HomeMy WebLinkAboutS2022x10 RAFTERS AT 16" O.C.2x10 RAFTERS AT 16" O.C.2x10 RAFTERS AT 16" O.C.2x10 RAFTERS AT 16" O.C. 2x8 RAFTERS AT 16" O.C.(2) 1114" LVL(2) 1114" LVLDBL RAFTER DBL RAFTER DBL RAFTER DBL RAFTER (2) 11 78 " LVL RIDGE (2) 11 78 " LVL RIDGE (2) 11 78 " LVL RIDGE HSS 8X6X14 STEELMOMENT FRAMEHSS 8X6X14 STEELMOMENT FRAMEHSS 8X6X14 STEELMOMENT FRAMEHSS 8X6X14 STEELMOMENT FRAMEW8X18 W8X18W8X18 W8X18 W8X18 W8X18 11 7/8 LVL RAFTERS AT 16" O.C.(2) 11 78 " LVLS(2) 11 78 " LVLS(2) 11 78 " LVLS(2) 11 78 " LVLS(3) 11 78 " LVLS (3) 11 78 " LVLS (3) 11 78 " LVLS (2) 11 78 " LVLS (2) 11 78 " LVLS STEEL BEAM BELOW(2) 11 78 " LVL RIDGE (2) 11 78 " LVL RIDGE 2x10 RAFTERS AT 16" O.C. 2x10 RAFTERS AT 16" O.C. 11 7/8 LVL RAFTERS AT 16" O.C.2x10 RAFTERS AT 16" O.C.2x10 RAFTER TIES BELOW 9'-4" FROM FLOOR AT 16" O.C.(3) 16" LVL RIDGESTEEL BEAM BELOW2x10 RAFTERS AT 16" O.C.(3) 11 78 " LVLS (3) 11 78 " LVLS(3) 22" LVL RIDGE 2x10 RAFTERS AT 16" O.C. 2x10 RAFTER TIES BELOW 15'-1" FROM FLOOR AT 16" O.C. BEAM BELOW BEAM BELOW (3) 11 14 " LVLS BEAM BELOW RAFTERS ON 2X6 BEARING BLOCK OVER BEARING WALL BELOW 2x12 RAFTERS AT 16" O.C. 2x10 RAFTERS AT 16" O.C.2x12 RAFTERS AT 16" O.C.2x10 RAFTERS AT 16" O.C.(2) 16" LVL RIDGE(2) 16" LVL RIDGE2x10 RAFTER TIES BELOW 12'-0" FROM FLOOR AT 16" O.C.2x12 RAFTERS AT 16" O.C. 2x10 RAFTERS AT 16" O.C. 2x10 RAFTER TIES BELOW ±13'-1" HEIGHT FROM SLAB AT DOOR AT 16" O.C. DASHED LINE INDICATES OUTLINE OF EXTERIOR WALL BELOW HALFTONE LINE INDICATES OUTLINE OF INTERIOR WALL BELOW (2) 9 14 " LVLSOVER FRAME RAFTERS DASHED LINES INDICATE ROOF RAFTERS BELOW DASHED LINES INDICATE ROOF RAFTERS BELOW OVER FRAME RAFTERS HALFTONE LINE INDICATES ROOF RAFTERS ABOVE (3) 14 " LVLS (3) 14 " LVLSBEAM BELOWBEAM BELOW BEAM BELOW (2) 16" LVL RIDGE(2) 16" LVL RIDGEBEAM BELOW 2X12 RAFTERS @ 16" O.C. OVER FRAME RAFTERS DASHED LINES INDICATE ROOF RAFTERS BELOW 1 BOLD LINES INDICATE SECOND FLOOR WALLS BEAM BELOWBEAM BELOW (3) 11 14 " LVLS CANTILEVER @ END (3) 11 14 " LVLS CANTILEVER @ END BRACKET BELOWBRACKET BELOW2x10 RAFTER TIES BELOW9'-4" FROM FLOOR AT 16" O.C.2x10 RAFTERS AT 16" O.C.(2) 16" LVL RIDGE(2) 16" LVL RIDGE(2) 16" LVL RIDGE(2) 16" LVL RIDGEDOCUMENT:DRAWN BY:CHECKED:MA1 4 8 B u r l i n g t o n A v e n u eC l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4P 6 3 0 . 6 5 5 . 9 4 1 7PROJECT NO:21017MICHAEL ABRAHAMA R C H I T E C T U R Em i c h a e l - a b r a h a m . c o mSycamore Creek Residence10404 Ditch RoadCarmel, INIssued For Permit 06.08.22BBa6.2Roof Framing PlanSTRUCTURE NOTES: ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH LOCAL, STATE AND NATIONAL CODES. USE FIGURED DIMENSIONS ONLY; DRAWINGS ARE NOT TO BE SCALED. ANY DIMENSIONAL DISCREPANCIES ARE TO BE BROUGHT TO THE ARCHITECTS ATTENTION AFTER THE CONTRACTOR HAS FIELD VERIFIED ALL DIMENSIONS. COORDINATE ALL FRAMING OPENINGS AND CEILING HEIGHTS WITH INTERIOR ELEVATIONS, BUILDING SECTIONS & ELEVATIONS, SECTIONS & DETAILS AND PLANS. DISCREPANCIES TO BE BROUGHT TO ARCHITECTS ATTENTION. PROVIDE DOUBLE JOISTS BELOW TUBS, PARALLEL PARTITIONS ABOVE, AND ISLANDS. (3) 2 X 10 HEADERS AT EXTERIOR DOORS AND WINDOWS UNLESS NOTED OTHERWISE. SOLID SQUARES INDICATE LOCATIONS OF BEARING POINTS WITH LOADS BEING TRANSFERRED