HomeMy WebLinkAboutA100.8TT2'-0"8'-1 1/8" (EXISTING)EXISTING 12"W X 24"D CONCRETE TRENCH FOOTING TO REMAIN IN-PLACE, AS-IS
EXISTING (2) COURSES 8" X 8" X 16' CMU TO REMAIN IN-PLACE, AS-IS
EXISTING (1) COURSE 4" X 8" X 16' CMU TO REMAIN IN-PLACE, AS-IS
EXISTING UNDISTURBED SOIL TO REMAIN IN-PLACE, AS-IS
NEW 4"T CAST-IN-PLACE CONCRETE SLAB
NEW & EXISTING COMPACTED GRAVEL FILL
NEW 2" FOAM INSULATION FROM TOP OF NEW SLAB TO MIN. 24" BELOW EXISTING GRADE
NEW 1/2" DIA. ANCHOR BOLT @ 72" O/C & WITHIN 12" OF END OF WALL
NEW TREATED 2X4 BOTTOM PLATE
EXISTING 2-PLY 1-3/4"W X 11-7/8"H LVL CLEAR SPAN HEADER TO REMAIN IN-PLACE, AS-IS
EXISTING DOUBLE 2X4 TOP PLATE TO REMAIN IN-PLACE, AS-IS
NEW 2X4 WALL STUDS @ 16" O/C
NEW R-15 KRAFT-FACED BATT INSULATION
NEW 7/16" OSB WALL SHEATHING
NEW TYVEK (OR EQUIV.) HOUSEWRAP WITH TAPED SEAMS
NEW FIBER CEMENT SIDING TO MATCH EXISTING AS CLOSELY AS POSSIBLE
NEW 1/2" DRYWALL ON INSIDE FACE OF WALL STUDS
EXISTING ENGINEERED SCISSOR TRUSSES @ 24" O/C TO REMAIN IN-PLACE, AS-IS
NEW 5/8" DRYWALL ON BOTTOM CHORD OF TRUSSES
EXISTING FASCIA, SOFFIT, & GUTTER TO REMAIN IN-PLACE, AS-IS
#0
of
15
Date:
Sheet:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use andshould not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.Young ResidenceJohn and Melissa1076 Saratoga CircleCarmel, Indiana 46280Approved By:
Date:
A601
PERMIT
Maggie Smith
Senior Designer
msmith@caseindy.com
Craig Dice
Architectural Designer
cdice@caseindy.com
3.24.22
Dawn Ashburn
Project Developer
dashburn@caseindy.com
4.01.22#1
8.02.22#2
EXTERIOR WALL SECTION
SCALE: 3/4" = 1'08/11/22