HomeMy WebLinkAboutS201SEE ROOF FRAMING FOR RAFTER SIZING SEE ROOF FRAMING FOR RAFTER SIZING SEE ROOF FRAMING FOR RAFTER SIZING 1 1 7/8" TJI 21 0 F.J. AT 1 6" O.C.D.W. CLG. 1 0'-0" A.F.F. DBL JSTDBL JST(2) 1 4" LVL(2) 1 4" LVL(2) 2X1 0(2) 2X1 0(2) 2X1 0(2) 2X1 2 (2) 2X1 0 (2) 2X1 0 (4) 1 34" x 1 1 14 " LVL HSS 8X6X14 STEELMOMENT FRAMEHSS 8X6X14 STEELMOMENT FRAMEHSS 8X6X14 STEELMOMENT FRAMEHSS 8X6X14 STEELMOMENT FRAMEHSS 6X6X14 STEELSHEAR WALL FRAMEHSS 8X6X14 STEELMOMENT FRAMEHSS 6X6X14 COL.HSS 6X6X 14 COL.HSS 6X6X14 COL.HSS 6X6X14 COL.HSS 6X6X14 COL. HSS 6X6X14 COL.HSS 6X6X14 COL.HSS 6X6X14 COL.HSS 6X6X14 COL.HSS 6X6X14 COL.HSS 6X6X14 COL.5 14" SQ. PSL COL.5 14" SQ. PSL COL.W8X1 8 0"W8X1 8 W8X1 8 W8X1 8W8X1 8W8X1 8 HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 514" S Q . P S L C O L . 514" SQ. PSL COL.514" SQ. PSL COL.514" SQ. PSL COL.514" SQ. PSL COL.HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 514" SQ. PSL COL.514" SQ . P S L C O L . HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 (3) 1 34" x 1 1 14 " LVL (2) 1 34" x 1 1 78 " LVL IN CONST. (2) 1 34" x 1 1 78 " LVL IN CONST.(2) 1 34" x 1 1 78 " LVL IN CONST. (2) 1 34" x 1 4 " LVL W1 2X40 2X1 0 CLG JOISTS AT 1 6" O.C. D.W. CLG. TO MATCH PITCH OF ADJ. RAFTERS 1 4" 230 TJI JOISTS AT 1 6" O.C.D.W. CLG. TO MATCH PITCH OF ADJ. RAFTERSBEARING WALLBEARING WALLBEARING WALL(3) 1 34" x 1 4 " LVL (3) 1 34 " x 1 4 " LVL (3) 1 34" x 1 4 " LVL STEEL CHANNEL FOR MASONRY SUPPORT ABOVE OPEN FOR ELEVATOR 2X1 0 CLG JOISTS AT 1 6" O.C. D.W. CLG. 8'-6" A.F.F. 2X1 0 CLG JOISTS AT 1 6" O.C. D.W. CLG. 1 0'-0" A.F.F. (3) 2X1 0 (3) 1 34" x 1 1 14 " LVL2X1 0 CLG JOISTS AT 1 6" O.C.D.W. CLG. 1 0'-0" A.F.F.(3) 1 34" x 9 12 " LVL(3) 1 34" x 9 12 " LVL2X1 0 BALCONY JOISTS AT 1 6" O.C. (2) 1 34" x 1 1 78 " LVL HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 OPEN FOR STAIR 2X1 0 CLG @1 6" O.C.D.W. CLG. 9'-4" A.F.F.(2) 1 34" x 1 4 " LVLBEARING WALLBEARING WALL(3) 1 34" x 1 114 " LVL(3) 1 34" x 1 1 14 " LVLW1 2X40 2X1 0 CLG @ 1 6" O.C., 9'-4" A.F.F HALFTONE LINE INDICATESROOF FRAMING ABOVE, SEE a6.22X1 0 CLG @1 6" O.C.D.W. CLG. 9'-4" A.F.F.2X1 0 CLG JOISTS AT 1 6" O.C.D.W. CLG. TO MATCH PITCH OF ADJ. RAFTERS(3) 1 34" x 9 12 " LVL (3) 1 34" x 9 12 " LVL 4X6 PURLINS ON 4X8 WOOD RAFTER TAILS 2X6 DECKING ABOVE BEARING WALL2X1 0 CLG JOISTS AT 1 6" O.C. D.W. CLG. 8'-6" A.F.F. 2X1 0 RAFTER TIES AT 1 6" O.C. D.W. CLG. ±13'-1" ABOVE SLAB HALFTONE LINE INDICATESROOF FRAMING ABOVE, SEE a6.2(2) 1 34" x 1 4 " LVL (3) 1 34" x 1 4 " LVL HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 2X1 0 CLG @1 6" O.C.D.W. CLG. 9'-4" A.F.F.HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.22X1 0 JOISTS @ 1 6" O.C.MATCH ADJ. RAFTERS(3) 1 34" x 1 4 " LVL (2) 1 34" x 1 1 14 " LVL (3) 1 34" x 1 4 " LVL 2X1 0 RAFTER TIES AT 1 6" O.C. D.W. CLG. 1 5'-1 "A.F.F.