HomeMy WebLinkAboutS103MUD ROOM
EXERCISE ROOM 2880YOKU-SH SPA UNIT
STEAM
SPA
2480LINEN
BUILT-IN
MECHANICAL/
STORAGE
SAFE ROOM/
STORAGE
WINDOW WELL
WOOD DECK TO MATCH YOKU-SH
2'-6" ABOVE FLOOR, WITH
REMOVABLE PANELS AS
NECESSARY FOR EQUIP. ACCESS
DEPRESS SLAB 1'-6"
BELOW
5010
0 TEMP.
GLASS LIFT AND
SLIDE POCKET
DOOR STEPSHIDDENPANELDOORFD
FD
11'-0" CEILING
ENG. H.W. FLOORTERRACED PLANTEROPEN FOR
STAIR
ABOVE
~12'-1" CEILING
SPORT FLOOR
11'-0" CEILING
10'-0" B/BEAMMETAL CLAD
COLUMN
11'-0" CLG.
3080
BUILT-IN
STORAGE
ISLAND
2610 0 TEMP.
GLASS DOOR
W/METAL FRAME
NOTE:
EQUIPMENT DRAWN FOR
REFERENCE ONLY, FINAL
LOCATION TO BE
VERIFIED IN FIELD
SUMP
PIT
EJECTOR
PIT
TEMP. GLASS
IN 6'-6" TALL
METAL FRAME
@10'-0" HD. HT.
MILLMADE STAIR
S.S.
T.
11'-0" CEILING
TILE FLOOR
SPA BATH
9'-0" CEILING
TILE FLOOR
58" TYPE X FIRE RATED DRYWALL
BUILT-IN
BUILT-IN
FRAME TO
MATCH
OPPOSITE
58" TYPE X FIRE RATED DRYWALLPOLISHED STAINED
CONCRETE FLOOR
10'-0" B/BEAMSTONE VENEER
BUILT-IN CABINETHALL
11'-0" CEILING
ENG. H.W. FLOOR ENG. H.W. FLOOR
10'-0"
B/BEAM
ACCESS FOR SAUNA
EQUIPMENT PER
MANUFACTURER'S
SPECIFICATIONS
HANDRAIL5"15'-0"5"
5"
5"
5" 5"
STONE VENEER
5"
4'-6"5"
9'-0"9" 3'-10" 3'-10"
5"
2"2" 5" 3'-0" 5" 5'-8"
13'-10"1'-0" 19'-11" 7" 3'-8" 4'-4" 10"
5"
1'-7" 5"17'-9"
5" 13'-10" 1'-0" 19'-11"
7"
3'-8" 5'-2" 1'-0"19'-2"5"
14'-0"1'-0" 19'-2"
10"5" 5"4"5'-5"1'-0"16'-7"5"4"5"10"1'-0"5'-0"5'-8"8"5'-0"8"5'-0"1'-0"8"1'-0"4"9'-0"2"1'-0"5"2'-3"EGRESS WINDOWS(3'-0" SILL HT. )EGRESS WIN.
(3'-0" SILL HT. )5"4'-10"4'-11"4'-11"3'-1" 10'-9"6"4'-10"6"4"7"11'-10"5'-5"1'-0"5'-8"5'-6"5"5"5"6"4'-6"6"5"16'-8"5"1'-0"2'-6"10'-0"BOARD FORMED CONCRETE
WALL @ TUNNEL
1'-2"
STONE VENEER ON BLOCK WALL
7'-6" HIGH OPENING
DRIVEWAY
BREAK LINE
58" TYPE 'X' FIRECODE
DRYWALL AT
UNDERSIDE OF STAIR
MILLMADE
STAIR-
7.63" RISER10"36'-2"
11'-3"
SAUNA
HYDROSPA
COLD (58")
HYDROSPA
HOT (58")2'-10"4 PANEL TEMP.
