Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3500 Elev C TRS[408977]
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). May 2,2022 Garcia, Juan Pages or sheets covered by this seal: I51673291 thru I51673379 My license renewal date for the state of Indiana is July 31, 2022. 3500_Elev_C 3500 Elev C IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG01 Truss Type Diagonal Hip Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673291 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:49:55 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-jD98_JfkfRZQc13VAxxDr9AHGF5RvEHmvRLyrDzLryw Scale = 1:16.2 1 2 3 4 5 10 9 8 7 6 11 12 3x6 2x4 2x4 2x4 3x4 3x4 0-0-80-0-8 3-5-53-4-13 4-11-01-5-11 -1-6-12 1-6-12 3-5-5 3-5-5 4-11-0 1-5-11 0-8-82-6-62-8-21-8-21-0-04.80 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.30 0.16 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.02 (loc) 9 9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-4-13, 7=Mechanical Max Horz 10=69(LC 5) Max Uplift 10=-50(LC 4), 7=-25(LC 8) Max Grav 10=318(LC 1), 7=178(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-10=-272/57 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 50 lb uplift at joint 10 and 25 lb uplift at joint 7. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 23 lb down and 25 lb up at 1-7-4, and 3 lb down and 3 lb up at 2-5-6 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-20, 9-10=-20, 6-8=-20 Concentrated Loads (lb) Vert: 11=-23(B) 12=3(F) May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG02 Truss Type Diagonal Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673292 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:49:56 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-BPjWBfgNQkhHEBehkeSSNMjKqfSrekfv854VOfzLryv Scale = 1:21.0 1 2 3 4 7 6 5 8 9 2x4 3x6 3x4 2x4 2-9-102-9-2 -3-2-12 3-2-12 2-9-10 2-9-10 2-5-73-4-143-6-144.80 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.83 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=0-4-13, 6=Mechanical Max Horz 7=111(LC 25) Max Uplift 7=-166(LC 4), 6=-102(LC 16) Max Grav 7=397(LC 1), 6=49(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-356/160 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 166 lb uplift at joint 7 and 102 lb uplift at joint 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 31 lb down and 166 lb up at 0-7-11 on top chord, and 17 lb down and 31 lb up at 0-7-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-20, 5-7=-20 Concentrated Loads (lb) Vert: 8=55(F) May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG03 Truss Type Diagonal Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673293 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:49:57 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-fbHuP?h?B2p8rLDuIMzhwaGVa2o3NBv2Mlq2w6zLryu Scale = 1:20.9 1 2 3 4 7 6 5 8 9 2x4 3x6 3x4 2x4 2-9-102-9-2 -3-2-12 3-2-12 2-8-8 2-8-8 2-9-10 0-1-2 2-5-43-4-143-6-114.80 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.83 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=0-4-13, 6=Mechanical Max Horz 7=111(LC 7) Max Uplift 7=-184(LC 4), 6=-105(LC 16) Max Grav 7=384(LC 1), 6=58(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-368/148 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 184 lb uplift at joint 7 and 105 lb uplift at joint 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 49 lb down and 124 lb up at 0-7-11 on top chord, and 43 lb down and 86 lb up at 0-7-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-20, 5-7=-20 Concentrated Loads (lb) Vert: 8=39(B) 9=32(B) May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG04 Truss Type Diagonal Hip Girder Qty 3 Ply 1 3500 Elev C Job Reference (optional) I51673294 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:49:58 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-7orHcLidyMx?TUo4s3UwTnojOS7a6e9CbPZcSYzLryt Scale = 1:21.9 1 2 3 4 7 6 5 3x4 4x6 2x4 2x4 2-8-72-8-7 2-9-30-0-12 -2-8-14 2-8-14 2-9-3 2-9-3 2-5-43-6-143-8-145.66 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.63 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=0-4-9, 6=Mechanical Max Horz 7=113(LC 9) Max Uplift 7=-44(LC 10), 6=-67(LC 7) Max Grav 7=373(LC 1), 6=52(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-337/279 NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -2-8-14 to 1-6-0, Exterior(2R) 1-6-0 to 2-9-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 44 lb uplift at joint 7 and 67 lb uplift at joint 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG05 Truss Type Diagonal Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673295 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:49:59 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-b_PfqhiFjf3s5eNGPn?9??L_ysUNr5PLq3J9?_zLrys Scale = 1:14.5 1 2 3 4 7 6 5 8 9 10 11 3x6 2x4 2x4 4-0-104-0-2 -1-6-12 1-6-12 4-0-10 4-0-10 0-8-82-1-152-3-154.80 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.19 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-4-13, 6=Mechanical Max Horz 7=70(LC 5) Max Uplift 7=-51(LC 4), 6=-20(LC 8) Max Grav 7=255(LC 1), 6=122(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 7 and 20 lb uplift at joint 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 32 lb down and 83 lb up at 1-6-7, and 13 lb down and 35 lb up at 2-4-5 on top chord, and 4 lb down and 7 lb up at 1-6-7, and 1 lb down at 2-4-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-20, 5-7=-20 Concentrated Loads (lb) Vert: 8=28(B) May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG06 Truss Type Diagonal Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673296 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:00 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-3Az111jtUzBjioxTzUWOYCu9iGpaaYfV3j2jXQzLryr Scale = 1:14.5 1 2 3 4 7 6 5 8 9 10 11 3x6 2x4 2x4 4-0-104-0-2 -1-6-12 1-6-12 3-11-8 3-11-8 4-0-10 0-1-2 0-8-82-2-22-3-154.80 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.19 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 -0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-4-13, 6=Mechanical Max Horz 7=70(LC 7) Max Uplift 7=-51(LC 4), 6=-20(LC 8) Max Grav 7=256(LC 1), 6=122(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 7 and 20 lb uplift at joint 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 32 lb down and 83 lb up at 1-6-7, and 13 lb down and 35 lb up at 2-4-5 on top chord, and 4 lb down and 7 lb up at 1-6-7, and 1 lb down at 2-4-5 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-20, 5-7=-20 Concentrated Loads (lb) Vert: 8=28(F) May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG07 Truss Type Diagonal Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673297 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:01 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-YMXPFNkVFHJaKyWfXC2d4QQIAg4_J?veHNoG3tzLryq Scale = 1:10.0 1 2 3 4 6 5 7 3x4 3x8 2x4 2x4 3-1-83-1-0 -2-0-7 2-0-7 3-0-14 3-0-14 3-1-8 0-0-10 0-6-121-3-71-4-83.12 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-5], [2:0-3-2,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.34 0.40 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 2-6 2-6 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-4-11, 6=Mechanical Max Horz 2=36(LC 9) Max Uplift 2=-86(LC 6) Max Grav 2=297(LC 1), 6=76(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -2-0-7 to 2-2-8, Exterior(2R) 2-2-8 to 3-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss CG08 Truss Type Diagonal Hip Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673298 8.530 s Dec 17 2021 MiTek Industries, Inc. Mon May 2 09:09:45 2022 Page 1 ID:W86SVVV9qrHwd_SIVRn9HezrXqs-dMWr711qMLpJkug9lK9sl_mLngM4Rt0ftmruGOzKapK Scale = 1:15.3 1 2 3 4 7 6 5 2x4 3x6 2x4 2x4 2-9-32-9-3 -3-3-4 3-3-4 2-8-7 2-8-7 2-9-3 0-0-12 1-2-142-2-132-4-94.95 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.39 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)7=446/0-4-9, 6=-40/Mechanical Max Horz 7=89(LC 9) Max Uplift 7=-103(LC 6), 6=-40(LC 1) Max Grav 7=446(LC 1), 6=47(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-411/383 NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -3-3-4 to 0-11-11, Exterior(2R) 0-11-11 to 2-9-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 7 and 40 lb uplift at joint 6. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss GE01 Truss Type Monopitch Supported Gable Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673299 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:03 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-UleAf2lmnuZIZGg1ec459rWhsTrKnvVxlhHN8lzLryo Scale = 1:22.3 Sheet BackFull Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 18 10 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-3-8 -0-11-40-11-4 11-11-811-11-8 0-3-143-2-03-3-123.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.14 0.09 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.00 (loc) 1 1 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 10-11. REACTIONS.All bearings 11-11-8. (lb) - Max Horz 2=92(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 12, 13, 14, 15, 16, 17, 11 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 12, 13, 14, 15, 11 except 17=326(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-4 to 2-0-12, Exterior(2N) 2-0-12 to 8-8-0, Corner(3E) 8-8-0 to 11-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 12, 13, 14, 15, 16, 17, 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J01 Truss Type Jack-Closed Qty 7 Ply 1 3500 Elev C Job Reference (optional) I51673300 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:03 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-UleAf2lmnuZIZGg1ec459rWg5TrTnuHxlhHN8lzLryo Scale = 1:16.4 1 2 3 4 7 6 5 3x4 3x4 3x6 2x4 3x4 2x4 2-2-02-2-0 4-4-02-2-0 -0-11-4 0-11-4 2-2-0 2-2-0 4-4-0 2-2-0 0-6-82-8-81-5-01-3-81-8-81-0-06.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [2:0-1-1,0-5-0], [3:0-2-0,0-1-11] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.25 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.03 -0.05 0.03 (loc) 7 7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-1-8 Max Horz 2=60(LC 7) Max Uplift 2=-14(LC 10), 5=-19(LC 10) Max Grav 2=235(LC 1), 5=153(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J04 Truss Type Jack-Closed Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673301 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:04 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-yxCYtOmOYCh9BQFECKbKi22t7tCmWMe4zL0wgCzLryn Scale = 1:11.5 1 2 5 3 43x6 1-6-31-6-3 -0-11-4 0-11-4 1-6-3 1-6-3 0-8-81-8-108.00 12 Plate Offsets (X,Y)-- [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-6-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical, 3=Mechanical Max Horz 5=37(LC 10) Max Uplift 5=-4(LC 10), 3=-18(LC 10) Max Grav 5=145(LC 1), 4=24(LC 3), 3=25(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J05 Truss Type Jack-Closed Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673302 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:05 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-Q8mw4kn0IVp?pZqQm16ZFGb2tHY?FpuEC?mUCezLrym Scale = 1:11.5 1 2 5 3 43x6 1-6-31-6-3 -0-11-4 0-11-4 1-6-3 1-6-3 0-8-81-8-101-3-71-8-108.00 12 Plate Offsets (X,Y)-- [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-6-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical, 3=Mechanical Max Horz 5=37(LC 10) Max Uplift 5=-4(LC 10), 3=-18(LC 10) Max Grav 5=145(LC 1), 4=24(LC 3), 3=25(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J06 Truss Type Jack-Closed Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673303 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:06 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-uKKII4oe3pxsQjPcKldonT891hsv_G8NRfV1k4zLryl Scale = 1:21.0 1 2 3 5 4 3x4 3x6 2x4 2x4 2-11-42-11-4 -1-11-4 1-11-4 2-11-4 2-11-4 2-1-43-6-146.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.33 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=Mechanical Max Horz 5=103(LC 7) Max Uplift 5=-27(LC 10), 4=-52(LC 7) Max Grav 5=280(LC 1), 4=72(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J07 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673304 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:06 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-uKKII4oe3pxsQjPcKldonT89ahrQ_G8NRfV1k4zLryl Scale = 1:16.9 1 2 5 3 43x4 3x6 1-3-81-3-8 -1-11-4 1-11-4 1-3-8 1-3-8 2-1-42-9-02-4-52-9-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.36 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.02 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=52(LC 7) Max Uplift 5=-7(LC 10), 3=-66(LC 1), 4=-27(LC 7) Max Grav 5=285(LC 1), 3=6(LC 6), 4=23(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-259/122 NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J08 Truss Type Jack-Closed Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673305 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:07 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-MWugVQoGq73j2t_ptS91KhgLI49ijiOXgJFaHWzLryk Scale = 1:21.2 1 2 3 5 4 6 7 3x6 3x4 3x6 4-5-14-5-1 -0-11-4 0-11-4 4-5-1 4-5-1 0-8-83-7-143-4-60-3-83-7-148.