BELOW TO OTHER STRUCTURAL MEMBERS, STEEL OR FOUNDATION. OPEN SQUARES INDICATE TRANSFERRED LOADS ABOVE. FOR SPANS OVER 4' WIDE, HEADERS & BEAMS REQUIRE 2" MIN BEARING BOTH ENDS BY WIDTH OF BEAM, UNLESS NOTED OTHERWISE. AT ENGINEERED BEAMS & HEADERS, FOLLOW MANUFACTURES SPECIFICATIONS FOR BEARING REQUIREMENTS BASED ON HALF OF MAXIMUM ALLOWED LOAD. PROVIDE BRIDGING AT JOISTS AS PER FLOOR JOIST MANUFACTURERS SPECIFICATIONS. CUTS, NOTCHES AND HOLES BORED IN TRUSSES, LAMINATED VENEER LUMBER, GLUE-LAMINATED MEMBERS OR I-JOISTS ARE NOT PERMITTED UNLESS THE EFFECTS OF SUCH ARE SPECIFICALLY ADDRESSED. EXTERIOR OR LOAD BEARING WALLS WITH STUDS DRILLED WITHIN 5/8” OF THE FACE OF THE STUD SHALL BE REINFORCED WITH A STRUCTURAL STUD SHOE STEEL LINTELS SPANS TO BE AS FOLLOWS UNLESS NOTED OTHERWISE (MATERIAL WEIGHT UNDER 40 PSF): - 3" X 3"X 14" 6'-0" WITH NO STORY ABOVE, 4'-6" WITH ONE STORY ABOVE, 3'-0" WITH 2 STORIES ABOVE. - 4"X3"X 14" 8'-0" WITH NO STORY ABOVE, 6'-0" WITH ONE STORY ABOVE, 4'-6" WITH 2 STORIES ABOVE. - 5" X31 2"X 516" 10'-0" WITH NO STORY ABOVE, 8'-0" WITH ONE STORY ABOVE, 6'-0" WITH 2 STORIES ABOVE. - 6"X31 2"X 516" 14'-0" WITH NO STORY ABOVE, 9'-6" WITH ONE STORY ABOVE, 7'-0" WITH 2 STORIES ABOVE. STEEL LINTELS TO BE BOLTED BACK TO FRAMING WITH 7/16" BOLTS AT 24" O.C.. USING SLOTTED HOLE IN STEEL, ALLOW FOR VERTICAL SLIPPAGE BETWEEN WOOD AND STEEL LINTELS. LINTELS TO HAVE MIN 4" END SUPPORT BEARING. VERIFY MINIMUM 23 OF THICKNESS OF MASONRY TO BEAR ON LINTEL "LVL" REFERS TO 2.0E MICROLLAM LVL ENGINEERED LUMBER. "PSL" REFERS TO 2.2E PARALLAM ENGINEERED LUMBER. RIDGE BOARDS, HIP AND VALLEY RAFTERS SHALL NOT BE LESS IN DEPTH THAN THE CUT END OF THE RAFTER BEING SERVED. ALL FIREPLACE HEARTHS TO BE SELF SUPPORTING REINFORCED CONCRETE SLAB TO CARRY THEIR OWN WEIGHT AND ALL IMPOSED LOADS. NO COMBUSTIBLE MATERIAL SHALL BE USED TO SUPPORT HEARTH OR REMAIN AGAINST THE UNDERSIDE OF HEARTHS AND HEARTH EXTENSIONS AFTER CONSTRUCTION. VERIFY FINAL WIDTH AND DEPTH OF FLUSH HEARTHS ABOVE ANY PORTION OF A MASONRY CHIMNEY LOCATED WITHIN THE BUILDING ENVELOPE SHALL HAVE A MINIMUM AIRSPACE OF 2" TO COMBUSTIBLE MATERIALS. CHIMNEY FLUES WITH CHIMNEY LINING SYSTEM RATED WITH UL 1777 FOR CHIMNEYS IN CONTACT WITH COMBUSTIBLE MATERIALS ARE PERMITTED TO HAVE COMBUSTIBLE MATERIAL IN CONTACT WITH THEIR EXTERIOR SURFACE. PROVIDE DRAFTSTOPPING AT THE FOLLOWING LOCATIONS: CONCEALED SPACES OF STUDS, WALL AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVEL. ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES, SUCH AS OCCURS AT SOFFITS, DROP CEILINGS, COVER CEILING, ETC. CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS AND FIREPLACES AT THE CEILING AND FLOOR LEVEL, WITHOUT NONCOMBUSTIBLE MATERIALS. 1" MINIMUM CLEARANCE SHALL BE PROVIDED FROM KITCHEN EXHAUST DUCT TO THE COMBUSTIBLE FRAMING ANY LUMBER IN CONTACT WITH CONCRETE SHALL BE TREATED FOR DECAY ALL FASTENERS AND CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE HOT DIPPED GALVANIZED OR EQUAL IN CORROSION RESISTANCE. THIS APPLIES TO ALL ITEMS LESS THAN 12" THICKNESS OR DIAMETER INCLUDING NAILS AND SCREWS. ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" ROOF FRAMING PLAN ABOVE SECOND FLOOR SCALE: 1/4" = 1'-0"1 08/09/22