(2) 1 34" x 9 12 " LVL(2) 1 34" x 9 12 " LVL(3) 1 34" x 1 6 " LVL BEARING WALLHALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 2X1 0 JOISTS @ 1 6" O.C. MATCH ADJ. RAFTERS 2X1 0 CLG @1 6" O.C. D.W. CLG. 8'-8" A.F.F.2X1 0 CLG @1 6" O.C.D.W. CLG. 9'-0" A.F.F.2X1 0 CLG @1 6" O.C. D.W. CLG. 8'-8" A.F.F. (3) 1 34" x 1 4 " LVLHALFTONE LINE INDICATESROOF FRAMING ABOVE, SEE a6.2HALFTONE LINE INDICATESROOF FRAMING ABOVE, SEE a6.2HALFTONE LINE INDICATESROOF FRAMING ABOVE, SEE a6.2HALFTONE LINE INDICATES ROOF FRAMING ABOVE, SEE a6.2 (3) 1 34" x 1 1 14 " LVL (3) 1 34" x 1 114 " LVL(3) 1 34" x 1 4 " LVL (2) 1 34" x 1 4 " LVL 312 " SQ. PSL COL.312 " SQ. PSL COL.312 " S Q . PS L C O L . 312 " SQ. PSL COL.3" Ø STD. STL. COL.312 " S Q . P S L C O L .3" Ø STD. STL. COL.(3) 1 34" x 1 6 " LVL(3) 1 34" x 1 6 " LVL(3) 1 34" x 1 6 " LVLSTEEL CHANNEL FORMASONRY SUPPORT ABOVE(3) 1 34" x 1 1 14 " LVLSTEEL CHANNEL FOR MASONRY SUPPORT ABOVE (3) 1 34" x 1 6 " LVL 514" SQ. PSL COL.514" SQ. PSL COL.51 4" SQ. PSL COL.(3) 1 34" x 1 1 14 " LVLSTEEL ANGLE @STONE LINTEL(2) 1 34" x 1 1 14 " LVL51 4" SQ. PSL COL.514" SQ. PSL COL.STEEL ANGLE ABOVE FOR MASONRY SUPPORT @ GABLE END W8X1 8STL BRACKETW8X1 8STL BRACKET4X6 PURLINS ON 4X8 WOOD RAFTER TAILS ON 4X8 WOOD BRACKETS BOLTED TO SOLID BLOCKING 2X6 DECKING ABOVE 2X1 0 CLG @1 6" O.C.D.W. CLG. 1 0'-0" A.F.F. STEEL ANGLE BOLTED TO LVL RAFTER FOR MASONRY SUPPORT ABOVE (2) 1 34" x 9 12 " LVL RAFTER DOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBa6.1First Floor Ceilng/ SecondFloor Framing PlanSTRUCTURE NOTES: ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL, STATE AND NATIONAL CODES. USE FIGURED DIMENSIONS ONLY; DRAWINGS ARE NOT TO BE SCALED. ANY DIMENSIONAL DISCREPANCIES ARE TO BE BROUGHT TO THE ARCHITECTS ATTENTION AFTER THE CONTRACTOR HAS FIELD VERIFIED ALL DIMENSIONS. COORDINATE ALL FRAMING OPENINGS AND CEILING HEIGHTS WITH INTERIOR ELEVATIONS, BUILDING SECTIONS & ELEVATIONS, SECTIONS & DETAILS AND PLANS. DISCREPANCIES TO BE BROUGHT TO ARCHITECTS ATTENTION. PROVIDE DOUBLE JOISTS BELOW TUBS, PARALLEL PARTITIONS ABOVE, AND ISLANDS. (3) 2 X 1 0 HEADERS AT EXTERIOR DOORS AND WINDOWS UNLESS NOTED OTHERWISE. SOLID SQUARES INDICATE LOCATIONS OF BEARING POINTS WITH LOADS BEING TRANSFERRED BELOW TO OTHER STRUCTURAL MEMBERS, STEEL OR FOUNDATION. OPEN SQUARES INDICATE TRANSFERRED LOADS ABOVE. FOR SPANS OVER 4' WIDE, HEADERS & BEAMS REQUIRE 2" MIN BEARING BOTH ENDS BY WIDTH OF BEAM, UNLESS NOTED OTHERWISE. AT ENGINEERED BEAMS & HEADERS, FOLLOW MANUFACTURES SPECIFICATIONS FOR BEARING REQUIREMENTS BASED ON HALF OF MAXIMUM ALLOWED LOAD. PROVIDE BRIDGING AT JOISTS AS PER FLOOR JOIST MANUFACTURERS