HomeMy WebLinkAbout_t1.0[413180]34"-36" HIGH FINISH FLOOR58" TYPE "X" FIRECODEDRYWALL UNDERSIDEOF STAIR112"10" MIN.6'-8"*THIS DRAWING FORCODE COMPLIANCE ONLY114" - 214"GRIPPABLE HANDRAILRISE FROM FINISHFLOOR TO FIRST TREADEQUALS TYPICAL RISE34" -114" NOSING734" MAX EQUAL 8" MIN.ASH DUMP WHERE APPLICABLE8"MIN.FIRE CLAY FLUE LININGFIREPLACE HEARTH AND HEARTH EXTENSION SHALL EXTEND A MINIMUMOF 36" FROM THE BACK OF THE FIREBOX TO THE END OF THE HEARTHEXTENSION. HEARTH EXTENSIONS SHALL EXTEND AT LEAST 16" INFRONT OF, AND AT LEAST 8" BEYOND, EACH SIDE OF THE FIREPLACEOPENING. WHERE THE FIREPLACE OPENING IS 6 SQ. FT. OR LARGER, THEHEARTH EXTENSION SHALL EXTEND AT LEAST 20" IN FRONT OF, AND ATLEAST 12" BEYOND, EACH SIDE OF THE FIREPLACE OPENING,SEE PLANS AND INTERIORELEVATIONS FOR FINISHDIMENSIONS MATERIALSSELF SUPPORTINGREINFORCED CONCRETESLAB HEARTH TO CARRYALL IMPOSED LOADSSMOKE CHAMBER*THIS DRAWING FOR CODECOMPLIANCE ONLY.FIREBRICK FIREBOXFIREBOX FLOOR1 12" BELOW HEARTH.HEARTHNOTE: WOOD-BURNINGFIREPLACES MUST HAVETIGHT-FITTING CASTIRON FLUE DAMPERSPER IECCMANTEL MINIMUM 12"FROM FLUE LININGSUPPLY OUTDOORCOMBUSTION AIR PER IRC1"1" SPACE WITH NONCOMBUSTIBLE INSULATIONSMOKE SHELF34" MIN. HANDRAIL @ STAIRS. 38" MAX. HANDRAIL @ STAIRS. 30" ABOVE FLOOR @ PORCHES, OPEN SIDES OF STAIR OR RAISED FLOORS. 36" MIN. GUARDRAIL HEIGHT. LESS THAN 4"1 14"-2 34" GRIPPABLERAIL. FINAL PROFILEBY STAIR DESIGNER1 14" TO 2 34"34" MAX. 78" MAX. 38" MIN.HANDRAILS THAT ARENOT TERMINATED BY ANEWEL POST ARE TORETURN TO A WALLHANDRAILS SHALL RUN THEFULL LENGTH ON AT LEASTONE SIDE OF THE STAIR516" MIN. GRASPABLEFINGER RECESS AREA ONBOTH SIDES OF RAILTYPE I HANDRAIL:TYPE II HANDRAIL:CIRCULAR HANDRAIL WITH 1 14"MIN. Ø OR 2" MAX. Ø ~ MUSTHAVE PERIMETER OF 4" MIN. OR6 14" MAX, WITH A MAX CROSSSECTION DIMENSION OF 2" PERIRC R311.5.6.3NON-CIRCULAR HANDRAIL112"112"MIN. 18" R.EDGE1 12" MIN. TO WALLAT TYPE I ANDTYPE II HANDRAIL1 12" MIN. TO WALLAT TYPE I ANDTYPE II HANDRAIL*THIS DRAWING FOR CODECOMPLIANCE ONLY.BALUSTERS OPENINGSTO BE LESS THAN 4"MAIN HOUSE SUPPLY RISER DIAGRAMMAIN HOUSE DRAINAGE/ VENT DIAGRAM1-1/2"MT&P RELIEFVALVEW.H.75 gal.SINKREFRIG.HOTCOLDDWHOTCOLDTHROUGH ROOF4"-5" VENT INCREASERCOMECHANICALTO PUBLIC SAN.SEWER @ STREETFD4"EJECTOR PITW/ PUMP4"4"NOTE:ALL NEW PLUMBING MUST MEET 2020 INDIANARESIDENTIAL CODEWATER SERVICE FROM MAIN TO BUILDING TO BEINSTALLED BY A LICENSED PLUMBERCONTRACTOR TO VERIFY ALL SUPPLY, DRAINAGE,AND VENT PIPING ARE SIZED IN ACCORDANCE WITHTHE 2020 INDIANA RESIDENTIAL CODEFLOOR DRAINS SHALL BE VENTED PER 2020INDIANA RESIDENTIAL CODECO2"LAVWCFORMAL POWDER RM4"HOTCOLDLAVWCMIXINGVALVESHOWERSHOWERWCCO4"LAV2"4"BATHROOM1 14"1"34"34"34"12"12"34"34"1 14"1 14"34"34"12"12"34"1 12"BATHROOM2"2"2"2"MASTERBATHROOM2" WATER METER4"COKITCHENREFRIG.2"DWSINKMIXINGVALVELAV 1WCTUBHOTCOLDLAV 2MIXINGVALVESHOWER4" FLOOR DRAINMECHANICALROOM4"2"CO2"1 1/4" DIA.W.H.75 gal.CO2"4"LAVWC2"LAVTUB2"2"SHOWERLAV2"CO34"F.P.H.BF.P.H.BSPASPALAVWCHOTCOLDMIXINGVALVEHOT TUBLAV2"WC4"STEAM2"HOT TUB2"2"4"COBACK KITCHENREFRIG.2"DWSINKFRZ2"SINKFRZ2"SHOWERWCCO4"LAV2"4"POOL BATHSHOWERWCCO4"LAV2"4"MASON'S BATHSHOWERWCCO4"LAV2"4"MARLEE'S BATHTUBCO2"LAVWCPOWDER ROOM4"4"COPANTRYREFRIG.2"DWSINKSUPERROOMCO4" FD2"W/ 2" DIA.GREY BOXWASHER4"SINK4" FD2"W/ 2" DIA.GREY BOXWASHERCO2"SINKDOGROOMSHOWER2"4"4"WC4" FD2"W/ 2" DIA.GREY BOXWASHERMASTERSUITE2"SINKSHOWER4" FLOOR DRAINELEVATOR PITCOWC4"LAV2"4"COGARAGE POWDER ROOMSINK4"COSTORAGE2"4" FLOOR DRAINWCCO4"LAV2"BASEMENT POWDER ROOM4" FLOOR DRAINMECHANICAL ROOMCOLAV4" FLOOR DRAINCOLDPLUNGEMIXINGVALVESTEAM SHOWERMIXINGVALVECOLD PLUNGELAVWC12"34"GARAGE POWDER ROOMSINK12"34"STORAGEHOTCOLDLAVWC12"34"BASEMENT POWDER ROOMKITCHENFRZ.12"SINKREFRIG.DW34"34"12"12"BACK KITCHENFRZ.12"SINK12"DWDWLAVWCMIXINGVALVESHOWER12"12"34"34"POOL BATHMIXINGVALVESHOWER12"HOTCOLDLAVWCMIXINGVALVESHOWER12"12"34"34"MASON'S BATHHOTCOLDLAVWCMIXINGVALVESHOWER12"12"34"34"MARLEE'SBATHMIXINGVALVETUB12"SINKREFRIG.DW34"12"12"PANTRYLAVWC12"34"FORMALPOWDER ROOMHOTCOLDLAVWC12"34"POWDER ROOMWASHER12"12"12"SINK12"SUPER ROOMWASHER12"DOG ROOMMIXINGVALVESINKSHOWERMIXINGVALVESHOWERWCWASHER12"SINKF.P.H.BGUEST HOUSE SUPPLY RISER DIAGRAMGUEST HOUSE DRAINAGE/ VENT DIAGRAMMT&P RELIEFVALVEW.H.75 gal.KITCHENSINKREFRIG.DWHOTCOLDTHROUGH ROOF4"-5" VENT INCREASERCOMECHANICALTO PUBLIC SAN.SEWER @ STREETFD4"EJECTOR PITW/ PUMPGUEST BATH 1LAVWCSHOWERCOHOTCOLD1 14"1 14"34"34"12"12"1 12"2"1" WATER METER4" FLOOR