Loading...
HomeMy WebLinkAbout06030225 Site Plan a The Schneider CorporD.tion 8901 Otis Avenue Historic Fort Harrison lndianllpolill, Indiana 46216-1037 317-826-7100 317-826-7200 FAX Engmov1n& SurveyiDc Landscape Archilecture GIS .US Geology lot Plan Prepared for. stridge Custom Homes )t , 862. containing 20,312 5.F.:l:, in ILLAGE OF WESTa.A Y action , 10003 ;strument , 200400030208 .C. , 3, Slide , 396 lay Twp, HamDton County EC.33, T18N, RJE 273 Finchley Rood (SO' R/W) armel, IN 46032 repared Date: 03/17/06 : By: .1<1 lmmunity Restrictions: de Yard = 5' or 8% of Width. ~or Yard = 20' ,gregate = 15' or 18% of \\1dth' Lot Width is measured at the Iilding line. Minimum is the greater the requirements above or os lown on the Recorded Plot lte : The garage finished floor elevation 1.6' above the curb at the drive, per In. Ite: ilder is to grade side yard swale grades shown on this pion. If builder unable to achieve positive drainage away lm proposed structure, the engineer shall contact.d. builder is not to deviate from Jdes 'shown on this plan without the consent both the The_.Schneider Corp. and Brenwick Dev. is plot plan wos prepared sed on information taken lm record plats, subdivision ms, record drawings and ms provided by client. It the responsibility of the ntractor to verify site nditions prior to construction d notify The Schneider rp. and Brenwick Development any discrepancies. mud in streets from trucks lving lot to be cleaned at e end of each day. raw bales and silt fence to be used ler€ needed to keep mud off of reets and out of storm sewers. I service laterals ossing at curb e stamped: ~. \= Sanitary 'Sewer ;= Subsurface Drain = Water eo of water tap to be d filled with granular Jterial to within 10" of p of curb. eo of water tap to be restored its' original condition prior construction. anular back fill suggested Ider driveway at sanitary sewer leral trench, water line trench Id any other excavated areas. situation occurs) cation of utilities on plat plan e general locations per plan d should be verified in the field. lte: (secondary areas - Westclay) lX. height: 35' on lots 100' and larger :) eve line) 3D' on less than 100' lX. coverage: 50% lte: (primary areas - Westclay) lX. height: 30' lild-up line: 2 stories lX. coverage: 50% Id elevation shown is per plans d is not the as-built elevation. e information for the elevation 'ference between the primary finished lor elevation to the top of basement III and to the basement finished floor IS provided by the client. I Plat Plan Legend 1000.0 I Proposed Grodes 000.0 Existing Grades __000.0-- Contour Grode * Approx. Lateral Location - . - Sanitary Sewer Lines - a- Storm Sewer Lines - 'vi - Water Service Lines - - - - - - - Sub-Surface Drain Lines . Manhole (Sanitary or Storm) . Beehive Inlet (Storm) IIlII Curb Inlet (Storm) D End Section (Storm) ..... Fire Hydrant _ 0 0 0 _ 0 0 0 _ Flow Line of swale Building line (BL / BSL) - - - - - - - Easement Line Note: Sanitary Sewer Top of Costing Information Upstream Manhole. TC= 896.25 Downstream Manhole, TC= 898.48 per record drawings. Finished Floor Elevation Information Pad Grode = 898.S per plan Pad Grade + 0,3' = Garage FFE (898.8) Garage FFE + 1.0' = Residnetial FFE (899.8) Residential FFE - 9.0'" = 8asement FFE (890.8) ---J a TC=896.2;-r PER RECORD DRA\\1NG ' --- I, Dennis L. Grumpp, duly licensed Land Surveyor, Indiana # S0303, do hereby certify that in my opinian, if the finished grades are constructed as shown, the Surface Drainage on the subject lot. will be satisfactory far Residential Construction. ,\\1\\1\\\\\11111111/1//////1 #\' C. L /' //% # ~~""...:....,v;Ph~ ff ~,,'~G\S T€"R'~'",~...o~ $<::::::,/''''' No. 0',.",.;<)% ~ ! 50303 ' I % '. STATE OF.. iff ~ /". / ... ,.'(). tt ~ (..(;I>./VDIA~~:"" ~~~ ~ /f() ..S....U"ii~iC~ # ~/,I/I. t\ 't \. \\# /////lll/lillll\l\\\\\I\I\' '\J'- l . P-f1 Nate: The basement elevation, depicted hereon, has been determined and based upon the pod grades and/or contours token from the construction plans for this subdivision. Unless stated, no information about fluctuating water tables, soil conditions, or soil types has been provided or stated on sold pions. It is recommended that the basement finished floor elevations be at least two reet (2') above the normal pool elevation of any adpining bodies of water, unless 0 study of facts reveals otherwise. If during the excavation process any ground water is witnessed, The Schneider Corporation should be notified immediately. The basement elevation should be raised two feet (2') above the ground water, and additional construction techniques should be incorporated to alleviate future problems. i ~ o 4: 1 SLOPf ~ TYPICAL SW,. Detail of Water flow I \ 1\[ II I I Nate: Sump pump(s) to be placed by builder os needed. LOT # 862 VB06,0050733 PO# 00708053 ~ D =~= Note: Builder j positive droinal structure(s). ~ Assumed North Scale: I' = 30' , TC'896.89 PEll RECORD DRA~NGS . t----=:- TC'896.86 PEll RECORO DRA~NGS - ~.. FINCHLEY ROAD 5.0' i-- PEllp ~JoO' LAN 'P7. E[EV=S97.2 B':e- .2 PER PLAN -- - cO :il --- r' 4 WALK ,20~DU&S[ .01.43 i 20' BL 21.0' ~ "* --- 89 .r -a y - CONC. DRIVE S 25.0'- !Hi" ~s 26.5 is::! in 0: ~ PORCH :8.5 I I I I I I , ~ 13.67 22.33 ~ oJ BASEMENT 7' --- --- co CD -", '" ..,,: m ~ N -896.2 - , 40' DU&SE I 897.0 IME 100.00'