SET IN WASHED GRAVEL W/ SILT SOCK AT EXTERIOR PERIMETER ~ TYP #5 BARS VERTICAL AND HORIZONTAL 18" O.C. - 112" FROM INSIDE FACE OF WALL BASEMENT SLAB = -13'-10" 2"X4" MIN. KEYWAY 6" 6" B/FOOTING TO BEAR ON MIN1500 PSF SOIL (3) #5 BARS CONTINUOUS WITH 3" COVERAGE ~ TYP10"TYPICAL FROST WALL DETAIL SCALE: 34 " = 1'-0"3 (2) #5 BARS TOP, MIDDLE & BOTTOM CONTINUOUS ~ TYP 2"X4" MIN. KEYWAY 6" 6" B/FOOTING MIN 48" BELOW GRADE AND MIN.1500 PSF SOIL (2) #5 BARS CONTINUOUS WITH 3" COVERAGE ~ TYP 1'-0"VARIES (SEE PLAN) BACKFILL. COMPACT AT AREAS OF PATIOS, FINISH SURFACES, ECT AT GRADE BACKFILL. COMPACT AT AREAS OF PATIOS, ECT AT GRADE 112 "3"3"3"3" HEATED SLAB : 4" CONCRETE SLAB W/ 6X6 W2.1 OVER 10 MIL V.B. ON 4" COMPRESSED GRAVEL WITH R5 RIGID UNDER ENTIRE HEATED SLAB DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBa2.0aFoundation PlanFOUNDATION PLAN SCALE: 1/4" = 1'-0" GENERAL FDN PLAN NOTES: ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL, STATE AND NATIONAL CODES. USE FIGURED DIMENSIONS ONLY; DRAWINGS ARE NOT TO BE SCALED. ANY DIMENSIONAL DISCREPANCIES ARE TO BE BROUGHT TO THE ARCHITECTS ATTENTION AFTER THE CONTRACTOR HAS FIELD VERIFIED ALL DIMENSIONS. CONTRACTOR TO EVALUATE SOIL UPON EXCAVATION. CONTACT SOILS ENGINEER AS NEEDED BOTTOM OF ALL EXTERIOR FOOTINGS, PIERS, ECT TO BE BELOW FROST DEPTH, MINIMUM 4'-0" BELOW GRADE. ALL FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR COMPACTED FILL HAVING A MINIMUM ALLOWABLE BEARING CAPACITY OF 1500 PSF. STORM WATER, WINDOW WELLS AND FOUNDATION DRAINS MUST DISCHARGE TO STORM SEWER, NOT INTO SANITARY SEWER. REFER TO CIVIL ENGINEERING DRAWINGS FOR FINAL. BACKFILL SHALL NOT BE PLACED AGAINST THE WALL UNTIL THE WALL HAS SUFFICIENT STRENGTH AND HAS BEEN ANCHORED TO THE FLOOR ABOVE, OR HAS BEEN SUFFICIENTLY BRACED TO PREVENT DAMAGE BY BACKFILL. PROVIDE 10' MIN. BETWEEN SUMP PUMP AND EJECTOR PIT. MECHANICAL VENTILATION IN BASEMENT LEVEL TO PROVIDE .35 AIR EXCHANGE PER HOUR. 0'-0"= ELEV. 845.92' 08/09/22