DRAINMECHANICALROOM2"4"2"2"4"CO2"1"34"F.P.H.BCOLDGUEST BATH 1LAV WCMIXINGVALVESHOWERLAV MIXINGVALVETUBLAVWC12"34"POWDER ROOMWASHER12"LAUNDRYLAVWCMIXINGVALVESHOWER12"12"34"34"GUEST BATH 2F.P.H.BSINKF.P.H.BDETACHED GARAGELAV2"TUB2"4"COKITCHENREFRIG.2"DWSINKWCCO4"LAV2"4"POWDER ROOMLAUNDRYCO4" FD2"W/ 2" DIA.GREY BOXWASHERSHOWERWCCO4"LAV2"4"GUESTBATH 24"2"SINKCODETACHEDGARAGE12"EXHAUST OPENING:TERMINATE PIPE MIN. OF 12"ABOVE ROOF. LOCATE MIN. 10FEET FROM ANY OPENINGPROVIDE FOR FUTUREINSTALLATION OF AN ACTIVEDEPRESSURIZATION SYSTEM, ANELECTRIC CIRCUIT SHALL BEINSTALLED DURINGCONSTRUCTION IN ANTICIPATEDLOCATION OF FANS. FAN TO BEIN ACCESSIBLE LOCATION.SUPPORT STRAP (TYP.)3" MIN. PVC SCHEDULE40 VENT PIPEPROVIDE PERMANENT LABEL ONVENT PIPE - "PASSIVE RADONREDUCTION SYSTEM" 4'-0" A.F.F.SEAL ALL OPENINGS IN SLABAT ALL PENETRATIONS ANDAROUND PERIMETERTYPICAL SLAB WITH 10 MILVAPOR BARRIER AND 4" ORMORE OF GRAVEL5 FOOT PERFORATED PVCEXTENSIONS EA. END OF TEEBASEMENTLIVING AREAPASSIVE RADON MITIGATION SYSTEM4'-0" MIN.MIN.SQUARE FOOTAGEMAIN HOUSE9833.9 SQ. FT.COVERED/SCREEN PATIO1162.2 SQ. FT.ATTACHED GARAGE628.00 SQ. FT.ZEN ROOM453.1 SQ. FT.FRONT PORCH166.00 SQ. FT.SIDE ENTRY PORCH149.03 SQ. FT.DETACHED GARAGE732.8 SQ. FT.GUEST HOUSE2134.8 SQ. FT.SECOND FLOOR1015.7LOWER LEVEL FINSHED4878.0 SQ. FT.LOWER LEVEL GARAGE3808.90 SQ. FT.LOWER LEVEL UNFINISHED1593.30 SQ. FT.t1.0General Building Info DOCUMENT:DRAWN BY: CHECKED: MA 1 4 8 B u r l i n g t o n A v e n u e C l a r e n d o n H i l l s I l l i n o i s 6 0 5 1 4 P 6 3 0 . 6 5 5 . 9 4 1 7 PROJECT NO: 21017 M ICHAEL A BRAHAM A R C H I T E C T U R E m i c h a e l - a b r a h a m . c o m Sycamore Creek Residence 10404 Ditch Road Carmel, IN Issued For Permit 06.08.22BB SHEET INDEXPROJECT TEAM(630) 655-9417 ARCHITECTURECONTACT: MIKE ABRAHAM (MA@MICHAEL-ABRAHAM.COM)MICHAEL ABRAHAM ARCHITECTURE, LLC.CLARENDON HILLS, ILLINOIS 60514148 BURLINGTON AVENUET Y P I C A L D E T A I L @ S T A I R SCALE: 1" = 1'-0"T Y P I C A L D E T A I L @ F I R E B O XSCALE: 1" = 1'-0"T Y P I C A L R A I L D E T A I L SCALE: 3" = 1'-0"TYPICAL DETAILSSUPPLY & DRAINAGE/VENT DIAGRAMPROJECT INFORMATIONBERNIE BARTELLI (BB@MICHAEL-ABRAHAM.COM)RADON DIAGRAMMICHAEL ABRAHAM ARCHITECTUREDRAWING SET:COVER SHEETt1.0 GENERAL INFORMATIONt1.1ARCHITECTURAL SITE PLAN (116" SCALE)t1.2SPECIFICATIONSA-MAIN HOUSEa1.1NORTH ELEVATION AND BUILDING SECTIONa1.2SOUTH ELEVATION AND BUILDING SECTIONa1.3WEST ELEVATION AND EAST BUILDING SECTIONa2.0FOUNDATION PLANa2.1FIRST FLOOR PLANa2.2SECOND FLOOR PLAN & ROOF PLANa2.3FINISHED BASEMENT PLANa3.0LOWER LEVEL ELECTRICAL PLANa3.1FIRST FLOOR ELECTRICAL PLANa3.2SECOND FLOOR ELECTRICAL PLANa4.1INTERIOR ELEVATIONSa4.2INTERIOR ELEVATIONSa4.3INTERIOR ELEVATIONSa4.4INTERIOR ELEVATIONSa4.5INTERIOR ELEVATIONSa4.6INTERIOR ELEVATIONSa4.7INTERIOR ELEVATIONSa4.8INTERIOR ELEVATIONSa4.9INTERIOR ELEVATIONSa4.10INTERIOR ELEVATIONSa4.11INTERIOR ELEVATIONSa4.12INTERIOR ELEVATIONSa5.1MAIN HOUSE WALL SECTIONSa6.0FIRST FLOOR DECK FRAMING PLANa6.1SECOND FLOOR DECK FRAMING PLANa6.2ROOF FRAMING PLANB-MASTER SUITE WINGb1.1MASTER SUITE NORTH & SOUTH ELEVATIONS & BUILDING SECTIONb1.2MASTER SUITE EAST ELEVATION & BUILDING SECTIONb2.1MASTER SUITE FOUNDATION & FLOOR PLANb2.2MASTER SUITE FINISHED BASEMENT & ROOF PLANb3.1MASTER SUITE ELECTRICAL PLANSb6.1MASTER SUITE FRAMING PLANSC-GUEST HOUSE/DETACHED GARAGEc1.1GUEST HOUSE & DETACHED GARAGE ELEVATIONSc2.1GUEST HOUSE & DETACHED GARAGE FLOOR PLAN & FDN. PLANc2.2GUEST HOUSE & DETACHED GARAGE ROOF PLANc3.1GUEST HOUSE & DETACHED GARAGE ELECTRICAL PLANSc5.1GUEST HOUSE & DETACHED GARAGE WALL SECTIONSc6.0GUEST HOUSE & DETACHED GARAGE FIRST FLR FRAMING PLANc6.1GUEST HOUSE & DETACHED GARAGE SECOND FLR FRAMING PLANc6.2GUEST HOUSE & DETACHED GARAGE ROOF FRAMING PLANBUILDERENNIS CUSTOM HOMES200 SOUTH RANGELINE ROADCARMEL, IN 46032CONTACT: BRAD ENNISBRAD@ENNISCUSTOMHOMES.COM(812)287-1878CIVIL ENGINEERKIMLEY-HORN AND ASSOCIATES250 EAST 96TH STREETINDIANAPOLIS, IN 46240CONTACT: ANDY TAYLOR(317) 218-9560LANDSCAPE ARCHITECTHEATHER HARWOOD13265 N EASTSHORE DRSYRACUSE, IN 46567(574) 518-0252HHHARWOOD@AOL.COMSTANDARDS AND REGULATIONS1. CONTRACTOR SHALL PERFORM ALL WORK IN CONFORMANCE WITH APPLICABLEBUILDING CODES, REGULATIONS, ORDINANCES, UTILITY PROVIDER AND SIMILARSTANDARDS.2. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASESREQUIRED FOR CONSTRUCTION AND OCCUPANCY. CONTRACTOR SHALL FURNISH COPIESOF ALL SUCH ITEMS TO OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT. IF PERMITSARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE WORK OR IF THEPERMITS ARE DELAYED FOR ANY REASON, CONTRACTOR SHALL NOTIFY ARCHITECTIMMEDIATELY.3. CONTRACTOR SHALL OBTAIN ALL REQUIRED INSPECTIONS OF THE WORK;CONTRACTOR SHALL REGULARLY UPDATE OWNER AND ARCHITECT REGARDING THESTATUS OF INSPECTIONS.4. CONTRACTOR SHALL BE FAMILIAR WITH REQUIREMENTS AND CONSTRUCTION SHALLBE IN COMPLIANCE WITH REFERENCED FIRE-RATED ASSEMBLY TESTS AND STANDARDS.5. IF UNANTICIPATED HAZARDOUS MATERIALS ARE ENCOUNTERED, CONTRACTOR SHALLCEASE WORK IN THE AREA AND CONTACT ARCHITECT AND OWNER IMMEDIATELY.6. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMISSION OF BIDS TO REVIEW EXISTINGCONDITIONS AND DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL CONDITIONSSHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO SUBMISSION OFBIDS.7. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID ANDCONSTRUCTION.8. IT IS THE INTENT OF THESE DOCUMENTS THAT THE WORK DESCRIBED HEREIN, WHENACCOMPLISHED, SHALL CONSTITUTE A COMPLETE JOB. ALL COORDINATION, FEES,TASKS, LABOR, MATERIALS, TOOLS, CONNECTIONS, EQUIPMENT, CLEANUP (UNLESSOTHERWISE NOTED IN DOCUMENTS) REQUIRED TO FULLY FINISH THE DESCRIBEDPROJECT SHALL BE FURNISHED AND PAID FOR BY THE CONTRACTOR WITHIN THE SCOPEOF THE WORK. ANY AND ALL EXCEPTIONS SHALL BE REQUESTED AND AGREED TO INWRITING AT THE TIME OF THE SIGNING OF THE OWNER/CONTRACTOR AGREEMENT.ADMINISTRATION OF WORK1. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS ANDSEQUENCES OF CONSTRUCTION.2. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE SAFETY OF ALLCONSTRUCTION PERSONNEL AND AUTHORIZED VISITORS.3. CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TOTHE WORK. ANY KNOWN DISCREPANCIES BETWEEN THE DOCUMENTS AND ACTUALCONDITIONS SHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION PRIOR TOPROCEEDING WITH WORK RELATED TO THIS DISCREPANCY.4. CONTRACTOR SHALL BECOME FAMILIAR WITH AND COMPLY WITH OWNER'S (ORBUILDING OWNER'S) PROCEDURES FOR MAINTAINING SECURE SITE AND BUILDING.5. EACH INSTALLER SHALL EXAMINE SUBSTRATE CONDITION AND/OR SITE CONDITIONSWHICH AFFECT THE QUALITY OF EACH PRODUCT TO BE INSTALLED. IF ANY CONDITIONSEXIST WHICH WILL HAVE A DETRIMENTAL EFFECT ON THE QUALITY OF THE INSTALLATION,THE INSTALLER SHALL IMMEDIATELY NOTIFY THE CONTRACTOR. INSTALLATION SHALLNOT PROCEED UNTIL THE UNSATISFACTORY CONDITIONS ARE CORRECTED.INSTALLATION SHALL SIGNIFY ACCEPTANCE OF THE CONDITIONS AS SUITABLE FOR THEIRTRADE.6. CONTRACTOR SHALL MAINTAIN RECORD DRAWINGS ON SITE AT ALL TIMES.7. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING COORDINATION EFFORTS OFALL.8. CONTRACTOR SHALL LAY OUT WORK AS SOON AS POSSIBLE. ANY DISCREPANCIESSHALL BE REPORTED TO THE DESIGNER FOR RESOLUTION PRIOR TO PROCEEDING WITHTHE WORK IN QUESTION.9. ALL CONTRACTORS SHALL REPORT ANY CONFLICTS/INCONSISTENCIES IMMEDIATELYTO THE DESIGNER AND PRIOR TO PROCEEDING WITH THEIR WORK.10. ANY PERIODIC VISITS TO THE JOB SITE BY THE ARCHITECT ARE FOR THE PURPOSEOF DETERMINING COMPLIANCE WITH THE TECHNICAL PROVISIONS OF THE CONTRACTDOCUMENTS AND ARE IN NO WAY A GUARANTEE OF INSURANCE, NOR ASSUMERESPONSIBILITY FOR METHODS OR APPLIANCES USED BY THE CONTRACTOR, NOR THESAFETY ON THE JOB IN COMPLIANCE WITH THE LAW AND REGULATIONS.11. FRAMER SHALL LAYOUT ALL STUDS/ CEILING JOISTS/ RAFTERS TO ACCOMMODATERECESSED LIGHTS, EXHAUST FANS OR OTHER ELECTRICAL/ MECHANICAL FIXTURES.12. FINISH GRADE SHALL SLOPE AWAY FROM BUILDING A MINIMUM OF 2%.13. WHERE NO DETAILS ARE SHOWN OR NOTED FOR ANY PART OF THE WORK, THEDETAILS SHALL BE THE SAME AS FOR ANY OTHER SIMILAR WORK OR AS DIRECTED BYTHE ARCHITECT.14. ALL WORK UNDER ALL SECTIONS SHALL BE PERFORMED IN STRICT ACCORDANCEWITH THE HIGHEST STANDARDS OF PRACTICE RELATED TO THE TRADES INVOLVED, ANDSHALL BE COMPLETE AND PROPERLY COORDINATED WITH ALL WORK ADJACENT ORRELATED TO IT.15. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS THAT THE NEW CONSTRUCTIONOF THE PROJECT WHEN COMPLETED SHALL CONFORM TO REGULATIONS AT THE TIME OFPLAN CHECK, OF THE GOVERNING CODES. PERFORM ALL WORK IN ACCORDANCE WITHTHE LATEST EDITION OF LOCAL RESIDENTIAL BUILDING CODES AND ANY ADOPTEDCODES AND REGULATIONS, AND STANDARDS16. WORK IN FURRED AREAS SHALL NOT BE CONCEALED UNTIL SUCH WORK HAS BEENINSPECTED AND APPROVED BY THE INSPECTING AUTHORITIES. IF SUCH WORK ISCONCEALED WITHOUT INSPECTION AND APPROVAL, THE CONTRACTOR SHALL BEFINANCIALLY RESPONSIBLE FOR ALL WORK REQUIRED TO OPEN AND RESTORE THECONCEALED AREAS IN ADDITION TO ANY REQUIRED MODIFICATION TO THE SYSTEM ASWELL AS TO OTHER SYSTEMS.17. CONTRACTOR TO PROVIDE ALL BACKING PLATES AND SUPPORTS FOR ITEMS SUCHAS, BUT NOT LIMITED TO, TOILET ACCESSORIES, TOILET PARTITIONS, MIRRORS,CASEWORK, HANDRAILS, ETC.18. LOCATIONS OF UTILITIES AS SHOWN IN DRAWINGS ARE BASED UPON INFORMATIONINCLUDED IN RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY THE LOCATION OFALL UTILITIES, NOTIFY LOCAL AUTHORITY SERVICE PRIOR TO ANY EXCAVATION SITE. THEARCHITECT WILL NOT BE RESPONSIBLE FOR THE ACCURACY OF THE RECORDDRAWINGS. WHERE CONFLICTS ARISE BETWEEN ACTUAL LOCATION AND DRAWINGS, THEARCHITECT SHALL BE NOTIFIED. U.O.N. ALL UTILITIES SHALL BE PROVIDED ANDINSTALLED UNDERGROUND.19. FIELD VERIFY EMERGENCY ESCAPE AND RESCUE REQUIREMENTS FOR ALL SLEEPINGROOMS AT PROPOSED AND EXISTING WINDOWS.USE OF CONSTRUCTION DOCUMENTS1. CONTRACTOR SHALL NOT SCALE DRAWINGS, ONLY WRITTEN DIMENSIONS OR KEYEDNOTES SHALL BE USED. CONTACT DESIGNER IF CLARIFICATION OR ADDITIONALINFORMATION IS REQUIRED.2. INFORMATION REGARDING EXISTING SYSTEMS, FINISHES AND CONDITIONS WHICH ISSHOWN ON THESE DRAWINGS IS BASED UPON INFORMATION FURNISHED TO THEDESIGNER BY THE OWNER AND/OR PERCEIVED CONDITIONS IN THE FIELD. THEINFORMATION IS NOT INTENDED TO GUARANTEE EXACT CONDITIONS BEFORE WORK ISSTARTED AND CONTRACTOR SHALL NOTIFY THE DESIGNER IF ANY DISCREPANCIES AREFOUND.3. DRAWINGS SHALL NOT BE REPRODUCED FOR SUBMITTALS, DRAWINGS OR PORTIONSOF DRAWINGS USED FOR SUBMITTALS WILL BE REJECTED AND RETURNED TO THECONTRACTOR WITH PRIOR APPROVAL OF DESIGNER.4. DIMENSIONS ARE AS FOLLOWS UNLESS NOTED OTHERWISE: A) FACE OF STUD OR FACE OF WALL B) TO CENTERLINE OF COLUMNS C) TO TOP OF FINISHED FLOOR D) TO BOTTOM OF DECKDEFINITIONS1. "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY LOCATE ANDFINISH FACES IN THE SAME PLANE AND/OR INSTALL NEW CONSTRUCTION ADJACENT TOEXISTING CONSTRUCTION WITHOUT ANY VISIBLE JOINTS OR SURFACE IRREGULARITIES2. "CLEAR" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS NOTADJUSTABLE WITH OUT THE APPROVAL OF THE ARCHITECT. CLEAR DIMENSIONS ARETYPICALLY TO FINISH FACE.3. "MAXIMUM" OR "MAX." AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITIONIS SLIGHTLY ADJUSTABLE BUT MAY NOT VARY TO A DIMENSION OR QUANTITY GREATERTHAN THAT SHOWN WITHOUT APPROVAL OF THE ARCHITECT.4. "MINIMUM" OR "MIN." AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION ISSLIGHTLY ADJUSTABLE BUT MAY VARY TO A DIMENSION OR QUALITY LESS THAN THATSHOWN WITHOUT APPROVAL OF THE ARCHITECT.5. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION ORDIMENSION IS THE SAME OR REPRESENTATIVE FOR SIMILAR CONDITION THROUGHOUT.6. "+/-" AS USED IN THESE DOCUMENTS SHALL MEAN THE DIMENSIONS OR QUALITY ISSLIGHTLY ADJUSTABLE TO ACCOMMODATE ACTUAL CONDITIONSMATERIALS1. ALL DISSIMILAR METAL MATERIALS SHALL BE ISOLATED WITH A NONMETALLICSEPARATOR.2. ALL MATERIALS USED IN THE FIRE-RATED ASSEMBLIES SHALL BE APPROVED BY U.L.OR OTHER RECOGNIZED STANDARDS FOR USE IN SUCH ASSEMBLIES.3. ALL SHEET METAL FLASHING SHALL ALLOW FOR THERMAL MOVEMENT OF THEMATERIAL WITHOUT DEFLECTION AND OILCANNING.SPECIFICATION FOR LOCATION OF DEVICESLAYOUT OF WORK: CONTRACTOR SHALL EXERCISE SPECIAL CARE IN THE VERIFICATIONOF EXISTING CONDITIONS AND DIMENSIONS AND IN THE LAYOUT OF HIS WORK. THEALIGNMENT AND COORDINATION OF THIS WORK WITH ITSELF AND OTHER ADJACENTWORK IS OF PRIMARY IMPORTANCE AND SHOULD TAKE PRECEDENCE OVERDIMENSIONS, ESPECIALLY THOSE INDICATED AS APPROXIMATE. CONTRACTOR SHALLLAYOUT AND VERIFY HIS WORK TO INSURE ALIGNMENT AND FIT, AND REPORT ANYDISCREPANCIES TO THE PROJECT SUPERINTENDENT AND ARCHITECT.LOCATION OF DEVICES IN FINISHED AREAS:A. LOCATION OF WALL DEVICES AS SHOWN ON PLANS IS APPROXIMATE AND FORESTIMATING PURPOSES ONLY.B. WHEN DEVICES BY DIFFERENT TRADES, SUCH AS LIGHTING SWITCHES, THERMOSTATS,ETC. ARE INSTALLED IN THE SAME LOCATION THEY SHALL BE MOUNTED IN ANARRANGEMENT ACCEPTABLE TO THE DESIGNER/OWNER.1. WHEN SHOWN ON THE ARCHITECTURAL PLANS, ELEVATIONS, OR SECTIONS, LOCATEDEVICES AS SHOWN.2. WHEN SHOWN ON THE MECHANICAL OR ELECTRICAL DRAWINGS, BUT NOT ONARCHITECTURAL DRAWINGS, DEVICES SHALL BE UNIFORMLY MOUNTED SO THAT THEYWILL BE SYMMETRICAL VERTICALLY.HORIZONTALLY ALIGN DEVICES UNLESS SEPARATED BY A MINIMUM OF 24"3. DEVICES INSTALLED IN MASONRY OR