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0], [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.24 0.32 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.05 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=99(LC 5) Max Uplift 5=-83(LC 8), 4=-42(LC 8) Max Grav 5=526(LC 1), 4=241(LC 31) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 272 lb down and 80 lb up at 0-5-13, and 95 lb down and 26 lb up at 2-5-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 6=-272(B) 7=-86(F) May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J09 Truss Type Jack-Closed Qty 11 Ply 1 3500 Elev C Job Reference (optional) I51673306 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:08 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-qjS3jmpubQCag1Z?RAgGsuDXwUXqS9eguz_8pzzLryj Scale = 1:21.2 1 2 3 5 4 3x6 3x4 2x4 4-5-14-5-1 -0-11-4 0-11-4 4-5-1 4-5-1 0-8-83-7-143-4-60-3-83-7-148.00 12 Plate Offsets (X,Y)-- [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=99(LC 7) Max Uplift 5=-7(LC 10), 4=-26(LC 10) Max Grav 5=239(LC 1), 4=170(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J10 Truss Type Jack-Closed Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673307 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:09 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-Jv?Rw6qWMkKRHB7B?tBVP6miPuu7Bctp7dkhLPzLryi Scale = 1:21.0 1 2 4 3 2x4 2x4 2x4 2x4 2-11-42-11-4 2-11-4 2-11-4 2-1-43-6-146.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 3-4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 3=Mechanical Max Horz 4=89(LC 7) Max Uplift 4=-6(LC 6), 3=-46(LC 7) Max Grav 4=124(LC 18), 3=112(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J11 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673308 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:09 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-Jv?Rw6qWMkKRHB7B?tBVP6mgXuuKBctp7dkhLPzLryi Scale = 1:16.9 1 2 3 7 6 4 5 3x4 3x6 2x4 3x4 1-3-81-3-8 -1-11-4 1-11-4 1-3-8 1-3-8 2-1-42-6-82-9-02-4-52-9-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.32 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.01 (loc) 7 7 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)7=Mechanical, 4=Mechanical, 5=Mechanical Max Horz 7=87(LC 7) Max Uplift 7=-30(LC 10), 4=-37(LC 7), 5=-51(LC 7) Max Grav 7=285(LC 1), 4=20(LC 8), 5=45(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-7=-272/119 NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 4, 5. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J12 Truss Type Jack-Closed Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673309 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:10 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-n5Zp7Sr972SIvLiOZbikyJIpSIEVw37zMHTEtrzLryh Scale = 1:22.2 1 2 3 5 4 6 3x4 3x6 2x4 2x4 -1-11-4 1-11-4 2-0-0 2-0-0 2-5-43-9-43-5-120-3-83-9-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.43 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=108(LC 9) Max Uplift 5=-24(LC 6), 4=-99(LC 7) Max Grav 5=271(LC 18), 4=88(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-11-4 to 1-0-12, Interior(1) 1-0-12 to 1-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J13 Truss Type Jack-Closed Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673310 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:11 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-FI7BLosnuLa9XUHa6IDzUXr2XiaafWN6axDoQIzLryg Scale = 1:22.2 1 2 4 3 2x4 2x4 2x4 2x4 2-0-0 2-0-0 2-5-43-9-43-5-120-3-83-9-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.16 0.07 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 3=0-1-8 Max Horz 4=91(LC 9) Max Uplift 4=-48(LC 6), 3=-84(LC 7) Max Grav 4=123(LC 18), 3=119(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J14 Truss Type Jack-Open Qty 4 Ply 1 3500 Elev C Job Reference (optional) I51673311 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:11 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-FI7BLosnuLa9XUHa6IDzUXrsjiWofWN6axDoQIzLryg Scale = 1:28.7 1 2 3 5 4 5x6 5x8 3x4 3x8 MT18HS 4-0-04-0-0 -1-11-4 1-11-4 4-0-0 4-0-0 2-5-44-10-155-1-44-9-120-3-85-1-48.00 12 Plate Offsets (X,Y)-- [2:0-4-3,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.91 0.37 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.02 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 19 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=-172(LC 8) Max Uplift 4=-85(LC 7) Max Grav 5=308(LC 1), 4=187(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-269/40 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J15 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673312 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:12 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-jUhZY7sPffi09esmg?kC1kN5h5t6OzdGpbyLykzLryf Scale = 1:22.2 1 2 5 6 3 4 4x6 4x8 2-0-02-0-0 -1-11-4 1-11-4 2-0-0 2-0-0 2-5-43-9-48.00 12 Plate Offsets (X,Y)-- [2:0-4-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.64 0.24 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 0.01 -0.06 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=70(LC 7) Max Uplift 3=-38(LC 10), 4=-24(LC 7) Max Grav 5=269(LC 1), 3=25(LC 8), 4=43(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-11-4 to 1-0-12, Interior(1) 1-0-12 to 1-11-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J16 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673313 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:13 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-BgFymTt1QzqtmoRyEjFRZywQbVGk7QtP2FivUAzLrye Scale = 1:22.2 1 4 2 3 2x4 3x6 2-0-02-0-0 2-0-0 2-0-0 2-5-43-9-42-1-18.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.06 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4 4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings Mechanical except (jt=length) 4=0-3-8. (lb) - Max Horz 4=-19(LC 14), 1=-41(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 1 Max Grav All reactions 250 lb or less at joint(s) 4, 2, 3, 1 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 1. 5) Non Standard bearing condition. Review required. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J17 Truss Type Jack-Closed Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673314 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:14 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-BgFymTt1QzqtmoRyEjFRZywJeV9H7QtP2FivU9zLrye Scale: 3/4"=1' 1 2 3 4 6 578 3x6 3x4 3x4 3x8 2-5-72-5-7 5-5-73-0-0 -0-11-4 0-11-4 2-5-7 2-5-7 5-5-7 3-0-0 0-8-82-2-132-4-21-11-50-3-82-2-138.00 12 Plate Offsets (X,Y)-- [3:0-2-1,Edge], [5:0-3-8,Edge], [6:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.50 0.50 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.10 0.00 (loc) 5-6 5-6 5 l/defl >999 >626 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-7 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=62(LC 5) Max Uplift 6=-41(LC 8), 5=-49(LC 5) Max Grav 6=367(LC 1), 5=310(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 97 lb down and 45 lb up at 2-5-7, and 102 lb down and 34 lb up at 3-6-3 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 7=-97(F) 8=-102(F)May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J18 Truss Type Jack-Closed Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673315 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:14 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-ftpKzpufBGykOy09oQng69TVnvZ7st7YHvRS0czLryd Scale = 1:21.7 1 2 3 4 6 5 3x6 3x4 3x4 3x6 3-11-73-11-7 5-5-71-6-0 -0-11-4 0-11-4 3-11-7 3-11-7 5-5-7 1-6-0 0-8-83-2-73-4-22-10-150-3-83-2-78.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge], [5:Edge,0-2-0], [6:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.41 0.21 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-7 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=89(LC 7) Max Uplift 6=-13(LC 10), 5=-18(LC 7) Max Grav 6=278(LC 1), 5=200(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J19 Truss Type Jack-Closed Qty 12 Ply 1 3500 Elev C Job Reference (optional) I51673316 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:15 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-73NiB9vHya4b06bLL8IvfN?iDJv9bKMiVZB?Z3zLryc Scale = 1:26.5 1 2 3 5 4 3x6 3x4 3x6 5-5-75-5-7 -0-11-4 0-11-4 5-5-7 5-5-7 0-8-84-4-24-0-100-3-84-4-28.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0], [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.30 0.22 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-7 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=118(LC 7) Max Uplift 5=-6(LC 10), 4=-32(LC 10) Max Grav 5=278(LC 1), 4=214(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J20 Truss Type Jack-Closed Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673317 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:16 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-bFx4OVvvjuCSdGAXvrp8BaYvajGYKncrkDwZ5VzLryb Scale = 1:14.6 1 2 3 4 2x4 2x4 3x4 3x6 3-7-43-7-4 -0-11-4 0-11-4 3-7-4 3-7-4 0-6-82-4-26.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1], [2:0-1-1,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.14 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8 Max Horz 2=61(LC 7) Max Uplift 4=-14(LC 10), 2=-15(LC 10) Max Grav 4=122(LC 1), 2=208(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J21 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673318 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:16 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-bFx4OVvvjuCSdGAXvrp8BaYw?jIZKncrkDwZ5VzLryb Scale = 1:9.7 1 2 5 3 4 3x6 0-11-100-11-10 -0-11-4 0-11-4 0-11-10 0-11-10 0-8-81-4-40-11-11-4-48.00 12 Plate Offsets (X,Y)-- [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 0-11-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=28(LC 10) Max Uplift 5=-9(LC 10), 3=-8(LC 1), 4=-3(LC 1) Max Grav 5=141(LC 1), 3=5(LC 6), 4=12(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J22 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673319 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:17 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-4RUSbrwYUBKJFPlkTZKNko55R6eP3Es?zsg6dxzLrya Scale = 1:11.4 1 2 3 4 3x4 3x6 2-4-02-4-0 -0-11-4 0-11-4 2-4-0 2-4-0 0-6-81-8-81-3-131-8-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1], [2:0-1-1,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=45(LC 10) Max Uplift 3=-27(LC 10), 2=-10(LC 10) Max Grav 3=47(LC 1), 2=167(LC 1), 4=42(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J23 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673320 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:18 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-Ye2rpBxAEVS9tZJw1GrcG?dGUW_1oh68BWPg9OzLryZ Scale = 1:9.7 1 2 5 3 4 3x6 0-11-100-11-10 -0-11-4 0-11-4 0-11-10 0-11-10 0-8-81-4-40-11-11-4-48.00 12 Plate Offsets (X,Y)-- [5:0-3-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 0-11-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=28(LC 10) Max Uplift 5=-9(LC 10), 3=-8(LC 1), 4=-3(LC 1) Max Grav 5=141(LC 1), 3=5(LC 6), 4=12(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J24 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673321 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:18 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-Ye2rpBxAEVS9tZJw1GrcG?dGBW_eoh68BWPg9OzLryZ Scale = 1:11.4 1 2 3 4 3x4 3x6 2-4-02-4-0 -0-11-4 0-11-4 2-4-0 2-4-0 0-6-81-8-81-3-131-8-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1], [2:0-1-1,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=45(LC 10) Max Uplift 3=-27(LC 10), 2=-10(LC 10) Max Grav 3=47(LC 1), 2=167(LC 1), 4=42(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J25 Truss Type Jack-Open Qty 3 Ply 1 3500 Elev C Job Reference (optional) I51673322 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:19 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-0qcD0Xyo?pa0Uju6azMrpDARWwJzX8MIQA9DiqzLryY Scale = 1:9.8 1 2 3 4 3x4 3x6 2-0-02-0-0 -1-3-4 1-3-4 2-0-0 2-0-0 0-6-101-4-101-0-41-4-105.