SPECIFICATIONS. CUTS, NOTCHES AND HOLES BORED IN TRUSSES, LAMINATED VENEER LUMBER, GLUE-LAMINATED MEMBERS OR I-JOISTS ARE NOT PERMITTED UNLESS THE EFFECTS OF SUCH ARE SPECIFICALLY ADDRESSED. EXTERIOR OR LOAD BEARING WALLS WITH STUDS DRILLED WITHIN 5/8” OF THE FACE OF THE STUD SHALL BE REINFORCED WITH A STRUCTURAL STUD SHOE STEEL LINTELS SPANS TO BE AS FOLLOWS UNLESS NOTED OTHERWISE (MATERIAL WEIGHT UNDER 40 PSF): - 3" X 3"X 14" 6'-0" WITH NO STORY ABOVE, 4'-6" WITH ONE STORY ABOVE, 3'-0" WITH 2 STORIES ABOVE. - 4"X3"X 1 4" 8'-0" WITH NO STORY ABOVE, 6'-0" WITH ONE STORY ABOVE, 4'-6" WITH 2 STORIES ABOVE. - 5" X31 2"X 51 6 " 1 0'-0" WITH NO STORY ABOVE, 8'-0" WITH ONE STORY ABOVE, 6'-0" WITH 2 STORIES ABOVE. - 6"X312"X 51 6 " 1 4'-0" WITH NO STORY ABOVE, 9'-6" WITH ONE STORY ABOVE, 7'-0" WITH 2 STORIES ABOVE. STEEL LINTELS TO BE BOLTED BACK TO FRAMING WITH 7/1 6" BOLTS AT 24" O.C.. USING SLOTTED HOLE IN STEEL, ALLOW FOR VERTICAL SLIPPAGE BETWEEN WOOD AND STEEL LINTELS. LINTELS TO HAVE MIN 4" END SUPPORT BEARING. VERIFY MINIMUM 23 OF THICKNESS OF MASONRY TO BEAR ON LINTEL "LVL" REFERS TO 2.0E MICROLLAM LVL ENGINEERED LUMBER. "PSL" REFERS TO 2.2E PARALLAM ENGINEERED LUMBER. RIDGE BOARDS, HIP AND VALLEY RAFTERS SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER BEING SERVED. ALL FIREPLACE HEARTHS TO BE SELF SUPPORTING REINFORCED CONCRETE SLAB TO CARRY THEIR OWN WEIGHT AND ALL IMPOSED LOADS. NO COMBUSTIBLE MATERIAL SHALL BE USED TO SUPPORT HEARTH OR REMAIN AGAINST THE UNDERSIDE OF HEARTHS AND HEARTH EXTENSIONS AFTER CONSTRUCTION. VERIFY FINAL WIDTH AND DEPTH OF FLUSH HEARTHS ABOVE ANY PORTION OF A MASONRY CHIMNEY LOCATED WITHIN THE BUILDING ENVELOPE SHALL HAVE A MINIMUM AIRSPACE OF 2" TO COMBUSTIBLE MATERIALS. CHIMNEY FLUES WITH CHIMNEY LINING SYSTEM RATED WITH UL 1 777 FOR CHIMNEYS IN CONTACT WITH COMBUSTIBLE MATERIALS ARE PERMITTED TO HAVE COMBUSTIBLE MATERIAL IN CONTACT WITH THEIR EXTERIOR SURFACE. PROVIDE DRAFTSTOPPING AT THE FOLLOWING LOCATIONS: CONCEALED SPACES OF STUDS, WALL AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVEL. ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES, SUCH AS OCCURS AT SOFFITS, DROP CEILINGS, COVER CEILING, ETC. CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT THE CEILING AND FLOOR LEVEL, WITHOUT NONCOMBUSTIBLE MATERIALS. 1 " MINIMUM CLEARANCE SHALL BE PROVIDED FROM KITCHEN EXHAUST DUCT TO THE COMBUSTIBLE FRAMING ANY LUMBER IN CONTACT WITH CONCRETE SHALL BE TREATED FOR DECAY ALL FASTENERS AND CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE HOT DIPPED GALVANIZED OR EQUAL IN CORROSION RESISTANCE. THIS APPLIES TO ALL ITEMS LESS THAN 12" THICKNESS OR DIAMETER INCLUDING NAILS AND SCREWS. FIRST FLOOR CEILING/SECOND FLOOR FRAMING PLAN SCALE: 1 /4" = 1 '-0" 08/09/22