SURFACES TO RECEIVE WOOD PANEL, WALLCOVERING, OR SIMILAR MATERIALS, SHALL BE INSPECTED BY THE ARCHITECT AT THETIME OF ROUGH-IN.4. WHEN IN DOUBT, CHECK WITH THE ARCHITECT AND/OR OWNER BEFORE ROUGHING.C. DEVIATIONS FROM THE ABOVE PRINCIPLES WITHOUT PRIOR APPROVAL BY THEARCHITECT/OWNER SHALL BE CORRECTED BY THE INSTALLING CONTRACTOR. ANYCOST, INCLUDING CUTTING AND PATCHING, ENTAILED IN THE REMOVAL, RELOCATING ANDREINSTALLATION OF ANY DEVICES SHALL BE THE RESPONSIBILITY OF THATCONTRACTOR.GENERAL NOTES ELEVATIONFD1/8" = 1'-0"FLOOR DRAIN ARROWS INDICATE DIRECTION OF SLOPEHOT WATER HEATERDRAWING SCALE WINDOW : REFER TO PLANS ANDDOOR TYPE, IF APPLICABLE EL. 00.0'EL. 00.0'T.O.W.1A1.1A1.1ATOP OF WALL, PARAPET, ETC. ELEVATION.PAGE NUMBERNEW/FINISH ELEVATIONSECTION CUT NUMBERDETAIL DRAWING NUMBERPAGE NUMBERPAGE NUMBERINTERIOR ELEVATION DRAWING NUMBERSTUD WALL WITH 5/8"NORTH ARROWMASONRY VENEER WALLA-1.1A10110DOOR SIZE (WIDTH X HEIGHT)ELEVATION FOR SIZE, TYPE & LOCATIONWHTOP OF FOUNDATION/ T/F = 0'-0"TYPICAL STUD WALL W/ SOUND INSULATION.DRYWALL EACH SIDE.FROST PROOF HOSE BIBFPHBGAS HOOK UPGASDS. DWG. (E) DRAWING DOWNSPOUT EXISTING C.I.P.CAST IN PLACEA.F.F.APPROX.ABOVE FINISH FLOORAPPROXIMATENOT TO SCALE N.T.S. MFR.MANUFACTURER&ANDCAST IRON CLEAN OUTC.I.C.OF.D. FTG. FOOTING FLOOR DRAIN WWMWELDED WIRE MESHWITHTYP.TYPICALELEV.EQ. ELEC. EXIST.EQUAL EXISTINGELEVATIONELECTRICAL ABBREVIATIONSW/TOP OF FOUNDATIONT/FT/L = 0'-0"DRAWING TITLELEDGE FROM ESTABLISHED ZERO LINESYMBOLS & ABBREV.401.2 COMPLIANCEPROJECTS SHALL COMPLY WITH ONE OF THE FOLLOWING:1.SECTIONS R401 THROUGH R404.2.SECTION R405 AND THE PROVISIONS OF SECTIONS R401 THROUGH R404 INDICATED AS "MANDATORY".3.THE ENERGY RATING INDEX (ERI) APPROACH IN R406.401.3 CERTIFICATEA PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR OTHER APPROVED PARTY AND POSTED ON A WALL IN THE SPACE WHERE THE FURNACE IS LOCATED, AUTILITY ROOM OR AN APPROVED LOCATION INSIDE THE BUILDING. WHERE LOCATED ON AN ELECTRICAL PANEL, THE CERTIFICATE SHALL NOT COVER OR OBSTRUCT THE VISIBILITY OFTHE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT LABEL OR OTHER REQUIRED LABELS.THE CERTIFICATE SHALL INDICATE THE PREDOMINANT R-VALUES OF INSULATIONINSTALLED IN OR ON CEILINGS, ROOF, WALLS, FOUNDATION COMPONENTS SUCH AS SLABS, BASEMENT WALLS, CRAWL SPACE WALLS AND FLOORS AND DUCTS OUTSIDE CONDITIONEDSPACES; U-FACTORS OF FENESTRATION AND THE SOLAR HEAT GAIN COEFFICIENT (SHGC) OF FENESTRATION, AND THE RESULTS FROM ANY REQUIRED DUCT SYSTEM AND BUILDINGENVELOPE AIR LEAKAGE TESTING PERFORMED ON THE BUILDING. WHERE THERE IS MORE THAN ONE VALUE FOR EACH COMPONENT, THE CERTIFICATE SHALL INDICATE THE VALUECOVERING THE LARGEST AREA. THE CERTIFICATE SHALL INDICATE THE TYPES AND EFFICIENCIES OF HEATING, COOLING AND SERVICE WATER HEATING EQUIPMENT. WHERE AGAS-FIRED UNVENTED ROOM HEATER, ELECTRIC FURNACE OR BASEBOARD ELECTRIC HEATER IS INSTALLED IN THE RESIDENCE, THE CERTIFICATE SHALL INDICATE “GAS-FIREDUNVENTED ROOM HEATER," " ELECTRIC FURNACE" OR "BASEBOARD ELECTRIC HEATER," AS APPROPRIATE. AN EFFICIENCY SHALL NOT BE INDICATED FOR GAS-FIRED UNVENTEDHEATERS, ELECTRIC FURNACES AND ELECTRIC BASEBOARD HEATERS.402.1 GENERAL402.1.1 VAPOR RETARDERWALL ASSEMBLIES IN THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH THE VAPOR REATRDER REQUIREMENTS OF SECTION R702.7 OF THE INTERNATIONAL RESIDENTIALCODE OR SECTION 1405.3 OF THE INTERNATIONAL BUILDING CODE, AS APPLICABLE.402.1.2 INSULATION AND FENESTRATION CRITERIACLIMATE ZONE 5 (PER TABLE 402.1.2):FENESTRATION U-FACTOR IS TO BE 0.30 OR BETTERSKYLIGHT U-FACTOR IS TO BE 0.55 OR BETTERCEILING MINIMUM R-49EXTERIOR WOOD FRAME WALL MINIMUM R20FLOOR MINIMUM R-30BASEMENT WALL MINIMUM R-10/13SLAB MINIMUM R-10CRAWLSPACE WALL MINIMUM R-15402.1.3 R-VALUE COMPUTATIONINSULATION MATERIAL USED IN LAYERS, SUCH AS FRAMING CAVITY INSULATION OR CONTINUOUS INSULATION, SHALL BE SUMMED TO COMPUTE THE CORRESPONDING COMPONENTR-VALUE FOR OTHER BUILDING MATERIALS OR AIR FILMS. WHERE INSULATED SIDING IS USED FOR THE PURPOSE OF COMPLYING WITH THE CONTINUOUS INSULATION REQUIREMENTSOF TABLE R402.1.2, THE MANUFACTURER'S LABELED R-VALUE FOR THE INSULATED SIDING SHALL BE REDUCED BY R-0.6.CLIMATE ZONE 5 (PER TABLE 402.1.4):FENESTRATION U-FACTOR IS TO BE 0.30 OR BETTERSKYLIGHT U-FACTOR IS TO BE 0.55 OR BETTERCEILING U-FACTOR IS TO BE 0.026 OR BETTEREXTERIOR WOOD FRAME WALL U-FACTOR IS TO BE 0.060 OR BETTERFLOOR U-FACTOR IS TO BE 