HomeMy WebLinkAboutNEZ AD3.series-Fire Rated Details-AD3.8 2015_2018\A1;5/8" TYP
\A1;2x_ FIRE
\A1;{\H1x;GABLE END OR
\A1;LINE OF ROOF OVERH
\A1;LINE OF
FIRE BLOCKING AT ROOF TYP. OFFSET EXT. WALL - 1 HR
SCALE 3/4" = 1'-0"
\A1;{\L\C6;NOT
1 HOUR RATED
\A1;
9
DRAINAGE PLANE BEHIND SIDING
DRAINAGE PLANE BEHIND SIDING
RIM BOARD PER STRUC.
SLAB ON GRADE / GARAGE FOUNDATION
SHEATHING PER STRUC.
FINISHED GRADE
SHEATHING PER STRUC.
DRAINAGE PL
SIDING PER
SCALE: 2-1/2" =
FLASHING DETAIL
1 LAYER OF
SHEATHING P
\A1;
PT 2x4 TREATED PLATE OVER SILL SEALER W/ ANCHOR BOLTS
REINFORCED CONCRETE SLAB
DRAINAGE PLANE BEHIND SIDING
SHEATHING PER STRUC.
1 LAYER OF 5/8" GYP BD., PER ASSEMBLY - CONTINUOUS TO
1 LAYER OF 5/8" GYP BD., PER ASSEMBLY - CONTINUOUS TO
FINISHED GRADE
1 LAYER OF 5/8" GYP. BD., PER A
REF. FLOOR
FRAMING PLAN
SEAL ALL PE
W/ FIRE CAU
1 LAYER OF
\A1;
2x BLOCKING @ PLATES, TYP.
EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.
EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.
8
A
1/2" DRYWALL PER SPEC.
2x FRAMING PER PLAN, REFER TO STRUC.
INSULATION PER ENERGY CALC'S.
1 HOUR RATED ASSEMBLY UL#U338
1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356
5/8" DRYWALL PER SPEC.
1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR
2" X 6" BENT FLASHING/DRIP EDGE
2x FRAMING PER PLAN, REFER TO STRUC.
(2) 2x SILL PLATE (1 + 1 P.T.) OVER SILL SEALER @ 8'-0" BSMT.\P(1
2x FRAMING PER PLAN, REFER TO STRUC.
\A1;CONCRETE SLAB OVER VAPOR BARRIER {\L\O\C7;(PER 2009, 2012, 20
FOUNDATION AND FOOTING WALL, REFER TO SHEED AD2.0
INSULATION PER ENERGY CALC'S.
1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY
1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR
1 LAYER OF 5/8" GYP. BD. CONTINUOUS TO THE UNDERSIDE OF THE FLOOR
1 LAYER OF 5/8" GYP. BD., PER ASSEMBLY
PROVIDE 2x BLOCKING @ PLATES, TYP.
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
2x BLOCKING IN BETWEEN ROOF TRUSSES AS REQ'D.
\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH
\A1;T&G FLOOR SHEATHING, GLUE PER SPEC. & ATTACH PER STRUC.
\A1;T&G FLOOR SHEATHING, GLUE P
SEAL ALL PERIMETER JOINTS W/ F
FLOOR SYSTEM\PPER STRUCTURAL
FLOOR SYSTEM\PPER STRUCTURAL
1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\PUL#U356
1 HOUR RATED ASSEMBLY \PUL#U305\PUL#U344\P
1 HOUR RATED ASSEMBLY
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
{\LNOTE}:\PREFER TO AD2.0 SHEETS FOR AIR BARRIER SEALA
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
FOUNDATION WALL REF. TO SHEET AD2.0
DRAINAGE PLANE BEHIND SIDING
EXTERIOR TRIM TO BE APPLIED PER COMMUNITY SPECS.
GABLE END TRUSS W/ VERTICALS @ 24" O.C.
2x4 BLOCKING
TYPICAL ROOF RETURN
2" X 6" BENT FLASHING/DRIP EDGE
\A1;
A
A
A
A
A
SHEATHING PER STRUC.
1/2" DRYWALL PER SPEC.
INSULATION PER ENERG
SEAL ALL PERIMETER JOINTS W/
\A1;T&G FLOOR SHEATHING, GLUE
FLOOR SYSTEM\PPER STRUCTURA
DRAFT STOP - BLK'G. W/ AIR BA
RIM BOARD PER STRUC.
SOFFIT PER SPEC.
EXTEND J-MOULD/START
{\LNOTE}:\PREFER TO
(2) 2x SILL PLATE (1 + 1 P.T.)
PROVIDE 2x BLOCKING @ PLATES, TYP.
SEAL ALL PERIMETER JOINTS W/ FIRE CAULK
{\LNOTE}:\PAT 2-HOUR FIRE SEPARATION EXTERIOR WALL OFF
\A1;1" MIN.
STARTER STR
5/8" DRYWALL PER SPEC.
ATTIC INSULATION PER ENERGY CALC'S., TYP.
ATTIC INSULATION PER ENERGY CALC'S., TYP.
PROVIDE 2x VERTICAL FURRING \PIN BETWEEN ROOF TRUSSES AS REQ'D
INGROUND CONDITION
3 {\H0.77778x;(PERPENDICULA
INGROUND CONDITION
2 {\H0.77778x;(PARALLEL FRAMING)}
1
INTERMEDIATE FLOORS
4
CANTILEVERED FLOOR CONDITION
5 {\H0.77778x;(PARALLEL FRAM
EAVE OVERHANG CONDITION
6
GABLE END CONDITION
7
PLAN
SHEET
PRODU
RELEA
DATE
NPC P
LAWSO
LEGAC
REV #
NOTE:
CURRE
05/
JL
(c) Co
STD DETAILS
150 Allen Rd, Suite 303
Basking Ridge, New Jersey 07920
Northeast Zone Office
PLOTTED: Aug. 24, 21 / Jeffrey Moskovciak / AD3.8 2015_2018
Fire Blocking Details at Roof
Cornice Returns and Building Offsets
1HR - FIRE RATED ASSEMBLY WALL SECTIONS AD3.8
A SCALE :3/4" = 1'-0"
NOT USED
NOT USED
NOT USED
08/10/22