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-3], [2:0-1-6,0-5-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=38(LC 10) Max Uplift 3=-19(LC 10), 2=-23(LC 6) Max Grav 3=33(LC 1), 2=182(LC 1), 4=39(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J26 Truss Type Jack-Closed Qty 9 Ply 1 3500 Elev C Job Reference (optional) I51673323 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:20 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-U0AbEszQm6it6tTJ8ht4MQjYrKeSGbcRfqumEGzLryX Scale = 1:15.1 1 2 5 6 3 42x4 3x6 2-0-02-0-0 -2-3-12 2-3-12 2-0-0 2-0-0 1-2-142-4-141-11-152-4-147.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.37 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=56(LC 10) Max Uplift 5=-27(LC 10), 3=-20(LC 1), 4=-5(LC 1) Max Grav 5=320(LC 1), 3=10(LC 6), 4=27(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-278/167 NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -2-3-12 to 0-8-4, Interior(1) 0-8-4 to 1-11-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J27 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673324 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:22 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-QPILfY_gIkybLBdhG6wYRroxg7KTkV5k68NtJ9zLryV Scale = 1:9.9 1 2 3 4 4x6 1-8-121-8-12 -0-11-4 0-11-4 1-8-12 1-8-12 0-6-81-4-146.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.11 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 2-4 2-4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=Mechanical Max Horz 2=36(LC 7) Max Uplift 2=-12(LC 7), 4=-8(LC 7) Max Grav 2=142(LC 1), 4=52(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss J28 Truss Type Jack-Open Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673325 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:27 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-nN5EiG2p7GbuSyWf2fVj8vVp782?PlLTGQ5e_MzLryQ Scale = 1:9.9 1 2 3 4 3x4 3x6 1-8-121-8-12 -0-11-4 0-11-4 1-8-12 1-8-12 0-6-81-4-141-0-31-4-146.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1], [2:0-1-1,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 2 2 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-8-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=37(LC 10) Max Uplift 3=-20(LC 10), 2=-10(LC 10) Max Grav 3=34(LC 1), 2=142(LC 1), 4=34(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss M01 Truss Type Monopitch Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673326 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:28 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-FZfcvc3Ruajl364rcM1yg62lYYEJ8CacV4qBWpzLryP Scale = 1:18.7 1 2 3 4 5 6 2x4 2x4 2x4 7-11-87-11-8 -1-3-4 1-3-4 7-11-8 7-11-8 0-5-53-1-22-9-100-3-83-1-24.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.97 0.66 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.41 -0.00 (loc) 2-4 2-4 4 l/defl >444 >222 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=90(LC 7) Max Uplift 2=-52(LC 6), 4=-24(LC 10) Max Grav 2=400(LC 1), 4=299(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 4-9-12, Exterior(2E) 4-9-12 to 7-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss M02 Truss Type Monopitch Qty 4 Ply 1 3500 Elev C Job Reference (optional) I51673327 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:29 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-jlD?7x43ftrchFf1A4YBDKb20yfVtfqmjkal2FzLryO Scale = 1:15.4 1 2 3 4 5 6 2x4 2x4 2x4 5-11-85-11-8 -1-3-4 1-3-4 5-11-8 5-11-8 0-5-52-5-22-1-100-3-82-5-24.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.47 0.34 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.12 0.00 (loc) 2-4 2-4 4 l/defl >999 >550 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=69(LC 7) Max Uplift 2=-50(LC 6), 4=-17(LC 10) Max Grav 2=322(LC 1), 4=216(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 2-9-12, Exterior(2E) 2-9-12 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss M03 Truss Type Monopitch Qty 5 Ply 1 3500 Elev C Job Reference (optional) I51673328 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:30 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-BynNKH4iQBzSJPEEkn3QmX7IoM2?c64vyOJIbhzLryN Scale = 1:11.6 1 2 3 4 2x4 2x4 2x4 3-11-83-11-8 -1-3-4 1-3-4 3-11-8 3-11-8 0-5-51-9-21-5-100-3-81-9-24.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=49(LC 9) Max Uplift 2=-50(LC 6), 4=-9(LC 10) Max Grav 2=248(LC 1), 4=130(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss M04 Truss Type Monopitch Qty 9 Ply 1 3500 Elev C Job Reference (optional) I51673329 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:30 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-BynNKH4iQBzSJPEEkn3QmX7FIMzzcySvyOJIbhzLryN Scale = 1:22.1 1 2 3 4 7 6 5 8 9 10 4x6 3x4 3x4 2x4 3x8 3x6 6-4-86-4-8 11-11-85-7-0 -0-11-4 0-11-4 6-4-8 6-4-8 11-11-8 5-7-0 0-3-143-2-03-3-120-9-43-3-123.00 12 Plate Offsets (X,Y)-- [2:0-3-4,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.38 0.46 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.13 0.01 (loc) 2-7 2-7 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 40 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 9=0-1-8 Max Horz 2=82(LC 6) Max Uplift 2=-47(LC 6), 9=-32(LC 10) Max Grav 2=538(LC 1), 9=444(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1064/113, 6-8=-22/338, 4-8=-22/338 BOT CHORD 2-7=-159/988, 6-7=-159/988 WEBS 3-7=0/253, 3-6=-943/169, 4-9=-451/74 NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 11-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 9. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673330 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:32 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-8Ku7lz6yxoDAYjOcrC5uryCb29iw4rFCPioPfazLryL Scale = 1:16.7 1 2 3 7 6 5 4 8 9 10 3x4 2x4 3x4 2x4 3x4 6x16 3-1-83-1-8 4-3-81-2-0 3-1-8 3-1-8 4-3-8 1-2-0 1-5-52-8-22-9-50-11-141-0-04.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.36 0.23 0.73 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.01 (loc) 6 6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 4=0-3-8 Max Horz 7=57(LC 5) Max Uplift 7=-41(LC 4) Max Grav 7=1255(LC 1), 4=1196(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-342/0, 1-7=-274/0 BOT CHORD 6-7=0/269, 4-5=0/525 WEBS 5-6=0/471, 2-5=0/700, 2-4=-602/0 NOTES-(8-9) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-2-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 647 lb down and 174 lb up at 0-1-12, and 756 lb down at 3-7-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 6-7=-20, 4-5=-20 Concentrated Loads (lb) Vert: 7=-647 9=-749 10=-756(F)May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T01 Truss Type Common Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673331 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:33 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-cWSVyJ7ai6L1AtzoPwc7NAlheZxapQiLeMYyB0zLryK Scale = 1:44.1 1 2 3 4 5 6 7 9 8 10 11 12 13 8x14 MT18HS 4x8 3x4 3x4 3x6 2x4 4x8 3x4 3x4 9-0-09-0-0 18-0-09-0-0 -0-11-4 0-11-4 9-0-0 9-0-0 18-0-0 9-0-0 18-11-4 0-11-4 0-8-86-8-80-8-88.00 12 Plate Offsets (X,Y)-- [2:0-4-5,Edge], [6:0-4-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.69 0.65 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.25 0.02 (loc) 6-9 6-9 6 l/defl >999 >863 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 65 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 5-4-9, Right 2x4 SPF-S Stud 5-4-9 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=122(LC 9) Max Uplift 2=-13(LC 10), 6=-13(LC 11) Max Grav 2=776(LC 1), 6=776(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-861/51, 4-6=-861/51 BOT CHORD 2-9=0/577, 6-9=0/577 WEBS 4-9=0/399 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 15-11-4, Exterior(2E) 15-11-4 to 18-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T02 Truss Type ROOF SPECIAL Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673332 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:34 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-4j0uAf7CTQTun1Y?zd8MwNIvXzIEYkGVt0HWkSzLryJ Scale = 1:44.3 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 7x16 MT18HS 4x8 3x6 3x6 3x6 4x8 4x10 5x12 4x8 3x6 4x8 5x12 2-2-02-2-0 9-0-06-10-0 15-10-06-10-0 18-0-02-2-0 -0-11-4 0-11-4 2-2-0 2-2-0 9-0-0 6-10-0 15-10-0 6-10-0 18-0-0 2-2-0 18-11-4 0-11-4 0-8-86-8-80-8-81-0-08.00 12 Plate Offsets (X,Y)-- [10:Edge,0-3-8], [12:0-2-8,0-0-0], [14:0-2-8,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.49 0.63 0.82 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.21 0.18 (loc) 12-13 12-13 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 74 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-13, 4-13 REACTIONS. (size)16=0-3-8, 10=0-3-8 Max Horz 16=-135(LC 8) Max Uplift 16=-14(LC 10), 10=-14(LC 11) Max Grav 16=773(LC 1), 10=773(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-676/0, 3-4=-1808/161, 4-5=-876/33, 5-6=-876/37, 6-7=-1808/71, 7-8=-676/0, 2-16=-728/43, 8-10=-728/43 BOT CHORD 15-16=-22/415, 13-14=-230/1793, 12-13=-76/1727, 10-11=0/371 WEBS 14-15=-9/282, 4-14=0/335, 6-12=0/333, 5-13=0/496, 6-13=-1094/223, 4-13=-1175/292, 3-14=-207/1558, 3-15=-426/17, 7-12=-74/1500, 7-11=-371/0 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-4, Interior(1) 2-0-4 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 15-11-4, Exterior(2E) 15-11-4 to 18-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) The Fabrication Tolerance at joint 2 = 16%, joint 8 = 16% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T03 Truss Type HIP Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673333 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:35 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-YvaGN?8qEjblPA7BWLfbSbq3TNf6HDYe6g13GvzLryI Scale = 1:33.5 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 5x6 5x6 4x8 2x4 5x8 5x8 2x4 3x6 4x8 4x10 3x6 4x10 2x4 3x8 2-2-02-2-0 9-0-06-10-0 15-10-06-10-0 18-0-02-2-0 -0-11-4 0-11-4 4-6-0 4-6-0 9-0-0 4-6-0 13-6-0 4-6-0 15-10-0 2-4-0 18-0-0 2-2-0 18-11-4 0-11-4 0-8-83-6-133-8-80-8-81-0-03-6-138.00 12 Plate Offsets (X,Y)-- [5:0-3-0,0-2-3], [7:0-3-0,0-2-3], [12:Edge,0-3-8], [14:0-2-8,0-2-12], [16:0-2-8,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.54 0.52 0.69 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.21 0.12 (loc) 14-15 14-15 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-8-12 max.): 5-7. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size)18=0-3-8, 12=0-3-8 Max Horz 18=-78(LC 8) Max Grav 18=773(LC 1), 12=773(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-714/28, 3-4=-1625/21, 4-5=-1733/49, 5-6=-1450/41, 6-7=-1450/41, 7-8=-1733/38, 8-9=-1625/4, 9-10=-714/28, 2-18=-723/60, 10-12=-723/60 BOT CHORD 17-18=-37/420, 15-16=-50/991, 14-15=0/991, 12-13=0/420 WEBS 16-17=-23/291, 13-14=0/291, 5-16=-24/642, 7-14=0/642, 3-16=-50/1262, 3-17=-453/46, 9-14=0/1262, 9-13=-453/0, 6-15=-304/88, 5-15=-17/564, 7-15=-17/564 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 1-11-4, Exterior(2R) 1-11-4 to 16-0-12, Exterior(2E) 16-0-12 to 18-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 2 = 8%, joint 10 = 8% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T04 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673334 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:36 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-058ebL9S?1jc1KiN42Aq?oNE9n?D0fOoKKmcoLzLryH Scale = 1:34.5 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 5x10 MT18HS 5x10 MT18HS 4x8 2x4 5x8 5x8 2x4 3x6 4x8 3x6 4x10 3x6 4x10 2-2-02-2-0 9-0-06-10-0 15-10-06-10-0 18-0-02-2-0 -0-11-4 0-11-4 6-0-0 6-0-0 12-0-0 6-0-0 15-10-0 3-10-0 18-0-0 2-2-0 18-11-4 0-11-4 0-8-84-6-134-8-80-8-81-0-04-6-138.00 12 Plate Offsets (X,Y)-- [5:0-7-4,0-2-4], [6:0-7-4,0-2-4], [11:Edge,0-3-8], [13:0-2-0,0-2-12], [15:0-2-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.54 0.53 0.72 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.20 0.13 (loc) 14-15 13-14 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 72 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins, except end verticals, and 2-0-0 oc purlins (5-2-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)17=0-3-8, 11=0-3-8 Max Horz 17=-96(LC 8) Max Grav 17=773(LC 1), 11=773(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-702/25, 3-4=-1661/18, 4-5=-1823/100, 5-6=-933/29, 6-7=-1823/88, 7-8=-1661/18, 8-9=-702/25, 2-17=-727/59, 9-11=-727/59 BOT CHORD 16-17=-35/402, 14-15=-10/853, 13-14=0/853, 11-12=0/402 WEBS 15-16=-23/281, 12-13=0/279, 5-15=-116/879, 6-13=-64/851, 3-15=-30/1309, 3-16=-428/45, 8-13=0/1309, 8-12=-428/0 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-4, Exterior(2R) 2-0-4 to 15-11-12, Exterior(2E) 15-11-12 to 18-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 2 = 8%, joint 9 = 8% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T05 Truss Type Roof