0.033 OR BETTERBASEMENT WALL U-FACTOR IS TO BE 0.059 OR BETTERCRAWLSPACE WALL U-FACTOR IS TO BE 0.055 OR BETTER402.1.4 U-FACTOR ALTERNATIVEAN ASSEMBLY WITH A U-FACTOR EQUAL TO OR LESS THAN THAT SPECIFIED IN TABLE 402.1.4 SHALL BE PERMITTED AS AN ALTERNATIVE TO THE R-VALUE IN TABLE 402.1.2.402.1.5 TOTAL UA ALTERNATIVEWHERE THE TOTAL BUILDING THERMAL ENVELOPE UA, THE SUM OF U-FACTOR TIMES ASSEMBLY AREA, IS LESS THAN OR EQUAL TO THE TOTAL UA RESULTING FROM MULTIPLYINGTHE U-FACTORS IN TABLE R402.1.4 BY THE SAME ASSEMBLY AREA AS IN THE PROPOSED BUILDING, THE BUILDING SHALL BE CONSIDERED TO BE IN COMPLIANCE WITH TABLER402.1.2 THE UA CALCULATION SHALL BE PERFORMED USING A METHOD CONSISTENT WITH THE ASHRAE HANDBOOK OF FUNDAMENTALS AND SHALL INCLUDE THE THERMALBRIDGING EFFECTS OF FRAMING MATERIALS. IN ADDITION TO UA COMPLIANCE, THE SHGC REQUIREMENTS SHALL BE MET.402.2 SPECIFIC INSULATION REQUIREMENTS402.2.1 CEILINGS WITH ATTIC SPACESWHERE SECTION R402.1.2 REQUIRES R-49 INSULATION IN THE CEILING, INSTALLING R-38 OVER 100 PERCENT OF THE CEILING AREA REQUIRING INSULATION SHALL SATISFY THEREQUIREMENT FOR R-49 INSULATION WHEREVER THE FULL HEIGHT OF UNCOMPRESSED R-38 INSULATION EXTENDS OVER THE WALL TOP PLATE AT THE EAVES. THIS REDUCTIONSHALL NOT APPLY TO THE U-FACTOR ALTERNATIVE APPROACH IN SECTION 402.1.4 AND THE TOTAL UA ALTERNATIVE IN SECTION 402.1.5.402.2.2 CEILINGS WITHOUT ATTIC SPACEWHERE SECTION R402.1.2 REQUIRES INSULATION R-VALUE GREATER THAN R-30 IN THE CEILING AND THE DESIGN OF THE ROOF/CEILING ASSEMBLY DOES NOT ALLOW SUFFICIENTSPACE FOR THE REQUIRED INSULATION, THE MINIMUM REQUIRED INSULATION R-VALUE FOR SUCH ROOF/CEILING ASSEMBLIES SHALL BE R-30. INSULATION SHALL EXTEND OVER THETOP OF THE WALL PLATE TO THE OUTER EDGE OF SUCH PLATE AND SHALL NOT BE COMPRESSED. THIS REDUCTION OF INSULATION FROM THE REQUIREMENTS OF SECTION 402.1.2SHALL BE LIMITED TO 500 SQ. FT. OR 20% OF THE TOTAL INSULATED CEILING AREA, WHICHEVER IS LESS. THIS REDUCTION SHALL NOT APPLY TO THE U-FACTOR ALTERNATIVEAPPROACH IN SECTION R402.1.4 AND THE TOTAL UA ALTERNATIVE IN SECTION R402.1.5.402.2.3 EAVE BAFFLEFOR AIR-PERMEABLE INSULATIONS IN VENTED ATTICS, A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT AND EAVE VENTS. BAFFLES SHALL MAINTAIN AN OPENING EQUAL ORGREATER THAN THE SIZE OF THE VENT. THE BAFFLE SHALL EXTEND OVER THE TOP OF THE ATTIC INSULATION. THE BAFFLE SHALL BE PERMITTED TO BE ANY SOLID MATERIAL.402.2.4 ACCESS HATCHES AND DOORSACCESS DOORS FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SUCH AS ATTICS AND CRAWL SPACES SHALL BE WEATHER STRIPPED AND INSULATED TO A LEVELEQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES. ACCESS THAT PREVENTS DAMAGING OR COMPRESSING THE INSULATION SHALL BE PROVIDED TO ALLEQUIPMENT. WHERE LOOSE-FILL INSULATION IS INSTALLED, A WOOD-FRAMED OR EQUIVALENT BAFFLE OR RETAINER SHALL BE INSTALLED TO PREVENT THE LOOSE-FILLINSULATION FROM SPINNING INTO THE LIVING SPACE WHEN THE ATTIC ACCESS IS OPENED. THE BAFFLE OR RETAINER SHALL PROVIDE A PERMANENT MEANS OF MAINTAINING THEINSTALLED R-VALUE OF THE LOOSE-FILL INSULATION.EXCEPTION: VERTICAL DOORS PROVIDING ACCESS FROM CONDITIONED SPACES THAT COMPLY WITH THE FENESTRATION REQUIREMENTS OF TABLE R402.1.2 BASED ON THEAPPLICABLE CLIMATE ZONE SPECIFIED IN CH. 3.402.2.8 FLOORSFLOOR FRAMING-CAVITY INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE OF THE SUBFLOOR DECKING.402.2.9 BASEMENT WALLSWALLS ASSOCIATED WITH CONDITIONED BASEMENTS SHALL BE INSULATED FROM THE TOP OF THE BASEMENT WALL DOWN TO 10' BELOW GRADE OR TO THE BASEMENT FLOOR,WHICHEVER IS LESS. WALLS ASSOCIATED WITH UNCONDITIONED BASEMENTS SHALL COMPLY WITH THIS REQUIREMENT EXCEPT WHERE THE FLOOR OVERHEAD IS INSULATED INACCORDANCE WITH SECTIONS R402.1.2 AND R402.2.8.402.2.10 SLAB-ON-GRADE FLOORSSLAB-ON-GRADE FLOORS WITH A FLOORS SURFACE LESS THAN 12" BELOW GRADE SHALL BE INSULATED IN ACCORDANCE WITH TABLE 402.1.2. THE INSULATION SHALL EXTENDDOWNWARD FROM THE TOP OF THE SLAB ON THE OUTSIDE OR INSIDE OF THE FOUNDATION WALL. INSULATION LOCATED BELOW GRADE SHALL BE EXTENDED THE DISTANCEPROVIDED IN TABLE R402.1.2. BY ANY COMBINATION OF VERTICAL INSULATION, INSULATION EXTENDING UNDER THE SLAB OR INSULATION EXTENDING OUT FROM THE BUILDING.INSULATION EXTENDING AWAY FROM THE BUILDING SHALL BE PROTECTED BY PAVEMENT OR BY NOT LESS THAN 10" OF SOIL. THE TOP EDGE OF THE INSULATION INSTALLEDBETWEEN THE EXTERIOR WALL AND THE EDGE OF