HomeMy WebLinkAboutS2008:12 8:12
3:12 3:12D.S.
D.S.
D.S.
M.E.P. ROOF
PENETRATIONS TO BE
COVERED BY
REMOVABLE METAL
CHIMNEY CAP TO
MATCH MAIN HOUSE
1/2:12BEDROOM
JULIE'S
OFFICE
DN
21R
BALCONY
BATH
PROVIDE KNOCK OUT
WALL FOR FUTURE
REACH-IN CLOSET
PROVIDE KNOCK OUT
WALL FOR FUTURE
REACH-IN CLOSET
268 0 PCKT DOOR
268 0 PCKT DOOR
4:12 8:12 8:128:124:12
3:124:128:128:12 1/4:128:128:121/4:121/4:121/4:121/4:1253'-0"5"9'-5"10'-5"19'-2"8'-9"2'-7"22'-0"
3'-8"18'-4"53'-0"19'-10"10'-9"22'-5"5"6"
EQ (10'-0")EQ (10'-0")
T
S
SHOWER
TMPPROVIDE SOUND
PROOFING
S&R
5"6'-0"8"13'-0"5"5'-9"5"6'-1"5"7'-6"6"4'-7"7"10"6" 4'-8" 5'-3" 8" 10'-0"
6" 4'-8" 5"15'-11"
10" 5" 5'-3"5" 7'-2"6"2'-0" 2'-0"
3'-5"6'-3"6"17'-7"3'-5"
VAULTED CEILING
HW FLOOR 3:123:128:128:12VAULTED CEILING
COMPOSITE WOOD DECK±2:129'-4" CEILING
HW FLOOR
1'-0"
±2:12
2'-8"DS
DS DS
DS DS
DS
DS DS DS
DS
DS
DS
DS
DS
DS
DSDS DS
DS
DS
DS DS
DS
DS
DS
DS
DS
DS DS
"LIVE ROOF" DEEP TRAYS
R1
R3
R3
DS
R3
R1
R1 R1
R3
R3
R1
R3
R1
R2
R2
R2
R1
R1
R2
R3
R2
R3
R1
METAL CAP OVER CUT
STONE WITH 1 12" WASH
METAL CAP OVER CUT
STONE WITH 1 12" WASH
R2
8:12
1/4:121/4:121/4:12 1/4:12±1/2:12±1/2:121/4:12R3
EQ (8'-0") EQ (8'-0")3'-0" CENTER OPENINGON RIDGE6"
R2
1
SD
SDCO
SD
ECLIPSE
40x54
ELEVATOR
DOOR TO BE
COORDINATED
W/ELEVATOR SPEC'S
& SHOP DWG'S
5"
EQ.
±1'-0" EQ.±1'-0"9'-0"9'-0"
MILLMADE
STAIR-
7.56" RISER10"3'-0" RAILWALLHANDRAIL6"3'-0"9'-4" CEILING
HW FLOOR
8'-6" CEILING
8'-6" CEILING
OUTLINE OF FUTURE
CLOS. WALL
6X8 STAINED
WOOD BEAMS
MARVIN MODERN WINDOW
W/TEMPERED GLASS
154 8
0 TMP
LIFT AND SLIDE BUILT-INM.E.P. ROOF
PENETRATIONS TO BE
IN THIS AREA
2680
2680
268026808:12 8:12 8:128:12R1
M.E.P. ROOF
PENETRATIONS TO BE
IN THIS AREA
EXTERIOR MATERIALS SCHEDULE
TAG BASE BID BASE BID NOTES ALTERNATE BID ALTERNATE NOTES
ROOFING
R1 SLATE VERMONT SPANISH BLACK
SLATE
~ 38" - 58" THICKNESS
R2 16" STANDING SEAM
METAL REVERE FREEDOM GRAY BERRIDGE ALUMINUM WITH KYNAR
FINISH WEATHERED ZINC
R3 16" SOLDER SEAM REVERE FREEDOM GRAY BERRIDGE 90° ZEE LOCK PANELS
FOR LOW SLOPES ZINC COTE
GUTTERS, DOWNSPOUTS, COPINGS & FLASHING (TYPICAL AT ALL LOCATIONS UNLESS NOTED OTHERWISE)
G1 FLASHING, COPINGS, ECT. REVERE FREEDOM GRAY BERRIDGE ALUMINUM WITH KYNAR
FINISH WEATHERED ZINC
G2 6" HALF ROUND GUTTERS &
6" DOWNSPOUTS
REVERE FREEDOM GRAY BERRIDGE ALUMINUM WITH KYNAR
FINISH WEATHERED ZINC
REFER TO GENERAL PERFORMANCE SPECIFICATIONS FOR PRODUCT AND ASSEMBLY REQUIREMENTS. ANY SUBSTITUTIONS TO BE
BROUGHT TO ATTENTION OF ARCHITECT DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBa2.2Second Floor Plan & Roof PlanROOF PLAN
SCALE: 1/4" = 1'-0"
GENERAL ROOF NOTES:
ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL,
STATE AND NATIONAL CODES.