Special Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673335 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:37 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-UIi0ohA5mLrTeUGaelh3Y0wNRAKZl4lxZ_WAKnzLryG Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 3x8 3x4 3x6 3x8 MT18HS 3x6 3x6 3x6 3x6 3x6 2x4 5x6 5x12 3x6 5x6 3x8 MT18HS 10-2-910-2-9 20-2-1110-0-1 30-2-1210-0-1 36-0-05-9-4 7-8-9 7-8-9 15-2-10 7-6-1 22-8-11 7-6-1 30-2-12 7-6-1 36-0-0 5-9-4 37-11-4 1-11-4 4-10-14-11-142-1-44-10-16.00 12 Plate Offsets (X,Y)-- [8:0-2-11,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.70 0.59 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.50 0.09 (loc) 15-16 15-16 10 l/defl >999 >852 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 143 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 2-16,6-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-11 oc purlins, except end verticals, and 2-0-0 oc purlins (2-9-15 max.): 1-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-16, 6-11 REACTIONS. (size)16=Mechanical, 10=0-3-8 Max Horz 16=-142(LC 8) Max Uplift 16=-88(LC 6), 10=-21(LC 6) Max Grav 16=1425(LC 1), 10=1557(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2286/112, 4-6=-2761/126, 6-7=-1473/75, 7-8=-1728/69, 8-10=-1521/113 BOT CHORD 15-16=-131/1931, 13-15=-162/2760, 11-13=-136/2650 WEBS 2-16=-2211/167, 2-15=0/761, 4-15=-641/116, 6-13=0/361, 6-11=-1408/144, 7-11=0/453, 8-11=-15/1531 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 27-2-12, Exterior(2R) 27-2-12 to 33-2-12, Interior(1) 33-2-12 to 34-11-4, Exterior(2E) 34-11-4 to 37-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T06 Truss Type Half Hip Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673336 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:38 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-yUGO00AjXezKGermCTCI4DSbKamVUk35oeFjtDzLryF Scale = 1:25.9 1 2 3 4 6 5 7 3x4 3x4 3x4 3x6 2x4 3-2-73-2-7 4-5-11-2-10 -1-11-4 1-11-4 3-2-7 3-2-7 4-5-1 1-2-10 2-5-44-5-34-6-144-1-110-3-84-5-38.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.50 0.16 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-1 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=130(LC 7) Max Uplift 6=-20(LC 10), 5=-59(LC 7) Max Grav 6=322(LC 1), 5=145(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-279/154 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-11-4 to 1-0-12, Exterior(2R) 1-0-12 to 3-2-7, Exterior(2E) 3-2-7 to 4-3-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T07 Truss Type Roof Special Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673337 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:39 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-QgpnDMBLIy5BuoQylAjXdR?fy_xjDz3E0I?HPgzLryE Scale: 3/16"=1' 1 2 3 4 5 6 7 14 13 12 11 10 9 8 15 16 17 18 3x6 3x4 3x6 4x6 4x6 5x8 3x6 3x6 5x8 4x6 6x8 5x8 3x8 MT18HS 9-3-159-3-15 18-5-59-1-7 27-6-129-1-7 36-0-08-5-4 7-0-9 7-0-9 13-10-10 6-10-1 20-8-11 6-10-1 27-6-12 6-10-1 36-0-0 8-5-4 37-11-4 1-11-4 6-2-16-3-142-1-46-2-16.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-3-0], [5:0-4-6,Edge], [6:0-3-8,Edge], [8:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.86 0.91 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.20 -0.42 0.09 (loc) 13-14 13-14 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 154 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-14,4-9,6-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-2 oc purlins, except end verticals, and 2-0-0 oc purlins (3-7-2 max.): 1-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-14, 4-9 REACTIONS. (size)14=Mechanical, 8=0-3-8 Max Horz 14=-181(LC 6) Max Uplift 14=-88(LC 6) Max Grav 14=1425(LC 1), 8=1557(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1668/86, 3-4=-2164/88, 4-5=-1550/95, 5-6=-1853/66, 6-8=-1484/130 BOT CHORD 13-14=-82/1390, 11-13=-97/2069, 9-11=-73/2142 WEBS 2-14=-1800/135, 2-13=0/767, 3-13=-655/100, 4-9=-850/117, 5-9=0/461, 6-9=-0/1451 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 24-6-12, Exterior(2R) 24-6-12 to 30-6-12, Interior(1) 30-6-12 to 34-11-4, Exterior(2E) 34-11-4 to 37-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T08 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673338 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:40 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-vtN9QiCz3GE2Vy?9JuEm9eYr7OLYyRXNFykqx6zLryD Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 20 21 3x6 5x6 5x6 3x8 MT18HS 3x6 2x4 3x8 3x4 3x8 4x10 3x12 3x4 3x4 3x4 5x8 3x6 7-2-57-2-5 14-2-127-0-7 24-10-1210-8-0 36-0-011-1-4 7-2-5 7-2-5 14-2-12 7-0-7 19-6-12 5-4-0 24-10-12 5-4-0 30-3-10 5-4-14 36-0-0 5-8-6 0-6-87-6-17-7-142-1-47-6-16.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.80 0.63 0.83 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.25 -0.51 0.08 (loc) 10-11 10-11 10 l/defl >999 >840 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 149 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud *Except* 6-13,6-11: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 3-10-8 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-5 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 6-11, 8-10 REACTIONS. (size)1=Mechanical, 10=0-3-8 Max Horz 1=104(LC 7) Max Grav 1=1432(LC 1), 10=1432(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2565/73, 3-5=-2023/104, 5-6=-1718/119, 6-7=-1531/109, 7-8=-1791/98 BOT CHORD 1-15=-20/2202, 13-15=-20/2202, 11-13=0/1767, 10-11=-4/1447 WEBS 3-13=-554/130, 5-13=0/539, 6-11=-482/95, 7-11=0/494, 8-11=0/258, 8-10=-1774/55 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-12 to 3-0-12, Interior(1) 3-0-12 to 9-11-13, Exterior(2R) 9-11-13 to 18-5-11, Interior(1) 18-5-11 to 20-7-13, Exterior(2R) 20-7-13 to 29-1-11, Interior(1) 29-1-11 to 32-10-4, Exterior(2E) 32-10-4 to 35-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T09 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673339 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:41 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-N3xXe2DbqZMv75aLtbm?is40KndrhvpXUbUNUYzLryC Scale = 1:63.0 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 19 3x8 5x12 5x12 3x6 3x8 MT18HS 3x4 3x6 2x4 3x4 2x4 4x8 3x4 3x4 5x6 5x12 3x6 9-10-59-10-5 19-6-129-8-7 29-3-39-8-7 35-9-06-5-13 8-6-5 8-6-5 16-10-12 8-4-7 22-2-12 5-4-0 29-3-3 7-0-7 35-9-0 6-5-13 0-6-88-10-18-11-142-2-128-10-16.00 12 Plate Offsets (X,Y)-- [1:0-1-5,0-2-0], [5:0-6-0,0-0-15], [6:0-6-0,0-0-15], [9:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.77 0.88 0.83 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.43 0.08 (loc) 11-13 11-13 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 152 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-15,8-11,9-10,9-11: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 4-7-8 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-6 oc purlins, except end verticals, and 2-0-0 oc purlins (4-7-7 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-13, 6-11 REACTIONS. (size)10=Mechanical, 1=Mechanical Max Horz 1=118(LC 9) Max Uplift 1=-10(LC 10) Max Grav 10=1422(LC 1), 1=1422(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2482/71, 3-5=-2345/138, 5-6=-1462/121, 6-8=-1779/162, 8-9=-1749/63, 9-10=-1373/47 BOT CHORD 1-15=-59/2127, 13-15=0/1478, 11-13=0/1384 WEBS 3-15=-457/200, 5-15=-101/827, 6-13=0/379, 6-11=-127/266, 8-11=-440/186, 9-11=0/1521 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-12 to 3-0-12, Interior(1) 3-0-12 to 12-7-13, Exterior(2R) 12-7-13 to 26-5-11, Interior(1) 26-5-11 to 32-7-4, Exterior(2E) 32-7-4 to 35-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T10 Truss Type Common Qty 3 Ply 1 3500 Elev C Job Reference (optional) I51673340 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:42 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-rFVvrOEDbtUmlF9XRJHEF3dAXByuQMMgjFDx0?zLryB Scale = 1:65.2 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 16 17 18 4x8 3x4 3x4 3x6 3x6 3x6 4x6 3x6 2x4 3x6 5x6 3x8 3x6 4x10 6x6 3x6 8-11-128-11-12 19-6-1210-7-0 27-6-27-11-6 35-9-08-2-14 6-7-7 6-7-7 13-1-2 6-5-10 19-6-12 6-5-10 27-6-2 7-11-6 35-9-0 8-2-14 0-6-810-3-142-2-126.00 12 Plate Offsets (X,Y)-- [9:Edge,0-1-12], [10:Edge,0-3-8], [11:0-3-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.87 0.90 0.81 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.28 -0.62 0.08 (loc) 13-15 13-15 10 l/defl >999 >690 n/a L/d 240 180 n/a PLATES MT20 Weight: 149 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-13,6-13,8-13: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 3-6-12 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-13, 8-13 REACTIONS. (size)1=0-3-8, 10=Mechanical Max Horz 1=131(LC 9) Max Uplift 1=-21(LC 10), 10=-2(LC 11) Max Grav 1=1418(LC 1), 10=1418(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2516/58, 3-5=-2314/75, 5-6=-1518/129, 6-8=-1546/126, 8-9=-1826/73, 9-10=-1340/61 BOT CHORD 1-15=-111/2154, 13-15=-36/1740, 11-13=0/1549 WEBS 3-15=-283/138, 5-15=0/543, 5-13=-694/153, 6-13=0/891, 8-13=-423/136, 9-11=0/1486 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 16-6-12, Exterior(2R) 16-6-12 to 22-6-12, Interior(1) 22-6-12 to 32-7-4, Exterior(2E) 32-7-4 to 35-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T11 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673341 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:43 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-JS3H3kErMBccNPkj_0oTnHAKwbIH9omqxvzUYRzLryA Scale = 1:70.3 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 18 19 20 21 3x6 3x8 MT18HS 3x8 MT18HS 3x6 3x6 4x6 3x6 2x4 3x6 5x6 6x8 3x12 3x6 3x8 3x6 3x6 8-11-128-11-12 19-6-1210-7-0 27-6-27-11-6 27-11-130-5-11 35-9-07-9-3 -0-11-4 0-11-4 6-7-7 6-7-7 13-1-2 6-5-10 18-7-7 5-6-5 19-6-12 0-11-5 20-6-1 0-11-5 27-6-2 7-0-1 27-11-13 0-5-11 35-9-0 7-9-3 0-6-89-8-69-10-32-2-129-8-66.00 12 Plate Offsets (X,Y)-- [6:0-4-6,Edge], [8:0-4-6,Edge], [11:0-3-8,Edge], [12:Edge,0-3-8], [13:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.96 0.95 0.80 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.28 -0.61 0.08 (loc) 15-17 15-17 12 l/defl >999 >702 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 146 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 7-15,5-15,10-15: 2x4 SPF No.2 WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 5-15, 10-15 REACTIONS. (size)12=Mechanical, 2=0-3-8 Max Horz 2=129(LC 7) Max Uplift 2=-31(LC 10) Max Grav 12=1417(LC 1), 2=1484(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2557/48, 3-5=-2336/65, 5-6=-1521/114, 6-7=-1270/123, 7-8=-1271/123, 8-10=-1555/112, 10-11=-1817/64, 11-12=-1339/56 BOT CHORD 2-17=-98/2174, 15-17=-21/1728, 13-15=0/1538 WEBS 3-17=-295/141, 5-17=0/574, 11-13=0/1469, 7-15=0/821, 5-15=-653/145, 10-15=-381/131 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 14-4-8, Exterior(2R) 14-4-8 to 24-9-0, Interior(1) 24-9-0 to 32-7-4, Exterior(2E) 32-7-4 to 35-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T12 Truss Type COMMON Qty 5 Ply 1 3500 Elev C Job Reference (optional) I51673342 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:44 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-nedgG4FU7UkT_ZJwYkJiKUiY??hfuL6zAZi24tzLry9 Scale = 1:61.3 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16 3x6 5x8 3x6 5x8 3x4 3x4 5x12 2x4 5x12 5x12 3x6 3x6 2x4 12-0-1012-0-10 23-11-611-10-13 35-9-011-9-10 -0-11-4 0-11-4 9-0-15 9-0-15 18-0-0 8-11-1 26-11-1 8-11-1 35-9-0 8-9-15 0-6-89-6-80-8-06.00 12 Plate Offsets (X,Y)-- [2:0-1-9,0-2-4], [10:0-0-0,0-3-1], [11:0-6-0,0-3-0], [12:0-6-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.74 0.68 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.57 0.08 (loc) 2-12 2-12 10 l/defl >999 >751 n/a L/d 240 180 n/a PLATES MT20 Weight: 132 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 8-11,4-12: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 4-11-4, Right 2x4 SPF-S Stud 4-10-13 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=Mechanical, 2=0-3-8 Max Horz 2=120(LC 14) Max Uplift 10=-13(LC 11), 2=-28(LC 10) Max Grav 10=1423(LC 1), 2=1490(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2425/77, 4-6=-2150/111, 6-8=-2140/114, 8-10=-2412/81 BOT CHORD 2-12=-75/2072, 11-12=0/1384, 10-11=0/2057 WEBS 6-11=-40/794, 8-11=-503/208, 6-12=-39/807, 4-12=-513/208 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 15-0-0, Exterior(2R) 15-0-0 to 21-0-0, Interior(1) 21-0-0 to 32-9-0, Exterior(2E) 32-9-0 to 35-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 2. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T13 Truss Type COMMON Qty 3 Ply 1 3500 Elev C Job Reference (optional) I51673343 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:45 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-FqB2UQG6uosKcju66RqxsiFj0P1vdoL7PDSbdJzLry8 Scale = 1:62.0 1 2 3 4 5 6 7 8 9 1011 13 12 14 15 16 17 3x6 5x8 3x6 5x12 3x6 3x6 5x12 2x4 5x12 2x4 5x12 3x6 3x6 12-0-1012-0-10 23-11-611-10-13 36-0-012-0-10 -0-11-4 0-11-4 9-0-15 9-0-15 18-0-0 8-11-1 26-11-1 8-11-1 36-0-0 9-0-15 36-11-4 0-11-4 0-6-89-6-80-6-86.00 12 Plate Offsets (X,Y)-- [2:0-1-9,0-2-4], [10:0-1-9,0-2-4], [12:0-6-0,0-3-4], [13:0-6-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.73 0.68 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.57 0.08 (loc) 2-13 2-13 10 l/defl >999 >751 n/a L/d 240 180 n/a PLATES MT20 Weight: 134 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 8-12,4-13: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 4-11-4, Right 2x4 SPF-S Stud 4-11-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-117(LC 11) Max Uplift 2=-28(LC 10), 10=-28(LC 11) Max Grav 2=1493(LC 1), 10=1493(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2432/75, 4-6=-2156/108, 6-8=-2156/108, 8-10=-2431/75 BOT CHORD 2-13=-72/2078, 12-13=0/1390, 10-12=0/2078 WEBS 6-12=-39/807, 8-12=-513/208, 6-13=-39/807, 4-13=-513/208 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 15-0-0, Exterior(2R) 15-0-0 to 21-0-0, Interior(1) 21-0-0 to 33-11-4, Exterior(2E) 33-11-4 to 36-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T14 Truss Type HIP Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673344 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:46 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-j1lQhlHke6_BEtSIg8LAPvorloJkMGmGdtB89mzLry7 Scale = 1:63.0 1 2 3 4 5 6 7 8 9 1011 16 15 14 13 12 17 18 19 20 21 22 5x6 5x6 5x12 3x12 3x8 MT18HS3x8 2x4 2x4 3x8 3x8 2x4 5x12 3x12 3x8 MT18HS 10-3-410-3-4 18-0-07-8-12 25-8-127-8-12 36-0-010-3-4 -0-11-4 0-11-4 5-2-9 5-2-9 10-3-4 5-0-11 18-0-0 7-8-12 25-8-12 7-8-12 30-9-7 5-0-11 36-0-0 5-2-9 36-11-4 0-11-4 0-6-85-6-55-8-20-6-85-6-56.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.92 0.90 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.43 0.13 (loc) 2-16 2-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 139 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-16,6-12: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 2-9-1, Right 2x4 SPF-S Stud 2-9-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-2 oc purlins, except 2-0-0 oc purlins (2-2-0 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16, 6-12 REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-69(LC 11) Max Grav 2=1493(LC 1), 10=1493(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2533/88, 4-5=-2288/69, 5-6=-1987/86, 6-7=-1987/86, 7-8=-2288/69, 8-10=-2533/88 BOT CHORD 2-16=-9/2159, 14-16=0/2514, 12-14=0/2514, 10-12=-9/2159 WEBS 5-16=0/632, 6-16=-740/90, 6-14=0/284, 6-12=-740/90, 7-12=0/632 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 6-0-5, Exterior(2R) 6-0-5 to 14-6-3, Interior(1) 14-6-3 to 21-5-13, Exterior(2R) 21-5-13 to 29-11-11, Interior(1) 29-11-11 to 33-11-4, Exterior(2E) 33-11-4 to 36-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T15 Truss Type HIP Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673345 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:48 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-gPsA6RI_AjEvTAchnZOeUKtCZc1Aq9LZ5BgFDezLry5 Scale = 1:63.1 1 2 3 4 5 6 7 8 9 1011 16 15 14 13 12 17 18 19 20 21 22 5x12 5x12 4x10 3x6 3x6 3x6 3x6 2x4 2x4 3x8 3x6 2x4 4x10 3x6 3x6 3x6 9-0-159-0-15 18-0-08-11-1 26-11-18-11-1 36-0-09-0-15 -0-11-4 0-11-4 6-6-9 6-6-9 12-11-4 6-4-11 18-0-0 5-0-12 23-0-12 5-0-12 29-5-7 6-4-11 36-0-0 6-6-9 36-11-4 0-11-4 0-6-86-10-57-0-20-6-86-10-56.00 12 Plate Offsets (X,Y)-- [2:0-1-1,0-1-12], [5:0-6-0,0-0-15], [7:0-6-0,0-0-15], [10:0-1-1,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.78 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.35 0.11 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 139 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 3-6-4, Right 2x4 SPF-S Stud 3-6-4 BRACING- TOP CHORD Structural wood sheathing directly applied, except 2-0-0 oc purlins (3-11-13 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-85(LC 11) Max Grav 2=1493(LC 1), 10=1493(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2526/81, 4-5=-2313/96, 5-6=-1977/114, 6-7=-1977/114, 7-8=-2313/96, 8-10=-2526/81 BOT CHORD 2-16=-7/2165, 14-16=0/1768, 12-14=0/1768, 10-12=0/2165 WEBS 4-16=-288/152, 5-16=-16/478, 6-14=-370/97, 5-14=-29/467, 7-14=-29/467, 7-12=-16/478, 8-12=-288/152 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 8-8-5, Exterior(2R) 8-8-5 to 17-2-3, Interior(1) 17-2-3 to 18-9-13, Exterior(2R) 18-9-13 to 27-3-11, Interior(1) 27-3-11 to 33-11-4, Exterior(2E) 33-11-4 to 36-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T16 Truss Type HIP Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673346 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:49 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-8bQZJnJcx1Mm5KBtLHvt1XQSD0NKZfhiKrQpm5zLry4 Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 1112 17 16 15 14 13 18 19 20 21 3x8 5x12 5x12 3x8 3x6 4x10 3x6 3x6 3x6 2x4 3x6 3x6 2x4 4x10 3x6 3x6 3x6 9-0-159-0-15 18-0-08-11-1 26-11-18-11-1 36-0-09-0-15 -0-11-4 0-11-4 7-10-9 7-10-9 15-7-4 7-8-11 18-0-0 2-4-12 20-4-12 2-4-12 28-1-7 7-8-11 36-0-0 7-10-9 36-11-4 0-11-4 0-6-88-2-58-4-20-6-88-2-56.00 12 Plate Offsets (X,Y)-- [2:0-1-5,0-1-12], [6:0-6-0,0-0-15], [7:0-6-0,0-0-15], [11:0-1-5,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.52 0.78 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.31 0.11 (loc) 13-15 13-15 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 144 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 6-7: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-17,7-13: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 4-3-3, Right 2x4 SPF-S Stud 4-3-3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-10 oc purlins, except 2-0-0 oc purlins (4-6-1 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15, 7-15 REACTIONS. (size)11=0-3-8, 2=0-3-8 Max Horz 2=-102(LC 15) Max Uplift 11=-16(LC 11), 2=-16(LC 10) Max Grav 11=1493(LC 1), 2=1493(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2497/100, 4-6=-2369/163, 6-7=-1606/153, 7-9=-2369/163, 9-11=-2497/100 BOT CHORD 2-17=-33/2135, 15-17=0/1579, 13-15=0/1579, 11-13=-5/2135 WEBS 4-17=-394/186, 6-17=-94/723, 7-13=-94/723, 9-13=-394/186 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-12, Interior(1) 2-0-12 to 12-7-4, Exterior(2R) 12-7-4 to 23-4-12, Interior(1) 23-4-12 to 33-11-4, Exterior(2E) 33-11-4 to 36-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 2. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T17 Truss Type Half Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673347 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:50 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-co_xX7KEiKUdiUm4v_Q6ZlyYgQpxH91sYV9MIXzLry3 Scale = 1:18.2 1 2 3 4 5 6 3x6 5x8 3x6 3x8 MT18HS 5-4-05-4-0 7-11-82-7-8 -1-3-4 1-3-4 5-4-0 5-4-0 7-11-8 2-7-8 0-5-52-1-02-2-101-9-80-3-82-1-04.00 12 Plate Offsets (X,Y)-- [3:0-3-0,Edge], [4:0-3-8,Edge], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.86 0.44 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.23 0.00 (loc) 2-5 2-5 5 l/defl >877 >405 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 21 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-1-8 Max Horz 2=60(LC 7) Max Uplift 2=-56(LC 6), 5=-17(LC 6) Max Grav 2=400(LC 1), 5=299(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-270/104 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-4 to 1-8-12, Exterior(2R) 1-8-12 to 5-4-0, Exterior(2E) 5-4-0 to 7-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T18 Truss Type Monopitch Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673348 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:50 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-co_xX7KEiKUdiUm4v_Q6ZlyW_QlSH91sYV9MIXzLry3 Scale = 1:18.7 1 2 3 4 5 6 2x4 2x4 2x4 7-11-87-11-8 -1-3-4 1-3-4 7-11-8 7-11-8 0-5-53-1-22-9-100-3-83-1-24.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.97 0.66 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.41 -0.00 (loc) 2-4 2-4 4 l/defl >444 >222 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=90(LC 7) Max Uplift 2=-52(LC 6), 4=-24(LC 10) Max Grav 2=400(LC 1), 4=299(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-3-4 to 1-8-12, Interior(1) 1-8-12 to 4-9-12, Exterior(2E) 4-9-12 to 7-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T22 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673349 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:51 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-4_YJkTLtTecUKeLGSixL6yVnqp6q0QE?n9vvqzzLry2 Scale = 1:36.4 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 6x6 6x6 4x8 2x4 5x12 5x12 2x4 3x6 4x8 3x6 4x10 3x6 4x10 2-2-02-2-0 9-0-06-10-0 15-10-06-10-0 18-0-02-2-0 -0-11-4 0-11-4 7-6-0 7-6-0 10-6-0 3-0-0 15-10-0 5-4-0 18-0-0 2-2-0 18-11-4 0-11-4 0-8-85-6-135-8-80-8-81-0-05-6-138.00 12 Plate Offsets (X,Y)-- [5:0-3-8,Edge], [6:0-3-8,Edge], [11:Edge,0-3-8], [13:0-3-0,0-2-12], [15:0-3-0,0-2-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.58 0.52 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.22 0.18 (loc) 13-14 13-14 11 l/defl >999 >975 n/a L/d 240 180 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)17=0-3-8, 11=0-3-8 Max Horz 17=-114(LC 8) Max Uplift 17=-9(LC 10), 11=-9(LC 11) Max Grav 17=773(LC 1), 11=773(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-688/11, 3-4=-1739/86, 4-5=-1993/217, 5-6=-759/52, 6-7=-1993/137, 7-8=-1739/26, 8-9=-688/11, 2-17=-729/52, 9-11=-729/52 BOT CHORD 16-17=-26/405, 14-15=0/729, 13-14=0/729, 11-12=0/384 WEBS 15-16=-19/287, 4-15=-380/166, 12-13=0/262, 7-13=-381/167, 5-15=-228/1166, 6-13=-159/1128, 3-15=-112/1412, 3-16=-431/36, 8-13=-4/1412, 8-12=-401/0 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-4 to 2-0-4, Interior(1) 2-0-4 to 3-3-1, Exterior(2R) 3-3-1 to 14-8-15, Interior(1) 14-8-15 to 15-11-4, Exterior(2E) 15-11-4 to 18-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) The Fabrication Tolerance at joint 2 = 12%, joint 9 = 12% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T34 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673350 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:52 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-YA6hypLVEykLyowS0PSafA1?wDVzlzi80peTMQzLry1 Scale = 1:38.8 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 5x8 5x8 3x6 2x4 3x6 5x8 2x4 3x6 4x6 3x6 4-0-04-0-0 10-0-06-0-0 16-0-06-0-0 19-9-03-9-0 -2-3-12 2-3-12 4-0-0 4-0-0 10-0-0 6-0-0 16-0-0 6-0-0 19-9-0 3-9-0 1-2-143-5-23-6-141-1-20-3-81-4-103-5-27.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-4-0,0-1-11], [5:0-4-0,0-1-11], [7:0-2-7,0-1-7], [9:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.43 0.34 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.10 0.01 (loc) 9 9-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-3 oc purlins, except end verticals, and 2-0-0 oc purlins (4-9-3 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 10-11. REACTIONS. (size)11=0-3-8, 7=0-1-8 Max Horz 11=86(LC 7) Max Grav 11=935(LC 1), 7=769(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-909/19, 3-4=-1268/43, 4-5=-1268/43, 5-6=-890/22, 2-11=-907/91, 6-7=-744/12 BOT CHORD 9-10=-45/738, 8-9=-0/739 WEBS 3-9=-68/619, 4-9=-439/119, 5-9=-68/630, 2-10=0/800, 6-8=-3/730 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -2-3-12 to 0-8-4, Exterior(2R) 0-8-4 to 8-2-15, Interior(1) 8-2-15 to 11-9-1, Exterior(2R) 11-9-1 to 16-7-4, Exterior(2E) 16-7-4 to 19-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T76 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673351 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:53 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-0Ng399M7?FsCZxVea6zpBNa40drgUMZIFTO0vszLry0 Scale = 1:37.0 1 2 3 4 5 11 10 9 8 7 6 12 13 14 15 16 5x8 5x6 3x4 3x6 4x6 3x6 6x8 4x8 6x10 3x6 7-6-87-6-8 12-5-84-11-0 18-0-85-7-0 18-4-00-3-8 -2-3-12 2-3-12 7-6-8 7-6-8 12-5-8 4-11-0 18-0-8 5-7-0 18-4-0 0-3-8 1-2-145-5-152-4-95-7-112-2-91-3-85-5-157.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [3:0-4-0,0-1-11], [4:0-4-12,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.79 0.37 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.15 0.03 (loc) 10-11 10-11 13 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-8 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 13=0-1-8 Max Horz 11=122(LC 7) Max Uplift 11=-26(LC 10) Max Grav 11=882(LC 1), 13=694(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-839/46, 3-4=-550/77, 4-5=-303/78, 2-11=-813/111, 7-12=0/422, 5-12=0/422 BOT CHORD 10-11=-125/273, 8-10=0/618, 7-8=0/555 WEBS 4-8=0/251, 2-10=-21/430, 4-7=-502/0, 5-13=-759/15 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -2-3-12 to 0-8-4, Interior(1) 0-8-4 to 3-3-9, Exterior(2R) 3-3-9 to 16-8-7, Interior(1) 16-8-7 to 17-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 13. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss T77 Truss Type Hip Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673352 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:54 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-UZDSMVNlmZ_3B54r8qU2kb7Eo16dDpiRT77ZRIzLry? Scale = 1:46.4 1 2 3 4 5 6 12 11 10 9 8 7 13 14 15 16 17 4x8 10x16 MT18HS 5x6 6x16 4x6 2x4 6x8 3x4 4x8 3x6 9-6-89-6-8 10-5-80-11-0 18-0-87-7-0 18-4-00-3-8 -2-3-12 2-3-12 4-10-8 4-10-8 9-6-8 4-8-0 10-5-8 0-11-0 15-1-8 4-8-0 18-0-8 2-11-0 18-4-0 0-3-8 1-2-146-7-152-4-96-9-112-2-91-3-86-7-157.00 12 Plate Offsets (X,Y)-- [4:0-4-0,0-1-11], [5:0-1-0,0-4-12], [10:0-3-4,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.85 0.64 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.35 0.03 (loc) 11-12 11-12 14 l/defl >999 >629 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-8: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-8 REACTIONS. (size)12=0-3-8, 14=0-1-8 Max Horz 12=142(LC 7) Max Uplift 12=-34(LC 10) Max Grav 12=882(LC 1), 14=694(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-689/50, 4-5=-537/69, 5-6=-393/106, 2-12=-327/75, 8-13=0/354, 6-13=0/354 BOT CHORD 11-12=-55/637, 9-11=0/529, 8-9=0/529 WEBS 4-11=-69/336, 5-8=-372/0, 3-12=-753/50, 6-14=-774/2 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -2-3-12 to 0-8-4, Interior(1) 0-8-4 to 5-3-9, Exterior(2R) 5-3-9 to 14-8-7, Interior(1) 14-8-7 to 17-10-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 14. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673353 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:56 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-RyLCnAO?IAFmQPDDFFXWp0Cd_qrhhi6kxRcgUBzLrxz Scale = 1:33.5 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 12 19 20 21 22 5x8 5x8 3x8 8x10 8x10 3x6 3x8 10x10 5x12 2x4 10x10 5x12 5x12 3x6 0-10-00-10-0 2-2-01-4-0 3-0-00-10-0 9-0-06-0-0 15-0-06-0-0 15-10-00-10-0 17-2-01-4-0 18-0-00-10-0 -0-11-4 0-11-4 0-10-0 0-10-0 2-2-0 1-4-0 3-0-0 0-10-0 9-0-0 6-0-0 15-0-0 6-0-0 15-10-0 0-10-0 17-2-0 1-4-0 17-8-8 0-6-8 18-0-0 0-3-8 18-11-4 0-11-4 0-8-82-7-32-8-80-8-81-0-02-7-38.00 12 Plate Offsets (X,Y)-- [2:0-4-13,0-0-4], [4:0-2-12,0-4-8], [5:0-4-0,0-1-9], [7:0-4-0,0-1-9], [10:0-4-13,0-0-4], [13:0-2-12,0-4-8], [14:0-3-8,0-5-0], [16:0-3-8,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.62 0.48 0.73 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.41 0.23 (loc) 15 15 10 l/defl >966 >512 n/a L/d 240 180 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 *Except* 13-17: 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-18,8-12,3-17,9-13: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 0-11-7, Right 2x4 SPF-S Stud 0-11-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-5 oc purlins, except 2-0-0 oc purlins (3-11-2 max.): 5-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16, 6-14 REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-47(LC 27) Max Uplift 2=-149(LC 5), 10=-149(LC 4) Max Grav 2=1392(LC 1), 10=1392(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1765/221, 3-4=-3743/518, 4-5=-3678/517, 5-6=-3199/453, 6-7=-3199/418, 7-8=-3678/451, 8-9=-3743/455, 9-10=-1765/223 BOT CHORD 2-18=-173/1146, 16-17=-438/3051, 15-16=-668/4855, 14-15=-668/4855, 13-14=-378/3051, 10-12=-135/1146 WEBS 17-18=-83/612, 4-17=-102/681, 12-13=-61/612, 8-13=-110/681, 5-17=-72/333, 5-16=-168/1293, 6-16=-1727/279, 6-15=-45/328, 6-14=-1727/276, 7-14=-168/1293, 7-13=-43/320, 3-17=-377/2604, 3-18=-1021/157, 9-13=-291/2604, 9-12=-1021/120 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=149, 10=149. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 153 lb down and 50 lb up at 3-0-0, 133 lb down and 39 lb up at 3-0-12, 133 lb down and 39 lb up at 5-0-12, 133 lb down and 39 lb up at 7-0-12, 133 lb down and 39 lb up at 9-0-0, 133 lb down and 39 lb up at 10-11-4, 133 lb down and 39 lb up at 12-11-4, and 133 lb down and 39 lb up at 14-11-4, and 153 lb down and 50 lb up at 15-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673353 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:56 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-RyLCnAO?IAFmQPDDFFXWp0Cd_qrhhi6kxRcgUBzLrxz 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-7=-60, 7-11=-60, 2-18=-20, 13-17=-20, 10-12=-20 Concentrated Loads (lb) Vert: 16=-286(B=-153) 15=-133 14=-286(B=-153) 19=-133 20=-133 21=-133 22=-133 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG02 Truss Type Common Girder Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673354 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:57 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-v8va?WPd3UNd2ZoQpy2lMDljJE8yQ7_u95ME1dzLrxy Scale = 1:41.3 1 2 3 4 5 6 7 11 10 9 812131415 16 17 5x6 5x12 4x10 10x10 5x6 10x10 4x8 3x12 5x8 4x10 4-6-144-6-14 9-0-04-5-2 13-5-24-5-2 18-0-04-6-14 -0-11-4 0-11-4 4-6-14 4-6-14 9-0-0 4-5-2 13-5-2 4-5-2 18-0-0 4-6-14 0-8-86-8-80-8-88.00 12 Plate Offsets (X,Y)-- [2:0-0-1,0-3-6], [7:0-1-9,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.60 0.88 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.19 0.05 (loc) 10-11 10-11 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 193 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-10: 2x4 SPF No.2 WEDGE Left: 2x8 SP 2400F 2.0E SLIDER Right 2x4 SPF-S Stud 2-6-14 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 2=0-3-8 Max Horz 2=120(LC 28) Max Uplift 7=-25(LC 9), 2=-313(LC 8) Max Grav 7=6734(LC 1), 2=5728(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-9131/514, 3-4=-6348/107, 4-5=-6320/108, 5-7=-8794/0 BOT CHORD 2-11=-427/7209, 10-11=-427/7209, 8-10=0/7092, 7-8=0/7092 WEBS 4-10=-54/6627, 5-10=-2340/1, 5-8=0/2829, 3-10=-2483/538, 3-11=-504/3228 NOTES-(9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 3-11 2x4 - 1 row at 0-4-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except (jt=lb) 2=313. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2562 lb down and 462 lb up at 4-5-13, 1405 lb down and 108 lb up at 6-5-13, 1405 lb down and 108 lb up at 8-5-13, 1412 lb down at 10-5-13, 1402 lb down and 30 lb up at 12-5-13, and 1398 lb down and 41 lb up at 14-5-13, and 1398 lb down and 41 lb up at 16-5-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG02 Truss Type Common Girder Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673354 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:57 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-v8va?WPd3UNd2ZoQpy2lMDljJE8yQ7_u95ME1dzLrxy 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 2-7=-20 Concentrated Loads (lb) Vert: 11=-2562(F) 12=-1405(F) 13=-1405(F) 14=-1412(F) 15=-1402(F) 16=-1398(F) 17=-1398(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673355 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:58 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-NKTyCsQGqoVUgjNcNgZ_uRHtreU_9cS1Ol5nZ3zLrxx Scale = 1:64.7 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10192021222324252627282930 4x6 5x12 5x8 5x6 5x10 MT18HS6x16 4x10 5x12 2x4 5x6 3x12 6x18 MT18HS 5x6 5x6 6x16 6x18 MT18HS 6-10-96-10-9 13-7-146-9-5 20-5-36-9-5 27-1-46-8-1 30-0-02-10-12 36-0-06-0-0 6-10-9 6-10-9 13-7-14 6-9-5 20-5-3 6-9-5 27-1-4 6-8-1 30-0-0 2-10-12 36-0-0 6-0-0 37-11-4 1-11-4 3-6-105-1-42-1-43-6-106.00 12 Plate Offsets (X,Y)-- [2:0-3-8,0-2-0], [4:0-3-12,0-3-4], [6:0-9-0,0-2-6], [8:0-3-0,0-1-12], [10:Edge,0-3-8], [17:0-3-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.98 0.62 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.45 -0.86 0.11 (loc) 14-15 14-15 10 l/defl >943 >498 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 197 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-4: 2x4 SPF 2100F 1.8E, 4-6: 2x4 SP 2400F 2.0E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 1-17: 2x4 SPF 2100F 1.8E 2-15,5-15,5-12,6-11,7-11,8-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-8-1 oc purlins, except end verticals, and 2-0-0 oc purlins (2-3-0 max.): 1-6. BOT CHORD Rigid ceiling directly applied or 8-11-14 oc bracing. WEBS 1 Row at midpt 1-18, 5-12, 6-11 REACTIONS. (size)18=Mechanical, 10=0-3-8 Max Horz 18=-116(LC 25) Max Uplift 18=-442(LC 8), 10=-520(LC 8) Max Grav 18=2582(LC 1), 10=2607(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-18=-2370/433, 1-2=-4700/811, 2-3=-7028/1257, 3-5=-7028/1257, 5-6=-5286/1120, 6-7=-3068/703, 7-8=-3101/704, 8-10=-2464/488 BOT CHORD 15-17=-769/4700, 14-15=-1348/7370, 12-14=-1348/7370, 11-12=-1088/5345 WEBS 1-17=-900/5134, 2-17=-1532/333, 2-15=-493/2571, 3-15=-384/109, 5-15=-377/147, 5-14=-58/657, 5-12=-2336/316, 6-12=-219/1354, 6-11=-3965/800, 7-11=-593/2496, 8-11=-565/2716 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 18=442, 10=520. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 137 lb down and 46 lb up at 1-11-4, 137 lb down and 46 lb up at 3-11-4, 137 lb down and 46 lb up at 5-11-4, 137 lb down and 46 lb up at 7-11-4, 137 lb down and 46 lb up at 9-11-4, 137 lb down and 46 lb up at 11-11-4, 137 lb down and 46 lb up at 13-11-4, 137 lb down and 46 lb up at 15-11-4, 137 lb down and 46 lb up at 17-11-4, 137 lb down and 46 lb up at 19-11-4, 137 lb down and 46 lb up at 21-11-4, 208 lb down and 62 lb up at 23-11-4, 147 lb down and 134 lb up at 27-0-0, 114 lb down and 79 lb up at 29-0-0, and 114 lb down and 79 lb up at 31-0-0, and 147 lb down and 134 lb up at 33-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673355 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:59 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-rX1LQCRub5dLHsyowN4DReq2b2qDu3iAdPrK5WzLrxw 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-6=-60, 6-7=-60, 7-8=-60, 8-9=-60, 10-18=-20 Concentrated Loads (lb) Vert: 16=-137 15=-137 12=-134 13=-208 19=-137 20=-137 21=-137 22=-137 23=-137 24=-137 25=-137 26=-137 27=-137 28=-114 29=-114 30=-134 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG04 Truss Type Half Hip Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673356 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:59 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-rX1LQCRub5dLHsyowN4DReqD32yGuEGAdPrK5WzLrxw Scale = 1:20.8 1 2 3 4 6 578 3x4 2x4 3x4 2x4 3x4 1-8-71-8-7 4-5-12-8-10 -1-11-4 1-11-4 1-8-7 1-8-7 4-5-1 2-8-10 2-5-43-5-93-6-143-0-10-5-83-5-98.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge], [5:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 -0.01 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-1 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=101(LC 5) Max Uplift 6=-109(LC 8), 5=-114(LC 5) Max Grav 6=322(LC 1), 5=158(LC 42) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-279/55 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=109, 5=114. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 57 lb down and 122 lb up at 1-8-7, and 56 lb down and 72 lb up at 2-5-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG04 Truss Type Half Hip Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673356 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:50:59 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-rX1LQCRub5dLHsyowN4DReqD32yGuEGAdPrK5WzLrxw LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 7=25(F) 8=-37(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG05 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673357 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:02 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-F6iT2ETmt0?w8KhNcVew3HSaJFrq5MhdJN3?iqzLrxt Scale = 1:40.0 1 2 3 4 5 6 7 16 15 14 13 12 11 10 9 8 17 18 19 20 21 22 23 24 25 26 27 28 29 6x10 6x18 MT18HS 8x14 MT18HS 8x8 4x8 10x10 10x10 2x4 10x10 8x8 10x10 6x6 6x8 3x4 4x6 2-0-02-0-0 5-6-03-6-0 9-0-03-6-0 11-0-02-0-0 13-6-02-6-0 16-0-02-6-0 20-0-04-0-0 2-0-0 2-0-0 9-0-0 7-0-0 11-0-0 2-0-0 16-0-0 5-0-0 20-0-0 4-0-0 21-11-4 1-11-4 2-5-43-7-74-11-75-1-42-5-41-1-124-11-78.00 12 Plate Offsets (X,Y)-- [2:0-5-0,0-0-14], [3:0-9-0,0-2-0], [4:0-1-8,0-4-0], [5:0-5-5,Edge], [6:0-3-8,Edge], [9:0-3-8,0-5-0], [11:0-3-8,0-5-0], [15:0-3-8,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.95 0.69 0.92 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.29 0.04 (loc) 12-13 12-13 8 l/defl >999 >811 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 249 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 2-3: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 *Except* 8-14: 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 *Except* 2-15,3-12,3-11: 2x4 SPF-S Stud OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-4-9 oc purlins, except 2-0-0 oc purlins (4-0-10 max.): 2-3, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)16=0-3-8, 8=0-3-8 Max Horz 16=-120(LC 34) Max Uplift 16=-33(LC 8), 8=-407(LC 9) Max Grav 16=8148(LC 1), 8=8212(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4843/182, 2-3=-9619/372, 3-4=-10576/418, 4-5=-7616/374, 5-6=-6722/360, 1-16=-7587/290, 6-8=-7022/357 BOT CHORD 13-15=-176/4208, 12-13=-313/11798, 11-12=-301/11863, 10-11=-302/8560, 9-10=-270/5578 WEBS 2-15=-2847/174, 2-13=-267/7443, 3-13=-2997/0, 3-12=0/1485, 3-11=-6278/71, 4-11=-166/7355, 4-10=-2005/0, 5-10=-138/4310, 5-9=-383/0, 1-15=-249/6387, 6-9=-300/6275 NOTES-(15-16) 1) n/a 2) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 2 rows at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4) Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) The Fabrication Tolerance at joint 4 = 12% 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Bearing at joint(s) 16, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 Ply to ply nailing inadequate May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG05 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673357 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:02 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-F6iT2ETmt0?w8KhNcVew3HSaJFrq5MhdJN3?iqzLrxt NOTES-(15-16) 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16 except (jt=lb) 8=407. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1405 lb down at 0-9-13, 47 lb down and 80 lb up at 2-0-0, 80 lb down and 104 lb up at 2-0-12, 1398 lb down and 22 lb up at 2-9-13, 80 lb down and 104 lb up at 4-0-12, 1398 lb down and 22 lb up at 4-9-13, 101 lb down and 104 lb up at 6-0-12, 1398 lb down and 22 lb up at 6-9-13, 101 lb down and 104 lb up at 6-11-4, 1397 lb down at 8-9-13, 103 lb down and 119 lb up at 9-0-12, 1403 lb down and 33 lb up at 10-9-13, 166 lb down and 105 lb up at 11-0-12, 1403 lb down and 33 lb up at 12-9-13, 166 lb down and 105 lb up at 13-0-12, 166 lb down and 105 lb up at 13-11-4, 1403 lb down and 33 lb up at 14-9-13, 166 lb down and 105 lb up at 15-11-4, 1403 lb down and 33 lb up at 16-9-13, and 103 lb down and 119 lb up at 17-11-4, and 1403 lb down and 33 lb up at 18-9-13 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 15) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 16) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5=-60, 5-7=-60, 8-16=-20 Concentrated Loads (lb) Vert: 15=16(F) 11=-1496(B=-1403) 9=-93 17=-1405(B) 18=-1398(B) 20=-1398(B) 21=-48 22=-1447(B=-1398) 23=-1493(B=-1397) 24=-1496(B=-1403) 25=-93 26=-1403(B) 27=-1403(B) 28=-95 29=-1403(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG06 Truss Type Half Hip Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673358 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:03 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-jIGrFZUOeK7nmUGZ9D99bU?v3fKqq1FmY1pYEHzLrxs Scale = 1:21.9 1 2 3 4 6 57 3x4 2x4 3x4 3x4 3x4 2-0-02-0-0 4-0-02-0-0 -1-11-4 1-11-4 2-0-0 2-0-0 4-0-0 2-0-0 2-5-43-9-43-3-120-5-83-9-48.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-3], [5:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.31 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.01 -0.01 -0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 5=0-1-8 Max Horz 6=110(LC 5) Max Uplift 6=-71(LC 8), 5=-99(LC 5) Max Grav 6=300(LC 1), 5=124(LC 35) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-269/61 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 5. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 36 lb down and 33 lb up at 2-0-0 on top chord, and 54 lb down and 80 lb up at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-6=-20 Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG06 Truss Type Half Hip Girder Qty 2 Ply 1 3500 Elev C Job Reference (optional) I51673358 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:03 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-jIGrFZUOeK7nmUGZ9D99bU?v3fKqq1FmY1pYEHzLrxs LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 7=17(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG07 Truss Type HIP GIRDER Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673359 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:04 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-CUqDTvV0PeFeOermjwgO8iX_r3SRZJowmgY5njzLrxr Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 1011 17 16 15 14 13 12181920212223242526272829 30 31 5x8 3x6 3x6 3x6 5x12 4x8 2x4 4x6 3x6 2x4 5x12 5x8 2x4 3x6 3x6 5x12 4x8 7-7-47-7-4 14-5-136-10-9 21-6-37-0-5 28-4-126-10-9 36-0-07-7-4 -0-11-4 0-11-4 7-7-4 7-7-4 14-5-13 6-10-9 21-6-3 7-0-5 28-4-12 6-10-9 36-0-0 7-7-4 36-11-4 0-11-4 0-6-84-2-144-4-20-6-84-2-146.00 12 Plate Offsets (X,Y)-- [2:0-2-9,0-2-8], [4:0-4-0,0-1-15], [8:0-4-0,0-1-15], [10:0-2-9,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.69 0.93 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.24 -0.46 0.10 (loc) 14-15 14-15 10 l/defl >999 >924 n/a L/d 240 180 n/a PLATES MT20 Weight: 308 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-6,6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 4-0-9, Right 2x4 SPF-S Stud 4-0-9 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins, except 2-0-0 oc purlins (5-9-9 max.): 4-8. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-52(LC 34) Max Uplift 2=-349(LC 5), 10=-349(LC 4) Max Grav 2=3040(LC 1), 10=3040(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-5560/745, 4-5=-7131/1041, 5-7=-7122/1039, 7-8=-7124/1040, 8-10=-5562/746 BOT CHORD 2-17=-638/4857, 15-17=-636/4826, 14-15=-1002/7129, 12-14=-602/4827, 10-12=-605/4859 WEBS 4-17=-81/834, 4-15=-470/2744, 5-15=-521/141, 7-14=-496/133, 8-14=-468/2734, 8-12=-81/838 NOTES-(11-12) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=349, 10=349. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG07 Truss Type HIP GIRDER Qty 1 Ply 2 3500 Elev C Job Reference (optional) I51673359 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:05 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-ggOcgFVfAxNV?nPyHeBdgv49bTogIm23?KIfJ9zLrxq NOTES-(11-12) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 290 lb down and 69 lb up at 3-8-0, 180 lb down and 38 lb up at 5-8-0, 180 lb down and 52 lb up at 7-8-0, 180 lb down and 52 lb up at 9-8-0, 180 lb down and 52 lb up at 11-8-0, 180 lb down and 52 lb up at 13-8-0, 180 lb down and 52 lb up at 15-8-0, 180 lb down and 52 lb up at 17-8-0, 180 lb down and 52 lb up at 18-4-0, 180 lb down and 52 lb up at 20-4-0, 180 lb down and 52 lb up at 22-4-0, 180 lb down and 52 lb up at 24-4-0, 180 lb down and 52 lb up at 26-4-0, 180 lb down and 52 lb up at 28-4-0, and 180 lb down and 38 lb up at 30-4-0, and 290 lb down and 69 lb up at 32-4-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-8=-60, 8-11=-60, 2-10=-20 Concentrated Loads (lb) Vert: 17=-180 12=-180 18=-290 19=-180 20=-180 21=-180 22=-180 23=-180 24=-180 25=-180 26=-180 27=-180 28=-180 29=-180 30=-180 31=-290 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG08 Truss Type Half Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673360 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:05 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-ggOcgFVfAxNV?nPyHeBdgv49aTy4Ixl3?KIfJ9zLrxq Scale = 1:18.2 1 2 3 4 5 6 7 8 9 10 3x4 8x14 MT18HS 3x6 2-10-02-10-0 7-11-85-1-8 -1-3-4 1-3-4 2-10-0 2-10-0 7-11-8 5-1-8 0-5-51-3-41-4-100-9-120-5-81-3-44.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge], [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.69 0.27 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 0.00 (loc) 2-5 2-5 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 25 lb FT = 20% GRIP 197/144 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-1-8, 2=0-3-8 Max Horz 2=33(LC 28) Max Uplift 5=-14(LC 4), 2=-55(LC 4) Max Grav 5=310(LC 1), 2=420(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-445/69, 3-4=-379/61 BOT CHORD 2-5=-55/377 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 9 lb down and 21 lb up at 2-10-0, and 9 lb down and 20 lb up at 4-10-12, and 9 lb down and 20 lb up at 6-10-12 on top chord, and 32 lb down at 2-9-6, and 8 lb down at 4-10-12, and 8 lb down at 6-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG08 Truss Type Half Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673360 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:05 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-ggOcgFVfAxNV?nPyHeBdgv49aTy4Ixl3?KIfJ9zLrxq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 8=-31(B) 10=-0(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG31 Truss Type Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673361 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:06 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-8ty_ubWHxFVMdx_8rLisD7dHssHL19ZCE_1CrczLrxp Scale = 1:38.7 1 2 3 4 5 6 7 14 13 12 11 10 98 1516 17 18 19 20 5x8 5x10 MT18HS 3x4 2x4 4x6 2x4 2x4 4x6 4x6 3x6 2x4 8x8 2x4 3x8 5-6-8 5-6-8 14-5-8 8-11-0 18-1-8 3-8-0 18-5-12 0-4-4 19-9-0 1-3-4 -2-3-12 2-3-12 5-6-8 5-6-8 14-5-8 8-11-0 18-1-8 3-8-0 18-5-12 0-4-4 19-9-0 1-3-4 1-2-144-3-154-5-110-4-101-0-04-3-157.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-4-0,0-1-11], [4:0-5-12,0-1-8], [7:0-1-10,0-1-8], [9:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.85 0.33 0.99 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.05 -0.11 0.02 (loc) 11-13 11-13 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 96 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-6 oc purlins, except end verticals, and 2-0-0 oc purlins (5-7-10 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 13-14. WEBS 1 Row at midpt 3-11 REACTIONS. (size)7=Mechanical, 14=0-3-8 Max Horz 14=88(LC 7) Max Uplift 14=-10(LC 10) Max Grav 7=770(LC 1), 14=938(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-989/36, 3-4=-822/65, 4-5=-958/43, 5-6=-1347/45, 6-7=-1211/31, 2-14=-894/102 BOT CHORD 11-13=-11/790, 8-9=-15/1007, 7-8=-15/1007 WEBS 5-9=-9/354, 2-13=-9/787, 6-8=-371/19, 9-11=-34/627 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -2-3-12 to 0-8-4, Interior(1) 0-8-4 to 1-3-9, Exterior(2R) 1-3-9 to 9-9-7, Interior(1) 9-9-7 to 10-2-9, Exterior(2R) 10-2-9 to 16-8-4, Exterior(2E) 16-8-4 to 19-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG32 Truss Type Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673362 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:08 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-4F4kIHYXTsl3sF8XymlKIYicNg_ZVBTVhIWJwUzLrxn Scale = 1:39.2 1 2 3 4 5 6 13 12 11 10 9 8 14 15 16 17 18 19 7 20 21 22 23 24 25 4x10 4x10 2x4 3x6 8x8 2x4 3x6 5x6 6x6 2x4 2-0-02-0-0 10-0-08-0-0 18-0-08-0-0 19-5-81-5-8 19-9-00-3-8 -2-3-12 2-3-12 2-0-0 2-0-0 10-0-0 8-0-0 18-0-0 8-0-0 19-5-8 1-5-8 19-9-0 0-3-8 1-2-142-3-91-6-112-4-140-4-11-0-91-4-102-3-97.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-5-0,0-1-2], [5:0-5-0,0-1-2], [11:0-4-0,0-4-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.91 0.28 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.20 0.00 (loc) 11 11 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-11,5-11: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (3-3-12 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. REACTIONS. (size)7=0-1-8, 13=0-3-8 Max Horz 13=66(LC 7) Max Uplift 7=-163(LC 4), 13=-158(LC 5) Max Grav 7=656(LC 22), 13=823(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-727/194, 3-4=-1756/498, 4-5=-1756/498, 5-6=-634/159, 6-7=-329/84, 2-13=-903/156 BOT CHORD 11-12=-213/655, 10-11=-176/672 WEBS 3-11=-333/1158, 4-11=-419/243, 5-11=-344/1123, 5-10=-354/181, 2-12=-192/807, 6-10=-206/826 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=163, 13=158. 7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 34 lb down and 80 lb up at 2-0-0, 39 lb down and 80 lb up at 4-0-12, 39 lb down and 80 lb up at 6-0-12, 39 lb down and 80 lb up at 8-0-12, 39 lb down and 80 lb up at 10-0-0, 39 lb down and 80 lb up at 11-11-4, 39 lb down and 80 lb up at 13-11-4, and 39 lb down and 80 lb up at 15-11-4, and 34 lb down and 80 lb up at 18-0-0 on top chord, and 56 lb down and 63 lb up at 2-0-0, 9 lb down and 15 lb up at 4-0-12, 9 lb down and 15 lb up at 6-0-12, 9 lb down and 15 lb up at 8-0-12, 9 lb down and 15 lb up at 10-0-0, 9 lb down and 15 lb up at 11-11-4, 9 lb down and 15 lb up at 13-11-4, and 9 lb down and 15 lb up at 15-11-4, and 56 lb down and 63 lb up at 17-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss TG32 Truss Type Hip Girder Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673362 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:08 2022 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-4F4kIHYXTsl3sF8XymlKIYicNg_ZVBTVhIWJwUzLrxn 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-5=-60, 5-6=-60, 6-7=-60, 8-13=-20 Concentrated Loads (lb) Vert: 3=26(B) 5=26(B) 4=26(B) 14=26(B) 15=26(B) 16=26(B) 17=26(B) 18=26(B) 19=26(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V01 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673363 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:09 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-YSd6WdZ9EAtwUPjjWUGarlFx44NhEkXfwyGsSwzLrxm Scale = 1:17.8 1 2 3 4 5 6 10 9 8 7 11 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 9-7-29-7-2 2-10-1 2-10-1 9-7-2 6-9-1 0-0-41-10-118.