THE INTERIOR SLAB SHALL BE PERMITTED TO BE CUT AT A 45° ANGLE AWAY FROM THE EXTERIOR WALL. SLAB-EDGEINSULATION IS NOT REQUIRED IN JURISDICTIONS DESIGNATED BY THE CODE OFFICIAL AS HAVING A VERY HEAVY TERMITE INFESTATION.402.2.11 CRAWL SPACE WALLSAS AN ALTERNATIVE TO INSULATING FLOORS OVER CRAWL SPACE, CRAWL SPACE WALLS SHALL BE INSULATED PROVIDED THAT THE CRAWL SPACE IS NOT VENTED TO THEOUTDOORS. CRAWL SPACE WALL INSULATION SHALL BE PERMANENTLY FASTENED TO THE WALL AND SHALL EXTEND DOWNWARD FROM THE FLOOR TO THE FINISHED GRADEELEVATION AND THE VERTICALLY OR HORIZONTALLY FOR NOT LESS THAN AN ADDITIONAL 24". EXPOSED EARTH IN UNVENTED CRAWL SPACE FOUNDATIONS SHALL BE COVEREDWITH A CONTINUOUS CLASS I VAPOR RETARDER IN ACCORDANCE WITH THE INTERNATIONAL RESIDENTIAL CODE, AS APPLICABLE. JOINTS OF THE VAPOR RETARDER SHALLOVERLAP BY 6" AND BE SEALED OR TAPED. THE EDGES OF THE VAPOR RETARDER SHALL EXTEND NOT LESS THAN 6" UP STEM WALLS AND SHALL BE ATTACHED TO THE STEMWALLS.402.2.12 MASONRY VENEERINSULATION SHALL NOT BE REQUIRED ON THE HORIZONTAL PORTION OF A FOUNDATION THAT SUPPORTS A MASONRY VENEER402.3 FENESTRATION402.3.1 U-FACTORAN AREA AVERAGE OF FENESTRATION PRODUCTS SHALL BE PERMITTED TO SATISFY THE U-FACTOR REQUIREMENTS.402.4 AIR LEAKAGE402.4.1 BUILDING THERMAL ENVELOPETHE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH SECTIONS R402.4.1.1 AND R402.4.1.2. THE SEALING METHODS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FORDIFFERENTIAL EXPANSION AND CONTRACTION.402.4.1.1 INSTALLATIONTHE COMPONENTS OF THE BUILDING THERMAL ENVELOPE AS INDICATED IN TABLE R402.4.1.1 SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURE'S INSTRUCTIONS ANDTHE CRITERIA INDICATED IN TABLE R402.4.1.1. AS APPLICABLE TO THE METHOD OF CONSTRUCTION. WHERE REQUIRED BY THE CODE OFFICIAL, AN APPROVED THIRD PARTYSHALL INSPECT ALL COMPONENTS AND VERIFY COMPLIANCE.1.ALL JOINTS, SEAMS AND PENETRATIONS.2.SITE-BUILT WINDOWS, DOORS AND SKYLIGHTS.3.OPENINGS BETWEEN WINDOW AND DOOR ASSEMBLIES AND THEIR RESPECTIVE JAMBS AND FRAMING.4.UTILITY PENETRATIONS.5.DROPPED CEILINGS OR CHASES ADJACENT TO THE THERMAL ENVELOPE.6.KNEE WALLS.7.WALLS AND CEILINGS SEPARATING A GARAGE FROM CONDITIONED SPACES.8.BEHIND TUBS AND SHOWERS ON EXTERIOR WALLS.9.COMMON WALL BETWEEN DWELLING UNITS.10.ATTIC ACCESS OPENINGS.11.RIM JOIST JUNCTION.12.OTHER SOURCES OF INFILTRATION402.4.2 FIREPLACESNEW WOOD-BURNING FIREPLACES SHALL HAVE TIGHT-FITTING FLUE DAMPERS OR DOORS, AND OUTDOOR COMBUSTION AIR. WHERE TIGHT-FITTING DOORS ON FACTORY-BUILTFIREPLACES LISTED AND LABELED IN ACCORDANCE WITH UL 127, THE DOORS SHALL BE TESTED AND LISTED FOR THE FIREPLACE.402.4.3 FENESTRATION AIR LEAKAGEWINDOWS, SKYLIGHTS AND SLIDING GLASS DOORS SHALL HAVE AN AIR INFILTRATION RATE OF NOT GREATER THAN 0.3 CFM PER SQ. FT., AND FOR SWINGING DOORS, NOTGREATER THAN 0.5 CFM PER SQ. FT., WHEN TESTED IN ACCORDANCE TO NFRC 400 OR AAMA/WDMA/CSA 101/I.S.2/A440 BY AN ACCREDITED, INDEPENDENT LABORATORYAND LISTED AND LABELED BY THE MANUFACTURER.402.4.5 RECESSED LIGHTINGRECESSED LUMINARIES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND UNCONDITIONED SPACES.RECESSED LUMINARIES SHALL BE IC-RATED AND LABELED AS HAVING AN AIR LEAKAGE RATE OF NOT GREATER THAN 2.0 CFM WHEN TESTED IN ACCORDANCE WITH ASTM E 283AT A PRESSURE DIFFERNTIAL OF 1.57 PSF . RECESSED LUMINARIES SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND THE INTERIOR WALL OR CEILINGCOVERING.402.5 MAXIMUM FENESTRATION U-FACTOR AND SHGCTHE AREA-WEIGHTED AVERAGE MAXIMUM FENESTRATION U-FACTOR PERMITTED USING TRADE-OFFS FROM SECTION 402.1.5 OR 405 SHALL BE 0.48 IN ZONES 4 AND 5 AND 0.40IN ZONES 6 THROUGH 8 FOR VERTICAL FENESTRATION, AND 0.75 IN ZONES 4 THROUGH 8 FOR SKYLIGHTS. THE AREA-WEIGHTED AVERAGE MAXIMUM FENESTRATION SHGCPERMITTED USING TRADE-OFFS FROM SECTION R405 IN CLIMATE ZONES 1 THROUGH 3 SHALL BE 0.50.403.1 CONTROLSNOT LESS THAN ONE THERMOSTAT SHALL BE PROVIDED FOR EACH SEPARATE HEATING AND COOLING SYSTEM.403.3 DUCTS403.3.1 INSULATIONSUPPLY AND RETURN DUCTS IN ATTICS SHALL BE INSULATED TO AN R-VALUE OF NOT LESS THAN R-8 FOR DUCTS 3 INCHES IN DIAMETER AND LARGER AND NOT LESS THAN R-6FOR DUCTS SMALLER THAN 3 INCHES IN DIAMETER. SUPPLY AND RETURN DUCTS IN OTHER PORTIONS OF THE BUILDING SHALL BE INSULATED TO NOT LESS THAN R-6 FOR DUCTS 3INCHES IN DIAMETER AND NOT LESS THAN R-4.2 FOR DUCTS SMALLER THAN 3 INCHES IN DIAMETER.403.2.2 SEALINGDUCTS, AIR HANDLERS, FILTER BOXES SHALL BE SEALED. JOINTS AND SEAMS SHALL COMPLY WITH EITHER THE INTERNATIONAL MECHANICAL CODE OR INTERNATIONALRESIDENTIAL CODE, AS APPLICABLE. 