Loading...
HomeMy WebLinkAboutIN Wall Sections Sheathing Overhang-AD 2.7PLOTTED: September 30, 2021 / Michael Urban / IN WALL SECTIONS SH AD 2.7 Typical Wall Sections Porch Foundation Indianapolis Division Indiana Division 11590 North Meridian Street, Suite 530 Carmel, Indiana 46032 . . . . . . . . . . . . . . . . . . . . . . . . . . . PLAN SHEET PRODU DATE NPC P LAWSO GARAG REV # NOTE: INITI CURRE (c) C Rick 06/21 ---- -------------- -- -- 06/21 \A1;8'-0" \A1;OPT. 9'-0" \A1;PER STRUCTURAL PLANS \A1;9'-1{\H0.750000x;\S1#8;}" RIM BOARD PER ENGINEERING FLOOR SYSTEM PER STRUCTURAL PLANS TOP OF FOUNDATION TOP OF 1ST FLOOR 3/4" T&G SUBFLOOR OVER FLOOR JOIS CONT. CAULK BEAD BASE TRIM PER SPEC. CONT. ADHESIVE BEAD POURED CONC. WALL PER STRUCTURAL FELT PAPER OVER BUILDING WRAP OVER SHEATHING INSULATION R-15 TREATED SILL PLATE OVER SILL SEAL 1/2" DRYWALL @ BASEMENT CEILING AS REQ'D BY C \A1;QUEEN BRICK VENEER \A1;RUBBERIZED THRU-WALL FLASHING - BLDG WRAP PROVIDE WEEP HOLES @ 24 O.C. WITH SOLID GROUT MOISTURE BARRIER INSULATION R-11 VINYL BLANKET \A1;4'-0" INSULATION SLOPE PER PLAN \A1;3{\H0.750000x;\S1#2;}" D SC. 1-1/2" = 1'-0" SIDING AND TRIM PER ELEVATION TYPICAL PORCH FOUNDATION SECTION w/ BASEMENT \A1;8'-0" \A1;OPT. 9'-0" \A1;PER STRUCTURAL PLANS \A1;9'-1{\H0.750000x;\S1#8;}" RIM BOARD PER ENGINEERING FLOOR SYSTEM PER STRUCTURAL PLANS TOP OF FOUNDATION TOP OF 1ST FLOOR 3/4" T&G SUBFLOOR OVER FLOOR JOIST., ATTACHMENT PER CONT. CAULK BEAD BASE TRIM PER SPEC. CONT. ADHESIVE BEAD POURED CONC. WALL PER STRUCTURAL DETAILS BUILDING WRAP OVER SHEATHING PER SPEC OVER 2x4 FRAMING INSULATION R-15 TREATED SILL PLATE OVER SILL SEALER. ANCHORAGE PER SIDING PER ELEVATION 1/2" DRYWALL @ BASEMENT CEILING AS REQ'D BY CODE MOISTURE BARRIER INSULATION R-11 VINYL BLANKET \A1;4'-0" INSULATION SLOPE PER PLAN \A1;3{\H0.750000x;\S1#2;}" BITUMINOUS WATERPROOFING PER SPEC. ON CEMENTIT BACKFILL TO BE FREE OF ORGANIC MATERIAL, CONST UNDISTURBED SOIL FINISHED GRADE TRENCH FOOTING PER STRUCTURAL SLOPE PER PLAN \A1;2'-10" - OR TO MIN. FROST DEPTH B SC. 1-1/2" = 1'-0" TYPICAL PORCH FOUNDATION SECTION C SC. 1-1/2" = 1'-0" BRICK VENEER AND TRIM PER ELEVATION TYPICAL PORCH FOUNDATION SECTION W/ BASEMENT TOP OF FOUNDATI BUILDING WRAP OVER SHEATHI TREATED SILL PL SIDING PER ELEVATION MOISTURE BARRIER \A1;3{\H0.750000x;\ POURED CONC. WA BRICK/STONE VENEER, INSTAL \A1;PER \A1;STRUCTU \A1;PER STRUCTURAL P BITUMINOUS WATERPROOFING PE BACKFILL TO BE FREE OF ORGA UNDISTURBED SOIL CONTINUOUS CON \A1;PER STRUCTURAL\P POURED CONC. F A SC. 1-1/2" = 1'-0" SIDING AND TRIM PER ELEVATION TYPICAL PORCH/GARAGE FOUNDATION SECTION TOP OF SLAB \A1;2" x 5{\H0.7x;\S1/2;}" SLAB LEDGE CONT. CAULK BEAD BASE TRIM PER SPEC. CONT. ADHESIVE BEAD INSULATION R-15 \A1;1'-4" \A1;2'-10" - OR TO MIN. FROST DEPTH \A1;1'-0" \A1;TYP. CONC. SLAB PER DET. 1 - SD.04 \A1;2'-0" INSULATION \A1;RIGID INSULATION R-10\PHORIZONTAL OR VERTICAL AS \A1;6" \A1;TYP. TRENCHED FTG\PSEE DET. 1\PSHEET SD.04 \A1;5{\H0.75x;\S1#2;}" \A1;2" \A1;\A1;3" 3" \A1;{\H0.7x;\S1/2;}" HIGH DENSITY RIGID\PINSULATION SLOPE PER PLAN \A1;4" E SC. 1-1/2" = 1'-0" TYPICAL PORCH/SLAB ON GRADE SECTION BUILDING WRAP OVER SHEATHING PER SPEC OVER 2x4 FRAMING SIDING PER ELEVATION BRICK/STONE VENEER, INSTALL PER MANUFACTURE. SEE ELEVATION A SC. 1-1/2" = 1'-0" SIDING AND TRIM PER ELEVATION TYPICAL PORCH/GARAGE FOUNDATION SECTION w/ SLAB TREATED SILL PL BUILDING WRAP OVER SHEATH SIDING PER ELEVATION POURED CONC. WA CONTINUOUS CON \A1;4" \A1;3{\H0.75x;\S1# BRICK/STONE VENEER, INSTA 08/10/22