GLASS AND
METAL FRAME
SLIDING DOOR
3:12 8:12 8:12
8:128:128:12 8:12
1/4:12 1/4:121/4:12
1/4:12
±2:12EXTERIOR MATERIALS SCHEDULE
TAG BASE BID BASE BID NOTES ALTERNATE BID ALTERNATE NOTES
ROOFING
R1 SLATE VERMONT SPANISH BLACK
SLATE
~ 38" - 58" THICKNESS
R2 16" STANDING SEAM
METAL REVERE FREEDOM GRAY BERRIDGE ALUMINUM WITH KYNAR
FINISH WEATHERED ZINC
R3 16" SOLDER SEAM REVERE FREEDOM GRAY BERRIDGE 90° ZEE LOCK PANELS
FOR LOW SLOPES ZINC COTE
GUTTERS, DOWNSPOUTS, COPINGS & FLASHING (TYPICAL AT ALL LOCATIONS UNLESS NOTED OTHERWISE)
G1 FLASHING, COPINGS, ECT. REVERE FREEDOM GRAY BERRIDGE ALUMINUM WITH KYNAR
FINISH WEATHERED ZINC
G2 6" HALF ROUND GUTTERS &
6" DOWNSPOUTS
REVERE FREEDOM GRAY BERRIDGE ALUMINUM WITH KYNAR
FINISH WEATHERED ZINC
REFER TO GENERAL PERFORMANCE SPECIFICATIONS FOR PRODUCT AND ASSEMBLY REQUIREMENTS. ANY SUBSTITUTIONS TO BE
BROUGHT TO ATTENTION OF ARCHITECT
DS
DS
DS
DS
DS DS
DS
DS
DS
DS
R1
R3
R2
R1
R3
"LIVE ROOF" DEEP TRAYS
R1
R3
R1
R1
R3
METAL CAP OVER CUT
STONE WITH 1 12" WASH 1/4:12R3
DS
FOOTING PAD BELOW FOR
TAPERED/CURVED WALLS
5" CONCRETE SLAB ON
STEEL DECK ON W8X21
JOISTS @ 4'-0" O.C.ELEV. 832.5@ OPENING36'-2"8"4"2'-6"DROP FOUNDATION WALL
@ DRIVEWAY OPENING 10'-0"1'-2"
7'-0"22'-10"1'-6"FTG.1'-2"1'-6"FTG.18'-8"11'-10"7'-10" 9'-0" 13'-0" 11'-8"2'-6"3'-8"1'-0"T/LEDGE +8'-0"
T/F +8'-8"
OUTLINE OF BASE OF DRIVEWAY
WALLS
R16'-8"DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBb2.2Finished Basement Plan &Roof PlanFINISHED MASTER
SUITE BASEMENT PLAN
SCALE: 1/4" = 1'-0"
BASEMENT PLAN NOTES:
ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL,
STATE AND NATIONAL CODES.
USE FIGURED DIMENSIONS ONLY; DRAWINGS ARE NOT TO BE
SCALED. ANY DIMENSIONAL DISCREPANCIES ARE TO BE
BROUGHT TO THE ARCHITECTS ATTENTION AFTER THE
CONTRACTOR HAS FIELD VERIFIED ALL DIMENSIONS.
BASEMENT OUTLETS TO BE GFCI IN UNFINISHED AREAS
COORDINATE ALL WORK ON THIS SHEET WITH SHEET a2.0
MECHANICAL VENTILATION IN BASEMENT TO PROVIDE .35 AIR
CHANGE PER HOUR.
CONCEALED SPACE BEING CONNECTED BECAUSE OF
DROPPED CEILINGS OR SOFFITS IN THE BASEMENT THAT ARE
OVER 1,000 SQUARE FEET SHALL BE DRAFT STOPPED INTO
APPROXIMATELY EQUAL AREAS.
FOR IECC PRESCRIPTIVE METHOD, EXTERIOR WALLS OF
HEATED BASEMENT SHALL HAVE INSULATION NOT LESS THAN
R19 CAVITY FROM TOP OF BASEMENT WALL TO -48" BELOW
GRADE OR R-13 CAVITY FULL HEIGHT, SLAB TO CEILING.
MASTER SUITE
ROOF PLAN
SCALE: 1/4" = 1'-0"
GENERAL ROOF NOTES:
ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL,
STATE AND NATIONAL CODES.
REFER TO MATERIALS SCHEDULE ON EXTERIOR ELEVATION
SHEETS FOR FINISH MATERIALS AND NOTES
ICE AND WATER SHIELD OVER ENTIRE ROOF OF 5:12 PITCH
OR LESS, UP WALLS OF DORMERS AND MINIMUM 24"
HORIZONTALLY PAST INTERIOR WALLS. REFER TO ROOF
MANUFACTURE FOR FINAL RECOMMENDATIONS.
VERIFY LOW PITCH ROOF UNDERLAYMENTS AND METAL ROOF
SEAM TYPE AS SPECIFIED BY MANUFACTURER
AS ABLE, GROUP THROUGH ROOF UTILITY PENETRATIONS AND
WRAP WITH METAL TO MATCH ROOFING.
ALL FLASHING, GUTTERS AND DOWN SPOUTS TO MATCH
METAL ROOFING MATERIAL.
EAVE VENTS SHALL BE INSTALLED TO COMPLY WITH IRC
R806
PARTIAL TUNNEL
FOUNDATION PLAN
SCALE: 1/4" = 1'-0" 08/09/22