403.3.3 DUCT TESTING1.ROUGH-IN TEST: TOTAL LEAKAGE SHALL BE MEASURED WITH A PRESSURE DIFFERENTIAL OF 0.1 INCH W.G. ACROSS THE SYSTEM, INCLUDING THE MANUFACTURER'S AIR HANDLERENCLOSURE IF INSTALLED AT THE TIME OF THE TEST. REGISTERS SHALL BE TAPED OR OTHERWISE SEALED DURING THE TEST.2.POST CONSTRUCTION TEST: TOTAL LEAKAGE SHALL BE MEASURED WITH A PRESSURE DIFFERENTIAL OF 0.1 INCH W.G. ACROSS THE ENTIRE SYSTEM, INCLUDING THEMANUFACTURER'S AIR HANDLER ENCLOSURE. REGISTERS SHALL BE TAPED OR OTHERWISE SEALED DURING THE TEST.EXCEPTIONS: A DUCT AIR-LEAKAGE TEST SHALL NOT BE REQUIRED WHERE THE DUCTS AND AIR HANDLERS ARE LOCATED ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE. ADUCT AIR-LEAKAGE TEST SHALL NOT BE REQUIRED FOR DUCTS SERVING HEAT OR ENERGY RECOVERY VENTILATORS THAT ARE NOT INTEGRATED WITH DUCTS SERVING HEATINGOR COOLING SYSTEMS.403.3.5 BUILDING CAVITIESBUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS.403.4 MECHANICAL SYSTEM PIPING INSULATIONMECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS GREATER THAN 105°F OR LESS THAN 55°F SHALL BE INSULATED TO AN R-VALUE OF NOT LESS THAN R-3. 403.4.1 PROTECTION OF PIPING INSULATIONPIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT CAUSED BY SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND WIND. THEPROTECTION SHALL PROVIDE SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. ADHESIVE TAPE SHALL BE PROHIBITED.403.5 SERVICE HOT WATER SYSTEMSENERGY CONSERVATION MEASURES FOR SERVICE HOT WATER SYSTEMS SHALL BE IN ACCORDANCE WITH SECTIONS R403.5.1 THROUGH R403.5.4.403.5 CIRCULATING HOT WATER SYSTEMSALL CIRCULATING SERVICE HOT WATER PIPING SHALL BE INSULATED TO AT LEAST R-2. CIRCULATING HOT WATER SYSTEMS SHALL INCLUDE AN AUTOMATIC OR READILYACCESSIBLE MANUAL SWITCH THAT CAN TURN OFF THE HOT WATER CIRCULATING PUMP WHEN THE SYSTEM IS NOT IN USE.403.5.3 HOT WATER PIPE INSULATION (PRESCRIPTIVE)INSULATION FOR HOT WATER PIPING WITH A THERMAL RESISTANCE, R-VALUE, OF NOT LESS THAN R-3 SHALL BE APPLIED TO THE FOLLOWING:1. PIPING 34 INCH AND LARGER IN NOMINAL DIAMETER.2. PIPING SERVING MORE THAN ONE DWELLING UNIT.3. PIPING LOCATED OUTSIDE THE CONDITIONED SPACE.4. PIPING FROM THE WATER HEATER TO A DISTRIBUTION MANIFOLD.5. PIPING LOCATED UNDER A FLOOR SLAB.6. BURIED PIPING.7. SUPPLY AND RETURN PIPING IN RETICULATION SYSTEMS OTHER THAN DEMAND RE-CIRCULATION SYSTEMS.ALL REMAINING PIPING SHALL BE INSULATED TO AT LEAST R-3 OR MEET THE RUN LENGTH REQUIREMENTS OF TABLE R403.4.2.403.6 MECHANICAL VENTILATIONTHE BUILDING SHALL BE PROVIDED WITH VENTILATION THAT COMPLIES WITH THE REQUIREMENTS THIS SECTION OR INTERNATIONAL MECHANICAL CODE, AS APPLICABLE, OR WITHOTHER APPROVED MEANS OF VENTILATION. OUTDOOR AIR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN THE VENTILATIONSYSTEM IS NOT OPERATING.403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYFANS USED TO PROVIDE WHOLE-HOUSE MECHANICAL VENTILATION SHALL MEET THE EFFICACY REQUIREMENTS OF TABLE R403.6.1EXCEPTION: WHERE AN AIR HANDLER THAT IS INTEGRAL TO TESTED AND LISTED HVAC EQUIPMENT IS USED TO PROVIDE WHOLE-HOUSE MECHANICAL VENTILATION, THE AIRHANDLER SHALL BE POWERED BY AN ELECTRONICALLY COMMUTATED MOTOR403.7 EQUIPMENT SIZING AND EFFICIENCY RATINGHEATING AND COOLING EQUIPMENT SHALL BE SIZED IN ACCORDANCE WITH ACCA MANUAL S BASED ON BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OROTHER APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES. NEW OR REPLACEMENT HEATING AND COOLING EQUIPMENT SHALL HAVE AN EFFICIENCY RATINGEQUAL TO OR GREATER THAN THE MINIMUM REQUIRED BY FEDERAL LAW FOR THE GEOGRAPHIC LOCATION WHERE THE EQUIPMENT IS INSTALLED.R404.1 LIGHTING EQUIPMENTNOT LESS THAN 90 PERCENT OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH-EFFICACY LAMPS.R404.1.1 LIGHTING EQUIPMENTFUEL GAS LIGHTING SYSTEMS SHALL NOT HAVE CONTINUOUSLY BURNING PILOT LIGHTS.IECC RESIDENTIAL PRESCRIPTIVE CODE ADDRESS:10404 DITCH ROAD CARMEL INLOT SIZE435,593MIN AREA15,000MIN LOT WIDTH120FRONT YARD SETBACK40'SIDE YARD SETBACK10' MIN 30 ' TOTALREAR YARD SETBACK20'MAXIMUM LOT COVERAGE 35% =152,457MAX HEIGHT 35' (TO MIDPOINT OF GABLE FROM GROUND LEVEL )MAX ACCESSORY HEIGHT18'PAVEMENT SQUARE FOOTAGES:HOUSE DRIVEWAY AREA 1,712 SFBARN PAVEMENT AREA 798 SFGUEST HOUSE PAVEMENT AREA 943 SF