REFER TO MATERIALS SCHEDULE ON EXTERIOR ELEVATION
SHEETS FOR FINISH MATERIALS AND NOTES
ICE AND WATER SHIELD OVER ENTIRE ROOF OF 5:12 PITCH
OR LESS, UP WALLS OF DORMERS AND MINIMUM 24"
HORIZONTALLY PAST INTERIOR WALLS. REFER TO ROOF
MANUFACTURE FOR FINAL RECOMMENDATIONS.
VERIFY LOW PITCH ROOF UNDERLAYMENTS AND METAL ROOF
SEAM TYPE AS SPECIFIED BY MANUFACTURER
AS ABLE, GROUP THROUGH ROOF UTILITY PENETRATIONS AND
WRAP WITH METAL TO MATCH ROOFING.
ALL FLASHING, GUTTERS AND DOWN SPOUTS TO MATCH
METAL ROOFING MATERIAL.
EAVE VENTS SHALL BE INSTALLED TO COMPLY WITH IRC
R806
SECOND FLOOR ROOF PLAN
SCALE: 1/4" = 1'-0"1
PLAN NOTES:
ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL,
STATE AND NATIONAL CODES.
PROJECT TO FOLLOW IECC PRESCRIPTIVE REQUIREMENTS.
USE FIGURED DIMENSIONS ONLY; DRAWINGS ARE NOT TO BE
SCALED. ANY DIMENSIONAL DISCREPANCIES ARE TO BE BROUGHT
TO THE ARCHITECTS ATTENTION AFTER THE CONTRACTOR HAS
FIELD VERIFIED ALL DIMENSIONS.
COORDINATE ALL CEILING AND FLOOR FRAMING WITH INTERIOR
ELEVATIONS AND BUILDING SECTIONS CEILING HEIGHTS AND
OPENING HEIGHTS. ANY PROPOSED DROPPED CEILINGS FOR
M.E.P. RUNS TO BE COORDINATED WITH ARCHITECT.
STAIR RISE AND RUN AS PER INTERNATIONAL RESIDENTIAL CODE.
MAXIMUM RISE OF 7 3/4", 10" MINIMUM TREAD CLEAR OF TREAD
ABOVE AND A CONTINUOUS MINIMUM 6'-8" HEADROOM MEASURED
VERTICALLY FROM FRONT NOSING OF TREAD TO LINE PARALLEL
WITH STAIR RUN. SEE DETAIL ON PAGE T1.0
HANDRAIL AS PER IRC AT ALL STAIRS AND OTHER REQUIRED
LOCATIONS. MAXIMUM SPACING OF UP RIGHTS AT HANDRAILS NOT
TO ALLOW PASSAGE OF AN OBJECT 4" OR GREATER IN
DIAMETER. SEE DETAIL ON PAGE T1.0
INSULATE WALLS AND FLOOR OF BATHROOMS FOR SOUND
CONTROL.
TEMPERED GLASS NEXT TO EGRESS DOORS, TUBS, ALL GLASS
WITHIN 18" OF THE FINISHED FLOOR, SHOWER ENCLOSURES,
WINDOWS ADJACENT TO TUBS AND OTHER REQUIRED AREAS.
ALL SAFETY GLASS SHALL BE PERMANENTLY LABELED AS
OUTLINED PER IRC
FIREPLACE AS PER IRC AND t1.0 DETAIL. MASON TO VERIFY FLUE
SIZES WITH FIREBOX OPENINGS.
MINIMUM GYPSUM WALL BOARD THICKNESS SHALL BE 58".
ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A
MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET:
-GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR
OPENING OF 5 SQUARE FEET.
-THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24".
-THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20".
AT CONFINED SPACE OF LAUNDRY ROOM, PROVIDE COMBUSTION
AND MAKE UP AIR PER IRC CH 17. TWO OPENINGS FOR
COMBUSTION AIR ARE REQUIRED IN A CONFINED SPACE, ONE WITH
12" FROM THE CEILING AND ONE WITHIN 12" OF FROM THE FLOOR.
MINIMUM OPENING SIZE TO BE 100 SQ INCHES AND 3" MIN
DIMENSION. LOCATE 6"X20" LOWER VENT IN PANEL OF DOOR
AND 12"X12" UPPER VENT ABOVE DOOR HEADER. SIZED BASED
ON 24000 BTU/HR DRYER.
08/09/22