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.27 0.10 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 9-6-12. (lb) - Max Horz 1=45(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 7, 8, 10 except 9=-242(LC 1) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 8=351(LC 1), 10=337(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-8=-255/87 NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 2-10-1, Exterior(2R) 2-10-1 to 6-5-6, Exterior(2E) 6-5-6 to 9-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 8, 10 except (jt=lb) 9=242. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V02 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673364 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:10 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-0eBVjzZn?U?n6ZIw4BnpNzn5zUihzBwo9c0Q_NzLrxl Scale = 1:15.1 1 2 3 4 6 5 7 2x4 3x4 2x4 2x4 2x4 2x4 8-1-28-1-2 3-4-1 3-4-1 8-1-2 4-9-1 0-0-42-2-118.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.33 0.11 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-0-12, 5=8-0-12, 6=8-0-12 Max Horz 1=54(LC 7) Max Uplift 5=-15(LC 6), 6=-18(LC 7) Max Grav 1=120(LC 1), 5=142(LC 24), 6=342(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-254/106 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-4-1, Exterior(2R) 3-4-1 to 4-11-6, Exterior(2E) 4-11-6 to 7-11-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V03 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673365 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:10 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-0eBVjzZn?U?n6ZIw4BnpNzn73UhCzC8o9c0Q_NzLrxl Scale = 1:16.4 1 2 3 4 6 5 2x4 3x4 2x4 2x4 2x4 2x4 6-7-26-7-2 3-10-1 3-10-1 6-7-2 2-9-1 0-0-42-6-118.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.19 0.14 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-6-12, 5=6-6-12, 6=6-6-12 Max Horz 1=63(LC 7) Max Uplift 5=-10(LC 6), 6=-21(LC 10) Max Grav 1=93(LC 1), 5=108(LC 1), 6=276(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-3-9, Exterior(2R) 3-3-9 to 3-10-1, Exterior(2E) 3-10-1 to 6-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V04 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673366 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:11 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-UqltxJaPmn8ekit6duI2wAKJ3t2QifVxNGlzWpzLrxk Scale = 1:19.6 1 2 3 4 6 5 2x4 3x4 2x4 2x4 2x4 2x4 5-1-25-1-2 4-4-1 4-4-1 5-1-2 0-9-1 0-0-42-10-112-4-108.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.11 0.08 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-0-12, 5=5-0-12, 6=5-0-12 Max Horz 1=68(LC 7) Max Uplift 5=-2(LC 11), 6=-36(LC 10) Max Grav 1=74(LC 18), 5=83(LC 1), 6=210(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 4-4-1, Exterior(2E) 4-4-1 to 4-11-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V05 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673367 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:12 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-z1JF8eb2X5GVLsSIBcpHSOtUcHO?R6U5cwVW3FzLrxj Scale = 1:12.3 1 2 3 4 2x4 3x4 2x4 2x4 3-7-23-7-2 2-10-1 2-10-1 3-7-2 0-9-1 0-0-41-10-111-4-108.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-6-12, 4=3-6-12 Max Horz 1=40(LC 9) Max Uplift 1=-1(LC 10), 4=-6(LC 10) Max Grav 1=119(LC 1), 4=119(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V06 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673368 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:12 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-z1JF8eb2X5GVLsSIBcpHSOtVFHP6R6U5cwVW3FzLrxj Scale = 1:7.2 1 2 3 2x4 3x4 2x4 0-0-60-0-6 2-1-22-0-12 1-4-1 1-4-1 2-1-2 0-9-1 0-0-40-10-110-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.02 0.05 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 4 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-1-0, 3=2-1-0 Max Horz 1=-10(LC 6) Max Grav 1=65(LC 1), 3=65(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V07 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673369 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:13 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-RDtdM_cgIOOMz01UlJKW?bPefhkiAYIEraE4bizLrxi Scale = 1:28.8 1 2 3 4 5 6 7 11 10 9 8 12 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-5-210-5-2 7-2-3 7-2-3 8-2-3 1-0-0 10-5-2 2-2-15 0-0-44-9-73-3-84-9-78.00 12 Plate Offsets (X,Y)-- [5:0-2-0,0-2-3], [6:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.17 0.09 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-4-12. (lb) - Max Horz 1=112(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 8, 10, 9, 11 Max Grav All reactions 250 lb or less at joint(s) 1, 8 except 9=290(LC 1), 11=313(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 8-2-3, Exterior(2E) 8-2-3 to 10-3-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 10, 9, 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V08 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673370 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:14 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-vPR?ZKcI2iWDbAbhJ1rlYpynS54lv?tO4E_d78zLrxh Scale = 1:28.3 1 2 3 4 5 6 7 11 10 9 82x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-11-28-11-2 6-2-3 6-2-3 6-8-3 0-6-0 8-11-2 2-2-15 0-0-43-9-74-1-73-9-78.00 12 Plate Offsets (X,Y)-- [5:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.30 0.10 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-10-12. (lb) - Max Horz 1=104(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 8, 11 except 10=-401(LC 3) Max Grav All reactions 250 lb or less at joint(s) 1, 8 except 9=363(LC 3), 11=369(LC 23) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 6-2-3, Exterior(2E) 6-2-3 to 8-9-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 11 except (jt=lb) 10=401. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V09 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673371 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:14 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-vPR?ZKcI2iWDbAbhJ1rlYpynH53Uv?xO4E_d78zLrxh Scale = 1:26.0 1 2 3 4 6 52x4 3x4 2x4 2x4 2x4 2x4 7-5-27-5-2 6-2-3 6-2-3 7-5-2 1-2-15 0-0-44-1-78.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-2-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.31 0.19 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-4-12, 5=7-4-12, 6=7-4-12 Max Horz 1=107(LC 7) Max Uplift 5=-16(LC 7), 6=-59(LC 10) Max Grav 1=113(LC 18), 5=119(LC 1), 6=324(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-8-9, Exterior(2R) 3-8-9 to 6-2-3, Exterior(2E) 6-2-3 to 7-3-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V10 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673372 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:15 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-Nc?Omgdwp0e4CKAtskN_40UzZVQneTLXIujBfazLrxg Scale: 1/2"=1' 1 2 3 5 42x4 2x4 2x4 2x4 2x4 5-11-2 5-11-2 0-0-43-11-68.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.12 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-10-12, 4=5-10-12, 5=5-10-12 Max Horz 1=99(LC 7) Max Uplift 4=-13(LC 7), 5=-58(LC 10) Max Grav 1=86(LC 18), 4=95(LC 17), 5=269(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V11 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673373 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:16 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-roZm_0eYaJmxqUl3QSuDdE1ApumuNwohXYTkC0zLrxf Scale = 1:17.6 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 4-5-2 4-5-2 0-0-42-11-68.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.11 0.06 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-4-12, 4=4-4-12, 5=4-4-12 Max Horz 1=71(LC 7) Max Uplift 4=-10(LC 7), 5=-41(LC 10) Max Grav 1=60(LC 18), 4=70(LC 17), 5=193(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V12 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673374 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:16 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-roZm_0eYaJmxqUl3QSuDdE199ulLNwThXYTkC0zLrxf Scale = 1:12.6 1 2 3 2x4 2x4 2x4 2-11-2 2-11-2 0-0-41-11-68.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-2 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-10-12, 3=2-10-12 Max Horz 1=43(LC 7) Max Uplift 3=-13(LC 10) Max Grav 1=92(LC 1), 3=96(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V14 Truss Type GABLE Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673375 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:17 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-J_68BMfALduoSdKG_9PS9RaJII5F6MUqmCCHkTzLrxe Scale = 1:33.2 1 2 3 4 6 52x4 3x4 2x4 2x4 2x4 2x4 8-2-128-2-12 7-9-5 7-9-5 8-2-12 0-5-7 0-0-45-2-34-10-98.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.19 0.12 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=8-2-12, 5=8-2-12, 6=8-2-12 Max Horz 1=134(LC 9) Max Uplift 5=-11(LC 11), 6=-76(LC 10) Max Grav 1=133(LC 18), 5=127(LC 17), 6=373(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-6=-284/178 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-9-5, Exterior(2R) 4-9-5 to 7-9-5, Exterior(2E) 7-9-5 to 8-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V15 Truss Type GABLE Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673376 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:18 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-nBgWPifo6x0f3nvSYtwhif6TriQbrpxz_syrGvzLrxd Scale = 1:27.1 1 2 3 4 6 52x4 3x4 2x4 2x4 2x4 2x4 6-8-126-8-12 6-3-5 6-3-5 6-8-12 0-5-7 0-0-44-2-33-10-98.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.27 0.17 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-8-12, 5=6-8-12, 6=6-8-12 Max Horz 1=106(LC 9) Max Uplift 1=-7(LC 6), 5=-8(LC 11), 6=-61(LC 10) Max Grav 1=76(LC 18), 5=137(LC 17), 6=304(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 6-3-5, Exterior(2E) 6-3-5 to 6-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V16 Truss Type GABLE Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673377 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:18 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-nBgWPifo6x0f3nvSYtwhif6RUiNGrqzz_syrGvzLrxd Scale = 1:21.1 1 2 3 43x6 3x4 3x4 2x4 5-2-125-2-12 4-9-5 4-9-5 5-2-12 0-5-7 0-0-43-2-32-10-98.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.42 0.32 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 13 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-2-12, 4=5-2-12 Max Horz 1=78(LC 7) Max Uplift 4=-20(LC 10) Max Grav 1=184(LC 1), 4=186(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 3-5-12, Exterior(2R) 3-5-12 to 4-9-5, Exterior(2E) 4-9-5 to 5-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V17 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673378 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:19 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-FNEuc2gRtE8WhxUe5aRwFsfg96mOaHC7DWhOoLzLrxc Scale = 1:13.8 1 2 3 4 2x4 3x4 2x4 2x4 3-8-123-8-12 3-3-5 3-3-5 3-8-12 0-5-7 0-0-41-10-92-2-31-10-98.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.17 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-8-12, 4=3-8-12 Max Horz 1=50(LC 9) Max Uplift 4=-12(LC 10) Max Grav 1=124(LC 1), 4=124(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 3500_ELEV_C Truss V18 Truss Type Valley Qty 1 Ply 1 3500 Elev C Job Reference (optional) I51673379 8.530 s Dec 6 2021 MiTek Industries, Inc. Fri Apr 29 12:51:20 2022 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:W86SVVV9qrHwd_SIVRn9HezrXqs-kZoHqOh3eYGMJ53rfHy9n4Ct0W8EJjSGSARyLozLrxb Scale = 1:8.7 1 2 3 4 2x4 3x4 2x4 2x4 2-2-122-2-12 1-9-5 1-9-5 2-2-12 0-5-7 0-0-41-2-30-10-98.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.03 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-2-12, 4=2-2-12 Max Horz 1=22(LC 9) Max Uplift 4=-4(LC 10) Max Grav 1=64(LC 1), 4=64(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 2,2022 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths